The cone electrode: Ultrastructural studies following long-term recording in rat and monkey cortex
The DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index.
Abstract
The achievement of long-term recording of neural signals from the central nervous system has potential clinical and investigative application. To facilitate long-term recording, a novel cone electrode composed of an insulated gold wire within a hollow glass cone had been developed. Cone electrodes containing sciatic nerve or neurotrophic medium were implanted into cerebral cortex in rats and monkeys. Electrophysiologic recordings had been previously obtained from cone tissue for as long as 15 months following implantation and this tissue contained silver-positive processes. We now extend these observations to characterize the fine structural features of the tissue within these long-term implants. Electron microscopy revealed central myelinated axons, dendrites, synaptic profiles, blood vessels, and glia; peripheral nerve was not found in the cones in which sciatic nerve had been placed. These observations further suggest ingrowth of cortical neurites and elements into the hollow glass tip of the cone and support the feasibility of long-term recording using this electrode.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“signals were successfully recorded in rats and nonhuman primates, 83,84”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [83]
Citations
Cites
David, S., & Aguayo, A. J. (1981) · Science · doi:10.1126/science.6171034 · Cited by 1,683
Extensive elongation of axons from rat brain into peripheral nerve grafts
Benfey, M., & Aguayo, A. J. (1982) · Nature · doi:10.1038/296150a0 · Cited by 442
So, K.-F., & Aguayo, A. J. (1985) · Brain Research · doi:10.1016/0006-8993(85)91047-9 · Cited by 390
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Long-term implants of Parylene-C coated microelectrodes
Schmidt, E. M., Mcintosh, J. S., & Bak, M. J. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441836 · Cited by 234
Electrophysiologic Responses in Hamster Superior Colliculus Evoked by Regenerating Retinal Axons
Keirstead, S. A., Rasminsky, M., Fukuda, Y., Carter, D. A., Aguayo, A. J., & Vidal-Sanz, M. (1989) · Science · doi:10.1126/science.2799387 · Cited by 213
Gasser, U., & Hatten, M. (1990) · The Journal of Neuroscience · doi:10.1523/jneurosci.10-04-01276.1990 · Cited by 160
Kennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151
Self-citationDavid, S., & Aguayo, A. J. (1985) · Journal of Neurocytology · doi:10.1007/bf01150259 · Cited by 144
Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording
BeMent, S. L., Wise, K. D., Anderson, D. J., Najafi, K., & Drake, K. L. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325895 · Cited by 142
Research works printed but not linked: 2
- DiStefano, 1986, Induction of nerve growth factor (NGF) receptors on cultured rat Schwann cells, Soc. Neurosci. Abstr., 12, 392
- Kennedy, 1990, Long-term recording of cortical units using the Cone Electrode in monkeys, Soc. Neurosci. Abstr., 16, 1134
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Direct control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
Self-citationWadhwa, R., Lagenaur, C. F., & Cui, X. T. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.10.027 · Cited by 496
Restoration of neural output from a paralyzed patient by a direct brain connection
Kennedy, P. R., & Bakay, R. A. E. (1998) · NeuroReport · doi:10.1097/00001756-199806010-00007 · Cited by 475
Self-citationA Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
A Wireless Brain-Machine Interface for Real-Time Speech Synthesis
Guenther, F. H., Brumberg, J. S., Wright, E. J., Nieto-Castanon, A., Tourville, J. A., Panko, M., Law, R., Siebert, S. A., Bartels, J. L., Andreasen, D. S., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008218 · Cited by 306
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
“In a later paper (77), the application was confirmed for monkey and for neurotrophic medium fill, with histologic examination suggesting again that ingrowth of cortical neurites”
BackgroundBrain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
Self-citationSchultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
“Both cone electrodes and icroelectrode arrays have been shown to record reliable ignals for a little over a year in monkeys; however, no icroelectrode arrays have been verified to reliably record ction potentials for more extended periods of time [67-69].”
BackgroundImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
“A derivative of this technology is the cone electrode design which consisted of a gold metal wire fixed inside a hollow glass cone [80, 81].”
Method3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Yu, L., Gutierrez, C. A., Hoang, T. Q., Pikov, V, & Meng, E. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 155
Neural Substrate Expansion for the Restoration of Brain Function
Chen, H.-C. I., Jgamadze, D., Serruya, M. D., Cullen, D. K., Wolf, J. A., & Smith, D. H. (2016) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2016.00001 · Cited by 128
Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration
Kuo, J. T. W., Kim, B. J., Hara, S. A., Lee, C. D., Gutierrez, C. A., Hoang, T. Q., & Meng, E. (2013) · Lab Chip · doi:10.1039/c2lc40935f · Cited by 127
The sinusoidal probe: a new approach to improve electrode longevity
Sohal, H. S., Jackson, A., Jackson, R., Clowry, G. J., Vassilevski, K., O’Neill, A., & Baker, S. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00010 · Cited by 106
Brumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114
“Surgical implantation techniques follow those previously reported (Kennedy et al., 1992a).”
Neurotrophic electrode: Method of assembly and implantation into human motor speech cortex
Bartels, J., Andreasen, D., Ehirim, P., Mao, H., Seibert, S., Wright, E. J., & Kennedy, P. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.030 · Cited by 108
“Neither microglial cells nor gliotic tissues have ever been seen in the many rat and monkey histological examinations (Kennedy et al, 1992a).”
BackgroundSelf-citationEEG-based control of a hand grasp neuroprosthesis
Lauer, R. T., Peckham, P. H., & Kilgore, K. L. (1999) · NeuroReport · doi:10.1097/00001756-199906030-00026 · Cited by 106
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
Brain–Machine and Brain–Computer Interfaces
Friehs, G. M., Zerris, V. A., Ojakangas, C. L., Fellows, M. R., & Donoghue, J. P. (2004) · Stroke · doi:10.1161/01.str.0000143235.93497.03 · Cited by 86
Intracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T., Bellamkonda, R., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 93
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 92
In vivo evaluation of a neural stem cell-seeded prosthesis
Purcell, E. K., Seymour, J. P., Yandamuri, S., & Kipke, D. R. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026005 · Cited by 76
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67
Hara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066020 · Cited by 57
Khilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 56
Making the lifetime connection between brain and machine for restoring and enhancing function
Kennedy, P., Andreasen, D., Bartels, J., Ehirim, P., Mao, H., Velliste, M., Wichmann, T., & Wright, J. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00020-0 · Cited by 54
Self-citationBioactive Neuroelectronic Interfaces
Adewole, D. O., Serruya, M. D., Wolf, J. A., & Cullen, D. K. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00269 · Cited by 53
Material considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47
Physiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 46
Biohybrid neural interfaces: improving the biological integration of neural implants
Boulingre, M., Lara, R. P., & Green, R. A. (2023) · Chemical Communications · doi:10.1039/d3cc05006h · Cited by 44
Multiple single-unit recordings from the CNS using thin-film electrode arrays
Carter, R. R., & Houk, J. C. (1993) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.279266 · Cited by 34
Spatially controlling neuronal adhesion on CVD diamond
May, P. W., Regan, E. M., Taylor, A. C., Uney, J. B., Dick, A. D., & McGeehan, J. P. (2012) · Diamond and Related Materials · doi:10.1016/j.diamond.2012.01.023 · Cited by 38
Potter–Baker, K. A., & Capadona, J. R. (2015) · ACS Macro Letters · doi:10.1021/mz500743a · Cited by 39
Matrigel coatings forParylene sheath neural probes
Lee, C. D., Hara, S. A., Yu, L., Kuo, J. T. W., Kim, B. J., Hoang, T., Pikov, V., & Meng, E. (2016) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33390 · Cited by 35
Activity of single action potentials in monkey motor cortex during long-term task learning
Kennedy, P. R., & Bakay, R. A. E. (1997) · Brain Research · doi:10.1016/s0006-8993(97)00051-6 · Cited by 34
Self-citationHe, W. J., & Bellamkonda, R. V. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.pt4 · Cited by 34
Current Challenges to the Clinical Translation of Brain Machine Interface Technology
Lu, C. W., Patil, P. G., & Chestek, C. A. (2012) · International review of neurobiology · doi:10.1016/b978-0-12-404706-8.00008-5 · Cited by 26
Development of speech prostheses: current status and recent advances
Brumberg, J. S., & Guenther, F. H. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.34 · Cited by 26
Artificial speech synthesizer control by brain-computer interface
Brumberg, J. S., Kennedy, P. R., & Guenther, F. H. (2009) · Interspeech (USB) · doi:10.21437/interspeech.2009-225 · Cited by 22
Self-citationGearing, M., & Kennedy, P. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00111 · Cited by 21
Self-citationKennedy, P. (2011) · Neurocase · doi:10.1080/13554794.2010.532137 · Cited by 20
Self-citationSchouenborg, J. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00017-0 · Cited by 19
Human factors issues in the neural signals direct brain-computer interfaces
Moore, M. M., & Kennedy, P. R. (2000) · International ACM SIGACCESS Conference on Computers and Accessibility (ASSETS) · doi:10.1145/354324.354351 · Cited by 19
Self-citationWireless interfaces for brain neurotechnologies
Kim, H., & Ho, J. S. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0020 · Cited by 18
Brain-Computer Interface Control of an Anthropomorphic Robotic Arm
Clanton, S. T. (2011) · KiltHub Repository · doi:10.1184/r1/6715016 · Cited by 15
Spatially Controlling Neuronal Adhesion and Inflammatory Reactions on Implantable Diamond
Regan, E. M., Taylor, A. C., Uney, J. B., Dick, A. D., May, P. W., & McGeehan, J. P. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174469 · Cited by 14
Kennedy, P., & King, B. (2000) · Frontiers in neuroscience · doi:10.1201/9781420039054.ch7 · Cited by 13
Self-citationDesign of electrodes for stimulation and recording
Howell, B. L., & Grill, W. M. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-101-6.00004-5 · Cited by 12
Brain–Computer Interfaces: Neurophysiological Bases and Clinical Applications
Frolov, A., & Бобров, П. Д. (2018) · Neuroscience and Behavioral Physiology · doi:10.1007/s11055-018-0666-5 · Cited by 11
Augmentation of Sensorimotor Functions with Neural Prostheses
Lebedev, M. (2016) · Russian Agency for Digital Standardization · doi:10.20388/omp2016.003.0035 · Cited by 9
La spatialité originaire du corps propre: Phénoménologie et neurosciences
Petit, J.-L. (2003) · Revue de Synthèse · doi:10.1007/bf02963403 · Cited by 9
The voltammetric response of a conical electrode
Sokirko, A. V., & Oldham, K. B. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(96)04909-1 · Cited by 8
Building Brain–Machine Interfaces to Restore Neurological Functions
Nicolelis, M. A. L. (2007) · CRC Press eBooks · doi:10.1201/9781420006414-16 · Cited by 7
BRAIN-COMPUTER INTERFACE FOR THE AUGMENTATION OF BRAIN FUNCTIONS
Lebedev, M. (2016) · Science and Innovations in Medicine · doi:10.35693/2500-1388-2016-0-3-11-27 · Cited by 7
Slow Firing Single Units Are Essential for Optimal Decoding of Silent Speech
Kennedy, P., Ganesh, A., & Cervantes, A. J. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.874199 · Cited by 7
Self-citationBuilding Brain–Machine Interfaces to Restore Neurological Functions
Crist, R. E., Lebedev, M., & Nicolelis, M. A. L. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch11 · Cited by 7
Burmeister, O., Litza, M., Nitschke, M. F., & Hofmann, U. (2005) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2005.1419669 · Cited by 7
Limits of brain–computer interface
Bakay, R. A. E. (2006) · Neurosurgical FOCUS · doi:10.3171/foc.2006.20.5.7 · Cited by 7
Self-citationElectrode–Neural Tissue Interactions: Immune Responses, Current Technologies, and Future Directions
Kim, G. B., Fattahi, P., & Abidian, M. R. (2013) · Wiley eBooks · doi:10.1002/9783527649600.ch19 · Cited by 6
FABRICATION OF 3D PARYLENE SHEATH PROBES FOR RELIABLE NEUROPROSTHETIC RECORDINGS
Kuo, J. T. W., Kim, B. J., Hara, S. A., Lee, C., Gutierrez, C. A., Hoang, T., & Meng, E. F. (2012) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2012.9 · Cited by 6
Soraghan, C. J. (2010) · Maynooth University ePrints and eTheses Archive (Maynooth University) · Cited by 6
The Future of Neural Interface Technology
Park, M. C., Goldman, M. A., Belknap, T. W., & Friehs, G. M. (2009) · Springer eBooks · doi:10.1007/978-3-540-69960-6_193 · Cited by 7
Implanted intracortical electrodes as chronic neural interfaces to the central nervous systemPreprint
Henderson, P. (2015) · doi:10.7287/peerj.preprints.1255v1 · Cited by 5
Reliable neural interface: The first quarter century of the Neurotrophic Electrode
Kennedy, P. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346678 · Cited by 4
Self-citationEvaluation of post-fabrication thermoforming process for intracortical Parylene sheath electrode
Kim, B., Hara, S. A., Chen, B., Kuo, J. T. W., Lee, C. D., Gutierrez, C. A., Hoang, T., Gupta, M., Pikov, V., & Meng, E. F. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6695951 · Cited by 4
Preliminary study of neurite outgrowth within polyimide microtubes
Satish, L., Gandhi, D., & Rousche, P. J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404199 · Cited by 4
Intracranialbrain–computer interfaces for communication and control
Jarosiewicz, B., & Hochberg, L. R. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.042 · Cited by 4
Design of Electrodes for Efficient and Selective Electrical Stimulation of Nervous Tissue
Howell, B. L. (2015) · DukeSpace (Duke University) · Cited by 3
Neural Interfaces: from Human Nerves to Electronics
Falcone, J., Birjiniuk, J., Kretschmar, R., & Bellamkonda, R. V. (2014) · Wiley eBooks · doi:10.1002/9783527673148.ch6 · Cited by 2
Brain–Computer Interfacing Prospects and Technical Aspects
Bakay, R. O. Y. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6839-6.10120-0 · Cited by 2
Self-citationA System For Real Time Processing Of Neural Signals For Use As Prosthetic Controllers
Kennedy, P. R., Hopper, A., Linker, C., & Sharpe, S. M. (1992) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1992.5761821 · Cited by 3
Self-citationLiao, R. (2013) · SHAREOK (University of Oklahoma; Oklahoma State University; Central Oklahoma University) · Cited by 2
NEXT GENERATION OF CORTICAL DEVICES
Rousche, P. J., & Kipke, D. R. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0041 · Cited by 2
Development of Stable Long‐term Electrode Tissue Interfaces for Recording and Stimulation
Schouenborg, J. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch2 · Cited by 1
Selective surface activation of motor circuitry in the injured spinal cord
Meacham, K. (2008) · SMARTech Repository (Georgia Institute of Technology) · Cited by 1
Wavelet-based semblance methods to enhance single-trial ERP detection
Saavedra, C. (2013) · HAL · Cited by 1
Wavelet-based semblance methods to enhance single-trial ERP detection
SAAVEDRA RUIZ, C. V., Girau, B., & Bougrain, L. (2013) · theses.fr (ABES) · Cited by 1
Translational research: application to human neural injury
Selzer, M. E., Clarke, S., Cohen, L. G., Kwakkel, G., & Miller, R. H. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.039
SELECTIVE SURFACE ACTIVATION OF MOTOR CIRCUITRY IN
Meacham, K. (2008)
Potter, K. A. (2014) · OhioLink ETD Center (Ohio Library and Information Network)
Deliano, M. (2005) · Digitalen Hochschulbibliothek Sachsen-Anhalt (Universitäts- und Landesbibliothek Sachsen-Anhalt) · doi:10.25673/4681
Metadata
- Authors
- Kennedy, P. R., Mirra, S. S., & Bakay, R. A. E.
- Affiliations
- Georgia Institute of Technology (US)
- Emory University (US)
- Corresponding author
- Kennedy, Philip R.
- Venue
- Neuroscience Letters
- Publisher
- Elsevier BV
- Published
- 1992-08
- Volume
- 142
- Issue
- 1
- Pages
- 89-94
- ISSN
- 0304-3940 (ISSN-L)
- OpenAlex
- W2090690428
- Semantic Scholar
- ed8e9c17854528d6b6c733faff8ec0c2d941fe82
- Cited by
- 81
- References
- 13
- Citations by year
- 2023: 1 · 2022: 2 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 3 · 2016: 8 · 2015: 8 · 2014: 4 · 2013: 5 · 2012: 6
- FWCI
- 0.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Neuroscience Letters (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Research Resources (RR-00 165, P51RR000165)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
- Keywords
- long-term neural recording, cerebral cortex, myelinated axons, dendrites, glia, blood vessels, rats, monkeys
- MeSH terms
- Animals, Haplorhini, Axons, Cerebral Cortex, Collagen, Drug Combinations, Electrodes, Implanted, Electrophysiology, Equipment Design, Laminin, Microscopy, Electron, Myelin Sheath, Nerve Fibers, Myelinated, Proteoglycans, Sciatic Nerve, Time Factors, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.