CoChat

Tactile feedback is an effective instrument for the training of grasping with a prosthesis at low- and medium-force levels

Open access
De Nunzio, Alessandro Marco, Dosen, Strahinja, Lemling, Sabrina, Markovic, Marko, Schweisfurth, Meike Annika, Ge, Nan, Graimann, Bernhard, Falla, Deborah, Farina, Dario · 2017 · Experimental Brain Research
Cited by 62

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Grasping is a complex task routinely performed in an anticipatory (feedforward) manner, where sensory feedback is responsible for learning and updating the internal model of grasp dynamics. This study aims at evaluating whether providing a proportional tactile force feedback during the myoelectric control of a prosthesis facilitates learning a stable internal model of the prosthesis force control. Ten able-bodied subjects controlled a sensorized myoelectric prosthesis performing four blocks of consecutive grasps at three levels of target force (30, 50, and 70%), repeatedly closing the fully opened hand. In the first and third block, the subjects received tactile and visual feedback, respectively, while during the second and fourth block, the feedback was removed. The subjects also performed an additional block with no feedback 1 day after the training (Retest). The median and interquartile range of the generated forces was computed to assess the accuracy and precision of force control. The results demonstrated that the feedback was indeed an effective instrument for the training of prosthesis control. After the training, the subjects were still able to accurately generate the desired force for the low and medium target (30 and 50% of maximum force available in a prosthesis), despite the feedback being removed within the session and during the retest (low target force). However, the training was substantially less successful for high forces (70% of prosthesis maximum force), where subjects exhibited a substantial loss of accuracy as soon as the feedback was removed. The precision of control decreased with higher forces and it was consistent across conditions, determined by an intrinsic variability of repeated myoelectric grasping. This study demonstrated that the subject could rely on the tactile feedback to adjust the motor command to the prosthesis across trials. The subjects adjusted the mean level of muscle activation (accuracy), whereas the precision could not be modulated as it depends on the intrinsic myoelectric variability. They were also able to maintain the feedforward command even after the feedback was removed, demonstrating thereby a stable learning, but the retention depended on the level of the target force. This is an important insight into the role of feedback as an instrument for learning of anticipatory prosthesis force control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00221-017-4991-7

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Research works printed but not linked: 44

  1. Antfolk C, Cipriani C, Carrozza MC et al (2013a) Transfer of tactile input from an artificial hand to the forearm: experiments in amputees and able-bodied volunteers. Disabil Rehabil Assist Technol 8:249–254. doi: 10.3109/17483107.2012.713435 · DOI · Paper page
  2. Augurelle AS, Smith AM, Lejeune T, Thonnard JL (2003) Importance of cutaneous feedback in maintaining a secure grip during manipulation of hand-held objects. J Neurophysiol 89:665–671. doi: 10.1152/jn.00249.2002 · DOI · Paper page
  3. Belter JT, Segil JL, Dollar AM, Weir RF (2013) Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review. J Rehabil Res Dev 50:599–618 · DOI · Paper page
  4. Bouwsema H, van der Sluis CK, Bongers RM (2014) Changes in performance over time while learning to use a myoelectric prosthesis. J Neuroeng Rehabil 11:16. doi: 10.1186/1743-0003-11-16 · DOI
  5. Cipriani C, Zaccone F, Micera S, Carrozza MC (2008) On the shared control of an EMG-controlled prosthetic hand: analysis of user-prosthesis interaction. IEEE Trans Rob 24:170–184. doi: 10.1109/Tro.2007.910708 · DOI · Paper page
  6. Cordella F, Ciancio AL, Sacchetti R, Davalli A, Cutti AG, Guglielmelli E, Zollo L (2016) Literature review on needs of upper limb prosthesis users. Front Neurosci 10:209. doi: 10.3389/fnins.2016.00209 · DOI · Paper page
  7. D’Alonzo M, Dosen S, Cipriani C, Farina D (2014a) HyVE-hybrid vibro-electrotactile stimulation-is an efficient approach to multi-channel sensory feedback. IEEE Trans Haptics 7:181–190. doi: 10.1109/TOH.2013.52 · DOI · Paper page
  8. D’Alonzo M, Dosen S, Cipriani C, Farina D (2014b) HyVE: hybrid vibro-electrotactile stimulation for sensory feedback and substitution in rehabilitation. IEEE Trans Neural Syst Rehabil Eng 22:290–301. doi: 10.1109/TNSRE.2013.2266482 · DOI · Paper page
  9. Dosen S, Markovic M, Hartmann C, Farina D (2014) Sensory feedback in prosthetics: a standardized test bench for closed-loop control. IEEE Trans Neural Syst Rehabil Eng. doi: 10.1109/TNSRE.2014.2371238 · DOI
  10. Dosen S, Markovic M, Wille N et al (2015) Building an internal model of a myoelectric prosthesis via closed-loop control for consistent and routine grasping. Exp Brain Res. doi: 10.1007/s00221-015-4257-1 · DOI
  11. Dosen S, Markovic M, Strbac M et al (2016) Multichannel electrotactile feedback with spatial and mixed coding for closed-loop control of grasping force in hand prostheses. IEEE Trans Neural Syst Rehabil Eng. doi: 10.1109/TNSRE.2016.2550864 · DOI · Paper page
  12. Enoka RM, Fuglevand AJ (2001) Motor unit physiology: some unresolved issues. Muscle Nerve 24:4–17. doi: 10.1002/1097-4598(200101)24:1<4:Aid-Mus13>3.0.Co;2-F · DOI · Paper page
  13. Flanagan JR, Wing AM (1997) The role of internal models in motion planning and control: evidence from grip force adjustments during movements of hand-held loads. J Neurosci 17:1519–1528 · DOI · Paper page
  14. Flanagan JR, King S, Wolpert DM, Johansson RS (2001) Sensorimotor prediction and memory in object manipulation. Can J Exp Psychol 55:87–95 · DOI
  15. Franklin DW, Wolpert DM (2011) Computational mechanisms of sensorimotor control. Neuron 72:425–442. doi: 10.1016/j.neuron.2011.10.006 · DOI · Paper page
  16. Georgopoulos AP, Grillner S (1989) Visuomotor coordination in reaching and locomotion. Science 245:1209–1210 · DOI · Paper page
  17. Green S, Grierson LE, Dubrowski A, Carnahan H (2010) Motor adaptation and manual transfer: insight into the persistent nature of sensorimotor representations. Brain Cogn 72:385–393. doi: 10.1016/j.bandc.2009.11.006 · DOI
  18. Henneman E, Somjen G, Carpenter DO (1965) Excitability and inhibitability of motoneurons of different sizes. J Neurophysiol 28:599 · DOI · Paper page
  19. Hermsdorfer J, Elias Z, Cole JD, Quaney BM, Nowak DA (2008) Preserved and impaired aspects of feed-forward grip force control after chronic somatosensory deafferentation. Neurorehabil Neural Repair 22:374–384. doi: 10.1177/1545968307311103 · DOI
  20. Hermsdorfer J, Li Y, Randerath J, Goldenberg G, Eidenmuller S (2011) Anticipatory scaling of grip forces when lifting objects of everyday life. Exp Brain Res 212:19–31. doi: 10.1007/s00221-011-2695-y · DOI
  21. Jarrasse N, Kuhne M, Roach N, Hussain A, Balasubramanian S, Burdet E, Roby-Brami A (2013) Analysis of grasping strategies and function in hemiparetic patients using an instrumented object. IEEE Int Conf Rehabil Robot 2013:6650379. doi: 10.1109/ICORR.2013.6650379 · DOI
  22. Johansson RS, Westling G (1988) Coordinated isometric muscle commands adequately and erroneously programmed for the weight during lifting task with precision grip. Exp Brain Res 71:59–71
  23. Johnson RE, Kording KP, Hargrove LJ, Sensinger JW (2014) Does EMG control lead to distinct motor adaptation? Front Neurosci. doi: 10.3389/Fnins.2014.00302 · DOI
  24. Jones LA, Safter NB (2008) Tactile displays: guidance for their design and application. Hum Factors 50:90–111. doi: 10.1518/001872008x250638 · DOI · Paper page
  25. Jones KE, Hamilton AF, Wolpert DM (2002) Sources of signal-dependent noise during isometric force production. J Neurophysiol 88:1533–1544 · DOI · Paper page
  26. Jorgovanovic N, Dosen S, Djozic DJ, Krajoski G, Farina D (2014) Virtual grasping: closed-loop force control using electrotactile feedback. Comput Math Methods Med 2014:120357. doi: 10.1155/2014/120357 · DOI · Paper page
  27. Laine CM, Yavuz SU, Farina D (2014) Task-related changes in sensorimotor integration influence the common synaptic input to motor neurones. Acta Physiol (Oxf) 211:229–239. doi: 10.1111/apha.12255 · DOI
  28. Lum PS, Black I, Holley RJ, Barth J, Dromerick AW (2014) Internal models of upper limb prosthesis users when grasping and lifting a fragile object with their prosthetic limb. Exp Brain Res. doi: 10.1007/s00221-014-4071-1 · DOI
  29. Macefield VG, Johansson RS (1996) Control of grip force during restraint of an object held between finger and thumb: responses of muscle and joint afferents from the digits. Exp Brain Res 108:172–184
  30. Macefield VG, Hager-Ross C, Johansson RS (1996) Control of grip force during restraint of an object held between finger and thumb: responses of cutaneous afferents from the digits. Exp Brain Res 108:155–171
  31. Marteniuk RG, Bertram CP (2001) Contributions of gait and trunk movements to prehension: perspectives from world- and body-centered coordinates. Mot Control 5:151–165 · doi:10.1123/mcj.5.2.151
  32. Metzger AJ, Dromerick AW, Schabowsky CN, Holley RJ, Monroe B, Lum PS (2010) Feedforward control strategies of subjects with transradial amputation in planar reaching. J Rehabil Res Dev 47:201–211. doi: 10.1682/Jrrd.2009.06.0075 · DOI
  33. Ninu A, Dosen S, Muceli S, Rattay F, Dietl H, Farina D (2014) Closed-loop control of grasping with a myoelectric hand prosthesis: which are the relevant feedback variables for force control? IEEE Trans Neural Syst Rehabil Eng 22:1041–1052. doi: 10.1109/TNSRE.2014.2318431 · DOI · Paper page
  34. Nowak DA, Glasauer S, Meyer L, Mait N, Hermsdorfer J (2002) The role of cutaneous feedback for anticipatory grip force adjustments during object movements and externally imposed variation of the direction of gravity. Somatosens Mot Res 19:49–60 · DOI
  35. Nowak DA, Glasauer S, Hermsdorfer J (2004) How predictive is grip force control in the complete absence of somatosensory feedback? Brain 127:182–192. doi: 10.1093/Brain/Awh016 · DOI
  36. Nowak DA, Glasauer S, Hermsdorfer J (2013) Force control in object manipulation–a model for the study of sensorimotor control strategies. Neurosci Biobehav Rev 37:1578–1586. doi: 10.1016/j.neubiorev.2013.06.003 · DOI
  37. Peerdeman B, Boere D, Witteveen H et al (2011) Myoelectric forearm prostheses: state of the art from a user-centered perspective. J Rehabil Res Dev 48:719–737 · DOI · Paper page
  38. Saunders I, Vijayakumar S (2011) The role of feed-forward and feedback processes for closed-loop prosthesis control. J Neuroeng Rehabil 8:60. doi: 10.1186/1743-0003-8-60 · DOI · Paper page
  39. Schofield JS, Evans KR, Carey JP, Hebert JS (2014) Applications of sensory feedback in motorized upper extremity prosthesis: a review. Expert Rev Med Devices 11:499–511. doi: 10.1586/17434440.2014.929496 · DOI · Paper page
  40. Smurr LM, Gulick K, Yancosek K, Ganz O (2008) Managing the upper extremity amputee: a protocol for success. J Hand Ther 21:160–175. doi: 10.1197/j.jht.2007.09.006 (quiz 176) · DOI · Paper page
  41. van der Wel RP, Rosenbaum DA (2007) Coordination of locomotion and prehension. Exp Brain Res 176:281–287. doi: 10.1007/s00221-006-0618-0 · doi:10.1007/s00221-006-0618-0
  42. Weeks DL, Wallace SA, Noteboom JT (2000) Precision-grip force changes in the anatomical and prosthetic limb during predictable load increases. Exp Brain Res 132:404–410 · DOI
  43. Wei K, Kording K (2010) Uncertainty of feedback and state estimation determines the speed of motor adaptation. Front Comput Neurosci 4:11. doi: 10.3389/fncom.2010.00011 · DOI · Paper page
  44. Wolpert DM, Ghahramani Z, Flanagan JR (2001) Perspectives and problems in motor learning. Trends Cogn Sci 5:487–494 · DOI · Paper page

Cited by

See all 62

Metadata

Authors
De Nunzio, A. M., Dosen, S., Lemling, S., Markovic, M., Schweisfurth, M. A., Ge, N., Graimann, B., Falla, D., & Farina, D.
Venue
Experimental Brain Research
Published
2017-05-26
Volume
235
Issue
8
Pages
2547-2559
ISSN
  • 0014-4819 (ISSN-L)
  • 1432-1106
OpenAlex
W2620469418
Cited by
62
References
10
FWCI
2.68
Type
journal article
Language
en
Open access
hybrid
Funders
Seventh Framework Programme (FP7-PEOPLE-2011-IAPP-286208)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tactile feedback is an effective instrument for the training of grasping with a prosthesis at low- and medium-force levels. https://app.cochat.ai/papers/10.1007/s00221-017-4991-7
The paper
De Nunzio, A. M., Dosen, S., Lemling, S., Markovic, M., Schweisfurth, M. A., Ge, N., Graimann, B., Falla, D., & Farina, D. (2017). Tactile feedback is an effective instrument for the training of grasping with a prosthesis at low- and medium-force levels. Experimental Brain Research. https://doi.org/10.1007/s00221-017-4991-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.