The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Abstract
This paper is devoted to a theory of the NMR signal behavior in biological tissues in the presence of static magnetic field inhomogeneities. We have developed an approach that analytically describes the NMR signal in the static dephasing regime where diffusion phenomena may be ignored. This approach has been applied to evaluate the NMR signal in the presence of a blood vessel network (with an application to functional imaging), bone marrow (for two specific trabecular structures, asymmetrical and columnar) and a ferrite contrast agent. All investigated systems have some common behavior. If the echo time TE is less than a known characteristic time tc for a given system, then the signal decays exponentially with an argument which depends quadratically on TE. This is equivalent to an R2* relaxation rate which is a linear function of TE. In the opposite case, when TE is greater than tc, the NMR signal follows a simple exponential decay and the relaxation rate does not depend on the echo time. For this time interval, R2* is a linear function of a) volume fraction ζ occupied by the field‐creating objects, b) magnetic field B 0 or just the objects' magnetic moment for ferrite particles, and c) susceptibility difference Δχ between the objects and the medium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Bloch Equations with Diffusion Terms
Torrey, H. C. (1956) · Physical Review · doi:10.1103/physrev.104.563 · Cited by 1,216
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Intravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524
Susceptibility artefacts in NMR imaging
Lüdeke, K. M., Röschmann, P., & Tischler, R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90397-2 · Cited by 445
Echo‐planar time course MRI of cat brain oxygenation changes
Turner, R., Bihan, D. L., Moonen, C. T. W., Despres, D., & Frank, J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220117 · Cited by 421
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Self-citationWeisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Gillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Ogawa, S., Lee, T. M., & Barrere, B. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290208 · Cited by 281
Ferrite particles: a superparamagnetic MR contrast agent for the reticuloendothelial system.
Saini, S., Stark, D. D., Hahn, P. F., Wittenberg, J., Brady, T. J., & Ferrucci, J. T. (1987) · Radiology · doi:10.1148/radiology.162.1.3786765 · Cited by 230
A model of vertebral trabecular bone architecture and its mechanical properties
Jensen, K. S., Mosekilde, L., & Mosekilde, L. (1990) · Bone · doi:10.1016/8756-3282(90)90137-n · Cited by 180
Interpretation of water nuclear magnetic resonance relaxation times in heterogeneous systems
Glasel, J. A., & Lee, K. H. (1974) · Journal of the American Chemical Society · doi:10.1021/ja00811a003 · Cited by 178
Transverse relaxivity of particulate MRI contrast media: From theories to experiments
Muller, R. N., Gillis, P., Moiny, F., & Roch, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220203 · Cited by 171
Haacke, E. M., Hopkins, A., Lai, S., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., Friedland, R., Klein, S., Thompson, L., et al. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070109 · Cited by 167
Self-citationStudies of diffusion in random fields produced by variations in susceptibility
Majumdar, S., & Gore, J. C. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90155-2 · Cited by 161
Trabecular structure: preliminary application of MR interferometry.
Wehrli, F. W., Ford, J. C., Attie, M., Kressel, H. Y., & Kaplan, F. S. (1991) · Radiology · doi:10.1148/radiology.179.3.2027962 · Cited by 154
Basic physics of MR contrast agents and maximization of image contrast
Hendrick, R. E., & Haacke, E. M. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030126 · Cited by 151
Self-citationRelationship between NMR transverse relaxation, trabecular bone architecture, and strength.
Chung, H., Wehrli, F. W., Williams, J. L., & Kugelmass, S. D. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.10250 · Cited by 145
Reduction of T2* dephasing in gradient field-echo imaging.
Haacke, E. M., Tkach, J. A., & Parrish, T. B. (1989) · Radiology · doi:10.1148/radiology.170.2.2911669 · Cited by 134
Self-citationMagnetic Resonance Imaging Mapping of Brain Function: Human Visual Cortex
Belliveau, J. W., Kwong, K. K., Kennedy, D. N., BAKER, J. R., Stern, C. E., Benson, R. R., Chesler, D. A., Weisskoff, R. M., Cohen, M. S., Tootell, R. B. H., et al. (1992) · Investigative Radiology · doi:10.1097/00004424-199212002-00011 · Cited by 133
Osteoporosis. Current techniques and recent developments in quantitative bone densitometry.
Lang, P. K., Steiger, P., Faulkner, K. G., Glüer, C.-C., & Genant, H. K. (1991) · PubMed · Cited by 118
Brown, R. J. S. (1961) · Physical Review · doi:10.1103/physrev.121.1379 · Cited by 114
Scanning electron microscope studies of trabecular bone in the proximal end of the human femur.
Whitehouse, W. J., & Dyson, E. D. (1974) · PubMed Central · Cited by 108
Majumdar, S., & Genant, H. K. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020215 · Cited by 108
Transverse relaxation rate enhancement caused by magnetic particulates
Hardy, P., & Henkelman, R. M. (1989) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(89)90549-3 · Cited by 92
In vivo Quantitative characterization of trabecular bone by NMR
Ford, J. C., & Wehrli, F. W. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170225 · Cited by 88
Magnetic field distribution in models of trabecular bone
Ford, J. C., Wehrli, F. W., & Chung, H. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300316 · Cited by 86
Magnetite albumin microspheres: a new MR contrast material
Widder, D., Greif, W. L., Kj, W., et al. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.2.399 · Cited by 66
Majumdar, S. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220111 · Cited by 62
Scanning Electron Microscope Studies of Human Trabecular Bone
Dyson, E. D., Jackson, C., & Whitehouse, W. J. (1970) · Nature · doi:10.1038/225957a0 · Cited by 46
Dextran magnetite as a liver contrast agent
Magin, R. L., Bacic, G., Niesman, M. R., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200102 · Cited by 39
Scanning electron micrographs of cancellous bone from the human sternum
Whitehouse, W. J. (1975) · The Journal of Pathology · doi:10.1002/path.1711160405 · Cited by 28
Cited by
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Magnetic Nanoparticles: Surface Effects and Properties Related to Biomedicine Applications
Issa, B., Obaidat, I., Albiss, B., & Haik, Y. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141121266 · Cited by 1,245
Modeling the hemodynamic response to brain activation
Buxton, R. B., Uludağ, K., Dubowitz, D. J., & Liu, T. T. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.013 · Cited by 1,229
Calibrated functional MRI: Mapping the dynamics of oxidative metabolism
Davis, T. L., Kwong, K. K., Weisskoff, R. M., & Rosen, B. R. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1834 · Cited by 1,052
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Self-citation
Metadata
- Authors
- Yablonskiy, D. A., & Haacke, E. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1994-12
- Volume
- 32
- Issue
- 6
- Pages
- 749-763
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2064533924
- Cited by
- 1,198
- References
- 45
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.