The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments
Open accessAbstract
Chemical exchange saturation transfer (CEST) is a contrast mechanism that exploits exchange‐based magnetization transfer (MT) between solute and water protons. CEST effects compete with direct water saturation and conventional MT processes, and generally can only be quantified through an asymmetry analysis of the water saturation spectrum (Z‐spectrum) with respect to the water frequency, a process that is exquisitely sensitive to magnetic field inhomogeneities. Here it is shown that direct water saturation imaging allows measurement of the absolute water frequency in each voxel, allowing proper centering of Z‐spectra on a voxel‐by‐voxel basis independently of spatial B0 field variations. Optimal acquisition parameters for this “water saturation shift referencing” (WASSR) approach were estimated using Monte Carlo simulations and later confirmed experimentally. The optimal ratio of the WASSR sweep width to the linewidth of the direct saturation curve was found to be 3.3–4.0, requiring a sampling of 16–32 points. The frequency error was smaller than 1 Hz at signal‐to‐noise ratios of 40 or higher. The WASSR method was applied to study glycogen, where the chemical shift difference between the hydroxyl (OH) protons and bulk water protons at 3T is so small (0.75–1.25 ppm) that the CEST spectrum is inconclusive without proper referencing. Magn Reson Med, 2008. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Convergence Properties of the Nelder--Mead Simplex Method in Low Dimensions
Lagarias, J. C., Reeds, J. A., Wright, M. H., & Wright, P. E. (1998) · SIAM Journal on Optimization · doi:10.1137/s1052623496303470 · Cited by 7,447
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Ward, K. M., Aletras, A. H., & Balaban, R. S. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1956 · Cited by 1,429
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
Self-citationMagnusson, I., Rothman, D. L., Katz, L. D., Shulman, R. G., & Shulman, G. I. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115997 · Cited by 757
Cline, G. W., Petersen, K. F., Krssak, M., Shen, J., Hundal, R. S., Trajanoski, Z., Inzucchi, S., Dresner, A., Rothman, D. L., & Shulman, G. I. (1999) · New England Journal of Medicine · doi:10.1056/nejm199907223410404 · Cited by 675
Amide proton transfer (APT) contrast for imaging of brain tumors
Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10651 · Cited by 660
Self-citationLing, W., Regatte, R. R., Navon, G., & Jerschow, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707666105 · Cited by 533
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Self-citationPARACEST Agents: Modulating MRI Contrast via Water Proton Exchange
Zhang, S., Merritt, M., Woessner, D. E., Lenkinski, R. E., & Sherry, A. D. (2003) · Accounts of Chemical Research · doi:10.1021/ar020228m · Cited by 436
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Self-citationChallenges for Molecular Magnetic Resonance Imaging
Terreno, E., Castelli, D. D., Viale, A., & Aime, S. (2010) · Chemical Reviews · doi:10.1021/cr100025t · Cited by 855
Magnetic resonance imaging of glutamate
Cai, K., Haris, M., Singh, A., Kogan, F., Greenberg, J. H., Hariharan, H., Detre, J. A., & Reddy, R. (2012) · Nature Medicine · doi:10.1038/nm.2615 · Cited by 660
APT‐weighted MRI: Techniques, current neuro applications, and challenging issues
Zhou, J., Heo, H., Knutsson, L., van Zijl, P. C. M., & Jiang, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26645 · Cited by 345
Self-citationvan Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationNatural D ‐glucose as a biodegradable MRI contrast agent for detecting cancer
Chan, K. W. Y., McMahon, M. T., Kato, Y., Liu, G., Bulte, J. W. M., Bhujwalla, Z. M., Artemov, D., & van Zijl, P. C. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24520 · Cited by 337
Self-citationZaiss, M., & Bachert, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/r221 · Cited by 323
Nuts and bolts of chemical exchange saturation transfer MRI
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2899 · Cited by 318
Zaiss, M., Xu, J., Goerke, S., Khan, I. S., Singer, R. J., Gore, J. C., Gochberg, D. F., & Bachert, P. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3054 · Cited by 316
Clinical applications of chemical exchange saturation transfer (CEST) MRI
Jones, K. M., Pollard, A. C., & Pagel, M. D. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25838 · Cited by 287
An overview of CEST MRI for non-MR physicists
Wu, B., Warnock, G., Zaiss, M., Lin, C., Chen, M., Zhou, Z., Mu, L., Nanz, D., Tuura, R., & Delso, G. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0155-2 · Cited by 274
Jin, T., Wang, P., Zong, X., & Kim, S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24315 · Cited by 273
In vivo mapping of brain myo-inositol
Haris, M., Cai, K., Singh, A., Hariharan, H., & Reddy, R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.017 · Cited by 253
Imaging brain deoxyglucose uptake and metabolism by glucoCEST MRI
Nasrallah, F. A., Pagès, G., Kuchel, P. W., Golay, X., & Chuang, K.-H. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.79 · Cited by 179
Noninvasive Detection of Extracellular pH in Human Benign and Malignant Liver Tumors Using CEST MRI
Tang, Y., Xiao, G., Shen, Z., Zhuang, C., Xie, Y., Zhang, X., Yang, Z., Guan, J., Shen, Y., Chen, Y., et al. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.578985 · Cited by 56
High Resolution T1ρ Mapping of In Vivo Human Knee Cartilage at 7T
Singh, A., Haris, M., Cai, K., Kogan, F., Hariharan, H., & Reddy, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0097486 · Cited by 48
Lee, D.-W., Heo, H., Woo, C.-W., Woo, D.-C., Kim, J.-K., Kim, K.-W., & Lee, D.-H. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21249468 · Cited by 9
Metadata
- Authors
- Kim, M., Gillen, J., Landman, B. A., Zhou, J., & van Zijl, P. C. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-04-08
- Volume
- 61
- Issue
- 6
- Pages
- 1441-1450
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2074136578
- Cited by
- 691
- References
- 31
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.