Flexible Rolled Thick‐Film Miniaturized Flow‐Cell for Minimally Invasive Amperometric Sensing
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We describe here a miniaturized flexible thick‐film electrochemical biosensor flow detector, suitable for insertion into the lacrimal canaliculus towards minimally invasive amperometric monitoring of biomarkers in the tear fluid. Our focus here is on the microfabrication and in‐vitro testing of the new laterally rolled screen‐printed sensor. The new device responds rapidly and sensitively to dynamic changes in the levels of norepinephrine and glucose (the later in connection to glucose‐oxidase containing ink). Coverage of the enzyme electrode with an electropolymerized polytyramine minimizes contributions from the common electroactive interferences ascorbic and uric acids. Such attractive performance indicates great promise for minimally invasive monitoring of health biomarkers in the tear fluid, or in alternative usage such as capillary microelectrophoresis, ultralow volume sampling, or in‐flow (tubular) systems for batch processing of blood or culture media.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Self-citationBiosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187
A flexible and wearable biosensor for tear glucose measurement
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9073-3 · Cited by 173
Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers
Baca, J. T., Taormina, C. R., Feingold, E., Finegold, D. N., Grabowski, J. J., & Asher, S. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.078543 · Cited by 110
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Self-citationElectrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Self-citationGlucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2013) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 696
Self-citationA contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
“, 2007) or by screen printing techniques (Kagie et al., 2008).”
InfluentialAdvanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
Self-citationWearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Self-citationNon-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Self-citationTattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 312
Self-citationAdvances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Wearable electrochemical biosensors in North America
Min, J., Sempionatto, J. R., Teymourian, H., Wang, J., & Gao, W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112750 · Cited by 278
Self-citationWearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193
Self-citationMeasurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Miniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S. (2013) · Analytical Chemistry · doi:10.1021/ac4006793 · Cited by 173
Evaluation of commercial glucometer test strips for potential measurement of glucose in tears
Cha, K. H., Jensen, G. C., Balijepalli, A. S., Cohan, B. E., & Meyerhoff, M. E. (2014) · Analytical Chemistry · doi:10.1021/ac4040168 · Cited by 67
Patel, J. N., Gray, B. L., Kaminska, B., & Gates, B. D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500503 · Cited by 18
Metadata
- Authors
- Kagie, A., Bishop, D. K., Burdick, J., La Belle, J. T., Dymond, R., Felder, R., & Wang, J.
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2008-07
- Volume
- 20
- Issue
- 14
- Pages
- 1610-1614
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2147301606
- Cited by
- 77
- References
- 5
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.