The DOI matches its Crossref record; 164 of the 164 references it cites were found in a registry or an index.
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Open accessAbstract
Microdroplets in microfluidics offer a great number of opportunities in chemical and biological research. They provide a compartment in which species or reactions can be isolated, they are monodisperse and therefore suitable for quantitative studies, they offer the possibility to work with extremely small volumes, single cells, or single molecules, and are suitable for high‐throughput experiments. The aim of this Review is to show the importance of these features in enabling new experiments in biology and chemistry. The recent advances in device fabrication are highlighted as are the remaining technological challenges. Examples are presented to show how compartmentalization, monodispersity, single‐molecule sensitivity, and high throughput have been exploited in experiments that would have been extremely difficult outside the microfluidics platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genome sequencing in microfabricated high-density picolitre reactors
Margulies, M., Egholm, M., Altman, W. E., Attiya, S., Bader, J. S., Bemben, L. A., Berka, J., Braverman, M. S., Chen, Y.-J., Chen, Z., et al. (2005) · Nature · doi:10.1038/nature03959 · Cited by 7,693
Next-generation DNA sequencing
Shendure, J., & Ji, H. (2008) · Nature Biotechnology · doi:10.1038/nbt1486 · Cited by 4,509
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
The impact of next-generation sequencing technology on genetics
Mardis, E. R. (2008) · Trends in Genetics · doi:10.1016/j.tig.2007.12.007 · Cited by 2,053
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Cambié, D., Bottecchia, C., Straathof, N. J. W., Hessel, V., & Noël, T. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00707 · Cited by 1,502
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Deciding Whether To Go with the Flow: Evaluating the Merits of Flow Reactors for Synthesis
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201004637 · Cited by 999
Prebiotic Systems Chemistry: New Perspectives for the Origins of Life
Ruiz-Mirazo, K., Briones, C., & de la Escosura, A. (2014) · Chemical Reviews · doi:10.1021/cr2004844 · Cited by 930
Schneider, G. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2017.232 · Cited by 910
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Enzymatic reactions in confined environments
Küchler, A., Yoshimoto, M., Luginbühl, S., Mavelli, F., & Walde, P. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.54 · Cited by 733
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Quantitative and sensitive detection of rare mutations using droplet-based microfluidics
Pekin, D., Skhiri, Y., Baret, J.-C., Le Corre, D., Mazutis, L., Ben Salem, C., Millot, F., El Harrak, A., Hutchison, J. B., Larson, J. W., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20128j · Cited by 540
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Cost-Effective Three-Dimensional Printing of Visibly Transparent Microchips within Minutes
Shallan, A. I., Smejkal, P., Corban, M., Guijt, R. M., & Breadmore, M. C. (2014) · Analytical Chemistry · doi:10.1021/ac4041857 · Cited by 501
Taly, V., Pekin, D., Benhaim, L., Kotsopoulos, S. K., Le Corre, D., Li, X., Atochin, I., Link, D. R., Griffiths, A. D., Pallier, K., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206359 · Cited by 492
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
One-Step Fabrication of Supramolecular Microcapsules from Microfluidic Droplets
Zhang, J., Coulston, R. J., Jones, S. T., Geng, J., Scherman, O. A., & Abell, C. (2012) · Science · doi:10.1126/science.1215416 · Cited by 456
Self-citationWörner, M. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0940-8 · Cited by 438
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Dripping and jetting in microfluidic multiphase flows applied to particle and fibre synthesis
Nunes, J. K., Tsai, S. S. H., Wan, J., & Stone, H. A. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114002 · Cited by 406
Noël, T., & Buchwald, S. L. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15075h · Cited by 382
Faustini, M., Kim, J., Jeong, G.-Y., Kim, J. Y., Moon, H. R., Ahn, W.-S., & Kim, D.-P. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4039642 · Cited by 374
Shembekar, N., Chaipan, C., Utharala, R., & Merten, C. A. (2016) · Lab on a Chip · doi:10.1039/c6lc00249h · Cited by 372
Analytical detection techniques for droplet microfluidics—A review
Zhu, Y., & Fang, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.064 · Cited by 365
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Advances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
Enhanced transcription rates in membrane-free protocells formed by coacervation of cell lysate
Sokolova, E., Spruijt, E., Hansen, M. M. K., Dubuc, E., Groen, J., Chokkalingam, V., Piruska, A., Heus, H. A., & Huck, W. T. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1222321110 · Cited by 347
Self-citationDigital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Droplets Formation and Merging in Two-Phase Flow Microfluidics
Gu, H., Duits, M. H. G., & Mugele, F. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12042572 · Cited by 312
MaxSynBio: Avenues Towards Creating Cells from the Bottom Up
Schwille, P., Spatz, J., Landfester, K., Bodenschatz, E., Herminghaus, S., Sourjik, V., Erb, T. J., Bastiaens, P., Lipowsky, R., Hyman, A., et al. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201802288 · Cited by 311
Digital Assays Part I: Partitioning Statistics and Digital PCR
Basu, A. S. (2017) · SLAS Technology · doi:10.1177/2472630317705680 · Cited by 300
Active droplet generation in microfluidics
Chong, Z. Z., Tan, S. H., Gañán-Calvo, A. M., Tor, S. B., Loh, N. H., & Nguyen, N.-T. (2016) · Lab on a Chip · doi:10.1039/c5lc01012h · Cited by 297
Multiplex digital PCR: breaking the one target per color barrier of quantitative PCR
Zhong, Q., Bhattacharya, S., Kotsopoulos, S., Olson, J., Taly, V., Griffiths, A. D., Link, D. R., & Larson, J. W. (2011) · Lab on a Chip · doi:10.1039/c1lc20126c · Cited by 297
Droplet digital PCR of viral DNA/RNA, current progress, challenges, and future perspectives
Kojabad, A. A., Farzanehpour, M., Galeh, H. E. G., Dorostkar, R., Jafarpour, A., Bolandian, M., & Nodooshan, M. M. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26846 · Cited by 297
High-resolution dose–response screening using droplet-based microfluidics
Miller, O. J., Harrak, A. E., Mangeat, T., Baret, J.-C., Frenz, L., Debs, B. E., Mayot, E., Samuels, M. L., Rooney, E. K., Dieu, P., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1113324109 · Cited by 286
Ultrahigh-throughput discovery of promiscuous enzymes by picodroplet functional metagenomics
Colin, P.-Y., Kintses, B., Gielen, F., Miton, C. M., Fischer, G., Mohamed, M. F., Hyvönen, M., Morgavi, D. P., Janssen, D. B., & Hollfelder, F. (2015) · Nature Communications · doi:10.1038/ncomms10008 · Cited by 281
Self-citationDroplet microfluidics driven by gradients of confinement
Dangla, R., Kayi, S. C., & Baroud, C. N. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209186110 · Cited by 279
Functional single-cell hybridoma screening using droplet-based microfluidics
Debs, B. E., Utharala, R., Balyasnikova, I. V., Griffiths, A. D., & Merten, C. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204514109 · Cited by 276
Ultrahigh-throughput–directed enzyme evolution by absorbance-activated droplet sorting (AADS)
Gielen, F., Hours, R., Emond, S., Fischlechner, M., Schell, U., & Hollfelder, F. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1606927113 · Cited by 269
Self-citationMicrodroplet fusion mass spectrometry for fast reaction kinetics
Lee, J. K., Kim, S., Nam, H. G., & Zare, R. N. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1503689112 · Cited by 268
Recent advances in micro reaction technology
Wiles, C., & Watts, P. (2011) · Chemical Communications · doi:10.1039/c1cc00089f · Cited by 264
Microfluidic Generation of Multifunctional Quantum Dot Barcode Particles
Zhao, Y., Shum, H. C., Chen, H., Adams, L. L. A., Gu, Z., & Weitz, D. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja200729w · Cited by 264
Fallah-Araghi, A., Baret, J.-C., Ryckelynck, M., & Griffiths, A. D. (2012) · Lab on a Chip · doi:10.1039/c2lc21035e · Cited by 261
Probing cellular heterogeneity in cytokine-secreting immune cells using droplet-based microfluidics
Chokkalingam, V., Tel, J., Wimmers, F., Liu, X., Semenov, S., Thiele, J., Figdor, C. G., & Huck, W. T. S. (2013) · Lab on a Chip · doi:10.1039/c3lc50945a · Cited by 252
Self-citationBridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Sun, M., & Vanapalli, S. A. (2013) · Analytical Chemistry · doi:10.1021/ac303526y · Cited by 26
Matching together living cells and prototissues: will there Be chemistry?
Valente, S., Galanti, A., Maghin, E., Najdi, N., Piccoli, M., & Gobbo, P. (2024) · ChemBioChem · doi:10.1002/cbic.202400378 · Cited by 10
Metadata
- Authors
- Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2010-07-30
- Volume
- 49
- Issue
- 34
- Pages
- 5846-5868
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2004258912
- Cited by
- 1,059
- References
- 164
- FWCI
- 48.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.