The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Fluid shear stress as a mediator of osteoblast cyclic adenosine monophosphate production
Abstract
Effects of interstitial fluid flow on osteoblasts were investigated. Intracellular cyclic adenosine monophosphate (cAMP) levels were monitored in cultured osteo‐blasts subjected to shear rates ranging from 10 to 3,500 sec−1. Cyclic AMP levels were significantly increased at all shear rates from 1 pmole/mg protein to 10‐16 pmole/mg protein. Osteoblasts subjected to a shear rate of 430 sec−1 for 0.5‐15 minutes exhibited elevated levels (12‐fold) of intracellular cAMP, which were sustained throughout the perfusion period. Osteoblasts were three times more sensitive to flow stimulation than human umbilical vein endothelial cells and baby hamster kidney fibroblasts, which also displayed higher cAMP levels (4‐fold) after exposure to flow. To distinguish streaming potential effects from shear stress effects, viscosity was increased 5‐fold by addition of neutral dextran to the perfusing medium. Shear stress is a function of viscosity, and streaming potentials are not for a given shear rate. The mechanism of this cellular response to flow was shown to be shear stress dependent. Inhibition of cyclooxygenase by 20 μM ibuprofen completely inhibited the flow‐dependent cAMP response, indicating the cAMP response is mediated by prostaglandins. Our results suggest that fluid flow induced by mechanical stress may be an important mediator of bone remodeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Das Gesetz der Transformation der Knochen
Wolff, J. (1893) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-0028-1144106 · Cited by 1,999
Flow Effects on Prostacyclin Production by Cultured Human Endothelial Cells
Frangos, J. A., Eskin, S. G., McIntire, L. V., & Ives, C. L. (1985) · Science · doi:10.1126/science.3883488 · Cited by 1,235
Self-citationEffects of immobilization upon various metabolic and physiologic functions of normal men
Deitrick, J. E., Whedon, G. D., & Shorr, E. (1948) · The American Journal of Medicine · doi:10.1016/0002-9343(48)90370-2 · Cited by 610
Functional adaptation of bone to increased stress. An experimental study.
Goodship, A. E., Lanyon, L. E., & McFie, H. (1979) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197961040-00008 · Cited by 416
Shear stress induced stimulation of mammalian cell metabolism
Frangos, J. A., McIntire, L. V., & Eskin, S. G. (1988) · Biotechnology and Bioengineering · doi:10.1002/bit.260320812 · Cited by 373
Self-citationOsteoblasts isolated from mouse calvaria initiate matrix mineralization in culture.
Ecarot-Charrier, B., Glorieux, F. H., van der Rest, M., & Pereira, G. (1983) · The Journal of cell biology · doi:10.1083/jcb.96.3.639 · Cited by 359
Bone remodelling induced by physical stress is prostaglandin E2 mediated
Somjen, D., Binderman, I., Berger, E., & Harell, A. (1980) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(80)90126-9 · Cited by 333
Buckley, M. J., Banes, A. J., Levin, L. G., Sumpio, B. E., Sato, M., Jordan, R., Gilbert, J. L., Link, G. W., & Tay, R. T. S. (1988) · PubMed · Cited by 269
Cyclic AMP and Cyclic GMP: Mediators of the Mechanical Effects on Bone Remodeling
Rodan, G. A., Bourret, L. A., Harvey, A., & Mensi, T. (1975) · Science · doi:10.1126/science.168639 · Cited by 202
Streaming potential and the electromechanical response of physiologically-moist bone
Gross, D., & Williams, W. S. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90174-9 · Cited by 192
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
BIOMECHANICAL AND MOLECULAR REGULATION OF BONE REMODELING
Robling, A. G., Castillo, A. B., & Turner, C. H. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095721 · Cited by 1,343
Osteocytes, mechanosensing and Wnt signaling
Bonewald, L. F., & Johnson, M. L. (2008) · Bone · doi:10.1016/j.bone.2007.12.224 · Cited by 1,076
“Originally steady or laminar fluid shear stress was used in vitro to mimic in vivo shear stress [103,128], this was followed by pulsatile fluid flow [49], followed by oscillatory flow [54].”
Mechanotransduction and the functional response of bone to mechanical strain
Duncan, R. L., & Turner, C. H. (1995) · Calcified Tissue International · doi:10.1007/bf00302070 · Cited by 1,048
Bone Graft Materials: An Overview of the Basic Science
Bauer, T. W., & Muschler, G. F. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00003 · Cited by 998
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Mechanotransduction in bone—role of the lacunocanalicular network
Burger, E. H., & Klein‐Nulend, J. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.9001.s101 · Cited by 897
Bancroft, G. N., Sikavitsas, V. I., van den Dolder, J., Sheffield, T. L., Ambrose, C. G., Jansen, J. A., & Mikos, A. G. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.202296599 · Cited by 693
Lian, J. B., & Stein, G. S. (1992) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411920030030501 · Cited by 582
Effects of Mechanical Forces on Signal Transduction and Gene Expression in Endothelial Cells
Chien, S., Li, S., & Shyy, J. Y.-J. (1998) · Hypertension · doi:10.1161/01.hyp.31.1.162 · Cited by 574
Biomaterials and bone mechanotransduction
Sikavitsas, V. I., Temenoff, J. S., & Mikos, A. G. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00002-3 · Cited by 519
Role of calcium and calmodulin in flow-induced nitric oxide production in endothelial cells
Kuchan, M. J., & Frangos, J. A. (1994) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1994.266.3.c628 · Cited by 518
Self-citationMechanical Strain and Bone Cell Function: A Review
Ehrlich, P. J., & Lanyon, L. E. (2002) · Osteoporosis International · doi:10.1007/s001980200095 · Cited by 512
Cherian, P. P., Siller-Jackson, A. J., Gu, S., Wang, X., Bonewald, L. F., Sprague, E., & Jiang, J. X. (2005) · Molecular Biology of the Cell · doi:10.1091/mbc.e04-10-0912 · Cited by 481
Goldstein, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00280-5 · Cited by 476
Molecular pathways mediating mechanical signaling in bone
Rubin, J., Rubin, C., & Jacobs, C. R. (2006) · Gene · doi:10.1016/j.gene.2005.10.028 · Cited by 474
Sikavitsas, V. I., Bancroft, G. N., Holtorf, H. L., Jansen, J. A., & Mikos, A. G. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2434367100 · Cited by 472
Differential effect of steady versus oscillating flow on bone cells
Jacobs, C. R., Yellowley, C. E., Davis, B. R., Zhou, Z., Cimbala, J. M., & Donahue, H. J. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00114-6 · Cited by 453
Mechanotransduction in bone: do bone cells act as sensors of fluid flow?
Turner, C. H., Forwood, M. R., & Otter, M. W. (1994) · The FASEB Journal · doi:10.1096/fasebj.8.11.8070637 · Cited by 411
Function of osteocytes in bone
Aarden, E. M., Nijweide, P. J., & Burger, E. H. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240550304 · Cited by 409
Turner, C. H., & Pavalko, F. M. (1998) · Journal of Orthopaedic Science · doi:10.1007/s007760050064 · Cited by 395
Fluid and Solute Transport in Bone: Flow-Induced Mechanotransduction
Fritton, S. P., & Weinbaum, S. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.010908.165136 · Cited by 380
Effects of Loading Frequency on Mechanically Induced Bone Formation
Hsieh, Y.-F., & Turner, C. H. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.5.918 · Cited by 370
Mechanotransduction in bone: role of strain rate
Turner, C. H., Owan, I., & Takano, Y. (1995) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1995.269.3.e438 · Cited by 358
Bone Strength: Current Concepts
TURNER, C. H. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1346.039 · Cited by 343
Finite element study of scaffold architecture design and culture conditions for tissue engineering
Olivares, A. L., Marsal, È., Planell, J. A., & Lacroix, D. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.041 · Cited by 339
The production of nitric oxide and prostaglandin E2 by primary bone cells is shear stress dependent
Bakker, A. D., Soejima, K., Klein-Nulend, J., & Burger, E. H. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00231-1 · Cited by 311
Shear Stress Induces Osteogenic Differentiation of Human Mesenchymal Stem Cells
Yourek, G., McCormick, S. M., Mao, J. J., & Reilly, G. C. (2010) · Regenerative Medicine · doi:10.2217/rme.10.60 · Cited by 303
Low‐Magnitude Mechanical Loading Becomes Osteogenic When Rest Is Inserted Between Each Load Cycle
Srinivasan, S., Weimer, D. A., Agans, S. C., Bain, S. D., & Gross, T. S. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.9.1613 · Cited by 299
Ca2+regulates fluid shear-induced cytoskeletal reorganization and gene expression in osteoblasts
Chen, N. X., Ryder, K. D., Pavalko, F. M., Turner, C. H., Burr, D. B., Qiu, J., & Duncan, R. L. (2000) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2000.278.5.c989 · Cited by 293
Molecular events caused by mechanical stress in bone
Nomura, S., & Takano-Yamamoto, T. (2000) · Matrix Biology · doi:10.1016/s0945-053x(00)00050-0 · Cited by 285
Review: Bone tissue engineering: The role of interstitial fluid flow
Hillsley, M. V., & Frangos, J. A. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260430706 · Cited by 270
Self-citationRobling, A. G., Duijvelaar, K. M., Geevers, J. V., Ohashi, N., & Turner, C. H. (2001) · Bone · doi:10.1016/s8756-3282(01)00488-4 · Cited by 259
Effect of flow on prostaglandin E2 and inositol trisphosphate levels in osteoblasts
Reich, K. M., & Frangos, J. A. (1991) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1991.261.3.c428 · Cited by 255
Self-citationFrom streaming‐potentials to shear stress: 25 years of bone cell mechanotransduction
Riddle, R. C., & Donahue, H. J. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20723 · Cited by 157
Kanematsu, M., Yoshimura, K., Takaoki, M., & Sato, A. (2002) · Bone · doi:10.1016/s8756-3282(02)00680-4 · Cited by 31
Metadata
- Authors
- Reich, K. M., Gay, C. V., & Frangos, J. A.
- Venue
- Journal of Cellular Physiology
- Publisher
- Wiley
- Published
- 1990-04
- Volume
- 143
- Issue
- 1
- Pages
- 100-104
- ISSN
- 0021-9541 (ISSN-L)
- 1097-4652
- OpenAlex
- W2084087342
- Cited by
- 344
- References
- 22
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.