The DOI matches its Crossref record; 105 of the 105 references it cites were found in a registry or an index.
Raman spectroscopy for medical diagnostics — From in-vitro biofluid assays to in-vivo cancer detection
Open accessAbstract
Raman spectroscopy is an optical technique based on inelastic scattering of light by vibrating molecules and can provide chemical fingerprints of cells, tissues or biofluids. The high chemical specificity, minimal or lack of sample preparation and the ability to use advanced optical technologies in the visible or near-infrared spectral range (lasers, microscopes, fibre-optics) have recently led to an increase in medical diagnostic applications of Raman spectroscopy. The key hypothesis underpinning this field is that molecular changes in cells, tissues or biofluids, that are either the cause or the effect of diseases, can be detected and quantified by Raman spectroscopy. Furthermore, multivariate calibration and classification models based on Raman spectra can be developed on large "training" datasets and used subsequently on samples from new patients to obtain quantitative and objective diagnosis. Historically, spontaneous Raman spectroscopy has been known as a low signal technique requiring relatively long acquisition times. Nevertheless, new strategies have been developed recently to overcome these issues: non-linear optical effects and metallic nanoparticles can be used to enhance the Raman signals, optimised fibre-optic Raman probes can be used for real-time in-vivo single-point measurements, while multimodal integration with other optical techniques can guide the Raman measurements to increase the acquisition speed and spatial accuracy of diagnosis. These recent efforts have advanced Raman spectroscopy to the point where the diagnostic accuracy and speed are compatible with clinical use. This paper reviews the main Raman spectroscopy techniques used in medical diagnostics and provides an overview of various applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Moskovits, M. (1985) · Reviews of Modern Physics · doi:10.1103/revmodphys.57.783 · Cited by 5,466
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Estimates of the cancer incidence and mortality in Europe in 2006
Ferlay, J., Autier, P., Boniol, M., Heanue, M., Colombet, M., & Boyle, P. (2007) · Annals of Oncology · doi:10.1093/annonc/mdl498 · Cited by 4,036
Anomalously intense Raman spectra of pyridine at a silver electrode
Albrecht, M. G., & Creighton, J. A. (1977) · Journal of the American Chemical Society · doi:10.1021/ja00457a071 · Cited by 2,902
Global malaria mortality between 1980 and 2010: a systematic analysis
Murray, C. J., Rosenfeld, L. C., Lim, S. S., Andrews, K. G., Foreman, K. J., Haring, D., Fullman, N., Naghavi, M., Lozano, R., & Lopez, A. D. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60034-8 · Cited by 1,452
Surface-enhanced Raman scattering
Otto, A., Mrozek, I., Grabhorn, H., & Akemann, W. (1992) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/4/5/001 · Cited by 1,428
Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Cheng, J.-X., & Xie, X. S. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp035693v · Cited by 963
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Video-Rate Molecular Imaging in Vivo with Stimulated Raman Scattering
Saar, B. G., Freudiger, C. W., Reichman, J., Stanley, C. M., Holtom, G. R., & Xie, X. S. (2010) · Science · doi:10.1126/science.1197236 · Cited by 844
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., & Porter, M. D. (2003) · Analytical Chemistry · doi:10.1021/ac034356f · Cited by 779
Plasmon-Sampled Surface-Enhanced Raman Excitation Spectroscopy
Haynes, C. L., & Van Duyne, R. P. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp027749b · Cited by 696
Micro-Raman Spectroscopy Detects Individual Neoplastic and Normal Hematopoietic Cells
Chan, J. W., Taylor, D. S., Zwerdling, T., Lane, S. M., Ihara, K., & Huser, T. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.066761 · Cited by 679
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
Erythrocyte Membrane Lipid Peroxidation and Glycosylated Hemoglobin in Diabetes
Jain, S. K., McVie, R., Duett, J., & Herbst, J. J. (1989) · Diabetes · doi:10.2337/diab.38.12.1539 · Cited by 639
Diagnosing breast cancer by using Raman spectroscopy
Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501390102 · Cited by 630
Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy
Matousek, P., Clark, I. P., Draper, E. R. C., Morris, M. D., Goodship, A. E., Everall, N., Towrie, M., Finney, W. F., & Parker, A. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053641450 · Cited by 548
Rapid, Label-Free Detection of Brain Tumors with Stimulated Raman Scattering Microscopy
Ji, M., Orringer, D. A., Freudiger, C. W., Ramkissoon, S., Liu, X., Lau, D., Golby, A. J., Norton, I., Hayashi, M., Agar, N. Y. R., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005954 · Cited by 513
Raman Assessment of Bone Quality
Morris, M. D., & Mandair, G. S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1692-y · Cited by 511
High-speed coherent Raman fingerprint imaging of biological tissues
Camp Jr, C. H., Lee, Y. J., Heddleston, J. M., Hartshorn, C. M., Walker, A. R. H., Rich, J. N., Lathia, J. D., & Cicerone, M. T. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.145 · Cited by 469
Mosterd, K., Krekels, G. A., Nieman, F. H., Ostertag, J. U., Essers, B. A., Dirksen, C. D., Steijlen, P. M., Vermeulen, A., Neumann, H., & Kelleners-Smeets, N. W. (2008) · The Lancet Oncology · doi:10.1016/s1470-2045(08)70260-2 · Cited by 466
Raman microprobe and microscope with laser excitation
Delhaye, M., & Dhamelincourt, P. (1975) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250030105 · Cited by 453
Raman spectroscopy: elucidation of biochemical changes in carcinogenesis of oesophagus
Shetty, G., Kendall, C., Shepherd, N., Stone, N., & Barr, H. (2006) · British Journal of Cancer · doi:10.1038/sj.bjc.6603102 · Cited by 446
Self-citationReal-time Raman Spectroscopy for In Vivo Skin Cancer Diagnosis
Lui, H., Zhao, J., McLean, D., & Zeng, H. (2012) · Cancer Research · doi:10.1158/0008-5472.can-11-4061 · Cited by 429
Discriminating Basal Cell Carcinoma from its Surrounding Tissue by Raman Spectroscopy
Bakker Schut, T. C., Caspers, P. J., Puppels, G. J., Nijssen, A., Heule, F., Neumann, M. H. A., & Hayes, D. P. (2002) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2002.01807.x · Cited by 346
Shim, M. G., Wong Kee Song, L.-M., Marcon, N. E., & Wilson, B. C. (2000) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2000)0720146ivnirs2.0.co2 · Cited by 296
Molckovsky, A., Song, L.-M. W. K., Shim, M. G., Marcon, N. E., & Wilson, B. C. (2003) · Gastrointestinal Endoscopy · doi:10.1067/mge.2003.105 · Cited by 265
Bone tissue compositional differences in women with and without osteoporotic fracture
McCreadie, B. R., Morris, M. D., Chen, T.-C., Sudhaker Rao, D., Finney, W. F., Widjaja, E., & Goldstein, S. A. (2006) · Bone · doi:10.1016/j.bone.2006.06.008 · Cited by 253
Kendall, C., Stone, N., Shepherd, N., Geboes, K., Warren, B., Bennett, R., & Barr, H. (2003) · The Journal of Pathology · doi:10.1002/path.1376 · Cited by 245
Self-citationGood, D. M., Thongboonkerd, V., Novak, J., Bascands, J.-L., Schanstra, J. P., Coon, J. J., Dominiczak, A., & Mischak, H. (2007) · Journal of Proteome Research · doi:10.1021/pr070529w · Cited by 244
Kong, K., Rowlands, C. J., Varma, S., Perkins, W., Leach, I. H., Koloydenko, A. A., Williams, H. C., & Notingher, I. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1311289110 · Cited by 234
Self-citationTeh, S. K., Zheng, W., Ho, K. Y., Teh, M., Yeoh, K. G., & Huang, Z. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604176 · Cited by 230
In vivo nonmelanoma skin cancer diagnosis using Raman microspectroscopy
Lieber, C. A., Majumder, S. K., Ellis, D. L., Billheimer, D. D., & Mahadevan‐Jansen, A. (2008) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20653 · Cited by 218
Raman spectroscopy and multivariate analysis of serum samples from breast cancer patients
Pichardo-Molina, J. L., Frausto-Reyes, C., Barbosa-García, O., Huerta-Franco, R., González-Trujillo, J. L., Ramírez-Alvarado, C. A., Gutiérrez-Juárez, G., & Medina-Gutiérrez, C. (2007) · Lasers in Medical Science · doi:10.1007/s10103-006-0432-8 · Cited by 212
Crow, P., Molckovsky, A., Stone, N., Uff, J., Wilson, B., & WongKeeSong, L.-M. (2005) · Urology · doi:10.1016/j.urology.2004.12.058 · Cited by 208
Self-citationNondestructive Identification of Individual Leukemia Cells by Laser Trapping Raman Spectroscopy
Chan, J. W., Taylor, D. S., Lane, S. M., et al. (2008) · Analytical Chemistry · doi:10.1021/ac7022348 · Cited by 199
Raman Microspectroscopy: A Comparison of Point, Line, and Wide-Field Imaging Methodologies
Schlücker, S., Schaeberle, M. D., Huffman, S. W., & Levin, I. W. (2003) · Analytical Chemistry · doi:10.1021/ac034169h · Cited by 198
Dochow, S., Krafft, C., Neugebauer, U., Bocklitz, T., Henkel, T., Mayer, G., Albert, J., & Popp, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00612b · Cited by 197
The use of Raman spectroscopy to differentiate between different prostatic adenocarcinoma cell lines
Crow, P., Barrass, B., Kendall, C., Hart-Prieto, M., Wright, M., Persad, R., & Stone, N. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602638 · Cited by 195
Self-citationIn Vivo Detection of Dysplastic Tissue by Raman Spectroscopy
Bakker Schut, T. C., Witjes, M. J. H., Sterenborg, H. J. C. M., Speelman, O. C., Roodenburg, J. L. N., Marple, E. T., Bruining, H. A., & Puppels, G. J. (2000) · Analytical Chemistry · doi:10.1021/ac000780u · Cited by 194
Classification of colonic tissues using near-infrared Raman spectroscopy and support vector machines
Widjaja, E., Zheng, W., & Huang, Z. (2008) · International Journal of Oncology · doi:10.3892/ijo.32.3.653 · Cited by 193
Diagnosing breast cancer using Raman spectroscopy: prospective analysis
Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Shenk, R., Wang, N., Dasari, R. R., Fitzmaurice, M., & Feld, M. S. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3247154 · Cited by 193
The use of Raman spectroscopy to identify and grade prostatic adenocarcinoma in vitro
Crow, P., Stone, N., Kendall, C. A., Uff, J. S., Farmer, J. A. M., Barr, H., & Wright, M. P. J. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6601059 · Cited by 189
Self-citationMa, K., Yuen, J. M., Shah, N. C., Walsh, J. T., Glucksberg, M. R., & Van Duyne, R. P. (2011) · Analytical Chemistry · doi:10.1021/ac202343e · Cited by 184
Surface enhanced spatially offset Raman spectroscopic (SESORS) imaging – the next dimension
Stone, N., Kerssens, M., Lloyd, G. R., Faulds, K., Graham, D., & Matousek, P. (2011) · Chemical Science · doi:10.1039/c0sc00570c · Cited by 183
Self-citationYuen, J. M., Shah, N. C., Walsh, J. T., Glucksberg, M. R., & Van Duyne, R. P. (2010) · Analytical Chemistry · doi:10.1021/ac101951j · Cited by 183
Recent advances in the development of Raman spectroscopy for deep non‐invasive medical diagnosis
Matousek, P., & Stone, N. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201200141 · Cited by 164
Self-citationRaman spectroscopic imaging for in vivo detection of cerebral brain metastases
Kirsch, M., Schackert, G., Salzer, R., & Krafft, C. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4116-7 · Cited by 159
Advanced Transmission Raman Spectroscopy: A Promising Tool for Breast Disease Diagnosis
Stone, N., & Matousek, P. (2008) · Cancer Research · doi:10.1158/0008-5472.can-07-6557 · Cited by 158
Self-citationSchütz, M., Steinigeweg, D., Salehi, M., Kömpe, K., & Schlücker, S. (2011) · Chemical Communications · doi:10.1039/c0cc05229a · Cited by 158
Nonlinear microscopy, infrared, and Raman microspectroscopy for brain tumor analysis
Meyer, T., Bergner, N., Bielecki, C., Krafft, C., Akimov, D., Romeike, B. F. M., Reichart, R., Kalff, R., Dietzek, B., & Popp, J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3533268 · Cited by 158
Bulk Raman Analysis of Pharmaceutical Tablets
Matousek, P., & Parker, A. W. (2006) · Applied Spectroscopy · doi:10.1366/000370206779321463 · Cited by 156
In Vivo Diagnosis of Esophageal Cancer Using Image-Guided Raman Endoscopy and Biomolecular Modeling
Bergholt, M. S., Zheng, W., Lin, K.-W., Ho, K. Y., Teh, M., Yeoh, K. G., So, J. B. Y., & Huang, Z. (2011) · Technology in Cancer Research & Treatment · doi:10.7785/tcrt.2012.500185 · Cited by 148
Stone, N., Faulds, K., Graham, D., & Matousek, P. (2010) · Analytical Chemistry · doi:10.1021/ac100039c · Cited by 140
Self-citationSchulmerich, M. V., Dooley, K. A., Morris, M. D., Vanasse, T. M., & Goldstein, S. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2400233 · Cited by 136
Li, S., Zhang, Y., Xu, J., Li, L., Zeng, Q., Lin, L., Guo, Z., Liu, Z., Xiong, H., & Liu, S. (2014) · Applied Physics Letters · doi:10.1063/1.4892667 · Cited by 133
Stone, N., Prieto, M. C., Crow, P., Uff, J., & Ritchie, A. W. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0937-9 · Cited by 131
Self-citationFiber-Optic Probes for in Vivo Raman Spectroscopy in the High-Wavenumber Region
Santos, L. F., Wolthuis, R., Koljenović, S., Almeida, R. M., & Puppels, G. J. (2005) · Analytical Chemistry · doi:10.1021/ac0505730 · Cited by 131
Endoscopic Raman spectroscopy enables objective diagnosis of dysplasia in Barrett's esophagus
Almond, M., Hutchings, J. C., Lloyd, G. R., Barr, H., Shepherd, N. A., Day, J. C. C., Stevens, O. A. C., Sanders, S., Wadley, M., Stone, N., et al. (2013) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2013.05.028 · Cited by 124
Self-citationDrop coating deposition Raman spectroscopy of protein mixtures
Filik, J., & Stone, N. (2007) · The Analyst · doi:10.1039/b701541k · Cited by 123
Self-citationHuang, Z., Teh, S. K., Zheng, W., Mo, J., Lin, K., Shao, X., Ho, K. Y., Teh, M., & Yeoh, K. G. (2009) · Optics Letters · doi:10.1364/ol.34.000758 · Cited by 122
Bergholt, M. S., Zheng, W., Lin, K., Huang, Z., Ho, K. Y., Yeoh, K. G., Teh, M., & So, J. B. Y. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3556723 · Cited by 121
Rehman, I. U., Smith, R., Hench, L. L., & Bonfield, W. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291016 · Cited by 119
MacLaughlin, C. M., Mullaithilaga, N., Yang, G., Ip, S. Y., Wang, C., & Walker, G. C. (2013) · Langmuir · doi:10.1021/la303931c · Cited by 114
Optical Techniques for the Endoscopic Detection of Early Dysplastic Colonic Lesions
DaCosta, R. S., Wilson, B. C., & Marcon, N. E. (2003) · Wiley eBooks · doi:10.1002/9780470986943.ch44 · Cited by 109
Quantitative analysis of serum and serum ultrafiltrate by means of Raman spectroscopy
Rohleder, D., Kiefer, W., & Petrich, W. H. (2004) · The Analyst · doi:10.1039/b408927h · Cited by 109
Analysis of human tear fluid by Raman spectroscopy
Filik, J., & Stone, N. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.036 · Cited by 108
Self-citationEmerging technology: applications of Raman spectroscopy for prostate cancer
Kast, R. E., Tucker, S. C., Killian, K., Trexler, M., Honn, K. V., & Auner, G. W. (2014) · Cancer and Metastasis Reviews · doi:10.1007/s10555-013-9489-6 · Cited by 105
Matousek, P., & Stone, N. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2718934 · Cited by 103
Self-citationEmerging concepts in deep Raman spectroscopy of biological tissue
Matousek, P., & Stone, N. (2009) · The Analyst · doi:10.1039/b821100k · Cited by 102
Self-citationQi, D., & Berger, A. J. (2007) · Applied Optics · doi:10.1364/ao.46.001726 · Cited by 101
Development of Raman microspectroscopy for automated detection and imaging of basal cell carcinoma
Larraona-Puy, M., Ghita, A., Zoladek, A., Perkins, W. A., Varma, S., LEACH, I. H., Koloydenko, A. A., Williams, H. C., & Notingher, I. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3251053 · Cited by 99
Self-citationA miniature confocal Raman probe for endoscopic use
Day, J. C. C., Bennett, R. D., Smith, B., Kendall, C. A., Hutchings, J. C., Meaden, G. M., Born, C., Yu, S., & Stone, N. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/23/003 · Cited by 91
Self-citationUckermann, O., Galli, R., Tamošaitytė, S., Leipnitz, E., Geiger, K. D., Schackert, G., Koch, E., Steiner, G. R., & Kirsch, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0107115 · Cited by 91
Depth profiling of calcifications in breast tissue using picosecond Kerr-gated Raman spectroscopy
Baker, R. N., Matousek, P., Ronayne, K. L., Parker, A. W., Rogers, K. D., & Stone, N. (2006) · The Analyst · doi:10.1039/b614388a · Cited by 87
Self-citationSpectral discrimination of live prostate and bladder cancer cell lines using Raman optical tweezers
Harvey, T. J., Faria, E. C., Henderson, A., Gazi, E., Ward, A. D., Clarke, N. W., Brown, M. D., Snook, R. D., & Gardner, P. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2999609 · Cited by 78
Potential for Raman spectroscopy to provide cancer screening using a peripheral blood sample
Harris, A. T., Lungari, A., Needham, C. J., Smith, S. L., Lones, M. A., Fisher, S. E., Yang, X., Cooper, N. S., Kirkham, J., Smith, D. A., et al. (2009) · Head & Neck Oncology · doi:10.1186/1758-3284-1-34 · Cited by 78
Raman spectroscopic analysis of malaria disease progression via blood and plasma samples
Hobro, A. J., Konishi, A., Coban, C., & Smith, N. I. (2013) · The Analyst · doi:10.1039/c3an00255a · Cited by 75
Krafft, C., Belay, B., Bergner, N., Romeike, B. F. M., Reichart, R., Kalff, R., & Popp, J. (2012) · The Analyst · doi:10.1039/c2an36083g · Cited by 74
Characterization of breast duct epithelia: a Raman spectroscopic study
Kneipp, J., Schut, T. C. B., Kliffen, M., Menke‐Pluijmers, M. B. E., & Puppels, G. J. (2003) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(03)00048-1 · Cited by 73
Yang, Y., Li, F., Gao, L. S., Wang, Z., Thrall, M. J., Shen, S. S., Wong, K., & Wong, S. T. C. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002160 · Cited by 71
Raman Spectroscopic Characterization of Porcine Brain Tissue Using a Single Fiber-Optic Probe
Koljenović, S., Schut, T. C. B., Wolthuis, R., Vincent, A. J. P. E., Hendriks-Hagevi, G., Santos, L. F., Kros, J. M., & Puppels, G. J. (2006) · Analytical Chemistry · doi:10.1021/ac0616512 · Cited by 70
Raman Spectral Mapping in the Assessment of Axillary Lymph Nodes in Breast Cancer
Smith, J., Kendall, C. A., Sammon, A. M., Christie-Brown, J., & Stone, N. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200407 · Cited by 69
Self-citationTaleb, I., Thiéfin, G., Gobinet, C., Untereiner, V., Bernard‐Chabert, B., Heurgué, A., Truntzer, C., Hillon, P., Manfait, M., Ducoroy, P., et al. (2013) · The Analyst · doi:10.1039/c3an00245d · Cited by 66
Poon, K. W. C., Lyng, F. M., Knief, P., Howe, O. L., Meade, A. D., Curtin, J. F., Byrne, H. J., & Vaughan, J. (2012) · The Analyst · doi:10.1039/c2an35042d · Cited by 66
A Subcutaneous Raman Needle Probe
Day, J. C. C., & Stone, N. (2013) · Applied Spectroscopy · doi:10.1366/12-06651 · Cited by 65
Self-citationClassification of fixed urological cells using Raman tweezers
Harvey, T. J., Hughes, C. S., Ward, A. D., Faria, E. C., Henderson, A., Clarke, N. W., Brown, M. D., Snook, R. D., & Gardner, P. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200810061 · Cited by 63
Line-Scan Raman Microspectrometry for Biological Applications
de Grauw, C. J., Otto, C., & Greve, J. W. M. (1997) · Applied Spectroscopy · doi:10.1366/0003702971939587 · Cited by 62
Raman spectroscopy—A new method for the intra-operative assessment of axillary lymph nodes
Horsnell, J., Stonelake, P. S., Christie-Brown, J., Shetty, G., Hutchings, J. C., Kendall, C. A., & Stone, N. (2010) · The Analyst · doi:10.1039/c0an00527d · Cited by 60
Self-citationMultimodal mapping of human skin
Heuke, S., Vogler, N., Meyer, T., Akimov, D., Kluschke, F., Röwert‐Huber, H., Lademann, J. M., Dietzek, B., & Popp, J. (2013) · British Journal of Dermatology · doi:10.1111/bjd.12427 · Cited by 60
Bergner, N., Medyukhina, A., Geiger, K. D., Kirsch, M., Schackert, G., Krafft, C., & Popp, J. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7257-7 · Cited by 50
Filik, J., & Stone, N. (2008) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2113 · Cited by 49
Self-citationXie, H., Stevenson, R., Stone, N., Hernández-Santana, A., Faulds, K., & Graham, D. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201203728 · Cited by 49
Self-citationBonifacio, A., Finaurini, S., Krafft, C., Parapini, S., Taramelli, D., & Sergo, V. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2414-0 · Cited by 43
Raman endoscopy for the in situ investigation of advancing colorectal tumors in live model mice
Taketani, A., Hariyani, R., Ishigaki, M., Andriana, B. B., & Sato, H. (2013) · The Analyst · doi:10.1039/c3an00169e · Cited by 41
Kerns, J. G., Gikas, P. D., Buckley, K., Shepperd, A., Birch, H. L., McCarthy, I., Miles, J., Briggs, T. W. R., Keen, R. W., Parker, A. W., et al. (2014) · Arthritis & Rheumatology · doi:10.1002/art.38360 · Cited by 40
Hutchings, J. C., Kendall, C. A., Shepherd, N. A., Barr, H., & Stone, N. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3512244 · Cited by 36
Self-citationDifferential Diagnosis of Lung Carcinoma With Coherent Anti-Stokes Raman Scattering Imaging
Gao, L. S., Wang, Z., Li, F., Hammoudi, A. A., Thrall, M. J., Cagle, P. T., & Wong, S. T. C. (2012) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2012-0238-sa · Cited by 33
Towards automated segmentation of cells and cell nuclei in nonlinear optical microscopy
Medyukhina, A., Meyer, T., Schmitt, M. P., Romeike, B. F. M., Dietzek, B., & Popp, J. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200096 · Cited by 30
Optical adjuncts for enhanced colonoscopic diagnosis
Taylor, J. C., Kendall, C. A., Stone, N., & Cook, T. A. (2007) · British journal of surgery · doi:10.1002/bjs.5628 · Cited by 27
Self-citationHistological imaging of a human colon polyp sample using Raman spectroscopy and self organising maps
Lloyd, G. R., Wood, J., Kendall, C. A., Cook, T. A., Shepherd, N. A., & Stone, N. (2012) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2012.02.015 · Cited by 24
Self-citationLin, J., Zeng, Y., Lin, J., Wang, J., Li, L., Huang, Z., Li, B., Zeng, H., & Chen, R. (2014) · Applied Physics Letters · doi:10.1063/1.4868390 · Cited by 15
Automated seeding-based nuclei segmentation in nonlinear optical microscopy
Medyukhina, A., Meyer, T., Heuke, S., Vogler, N., Dietzek, B., & Popp, J. (2013) · Applied Optics · doi:10.1364/ao.52.006979 · Cited by 11
Respiratory viruses as a cause of sudden death
Garcia, M., Beby‐Defaux, A., & Lévêque, N. (2016) · Expert Review of Anti-infective Therapy · doi:10.1586/14787210.2016.1157470 · Cited by 10
Cited by
Present and Future of Surface-Enhanced Raman Scattering
Langer, J., Jimenez de Aberasturi, D., Aizpurua, J., Alvarez-Puebla, R. A., Auguié, B., Baumberg, J. J., Bazan, G. C., Bell, S. E. J., Boisen, A., Brolo, A. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b04224 · Cited by 3,880
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Surface-enhanced Raman spectroscopy for in vivo biosensing
Laing, S., Jamieson, L. E., Faulds, K., & Graham, D. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0060 · Cited by 442
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Self-citationApplications of Raman spectroscopy in cancer diagnosis
Auner, G. W., Koya, S. K., Huang, C., Broadbent, B., Trexler, M., Auner, Z., Elias, A., Mehne, K. C., & Brusatori, M. A. (2018) · Cancer and Metastasis Reviews · doi:10.1007/s10555-018-9770-9 · Cited by 385
Metadata
- Authors
- Kong, K., Kendall, C., Stone, N., & Notingher, I.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2015-07
- Volume
- 89
- Pages
- 121-134
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W1968871412
- Cited by
- 653
- References
- 105
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.