The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast‐enhanced MRI alone and in combination: Preliminary experience
Open accessAbstract
Purpose: To report our preliminary experience with the use of intravoxel incoherent motion (IVIM) diffusion‐weighted magnetic resonance imaging (DW‐MRI) and dynamic contrast‐enhanced (DCE)‐MRI alone and in combination for the diagnosis of liver cirrhosis. Materials and Methods: Thirty subjects (16 with noncirrhotic liver, 14 with cirrhosis) were prospectively assessed with IVIM DW‐MRI (n = 27) and DCE‐MRI (n = 20). IVIM parameters included perfusion fraction (PF), pseudodiffusion coefficient (D*), true diffusion coefficient (D), and apparent diffusion coefficient (ADC). Model‐free DCE‐MR parameters included time to peak (TTP), upslope, and initial area under the curve at 60 seconds (IAUC60). A dual input single compartmental perfusion model yielded arterial flow (Fa), portal venous flow (Fp), arterial fraction (ART), mean transit time (MTT), and distribution volume (DV). The diagnostic performances for diagnosis of cirrhosis were evaluated for each modality alone and in combination using logistic regression and receiver operating characteristic analyses. IVIM and DCE‐MR parameters were compared using a generalized estimating equations model. Results: PF, D*, D, and ADC values were significantly lower in cirrhosis (P = 0.0056–0.0377), whereas TTP, DV, and MTT were significantly increased in cirrhosis (P = 0.0006–0.0154). There was no correlation between IVIM‐ and DCE‐MRI parameters. The highest Az (areas under the curves) values were observed for ADC (0.808) and TTP‐DV (0.952 for each). The combination of ADC with DV and TTP provided 84.6% sensitivity and 100% specificity for diagnosis of cirrhosis. Conclusion: The combination of DW‐MRI and DCE‐MRI provides an accurate diagnosis of cirrhosis. J. Magn. Reson. Imaging 2010;31:589–600. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection
Regev, A., Berho, M. E., Jeffers, L. J., Milikowski, C., Molina, E. G., Pyrsopoulos, N., Feng, Z.-Z., Reddy, K. R., & Schiff, E. R. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04396-4 · Cited by 2,093
Evaluation of Liver Fibrosis: A Concise Review
Afdhal, N. H., & Nunes, D. (2004) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2004.30110.x · Cited by 622
Exponential analysis in physical phenomena
Istratov, A. A., & Vyvenko, O. F. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149581 · Cited by 615
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
Maharaj, B., Leary, W. P., Naran, A. D., Maharaj, R. J., Cooppan, R. M., Pirie, D., & Pudifin, D. J. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90883-4 · Cited by 608
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Self-citationYamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Survival, liver failure, and hepatocellular carcinoma in obesity-related cryptogenic cirrhosis
Ratziu, V., Bonyhay, L., Di Martino, V., Charlotte, F., Cavallaro, L., Sayegh-Tainturier, M.-H., Giral, P., Grimaldi, A., Opolon, P., & Poynard, T. (2002) · Hepatology · doi:10.1053/jhep.2002.33324 · Cited by 464
Letter: The consultants' contract.
Plumley, P. F. (1974) · PubMed · Cited by 460
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423
The role of liver biopsy in chronic hepatitis C
Dienstag, J. L. (2002) · Hepatology · doi:10.1002/hep.1840360720 · Cited by 373
NIH Consensus Statement on Management of Hepatitis C: 2002.
(2002) · PubMed · Cited by 364
Diffusion-weighted single-shot echoplanar MR imaging for liver disease.
Kim, T., Murakami, T., Takahashi, S., Hori, M., Tsuda, K., & Nakamura, H. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.2.10430143 · Cited by 349
Focal liver masses: characterization with diffusion-weighted echo-planar MR imaging.
Namimoto, T., Yamashita, Y., Sumi, S., Tang, Y., & Takahashi, M. (1997) · Radiology · doi:10.1148/radiology.204.3.9280252 · Cited by 349
Van Beers, B. E., Leconte, I., Materne, R., Smith, A. M., Jamart, J., & Horsmans, Y. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.3.1760667 · Cited by 321
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Annet, L., Materne, R., Danse, E., Jamart, J., Horsmans, Y., & Van Beers, B. E. (2003) · Radiology · doi:10.1148/radiol.2292021128 · Cited by 295
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., et al. (2007) · Hepatology · doi:10.1002/hep.21747 · Cited by 265
Bihan, D. L., Turner, R., & Macfall, J. R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100305 · Cited by 228
Advanced Liver Fibrosis: Diagnosis with 3D Whole-Liver Perfusion MR Imaging—Initial Experience
Hagiwara, M., Rusinek, H., Lee, V. S., Losada, M., Bannan, M. A., Krinsky, G. A., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070077 · Cited by 227
Self-citationAssessment of hepatic perfusion parameters with dynamic MRI
Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10045 · Cited by 226
Koinuma, M., Ohashi, I., Hanafusa, K., & Shibuya, H. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20344 · Cited by 218
Intravoxel incoherent motion imaging using steady‐state free precession
Le Bihan, D. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910070312 · Cited by 217
Taouli, B., Chouli, M., Martin, A. J., Qayyum, A., Coakley, F. V., & Vilgrain, V. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21227 · Cited by 207
Self-citationBraithwaite, A. C., Dale, B. M., Boll, D. T., & Merkle, E. M. (2009) · Radiology · doi:10.1148/radiol.2502080849 · Cited by 195
Taouli, B., Sandberg, A., Stemmer, A., Parikh, T., Wong, S., Xu, J., & Lee, V. S. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21876 · Cited by 167
Self-citationKoh, D.-M., Blackledge, M., Collins, D. J., Padhani, A. R., Wallace, T., Wilton, B., Taylor, N. J., Stirling, J. J., Sinha, R., Walicke, P., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1469-4 · Cited by 163
Assessment of diffusion‐weighted MR imaging in liver fibrosis
Annet, L., Peeters, F., Abarca‐Quinones, J., Leclercq, I. A., Moulin, P., & BEERS, B. E. V. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20771 · Cited by 148
Wirestam, R., Borg, M., Brockstedt, S., Lindgren, A., Holtås, S., & Ståhlberg, F. (2001) · Acta Radiologica · doi:10.1034/j.1600-0455.2001.042002123.x · Cited by 146
Taouli, B. A., Martin, A. J., Qayyum, A., Merriman, R. B., Vigneron, D. B., Yeh, B. M., & Coakley, F. V. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.3.1830677 · Cited by 134
Self-citationDiagnostic et quantification de la fibrose hépatique par IRM de diffusion : résultats préliminaires
Aubé, C., Racineux, P. X., Lebigot, J., Oberti, F., Croquet, V., Argaud, C., Calès, P., & Caron, C. (2004) · Journal de Radiologie · doi:10.1016/s0221-0363(04)97582-8 · Cited by 109
Girometti, R., Furlan, A., Esposito, G., Bazzocchi, M., Como, G., Soldano, F., Isola, M., Toniutto, P., & Zuiani, C. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21461 · Cited by 105
Jones, R. A., Easley, K. A., Little, S. B., Scherz, H. C., Kirsch, A. J., & Grattan‐Smith, J. D. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.04.1540 · Cited by 105
In vivo study of microcirculation in canine myocardium using the IVIM method†
Callot, V., Bennett, E. E., Decking, U. K. M., Balaban, R. S., & Wen, H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10568 · Cited by 104
Does IVIM measure classical perfusion?
Henkelman, R. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160313 · Cited by 101
Moteki, T., & Horikoshi, H. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20682 · Cited by 93
Kim, A. I., & Saab, S. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.01.073 · Cited by 85
Intravoxel incoherent motion imaging using spin echoes
Bihan, D. L., & Turner, R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190206 · Cited by 77
Quantitative determination of Gd‐DTPA concentration in T 1 ‐weighted MR renography studies
Bokacheva, L., Rusinek, H., Chen, Q., Oesingmann, N., Prince, C. N., Kaur, M., Kramer, E., & Lee, V. S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21169 · Cited by 68
Self-citationGrønbæk, K., Christensen, P. B., Hamilton-Dutoit, S. J., Federspiel, B., Häge, E., Jensen, O., & Vyberg, M. (2002) · Journal of Viral Hepatitis · doi:10.1046/j.1365-2893.2002.00389.x · Cited by 67
Weigand, K., & Weigand, K. (2009) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.2008.05718.x · Cited by 53
Miyazaki, K., Collins, D. J., Walker‐Samuel, S., Taylor, N. J., Padhani, A. R., Leach, M. O., & Koh, D. (2008) · European Radiology · doi:10.1007/s00330-008-0898-9 · Cited by 37
Cited by
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
What can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Selection for hepatic resection of colorectal liver metastases: expert consensus statement
Adams, R. B., Aloia, T. A., Loyer, E., Pawlik, T. M., Taouli, B., & Vauthey, J. (2013) · HPB · doi:10.1111/j.1477-2574.2012.00557.x · Cited by 331
Self-citationAndreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
Metadata
- Authors
- Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-02-25
- Volume
- 31
- Issue
- 3
- Pages
- 589-600
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2102942854
- Cited by
- 371
- References
- 45
- FWCI
- 22.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.