The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Magnetic nanoparticle biosensors
Abstract
One of the major challenges in medicine is the rapid and accurate measurement of protein biomarkers, cells, and pathogens in biological samples. A number of new diagnostic platforms have recently been developed to measure biomolecules and cells with high sensitivity that could enable early disease detection or provide valuable insights into biology at the systems level. Most biological samples exhibit negligible magnetic susceptibility; therefore, magnetic nanoparticles have been used for diverse applications including biosensing, magnetic separation, and thermal ablation therapy. This review focuses on the use of magnetic nanoparticles for detection of biomolecules and cells based on magnetic resonance effects using a general detection platform termed diagnostic magnetic resonance (DMR). DMR technology encompasses numerous assay configurations and sensing principles, and to date magnetic nanoparticle biosensors have been designed to detect a wide range of targets including DNA/mRNA, proteins, enzymes, drugs, pathogens, and tumor cells. The core principle behind DMR is the use of magnetic nanoparticles as proximity sensors that modulate the spin‐spin relaxation time of neighboring water molecules, which can be quantified using clinical MRI scanners or benchtop nuclear magnetic resonance (NMR) relaxometers. Recently, the capabilities of DMR technology were advanced considerably with the development of miniaturized, chip‐based NMR (µNMR) detector systems that are capable of performing highly sensitive measurements on microliter sample volumes and in multiplexed format. With these and future advances in mind, DMR biosensor technology holds considerable promise to provide a high‐throughput, low‐cost, and portable platform for large scale molecular and cellular screening in clinical and point‐of‐care settings. WIREs Nanomed Nanobiotechnol 2010 2 291–304 This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > In Vitro Nanoparticle-Based Sensing
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Giant tunnelling magnetoresistance at room temperature with MgO (100) tunnel barriers
Parkin, S. S. P., Kaiser, C., Panchula, A., Rice, P. M., Hughes, B., Samant, M., & Yang, S.-H. (2004) · Nature Materials · doi:10.1038/nmat1256 · Cited by 3,320
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Self-citationArtificially engineered magnetic nanoparticles for ultra-sensitive molecular imaging
Lee, J.-H., Huh, Y.-M., Jun, Y.-W., Seo, J.-W., Jang, J.-T., Song, H.-T., Kim, S., Cho, E.-J., Yoon, H.-G., Suh, J.-S., et al. (2007) · Nature Medicine · doi:10.1038/nm1467 · Cited by 1,897
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Jun, Y.-W., Huh, Y.-M., Choi, J.-S., Lee, J.-H., Song, H.-T., Kim, S., Yoon, S., Kim, K.-S., Shin, J.-S., Suh, J.-S., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0422155 · Cited by 1,193
Prognostic Value of Myeloperoxidase in Patients with Chest Pain
Brennan, M.-L., Penn, M. S., Van Lente, F., Nambi, V., Shishehbor, M. H., Aviles, R. J., Goormastic, M., Pepoy, M. L., McErlean, E. S., Topol, E. J., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035003 · Cited by 1,070
Association Between Myeloperoxidase Levels and Risk of Coronary Artery Disease
Zhang, R. (2001) · JAMA · doi:10.1001/jama.286.17.2136 · Cited by 918
Magnetic relaxation switches capable of sensing molecular interactions
Perez, J. M., Josephson, L., O'Loughlin, T., Högemann, D., & Weissleder, R. (2002) · Nature Biotechnology · doi:10.1038/nbt720 · Cited by 889
Self-citationHigh-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882
Self-citationIn Vivo Magnetic Resonance Detection of Cancer by Using Multifunctional Magnetic Nanocrystals
Huh, Y.-M., Jun, Y.-W., Song, H.-T., Kim, S., Choi, J.-S., Lee, J.-H., Yoon, S., Kim, K.-S., Shin, J.-S., Suh, J.-S., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052337c · Cited by 859
Patolsky, F., Timko, B. P., Yu, G., Fang, Y., Greytak, A. B., Zheng, G., & Lieber, C. M. (2006) · Science · doi:10.1126/science.1128640 · Cited by 832
A biosensor based on magnetoresistance technology
Baselt, D. R., Lee, G. U., Natesan, M., Metzger, S. W., Sheehan, P. E., & Colton, R. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00037-2 · Cited by 823
Chip–NMR biosensor for detection and molecular analysis of cells
Lee, H., Sun, E., Ham, D., & Weissleder, R. (2008) · Nature Medicine · doi:10.1038/nm.1711 · Cited by 621
Self-citationSynthesis and Stabilization of Monodisperse Fe Nanoparticles
Peng, S., Wang, C., Xie, J., & Sun, S. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063969h · Cited by 531
Perez, J. M., Simeone, F. J., Saeki, Y., Josephson, L., & Weissleder, R. (2003) · Journal of the American Chemical Society · doi:10.1021/ja036409g · Cited by 517
Self-citationMolecular Imaging Using a Targeted Magnetic Resonance Hyperpolarized Biosensor
Schröder, L., Lowery, T. J., Hilty, C., Wemmer, D. E., & Pines, A. (2006) · Science · doi:10.1126/science.1131847 · Cited by 488
Ultrasensitive magnetic biosensor for homogeneous immunoassay
Chemla, Y. R., Grossman, H. L., Poon, Y., McDermott, R., Stevens, R., Alper, M. D., & Clarke, J. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.26.14268 · Cited by 421
Magnetic Nanosensors for the Detection of Oligonucleotide Sequences
Josephson, L., Perez, J. M., & Weissleder, R. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010903)40:17<3204::aid-anie3204>3.0.co;2-h · Cited by 380
Self-citationPerez, J. M., O'Loughin, T., Simeone, F. J., Weissleder, R., & Josephson, L. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017773n · Cited by 355
Self-citationHeath, J. R., & Davis, M. E. (2008) · Annual Review of Medicine · doi:10.1146/annurev.med.59.061506.185523 · Cited by 354
Sha, M. Y., Xu, H., Natan, M. J., & Cromer, R. (2008) · Journal of the American Chemical Society · doi:10.1021/ja804494m · Cited by 320
Magnetic resonance relaxation properties of superparamagnetic particles
Gossuin, Y., Gillis, P., Hocq, A., Vuong, Q. L., & Roch, A. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.36 · Cited by 319
Plasmon light scattering in biology and medicine: new sensing approaches, visions and perspectives
Aslan, K., Lakowicz, J. R., & Geddes, C. D. (2005) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2005.08.021 · Cited by 302
Multiplex protein assays based on real-time magnetic nanotag sensing
Osterfeld, S. J., Yu, H., Gaster, R. S., Caramuta, S., Xu, L., Han, S.-J., Hall, D. A., Wilson, R. J., Sun, S., White, R. L., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810822105 · Cited by 288
On T2‐shortening by strongly magnetized spheres: A partial refocusing model
Gillis, P., Moiny, F., & Brooks, R. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10059 · Cited by 270
Use of magnetic nanoparticles as nanosensors to probe for molecular interactions
Perez, J. M., Josephson, L., & Weissleder, R. (2004) · ChemBioChem · doi:10.1002/cbic.200300730 · Cited by 268
Self-citation18F Labeled Nanoparticles for in Vivo PET-CT Imaging
Devaraj, N. K., Keliher, E. J., Thurber, G. M., Nahrendorf, M., & Weissleder, R. (2009) · Bioconjugate Chemistry · doi:10.1021/bc8004649 · Cited by 245
Self-citationAtanasijevic, T., Shusteff, M., Fam, P., & Jasanoff, A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606749103 · Cited by 242
Magnetic Sensors for Protease Assays
Zhao, M., Josephson, L., Tang, Y., & Weissleder, R. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390352 · Cited by 223
Self-citationLi, G., Sun, S., Wilson, R. J., White, R. L., Pourmand, N., & Wang, S. X. (2006) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.10.001 · Cited by 216
One-Step, Nanoparticle-Mediated Bacterial Detection with Magnetic Relaxation
Kaittanis, C., Naser, S. A., & Perez, J. M. (2007) · Nano Letters · doi:10.1021/nl062553z · Cited by 214
Magnetic labeling, detection, and system integration
Tamanaha, C. R., Mulvaney, S. P., Rife, J. C., & Whitman, L. J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.009 · Cited by 205
Ultrasensitive Detection of Bacteria Using Core–Shell Nanoparticles and an NMR‐Filter System
Lee, H., Yoon, T., & Weissleder, R. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901791 · Cited by 196
Self-citationRapid detection and profiling of cancer cells in fine-needle aspirates
Lee, H., Yoon, T.-J., Figueiredo, J.-L., Swirski, F. K., & Weissleder, R. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902365106 · Cited by 187
Self-citationNovel Nanosensors for Rapid Analysis of Telomerase Activity
Grimm, J., Perez, J. M., Josephson, L., & Weissleder, R. (2004) · Cancer Research · doi:10.1158/0008-5472.can-03-2798 · Cited by 166
Self-citationSQUID based remanence measurements for immunoassays
Kötitz, R., Matz, H., Trahms, L., Koch, H., Weitschies, W., Rheinländer, T., Semmler, W., & Bunte, T. (1997) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.622216 · Cited by 146
High Throughput Magnetic Resonance Imaging for Evaluating Targeted Nanoparticle Probes
Högemann, D., Ntziachristos, V., Josephson, L., & Weissleder, R. (2002) · Bioconjugate Chemistry · doi:10.1021/bc015549h · Cited by 136
Self-citationPeroxidase Substrate Nanosensors for MR Imaging
Pérez, J. M. S., Simeone, F. J., Tsourkas, A., Josephson, L., & Weissleder, R. (2003) · Nano Letters · doi:10.1021/nl034983k · Cited by 135
Self-citationMagnetic Relaxation Switch Immunosensors Detect Enantiomeric Impurities
Tsourkas, A., Hofstetter, O., Hofstetter, H., Weissleder, R., & Josephson, L. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200352998 · Cited by 129
Self-citationT2‐shortening by strongly magnetized spheres: A chemical exchange model†
Brooks, R. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10064 · Cited by 119
Development of Nanoparticle Libraries for Biosensing
Sun, E. Y., Josephson, L., Kelly, K. A., & Weissleder, R. (2005) · Bioconjugate Chemistry · doi:10.1021/bc050290e · Cited by 109
Self-citationComparative Analysis of Nanoparticle-Antibody Conjugations: Carbodiimide Versus Click Chemistry
Thorek, D. L. J., Elias, E. R., & Tsourkas, A. (2009) · Molecular Imaging · doi:10.2310/7290.2009.00021 · Cited by 105
“Clickable” Nanoparticles for Targeted Imaging
Sun, E. Y., Josephson, L., & Weissleder, R. (2006) · Molecular Imaging · doi:10.2310/7290.2006.00013 · Cited by 90
Self-citationSensitive NMR Sensors Detect Antibodies to Influenza
Koh, I., Hong, R., Weissleder, R., & Josephson, L. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800069 · Cited by 86
Self-citationNanoparticle−Target Interactions Parallel Antibody−Protein Interactions
Koh, I., Hong, R., Weissleder, R., & Josephson, L. (2009) · Analytical Chemistry · doi:10.1021/ac802717c · Cited by 83
Self-citationContinuous Analyte Sensing with Magnetic Nanoswitches
Sun, E. Y., Weissleder, R., & Josephson, L. (2006) · Small · doi:10.1002/smll.200600204 · Cited by 71
Self-citationImplantable diagnostic device for cancer monitoring
Daniel, K. D., Kim, G., Vassiliou, C. C., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.010 · Cited by 65
Magnetic Relaxation Switch Detection of Human Chorionic Gonadotrophin
Kim, G., Josephson, L., Langer, R., & Cima, M. J. (2007) · Bioconjugate Chemistry · doi:10.1021/bc070110w · Cited by 64
CMOS Mini Nuclear Magnetic Resonance System and its Application for Biomolecular Sensing
Liu, Y., Sun, N., Lee, H., Weissleder, R., & Ham, D. (2008) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2008.4523096 · Cited by 60
Self-citationMulti-reservoir device for detecting a soluble cancer biomarker
Daniel, K. D., Kim, G., Vassiliou, C. C., Jalali‐Yazdi, F., Langer, R., & Cima, M. J. (2007) · Lab on a Chip · doi:10.1039/b705143c · Cited by 42
Integrated Nanosensors to Determine Levels and Functional Activity of Human Telomerase
Pérez, J. M. S., Grimm, J., Josephson, L., & Weissleder, R. (2008) · Neoplasia · doi:10.1593/neo.08350 · Cited by 39
Self-citationElectrode Chemistry Yields a Nanoparticle-Based NMR Sensor for Calcium
Taktak, S., Weissleder, R., & Josephson, L. (2008) · Langmuir · doi:10.1021/la8006298 · Cited by 37
Self-citation
Cited by
A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors
Naresh, V., & Lee, N. (2021) · Sensors · doi:10.3390/s21041109 · Cited by 2,066
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Wu, W., Wu, Z., Yu, T., Jiang, C., & Kim, W.-S. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/2/023501 · Cited by 1,574
Recent advances in graphene-based biosensors
Kuila, T., Bose, S., Khanra, P., Mishra, A. K., Kim, N. H., & Lee, J. H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.039 · Cited by 1,329
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Metadata
- Authors
- Haun, J. B., Yoon, T., Lee, H., & Weissleder, R.
- Venue
- WIREs Nanomedicine and Nanobiotechnology
- Publisher
- Wiley
- Published
- 2010-04-05
- Volume
- 2
- Issue
- 3
- Pages
- 291-304
- ISSN
- 1939-0041 (ISSN-L)
- 1939-5116
- OpenAlex
- W2018648183
- Cited by
- 550
- References
- 58
- FWCI
- 21.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.