The DOI matches its Crossref record; 105 of the 105 references it cites were found in a registry or an index.
Ion mobility spectrometry‐mass spectrometry (IMS‐MS) of small molecules: Separating and assigning structures to ions
Abstract
The phenomenon of ion mobility (IM), the movement/transport of charged particles under the influence of an electric field, was first observed in the early 20th Century and harnessed later in ion mobility spectrometry (IMS). There have been rapid advances in instrumental design, experimental methods, and theory together with contributions from computational chemistry and gas‐phase ion chemistry, which have diversified the range of potential applications of contemporary IMS techniques. Whilst IMS‐mass spectrometry (IMS‐MS) has recently been recognized for having significant research/applied industrial potential and encompasses multi‐/cross‐disciplinary areas of science, the applications and impact from decades of research are only now beginning to be utilized for “small molecule” species. This review focuses on the application of IMS‐MS to “small molecule” species typically used in drug discovery (100–500 Da) including an assessment of the limitations and possibilities of the technique. Potential future developments in instrumental design, experimental methods, and applications are addressed. The typical application of IMS‐MS in relation to small molecules has been to separate species in fairly uniform molecular classes such as mixture analysis, including metabolites. Separation of similar species has historically been challenging using IMS as the resolving power, R, has been low (3–100) and the differences in collision cross‐sections that could be measured have been relatively small, so instrument and method development has often focused on increasing resolving power. However, IMS‐MS has a range of other potential applications that are examined in this review where it displays unique advantages, including: determination of small molecule structure from drift time, “small molecule” separation in achiral and chiral mixtures, improvement in selectivity, identification of carbohydrate isomers, metabonomics, and for understanding the size and shape of small molecules. This review provides a broad but selective overview of current literature, concentrating on IMS‐MS, not solely IMS, and small molecule applications. © 2012 Wiley Periodicals, Inc., Mass Spec Rev 32:43–71, 2013
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipinski, C. A., Lombardo, F., Dominy, B. W., & Feeney, P. J. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(96)00423-1 · Cited by 11,385
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Aerosol classification by electric mobility: apparatus, theory, and applications
Knutson, E. O., & Whitby, K. T. (1975) · Journal of Aerosol Science · doi:10.1016/0021-8502(75)90060-9 · Cited by 1,395
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Fundamentals of Traveling Wave Ion Mobility Spectrometry
Shvartsburg, A. A., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac8016295 · Cited by 534
Biomolecule Analysis by Ion Mobility Spectrometry
Bohrer, B. C., Merenbloom, S. I., Koeniger, S. L., Hilderbrand, A. E., & Clemmer, D. E. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113001 · Cited by 492
Ion mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Buryakov, I. A., Krylov, E. V., Nazarov, E. G., & Rasulev, U. K. (1993) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)87062-w · Cited by 444
Protein Structure in Vacuo: Gas-Phase Conformations of BPTI and Cytochrome c
Shelimov, K. B., Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9619059 · Cited by 414
Protein structure, stability and solubility in water and other solvents
Nick Pace, C., Treviño, S., Prabhakaran, E., & Martin Scholtz, J. (2004) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2004.1500 · Cited by 393
Campuzano, I., Bush, M. F., Robinson, C. V., Beaumont, C., Richardson, K., Kim, H., & Kim, H. I. (2012) · Analytical Chemistry · doi:10.1021/ac202625t · Cited by 383
Enhancements in travelling wave ion mobility resolution
Giles, K., Williams, J. P., & Campuzano, I. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5013 · Cited by 369
von Helden, G., Wyttenbach, T., & Bowers, M. T. (1995) · Science · doi:10.1126/science.267.5203.1483 · Cited by 363
Peptides and Proteins in the Vapor Phase
Jarrold, M. F. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.179 · Cited by 361
Weston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Kolakowski, B. M., & Mester, Z. (2007) · The Analyst · doi:10.1039/b706039d · Cited by 351
Smith, D. P., Knapman, T. W., Campuzano, I., Malham, R. W., Berryman, J. T., Radford, S. E., & Ashcroft, A. E. (2009) · European Journal of Mass Spectrometry · doi:10.1255/ejms.947 · Cited by 334
Jurneczko, E., & Barran, P. E. (2011) · The Analyst · doi:10.1039/c0an00373e · Cited by 328
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Determination of the Effective Hydrodynamic Radii of Small Molecules by Viscometry
Schultz, S. G., & Solomon, A. K. (1961) · The Journal of General Physiology · doi:10.1085/jgp.44.6.1189 · Cited by 302
Design of a new electrospray ion mobility mass spectrometer
Wyttenbach, T., Kemper, P. R., & Bowers, M. T. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00517-6 · Cited by 277
Stolzenburg, M. R., & McMurry, P. H. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802157823 · Cited by 259
Collision cross sections for protein ions
Covey, T., & Douglas, D. J. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85025-s · Cited by 253
Measuring the Resolving Power of Ion Mobility Spectrometers
Siems, W. F., Wu, C., Tarver, E. E., Hill, H. H. J., Larsen, P. R., & McMinn, D. G. (1994) · Analytical Chemistry · doi:10.1021/ac00095a014 · Cited by 242
Thalassinos, K., Grabenauer, M., Slade, S. E., Hilton, G. R., Bowers, M. T., & Scrivens, J. H. (2009) · Analytical Chemistry · doi:10.1021/ac801916h · Cited by 240
Ion mobility spectrometry: a review. Part 1. Structural analysis by mobility measurement
Creaser, C. S., Griffiths, J. R., Bramwell, C. J., Noreen, S., Hill, C. A., & Thomas, C. L. P. (2004) · The Analyst · doi:10.1039/b404531a · Cited by 235
LXXIV. A positive ray spectrograph
Aston, F. W. (1919) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786441208636004 · Cited by 224
Weston, D. J., Bateman, R., Wilson, I. D., Wood, T. R., & Creaser, C. S. (2005) · Analytical Chemistry · doi:10.1021/ac051277q · Cited by 224
Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer
Guevremont, R., & Purves, R. W. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149599 · Cited by 218
Shelimov, K. B., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja962914k · Cited by 205
Henderson, S. C., Valentine, S. J., Counterman, A. E., & Clemmer, D. E. (1999) · Analytical Chemistry · doi:10.1021/ac9809175 · Cited by 203
A new, higher resolution, ion mobility mass spectrometer
Kemper, P. R., Dupuis, N. F., & Bowers, M. T. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.01.012 · Cited by 195
Poornima, C. S., & Dean, P. M. (1995) · Journal of Computer-Aided Molecular Design · doi:10.1007/bf00124321 · Cited by 190
Mapping the human plasma proteome by SCX-LC-IMS-MS
Liu, X., Valentine, S. J., Plasencia, M. D., Trimpin, S., Naylor, S., & Clemmer, D. E. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.04.012 · Cited by 187
Separation of Ions from Explosives in Differential Mobility Spectrometry by Vapor-Modified Drift Gas
Eiceman, G. A., Krylov, E. V., Krylova, N. S., Nazarov, E. G., & Miller, R. A. (2004) · Analytical Chemistry · doi:10.1021/ac035502k · Cited by 186
Equation for Peak Capacity Estimation in Two-Dimensional Liquid Chromatography
Li, X., Stoll, D. R., & Carr, P. W. (2009) · Analytical Chemistry · doi:10.1021/ac801772u · Cited by 182
Dwivedi, P., Bendiak, B., Clowers, B. H., & Hill, H. H. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.04.007 · Cited by 174
Chemical Effects in the Separation Process of a Differential Mobility/Mass Spectrometer System
Schneider, B. B., Covey, T. R., Coy, S. L., Krylov, E. V., & Nazarov, E. G. (2010) · Analytical Chemistry · doi:10.1021/ac902571u · Cited by 172
Metabolic profiling of human blood by high-resolution ion mobility mass spectrometry (IM-MS)
Dwivedi, P., Schultz, A. J., & Jr, H. H. H. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.02.007 · Cited by 168
Evidence for Many Resolvable Structures within Conformation Types of Electrosprayed Ubiquitin Ions
Koeniger, S. L., Merenbloom, S. I., & Clemmer, D. E. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp056165h · Cited by 165
Water, water everywhere — except where it matters?
Homans, S. W. (2007) · Drug Discovery Today · doi:10.1016/j.drudis.2007.05.004 · Cited by 159
Using Different Drift Gases To Change Separation Factors (α) in Ion Mobility Spectrometry
Asbury, G. R., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac9908952 · Cited by 158
Valentine, S. J., Kulchania, M., Barnes, C. A. S., & Clemmer, D. E. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00511-5 · Cited by 143
Structure of the 21–30 fragment of amyloid β‐protein
Baumketner, A., Bernstein, S. L., Wyttenbach, T., Lazo, N. D., Teplow, D. B., Bowers, M. T., & Shea, J. (2006) · Protein Science · doi:10.1110/ps.062076806 · Cited by 139
Hadamard Transform Ion Mobility Spectrometry
Clowers, B. H., Siems, W. F., Hill, H. H., et al. (2005) · Analytical Chemistry · doi:10.1021/ac050615k · Cited by 138
Hadamard Transform Ion Mobility Spectrometry
Szumlas, A. W., Ray, S. J., & Hieftje, G. M. (2006) · Analytical Chemistry · doi:10.1021/ac051743b · Cited by 134
Hogan, C. J., Ruotolo, B., Robinson, C., & de la Mora, J. F. (2011) · Journal of Physical Chemistry B · doi:10.1021/jp109172k · Cited by 127
Tunable selective detection for capillary gas chromatography by ion mobility monitoring
Baim, M. A., & Hill, H. H. (1982) · Analytical Chemistry · doi:10.1021/ac00238a013 · Cited by 124
IMS–MS studies based on coupling a differential mobility analyzer (DMA) to commercial API–MS systems
Rus, J., Moro, D., Sillero, J. A., Royuela, J., Casado, A., Estevez-Molinero, F., & de la Mora, J. F. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.05.008 · Cited by 123
Williams, J. P., Grabenauer, M., Holland, R. J., Carpenter, C. J., Wormald, M. R., Giles, K., Harvey, D. J., Bateman, R. H., Scrivens, J. H., & Bowers, M. T. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.08.006 · Cited by 121
Matz, L. M., & Hill, H. H. (2001) · Analytical Chemistry · doi:10.1021/ac010858m · Cited by 120
Clowers, B. H., Ibrahim, Y., Prior, D. C., Danielson, W., Belov, M. E., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac701648p · Cited by 116
Myung, S., Lee, Y., Moon, M. H., Taraszka, J. A., Robinson, R. A. S., Koeniger, S. L., Hilderbrand, A. E., Valentine, S. J., Cherbas, L., Cherbas, P. T., et al. (2003) · Analytical Chemistry · doi:10.1021/ac030107f · Cited by 113
Shvartsburg, A. A., Smith, R. D., Wilks, A. T., Koehl, A., Ruiz-Alonso, D., & Boyle, B. (2009) · Analytical Chemistry · doi:10.1021/ac900892u · Cited by 107
Modeling the resolution and sensitivity of FAIMS analyses
Shvartsburg, A. A., Tang, K., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.06.018 · Cited by 106
Pressure Effects in Differential Mobility Spectrometry
Nazarov, E. G., Coy, S. L., Krylov, E. V., Miller, R. A., & Eiceman, G. A. (2006) · Analytical Chemistry · doi:10.1021/ac061092z · Cited by 105
Allen, F. H., Harris, S. E., & Taylor, R. (1996) · Journal of Computer-Aided Molecular Design · doi:10.1007/bf00355046 · Cited by 105
Optimization of Algorithms for Ion Mobility Calculations
Shvartsburg, A. A., Mashkevich, S. V., Baker, E. S., & Smith, R. D. (2007) · The Journal of Physical Chemistry A · doi:10.1021/jp066953m · Cited by 102
Rand, K. D., Pringle, S. D., Murphy, J. P., Fadgen, K. E., Brown, J. M., & Engen, J. R. (2009) · Analytical Chemistry · doi:10.1021/ac901897x · Cited by 101
Javahery, G., & Thomson, B. A. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00027-5 · Cited by 100
Momentum-transfer cross section for electron-helium collisions in the range 4-12 eV
Milloy, H., & Crompton, R. W. (1977) · Physical Review A · doi:10.1103/physreva.15.1847 · Cited by 98
Purves, R. W., Barnett, D. A., Ells, B., & Guevremont, R. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00136-7 · Cited by 96
High-Resolution Differential Ion Mobility Separations Using Helium-Rich Gases
Shvartsburg, A. A., Danielson, W., & Smith, R. D. (2010) · Analytical Chemistry · doi:10.1021/ac902852a · Cited by 93
de Wainer, L. S., & Bassett, G. A. (1978) · Philosophical magazine. A/Philosophical magazine. A. Physics of condensed matter. Structure, defects and mechanical properties · doi:10.1080/01418617808239266 · Cited by 91
Wyttenbach, T., Paizs, B., Barran, P. E., Breci, L. A., Liu, D., Suhai, S., Wysocki, V. H., & Bowers, M. T. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037204a · Cited by 89
Charge-Induced Unfolding of Multiply Charged Polyethylene Glycol Ions
Ude, S., de la Mora, J. F., & Thomson, B. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0381306 · Cited by 84
A method for direct measurement of ion mobilities using a travelling wave ion guide
Giles, K., Wildgoose, J. L., Langridge, D., & Campuzano, I. D. G. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.10.008 · Cited by 84
Overtone mobility spectrometry: Part 1. Experimental observations
Kurulugama, R. T., Nachtigall, F. M., Lee, S., Valentine, S. J., & Clemmer, D. E. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.11.022 · Cited by 81
Canterbury, J. D., Yi, X., Hoopmann, M. R., & MacCoss, M. J. (2008) · Analytical Chemistry · doi:10.1021/ac8004988 · Cited by 80
Levin, D. S., Vouros, P., Miller, R. A., Nazarov, E. G., & Morris, J. C. (2005) · Analytical Chemistry · doi:10.1021/ac051217k · Cited by 80
Plasma chromatography of heroin and cocaine with mass-identified mobility spectra
Karasek, F. W., Hill, H. H., & Kim, S. H. (1976) · Journal of Chromatography A · doi:10.1016/0021-9673(76)80009-x · Cited by 79
Williams, J. P., Bugarcic, T., Habtemariam, A., Giles, K., Campuzano, I. D. G., Rodger, P. M., & Sadler, P. J. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.02.016 · Cited by 79
When proteomics meets structural biology
Zhou, M., & Robinson, C. V. (2010) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2010.04.007 · Cited by 78
Chemical standards in ion mobility spectrometry
Fernández‐Maestre, R., Harden, C. S., Ewing, R. G., Crawford, C. L., & Hill, H. H. (2010) · The Analyst · doi:10.1039/b915202d · Cited by 78
Ion mobility mass spectrometry for peptide analysis
Harvey, S. R., MacPhee, C. E., & Barran, P. E. (2011) · Methods · doi:10.1016/j.ymeth.2011.05.004 · Cited by 76
Dynamically Multiplexed Ion Mobility Time-of-Flight Mass Spectrometry
Belov, M. E., Clowers, B. H., Prior, D. C., Danielson, W., Liyu, A. V., Petritis, B. O., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac8003665 · Cited by 74
Dear, G. J., Muñoz, J. A., Beaumont, C., Roberts, A., Kirk, J. M., Williams, J. P., & Campuzano, I. D. G. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4742 · Cited by 73
D’Agostino, P. A., & Chenier, C. L. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4547 · Cited by 71
Conformational Sampling and Energetics of Drug-Like Molecules
Foloppe, N., & Chen, I. (2009) · Current Medicinal Chemistry · doi:10.2174/092986709789057680 · Cited by 71
Enders, J. R., & MCLEAN, J. A. J. (2009) · Chirality · doi:10.1002/chir.20806 · Cited by 65
Comparison of the planar and coaxial field asymmetrical waveform ion mobility spectrometer (FAIMS)
Krylov, E. V. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)01037-0 · Cited by 60
Levin, D. S., Vouros, P., Miller, R. A., & Nazarov, E. G. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.10.008 · Cited by 59
Howdle, M. D., Eckers, C., Laures, A. M. ‐., & Creaser, C. S. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.10.002 · Cited by 58
Clowers, B. H., & Hill, H. H. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.994 · Cited by 57
Shvartsburg, A. A., Tang, K., Smith, R. D., Holden, M., Rush, M., Thompson, A., & Toutoungi, D. E. (2009) · Analytical Chemistry · doi:10.1021/ac901479e · Cited by 56
Detection of pesticides from liquid matrices by ion mobility spectrometry
Tuovinen, K., Paakkanen, H., & Hänninen, O. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00697-2 · Cited by 55
Product ion mobility as a promising tool for assignment of positional isomers of drug metabolites
Cuyckens, F., Wassvik, C. M., Mortishire‐Smith, R. J., Tresadern, G., Campuzano, I. D. G., & Claereboudt, J. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5258 · Cited by 51
Overtone mobility spectrometry: Part 2. Theoretical considerations of resolving power
Valentine, S. J., Stokes, S. T., Kurulugama, R. T., Nachtigall, F. M., & Clemmer, D. E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.01.001 · Cited by 51
Using a buffer gas modifier to change separation selectivity in ion mobility spectrometry
Fernández‐Maestre, R., Wu, C., & Hill, H. H. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.08.009 · Cited by 44
Shvartsburg, A. A., Clemmer, D. E., & Smith, R. D. (2010) · Analytical Chemistry · doi:10.1021/ac101992d · Cited by 43
Taraszka, J. A., Gao, X., Valentine, S. J., Robinson, R. A. S., Koeniger, S. L., Miller, D. F., Kaufman, T. C., & Clemmer, D. E. (2005) · Journal of Proteome Research · doi:10.1021/pr050037o · Cited by 42
Role of the Dielectric Constants of Membrane Proteins and Channel Water in Ion Permeation
Baştuğ, T., & Kuyucak, S. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)70015-0 · Cited by 37
Howdle, M. D., Eckers, C., Laures, A. M. ‐., & Creaser, C. S. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.08.007 · Cited by 32
Likar, M. D., Cheng, G. C., Mahajan, N., & Zhang, Z. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.02.021 · Cited by 32
The Energy Landscape of Unsolvated Peptides: Helix Formation and Cold Denaturation in Ac-A4G7A4 + H+
Kinnear, B. S., Hartings, M. R., & Jarrold, M. F. (2002) · Journal of the American Chemical Society · doi:10.1021/ja012150v · Cited by 28
Mao, Y., Ratner, M. A., & Jarrold, M. F. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0030717 · Cited by 23
Probing Shapes of Bichromophoric Metal−Organic Complexes Using Ion Mobility Mass Spectrometry
Baker, E. S., Bushnell, J. E., Wecksler, S. R., Lim, M. D., Manard, M. J., Dupuis, N., Ford, P. C., & Bowers, M. T. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0553699 · Cited by 23
Real-time reaction monitoring using ion mobility-mass spectrometry
Harry, E. L., Bristow, A. W. T., Wilson, I. D., & Creaser, C. S. (2011) · The Analyst · doi:10.1039/c0an00700e · Cited by 21
Santos, L. F. A., Iglesias, A. H., Pilau, E. J., Gomes, A. F., & Gozzo, F. C. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2010.08.017 · Cited by 20
Ion mobility mass spectrometry: an elegant alternative focusing on speciation studies
Pessôa, G. D. S., Pilau, E. J., Gozzo, F. C., & Arruda, M. A. Z. (2010) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c0ja00139b · Cited by 13
Sinues, P., Criado-Hidalgo, E., Vidal‐de‐Miguel, G., Cristoni, S., Franzoso, F., Piatti, M., & Brambilla, P. (2011) · Metabolomics · doi:10.1007/s11306-011-0319-y · Cited by 12
Cited by
Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics
Blaženović, I., Kind, T., Ji, J., & Fiehn, O. (2018) · Metabolites · doi:10.3390/metabo8020031 · Cited by 757
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Ion Mobility Derived Collision Cross Sections to Support Metabolomics Applications
Paglia, G., Williams, J. P., Menikarachchi, L., Thompson, J. W., Tyldesley-Worster, R., Halldórsson, S., Rolfsson, O., Moseley, A., Grant, D., Langridge, J., et al. (2014) · Analytical Chemistry · doi:10.1021/ac500405x · Cited by 319
Advances in mass spectrometry-based metabolomics for investigation of metabolites
Ren, J.-L., Zhang, A.-H., Kong, L., & Wang, X.-J. (2018) · RSC Advances · doi:10.1039/c8ra01574k · Cited by 291
Metadata
- Authors
- Lapthorn, C., Pullen, F., & Chowdhry, B. Z.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2012-08-31
- Volume
- 32
- Issue
- 1
- Pages
- 43-71
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2020833381
- Cited by
- 398
- References
- 105
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.