MR Spectroscopy and Spectroscopic Imaging of the Brain
Open accessThe DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Abstract
Magnetic resonance spectroscopy (MRS) and the related technique of magnetic resonance spectroscopic imaging (MRSI) are widely used in both clinical and preclinical research for the non-invasive evaluation of brain metabolism. They are also used in medical practice, although their ultimate clinical value continues to be a source of discussion. This chapter reviews the general information content of brain spectra and commonly used protocols for both MRS and MRSI and also touches on data analysis methods and quantitation. The main focus is on proton MRS for application in humans, but many of the methods are also applicable to other nuclei and studies of animal models as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“Parallel Encoded-MRSI—Parallel imaging techniques originally developed for speeding up MRI can also be adopted for MRSI (85, 86).”
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Principles of Nuclear Magnetic Resonance in One and Two Dimensions
Ernst, R. R., Bodenhausen, G., Wokaun, A., & Redfield, A. G. (1989) · Physics Today · doi:10.1063/1.2811094 · Cited by 4,201 · cited 1×
“Four or five such slices interleaved can result in a TR prohibitively long that causes long scan times (67).”
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655 · cited 1×
“The LCModel fits the in vivo spectrum as a combination of pure, model spectra from each of the expected compounds in the brain (107).”
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142 · cited 1×
“Parallel Encoded-MRSI—Parallel imaging techniques originally developed for speeding up MRI can also be adopted for MRSI (85, 86).”
Hwang, T. L., & Shaka, A. J. (1995) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1995.1047 · Cited by 1,898 · cited 1×
“Since a single HS 180° pulse with a slice-selection gradient produces a large first-order phase variation across the spectrum, two consecutive HS pulses are needed to cancel it out (63, 64).”
Proton NMR chemical shifts and coupling constants for brain metabolites
Govindaraju, V., Young, K., & Maudsley, A. A. (2000) · NMR in Biomedicine · doi:10.1002/1099-1492(200005)13:3<129::aid-nbm619>3.0.co;2-v · Cited by 1,689 · cited 1×
“1, and a complete list of metabolite structures and their spectra can be found in (8).”
Principles of Nuclear Magnetic Resonance in One and Two Dimensions
Ernst, R. R., Bodenhausen, G., & Wokaun, A. (1990) · doi:10.1093/oso/9780198556473.001.0001 · Cited by 1,418
Magistretti, P. J., Pellerin, L., Rothman, D. L., & Shulman, R. G. (1999) · Science · doi:10.1126/science.283.5401.496 · Cited by 1,170
1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015 · cited 1×
“, the “MEGA” or “BASING” sequences) (99, 100).”
In vivo1H NMR spectroscopy of rat brain at 1 ms echo time
Tk�?, I., Star?uk, Z., Choi, I.-Y., & Gruetter, R. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199904)41:4<649::aid-mrm2>3.0.co;2-g · Cited by 1,005 · cited 3×
“This sequence is a promising technique to investigate compounds with short T2s in vivo.”
Proton nuclear magnetic resonance spectroscopy unambiguously identifies different neural cell types
Urenjak, J., Williams, Sr., Gadian, D., & Noble, M. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-03-00981.1993 · Cited by 995 · cited 1×
“In vitro, glial cells contain a two-to fourfold higher concentration of creatine than do neurons (23).”
The Return of the Frequency Sweep: Designing Adiabatic Pulses for Contemporary NMR
Garwood, M., & DelaBarre, L. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2340 · Cited by 952
Multinuclear NMR Studies on the Energy Metabolism of Glial and Neuronal Cells
Brand, A., Richter-Landsberg, C., & Leibfritz, D. (1993) · Developmental Neuroscience · doi:10.1159/000111347 · Cited by 884 · cited 1×
“Glial cells in vitro have been shown to contain higher levels of mI than neurons (29, 30).”
Localized proton spectroscopy using stimulated echoes
Frahm, J., Merboldt, K.-D., & Hänicke, W. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90154-5 · Cited by 826
Image-selected in Vivo spectroscopy (ISIS). A new technique for spatially selective nmr spectroscopy
Ordidge, R. J., Connelly, A., & Lohman, J. A. B. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90031-4 · Cited by 811 · cited 1×
“The slice-selective inversion pulse is applied to every other TR (similar to what is used in the “ISIS” experiment (66)) so that a minimum of two scans are required to achieve full spatial localization.”
WET, a T1- and B1-Insensitive Water-Suppression Method for in Vivo Localized 1H NMR Spectroscopy
Ogg, R. J., Kingsley, R. B., & Taylor, J. S. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1048 · Cited by 732 · cited 2×
“Multiple CHESS pulses with optimized flip angles and delays can be used to give good suppression factors over a range of transmit B1 values and water T1 relaxation times (which is important for the suppression of both brain water and CSF) (97, 98).”
Immunocytochemical localization of N-acetyl-aspartate with monoclonal antibodies
Simmons, M. L., Frondoza, C. G., & Coyle, J. T. (1991) · Neuroscience · doi:10.1016/0306-4522(91)90101-s · Cited by 626 · cited 1×
“NAA is often referred to as a “neuronal marker,” since immunocytochemical studies have suggested that NAA is predominantly restricted to neurons, axons, and dendrites within the central nervous system (12).”
Localized 1H NMR measurements of gamma-aminobutyric acid in human brain in vivo.
Rothman, D. L., Petroff, O. A., Behar, K. L., & Mattson, R. H. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5662 · Cited by 509 · cited 3×
“TR 2 s, voxel size 3.5×3.5×3.5 = ~43 cm3, centered on the anterior cingulate gyrus, with TE 68 ms for GABA and 130 ms for GSH. Scan time was 8 min 32 s for GABA and 17 min 4 s for GSH. Note that in (a) glutamate/glutamine (Glx) coedit with GABA, and in (b) the aspartyl resonances of NAA coedit with GSH. Methods Mol Bi…”
InfluentialUrenjak, J., Williams, S. R., Gadian, D. G., & Noble, M. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb08875.x · Cited by 503
Evidence of elevated glutamate in multiple sclerosis using magnetic resonance spectroscopy at 3 T
Srinivasan, R., Sailasuta, N., Hurd, R., Nelson, S., & Pelletier, D. (2005) · Brain · doi:10.1093/brain/awh467 · Cited by 465 · cited 1×
“Glu has been found to be elevated inMS plaques (36), and elevated cerebral Gln is commonly observed in patients with liver failure (for example, hepatic encephalopathy (31) and Reye’s syndrome (37)).”
In vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394 · cited 1×
“0 T and above), Glu and Gln become better resolved and can be quantified individually with good accuracy using appropriate spectral analysis techniques (35).”
Multisection proton MR spectroscopic imaging of the brain.
Duyn, J. H., Gillen, J., Sobering, G., van Zijl, P. C., & Moonen, C. T. (1993) · Radiology · doi:10.1148/radiology.188.1.8511313 · Cited by 356 · cited 3×
“5) and which can be used in a multi-slice mode (53).”
Kreis, R., Ross, B. D., Farrow, N. A., & Ackerman, Z. (1992) · Radiology · doi:10.1148/radiology.182.1.1345760 · Cited by 351 · cited 2×
“Low brain Cho has been observed in hepatic encephalopathy (21), and there is also some evidence to suggest that dietary intake of choline can modulate cerebral Cho levels (22).”
Mekle, R., Mlynárik, V., Gambarota, G., Hergt, M., Krueger, G., & Gruetter, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21961 · Cited by 324
Proton MR Spectroscopy of Intracranial Tumours: In Vivo and In Vitro Studies
Gill, S. S., Thomas, D. G. T., Bruggen, N. V., Gadian, D. G., Peden, C. J., Bell, J. D., Cox, I. J., Menon, D. K., Iles, R. A., Bryant, D. J., et al. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199007000-00001 · Cited by 307 · cited 13×
“Low brain Cho has been observed in hepatic encephalopathy (21), and there is also some evidence to suggest that dietary intake of choline can modulate cerebral Cho levels (22).”
InfluentialProbable Alzheimer disease: diagnosis with proton MR spectroscopy.
Shonk, T. K., Moats, R. A., Gifford, P., Michaelis, T., Mandigo, J. C., Izumi, J., & Ross, B. D. (1995) · Radiology · doi:10.1148/radiology.195.1.7892497 · Cited by 299 · cited 1×
“mI has been reported to be reduced in hepatic encephalopathy (31), and increased in Alzheimer’s dementia (32) and demyelinating diseases (33).”
Scheenen, T. W. J., Klomp, D. W. J., Wijnen, J. P., & Heerschap, A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21302 · Cited by 293 · cited 1×
“2d) or its simplified version “semi-LASER” (61, 62) (Fig.”
Compensation for pulse imperfections in NMR spin-echo experiments
Levitt, M. H., & Freeman, R. (1981) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(81)90082-2 · Cited by 287 · cited 1×
“Since a single HS 180° pulse with a slice-selection gradient produces a large first-order phase variation across the spectrum, two consecutive HS pulses are needed to cancel it out (63, 64).”
AUTO-SMASH: A self-calibrating technique for SMASH imaging
Jakob, P. M., Grisowld, M. A., Edelman, R. R., & Sodickson, D. K. (1998) · Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine · doi:10.1007/bf02592256 · Cited by 278
Quantitative proton MR spectroscopic imaging of the human brain
Soher, B. J., van Zijl, P. C. M., Duyn, J. H., & Barker, P. B. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350313 · Cited by 271
Self-citationCentral brightening due to constructive interference with, without, and despite dielectric resonance
Collins, C. M., Liu, W., Schreiber, W., Yang, Q. X., & Smith, M. B. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20245 · Cited by 245 · cited 1×
“For instance, uniform RF transmit (B1) fields become difficult to achieve because of wavelength effects in volume RF coils (58) or when using inhomogeneous surface coils for excitation.”
[Clinical applications of magnetic resonance spectroscopy].
Terrier, F., Vock, P., HERSCHKOWITZ, N. N., Lazeyras, F., & Aue, W. P. (1988) · PubMed · Cited by 239
Bhakoo, K. K., & Pearce, D. (2000) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2000.0740254.x · Cited by 236
Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopy
Moonen, C. T. W., Kienlin, M. V., Van Zijl, P. C. M., Cohen, J., Gillen, J., Daly, P., & Wolf, G. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020506 · Cited by 216 · cited 1×
“STEAM and PRESS have been compared in detail (56); perhaps the Zhu and Barker Page 3”
Star-Lack, J. M., Nelson, S. J., Kurhanewicz, J. V., Huang, L., & Vigneron, D. B. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380222 · Cited by 215 · cited 1×
“, the “MEGA” or “BASING” sequences) (99, 100).”
Clinical applications of magnetic resonance spectroscopy.
Ross, B. D., & Michaelis, T. (1994) · PubMed · Cited by 214
Volumetric spectroscopic imaging with spiral‐based k‐space trajectories
Adalsteinsson, E., Irarrazabal, P., Topp, S., Meyer, C., Macovski, A., & Spielman, D. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390606 · Cited by 202 · cited 1×
“The k,t-space can be filled using multiple shots to satisfy the desired FOV and spatial and spectral resolutions (79).”
Penrice, J., Cady, E. B., Lorek, A., Wylezinska, M., Amess, P. N., Aldridge, R. F., Stewart, A., Wyatt, J. S., & Reynolds, E. O. R. (1996) · Pediatric Research · doi:10.1203/00006450-199607000-00002 · Cited by 201
Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain.
Posse, S., DeCarli, C., & Le Bihan, D. (1994) · Radiology · doi:10.1148/radiology.192.3.8058941 · Cited by 190 · cited 1×
“EPSI-encoding can be implemented as 2D multi-slice with spin-echo excitation, or 3D with a PRESS or spin-echo thick slab excitation (74, 75).”
Self‐calibrating parallel imaging with automatic coil sensitivity extraction
McKenzie, C. A., Yeh, E. N., Ohliger, M. A., Price, M. D., & Sodickson, D. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10087 · Cited by 189
Quantitative proton spectroscopy of canine brain: in Vivo and in Vitro correlations
Barker, P. B., Breiter, S. N., Soher, B. J., Chatham, J. C., Forder, J. R., Samphilipo, M. A., Magee, C. A., & Anderson, J. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320202 · Cited by 187 · cited 1×
“20 ppm) is a composite peak consisting of contributions from the trimethylamine groups of glycerophosphocholine (GPC), phosphocholine (PC), and a small amount of free choline itself (16).”
Self-citationThe proton NMR spectrum in acute EAE: The significance of the change in the Cho:Cr ratio
Brenner, R. E., Munro, P. M. G., Williams, S. C. R., Bell, J. D., Barker, G. J., Hawkins, C. P., Landon, D. N., & McDonald, W. I. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290605 · Cited by 185 · cited 1×
“Other pathological processes which lead to Cho elevation include active demyelination (19), either resulting from the degradation of myelin phospholipids primarily to GPC or perhaps due to inflammation (20).”
Spectroscopic imaging of stroke in humans: Histopathology correlates of spectral changes
Petroff, O. A. C., Graham, G. D., Blamire, A. M., Al-Rayess, M., Rothman, D. L., Fayad, P. B., Brass, L. M., Shulman, R. G., & Prichard, J. W. (1992) · Neurology · doi:10.1212/wnl.42.7.1349 · Cited by 181 · cited 1×
“However, lactate is often detected by MRS in pathological conditions such as acute hypoxic (25) or ischemic (5, 26) injury, or in brain tumors (27) or mitochondrial diseases (7, 28).”
Hyperpolarization of 13C through order transfer from parahydrogen: A new contrast agent for MRI
Goldman, M., Jóhannesson, H., Axelsson, O., & Karlsson, M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.11.031 · Cited by 177 · cited 1×
“While interest remains, particularly at high magnetic field strengths, in nuclei such as 31P, 23Na, and 13C (particularly for isotopically labeled and/or hyper-polarized molecules (4)), the vast majority of brain MRS studies in vivo use the proton.”
Terpstra, M., Henry, P., & Gruetter, R. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10499 · Cited by 175 · cited 3×
“TR 2 s, voxel size 3.5×3.5×3.5 = ~43 cm3, centered on the anterior cingulate gyrus, with TE 68 ms for GABA and 130 ms for GSH. Scan time was 8 min 32 s for GABA and 17 min 4 s for GSH. Note that in (a) glutamate/glutamine (Glx) coedit with GABA, and in (b) the aspartyl resonances of NAA coedit with GSH. Methods Mol Bi…”
InfluentialAcute stroke: evaluation with serial proton MR spectroscopic imaging.
Barker, P. B., Gillard, J. H., van Zijl, P. C., Soher, B. J., Hanley, D. F., Agildere, A. M., Oppenheimer, S. M., & Bryan, R. N. (1994) · Radiology · doi:10.1148/radiology.192.3.8058940 · Cited by 174 · cited 1×
“However, lactate is often detected by MRS in pathological conditions such as acute hypoxic (25) or ischemic (5, 26) injury, or in brain tumors (27) or mitochondrial diseases (7, 28).”
Self-citationIn vivo proton MR spectroscopy of the human brain
Barker, P. B., & Lin, D. D. M. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.06.002 · Cited by 171 · cited 1×
“With the development of improved techniques for spatial localization and water suppression, proton MRS became more prevalent in the 1990s because of its higher sensitivity and greater convenience (since it can be performed without hardware modification on most MRI machines, unlike MRS of other nuclei) (3).”
Self-citationProton MR spectroscopy in the diagnostic evaluation of suspected mitochondrial disease.
Lin, D. D. M., Crawford, T. O., & Barker, P. B. (2003) · PubMed · Cited by 166
Self-citationTowards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses
Scheenen, T. W. J., Heerschap, A., & Klomp, D. W. J. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-007-0094-y · Cited by 166 · cited 1×
“2d) or its simplified version “semi-LASER” (61, 62) (Fig.”
N‐Acetyl Aspartate—A Neuronal Marker?
Barker, P. B. (2001) · Annals of Neurology · doi:10.1002/ana.90 · Cited by 149 · cited 1×
“It has been speculated to be a source of acetyl groups for lipid synthesis, a regulator of protein synthesis, a storage form of acetyl-CoA or aspartate, a breakdown product of NAAG (which, unlike NAA, is a neurotransmitter), or an osmolyte (11).”
Self-citationVolumetric proton spectroscopic imaging of mild traumatic brain injury.
Govindaraju, V., Gauger, G. E., Manley, G. T., Ebel, A., Meeker, M., & Maudsley, A. A. (2004) · PubMed · Cited by 149
Matthews, P. M., Andermann, F., Silver, K., et al. (1993) · Neurology · doi:10.1212/wnl.43.12.2484 · Cited by 147 · cited 1×
“However, lactate is often detected by MRS in pathological conditions such as acute hypoxic (25) or ischemic (5, 26) injury, or in brain tumors (27) or mitochondrial diseases (7, 28).”
Brain metabolites as 1 H NMR markers of neuronal and glial disorders
Gill, S. S., Small, R. K., Thomas, D. G. T., Patel, P., Porteous, R., van Bruggen, N., Gadian, D. G., Kauppinen, R. A., & Williams, S. R. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020505 · Cited by 143 · cited 13×
“Low brain Cho has been observed in hepatic encephalopathy (21), and there is also some evidence to suggest that dietary intake of choline can modulate cerebral Cho levels (22).”
InfluentialBottomley, P. A., Edelstein, W. A., Foster, T. H., & Adams, W. A. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.7.2148 · Cited by 133 · cited 1×
“In vivo magnetic resonance spectroscopy (MRS) of the human brain has developed rapidly since its first observation in the 1980s (1, 2).”
Spiral imaging: A critical appraisal
Block, K. T., & Frahm, J. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20320 · Cited by 131 · cited 1×
“Post-processing of spiral-MRSI data usually starts with a “regridding” procedure (80) where raw data are resampled onto a Cartesian k-space grid by interpolation, after which conventional MRSI processing by Fourier transformation can be done.”
Kruse, B., Hanefeld, F. A., Christen, H.-J., Bruhn, H., Michaelis, T., H�nicke, W., & Frahm, J. (1993) · Journal of Neurology · doi:10.1007/bf00869766 · Cited by 120 · cited 1×
“mI has been reported to be reduced in hepatic encephalopathy (31), and increased in Alzheimer’s dementia (32) and demyelinating diseases (33).”
Homocarnosine and the measurement of neuronal pH in patients with epilepsy
Rothman, D. L., Behar, K. L., Prichard, J. W., & Petroff, O. A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380611 · Cited by 115 · cited 1×
“were able to use the imidazole resonances of homocarnosine to estimate brain pH in epilepsy patients who were receiving vigabatrin (49).”
Proton NMR spectroscopy of solvent‐saturable resonances: A new approach to study pH effects in Situ
Mori, S., Eleff, S. M., Pilatus, U., Mori, N., & van Zijl, P. C. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400105 · Cited by 110 · cited 1×
“The rate of exchange of the NAA amide protons with water is also pH sensitive and can be used to estimate brain pH (50).”
1H mrs of human brain abscesses in vivo and in vitro
Rémy, C., Grand, S., Lai, E. S., Belle, V., Hoffmann, D., Berger, F. R., Estève, F., Ziegler, A., Bas, J. F. L., Benabid, A. L., et al. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340404 · Cited by 105
de Beer, R., van den Boogaart, A., van Ormondt, D., Pijnappel, W. W. F., den Hollander, J. A., Marien, A. J. H., & Luyten, P. R. (1992) · NMR in Biomedicine · doi:10.1002/nbm.1940050403 · Cited by 102 · cited 1×
“Various methods have been used to measure peak areas, ranging from simple integration, to fitting algorithms in the time- or frequency domains (105, 106).”
On the N‐acetyl methyl resonance in localized 1H NMR spectra of human brain In Vivo
Frahm, J., Michaelis, T., Merboldt, K., Hänicke, W., Gyngell, M. L., & Bruhn, H. (1991) · NMR in Biomedicine · doi:10.1002/nbm.1940040408 · Cited by 101
Sensitivity‐encoded (SENSE) proton echo‐planar spectroscopic imaging (PEPSI) in the human brain
Lin, F., Tsai, S., Otazo, R., Caprihan, A., Wald, L. L., Belliveau, J. W., & Posse, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21119 · Cited by 100 · cited 15×
“Spiral-MRSI has some unique advantages over EPSI, including the ability to manipulate the point-spread function, scan time, and SNR by varying the sample spacing in k-space with a variable density trajectory (81, 82).”
InfluentialDetection of myelin breakdown products by proton magnetic resonance spectroscopy
Davie, C. A., Barker, G. J., Tofts, P. S., Hawkins, C. P., Brennan, A., Miller, D. H., & McDonald, W. I. (1993) · The Lancet · doi:10.1016/0140-6736(93)90390-3 · Cited by 94 · cited 1×
“Other pathological processes which lead to Cho elevation include active demyelination (19), either resulting from the degradation of myelin phospholipids primarily to GPC or perhaps due to inflammation (20).”
Identification of cerebral acetone by H-MRS in patients with epilepsy controlled by ketogenic diet
Seymour, K. J., Blüml, S., Sutherling, J. E. N., Sutherling, W. W., & Ross, B. D. (1999) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02590633 · Cited by 92 · cited 1×
“Examples include the ketone bodies β-hydroxy-butyrate and acetone (41, 42) in patients who are ketotic and other compounds such as phenylalanine (in phenylketonurea (43)), galactitol, ribitol, arabitol in “polyol disease” (44), and succinate, pyruvate, alanine, glycine, and threonine in various disorders.”
In vivo quantitation of metabolite concentrations in the brain by means of proton MRS
Henriksen, O. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080402 · Cited by 85 · cited 1×
“Quantification methods based on internal or external standards have been extensively developed and tested for single-voxel spectroscopy (108).”
Elfar Adalsteinsson, A., Langer-Gould, A. M., Homer, R. J., Rao, A., Sullivan, E. V., Lima, C. A., Adolf Pfefferbaum, A., & Atlas, S. W. (2003) · PubMed · Cited by 83
Leukoencephalopathy associated with a disturbance in the metabolism of polyols
van der Knaap, M. S., Wevers, R. A., Struys, E. A., Verhoeven‐Duif, N. M., Pouwels, P. J. W., Engelke, U. F. H., Wj, F., Valk, J., & Jakobs, C. (1999) · Annals of Neurology · doi:10.1002/1531-8249(199912)46:6<925::aid-ana18>3.0.co;2-j · Cited by 83 · cited 1×
“Examples include the ketone bodies β-hydroxy-butyrate and acetone (41, 42) in patients who are ketotic and other compounds such as phenylalanine (in phenylketonurea (43)), galactitol, ribitol, arabitol in “polyol disease” (44), and succinate, pyruvate, alanine, glycine, and threonine in various disorders.”
Measurement of β‐hydroxybutyrate in acute hyperketonemia in human brain
Pan, J. W., Telang, F., Lee, J. H., de Graaf, R. A., Rothman, D. L., Stein, D. T., & Hetherington, H. P. (2001) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2001.00575.x · Cited by 79
Magnetic Resonance Spectroscopy and Spectroscopic Imaging for the Study of Brain Metabolisma
van Zijl, P. C. M., & Barker, P. B. (1997) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1997.tb46190.x · Cited by 78 · cited 1×
“Some examples of these compounds include NAAG, aspartate, taurine, scyllo-inositol, betaine, ethanolamine, purine nucleotides, histidine, glucose, and glycogen (38).”
Self-citationvan Zijl, P. C. M., MOONEN, C. T. W., Alger, J. R., Cohen, J. S., & Chesnick, S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100210 · Cited by 77 · cited 1×
“Signals from outside the voxel are removed by the use of “crusher” field gradient pulses, alternating the phases of the slice-selective pulses and receiver (‘phase-cycling’), and the use of outervolume suppression pulses (51, 52) (53, 54).”
Quantitative proton MR spectroscopic imaging of normal human cerebellum and brain stem
Jacobs, M. A., Horská, A., van Zijl, P. C. M., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1248 · Cited by 75 · cited 2×
“In particular, Cr shows quite marked regional variations (24), and often changes in pathology, so caution should be used when interpreting ratios of metabolites to Cr.”
Vermathen, P., Capizzano, A. A., & Maudsley, A. A. (2000) · Magnetic Resonance in Medicine · Cited by 75
Kreis, R., Pietz, J., Penzien, J. M., HERSCHKOWITZ, N. N., & Boesch, C. (1995) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1995.1084 · Cited by 70 · cited 1×
“Examples include the ketone bodies β-hydroxy-butyrate and acetone (41, 42) in patients who are ketotic and other compounds such as phenylalanine (in phenylketonurea (43)), galactitol, ribitol, arabitol in “polyol disease” (44), and succinate, pyruvate, alanine, glycine, and threonine in various disorders.”
Dreher, W., & Leibfritz, D. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00156-8 · Cited by 70 · cited 1×
“However, they do offer some unique advantages, such as using a constant evolution time with a sliding refocusing pulse, to produce “homonuclear decoupled” proton brain spectra (95).”
Tsai, S., Otazo, R., Posse, S., Lin, Y., Chung, H., Wald, L. L., Wiggins, G. C., & Lin, F. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21545 · Cited by 69 · cited 4×
“Alternatively, algorithms such as “SMASH” and “GRAPPA” (87– 89) can be implemented to interpolate the missing k-space data points, which are then Fourier transformed as in conventional MRSI.”
InfluentialStoll, A. L., Renshaw, P. F., Micheli, E. D., Wurtman, R. J., Pillay, S. S., & Cohen, B. M. (1995) · Biological Psychiatry · doi:10.1016/0006-3223(94)00120-r · Cited by 64 · cited 1×
“Low brain Cho has been observed in hepatic encephalopathy (21), and there is also some evidence to suggest that dietary intake of choline can modulate cerebral Cho levels (22).”
Slotboom, J., Mehlkopf, A. F., & Bovée, W. M. M. J. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90229-m · Cited by 60
Scan time reduction in proton magnetic resonance spectroscopic imaging of the human brain
Golay, X., GILLEN, J. S., van Zijl, P. C. M., & Barker, P. B. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10038 · Cited by 42 · cited 1×
“In the case of brain imaging, the left–right FOV should be smaller than the anterior–posterior, since the brain (usually of an oval shape) is smaller in this dimension (68).”
Self-citationMeasurement of ethanol in the human brain using NMR spectroscopy.
Hanstock, C. C., Rothman, D. L., Shulman, R. G., Novotny, E. J., Petroff, O. A. C., & Prichard, J. W. (1990) · Journal of Studies on Alcohol · doi:10.15288/jsa.1990.51.104 · Cited by 40 · cited 1×
“Exogenous compounds which are able to cross the blood–brain barrier may be detected by proton MRS; examples include the drug delivery vehicle propan-1,2-diol (45), ethanol (46), and methylsulfonylmethane (MSM) (47).”
Spiral readout gradients for the reduction of motion artifacts in chemical shift imaging
Kim, D., Adalsteinsson, E., & Spielman, D. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20004 · Cited by 32 · cited 1×
“In addition, if the center of k-space is collected at the beginning of every spiral readout, it is possible to correct errors in phase or frequency associated with motion or other processes (83).”
3-D echo planar 1HMRS imaging in MS: metabolite comparison from supratentorial vs. central brain
Pelletier, D., Nelson, S. J., Grenier, D., Lü, Y., Genain, C. P., & Goodkin, D. E. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00533-7 · Cited by 24 · cited 1×
“Because of its speed and much improved post-processing methods, EPSI (also called “PEPSI” (proton EPSI)) has been gaining popularity in whole-brain 3D MRSI (75) and has also been used to study various brain pathologies (77, 78).”
Gu, M., & Spielman, D. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21843 · Cited by 18 · cited 1×
“Recently, methods have been designed which combine both water and lipid suppression into a single, dual band approach (94, 102, 103).”
Yongbi, M. N., Huang, N. C., Branch, C. A., & Helpern, J. A. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199704)10:2<73::aid-nbm448>3.0.co;2-4 · Cited by 13
Cited by
Keshari, K. R., & Wilson, D. M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60124b · Cited by 358
Lin, A., Andronesi, O., Bogner, W., Choi, I., Coello, E., Cudalbu, C., Juchem, C., Kemp, G. J., Kreis, R., Krššák, M., et al. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4484 · Cited by 334
Technological advancements in cancer diagnostics: Improvements and limitations
Pulumati, A., Pulumati, A., Dwarakanath, B. S., Verma, A., & Papineni, R. V. L. (2023) · Cancer Reports · doi:10.1002/cnr2.1764 · Cited by 326
Edited magnetic resonance spectroscopy detects an age-related decline in brain GABA levels
Gao, F., Edden, R. A. E., Li, M., Puts, N. A. J., Wang, G., Liu, C., Zhao, B., Wang, H., Bai, X., Zhao, C., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.012 · Cited by 285
Self-citationBirur, B., Kraguljac, N. V., Shelton, R. C., & Lahti, A. C. (2017) · npj Schizophrenia · doi:10.1038/s41537-017-0013-9 · Cited by 203
“23 Magnetic resonance spectroscopy (MRS) measures chemical composition of tissues, energy metabolism, and neurotransmitter levels in vivo.(24) The most common type of spectroscopy leverages the signal produced by protons located in the molecules of living tissue to quantify different metabolites ((1)H-MRS).”
Background
Metadata
- Authors
- Zhu, H., & Barker, P. B.
- Venue
- Methods in Molecular Biology
- Publisher
- Humana Press
- Published
- 2010-12-15
- Volume
- 711
- Pages
- 203-226
- ISSN
- 1064-3745 (ISSN-L)
- 1940-6029
- OpenAlex
- W41104782
- Cited by
- 208
- References
- 85
- FWCI
- 20.69
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.