Cited by 303ECG Monitoring and AnalysisCardiac pacing and defibrillation studiesCardiac electrophysiology and arrhythmias

The DOI matches its Crossref record; 328 of the 328 references it cites were found in a registry or an index; 83 of the 227 sources its claims cite were checked for support.

2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry

Open access
Steinberg, Jonathan S., Varma, Niraj, Cygankiewicz, Iwona, Aziz, Peter, Balsam, Paweł, Baranchuk, Adrian, Cantillon, Daniel J., Dilaveris, Polychronis, Dubner, Sergio J., El-Sherif, Nabil, Krol, Jaroslaw, Kurpesa, Malgorzata, La Rovere, Maria Teresa, Lobodzinski, Suave S., Locati, Emanuela T., Mittal, Suneet, Olshansky, Brian, Piotrowicz, Ewa, Saxon, Leslie, Stone, Peter H., Tereshchenko, Larisa, Turitto, Gioia, Wimmer, Neil J., Verrier, Richard L., Zareba, Wojciech, Piotrowicz, Ryszard·2017·Heart Rhythm

Abstract

Ambulatory ECG (AECG) is very commonly employed in a variety of clinical contexts to detect cardiac arrhythmias and/or arrhythmia patterns which are not readily obtained from the standard ECG. Accurate and timely characterization of arrhythmias is crucial to direct therapies that can have an important impact on diagnosis, prognosis or patient symptom status. The rhythm information derived from the large variety of AECG recording systems can often lead to appropriate and patient-specific medical and interventional management. The details in this document provide background and framework from which to apply AECG techniques in clinical practice, as well as clinical research.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2017.03.038

Cites

328 of 328 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

83 of 227 cited sources checked · 29 supported · 5 flagged · accuracy not yet measured

Show all 123 claims

  • It may state two separate claims as one. 100
  • Probably not a substantial claim. 51
  • The quote only partly states this claim. 2
131 of 131
  • The paper relies on this without support.

    A significant number of low-risk patients with syncope are unnecessarily admitted for further investigation.

    “A significant number of low-risk patients are unnecessarily admitted for further investigation, and a role for outpatient use of AECG can be offered as an alternative.”
  • The paper relies on this without support.

    Poor tolerability of wire-electrode systems, especially when recording is prolonged, and adverse skin reactions challenge patient compliance.

    “Poor tolerability of wire-electrode systems (especially when recording is prolonged) and adverse skin reactions challenge patient compliance.”
  • The paper relies on this without support.

    Failure by the technician or clinician to recognize a genuine arrhythmia episode is significantly more common on the hospital cardiac telemetry service.

    “This problem is significantly more common on the hospital cardiac telemetry service and highlights the need of improved training in the detection and interpretation of AECG of the technical and clinical staff who make up this service (See Section 6).”
  • The paper relies on this without support.

    Most ECG processing algorithms are proprietary, and very few data are available regarding their documented clinical accuracy.

    “Most are proprietary, and very few data are available regarding their documented clinical accuracy.”
  • The paper relies on this without support.

    The majority of artifacts can be recognized from simultaneous multichannel ECG.

    “The majority of artifacts can be recognized from simultaneous multichannel ECG.”
  • The paper relies on this without support.

    Early reperfusion via percutaneous coronary intervention is the critical therapeutic intervention for patients with ST elevation myocardial infarction.

    “In patients suffering ST elevation myocardial infarction (STEMI), early reperfusion via percutaneous coronary intervention (PCI) remains the critical therapeutic intervention.”
  • The paper relies on this without support.

    Most young children (under 5 years) are unable to comply with event-triggered monitoring.

    “Most young children (,5 years) are unable to comply with event triggered monitoring.”
  • The paper relies on this without support.

    Implantation according to current guidelines results in appropriate therapy in only about 20% of patients with ICDs.

    “Implantation according to current guidelines results in appropriate therapy in only about 20% of patients with ICDs.”
  • The paper relies on this without support.

    Current indications neglect the vast majority of patients vulnerable to SCD who have relatively preserved LVEF.

    “In addition, current indications neglect the vast majority of patients vulnerable to SCD who have relatively preserved LVEF.”
  • The paper relies on this without support.

    Suppression of arrhythmia should be considered when a reduction of 75% in isolated or coupled PVCs and 90% in VT episodes had been achieved.

    “Data from 1980s on the value of Holter monitoring in evaluation of efficacy of antiarrhythmic drugs indicated that suppression of arrhythmia should be considered when a reduction of 75% in isolated or coupled PVCs and 90% in VT episodes had been achieved.”
  • The paper relies on this without support.

    There is lower mortality and morbidity with decreased length of stay in hospitals that have adopted the E-ICU.

    “There is a lower mortality and morbidity with a decreased length of stay in hospitals that have adopted the so-called E-ICU.”
  • The paper relies on this without support.

    Vendors' nominal physician notification criteria often overestimate the clinical significance of captured arrhythmias and generate needless calls to physicians and/or Emergency Medical Services.

    “Vendors have established nominal physician notification criteria; these often overestimate the clinical significance of captured arrhythmias and generate needless calls to physicians and/or Emergency Medical Services.”
  • The paper relies on this without support.

    Myopotential inhibition, cross talk, and pacemaker-mediated tachycardia are infrequently encountered in Holter recordings performed in pacemaker patients.

    “Myopotential inhibition, cross talk, and pacemaker-mediated tachycardia, which constitute the major abnormalities in Holter recordings performed in pacemaker patients, are infrequently encountered, and may be detected and notified by remote monitoring, if and when they occur.”
  • The paper relies on this without support.

    Slow VT episodes below detection threshold can only be assessed externally.

    “Furthermore, slow VT episodes below detection threshold can only be assessed externally.”
  • The paper relies on this without support.

    As the number and chronicity of implantable devices increase, the number of patients undergoing explants for device problems and/or infections is increasing.

    “As the number and chronicity of implantable devices increase, the number of patients undergoing explants for device problems and/or infections is increasing.”
  • The paper relies on this without support.

    Responsibility of arrhythmia recognition and notification/escalation is not standardized and varies among hospitals from nursing, to monitoring technicians and even nonclinical personnel in some instances.

    “Responsibility of arrhythmia recognition and notification/escalation is not standardized and varies among hospitals from nursing, to monitoring technicians and even nonclinical personnel in some instances.”
  • The paper relies on this without support.

    Nominal alarm default settings are designed to be highly sensitive so as to not miss a clinically important event, but can also demonstrate poor specificity.

    “Nominal alarm default settings are designed to be highly sensitive so as to not miss a clinically important event, but can also demonstrate poor specificity.”
  • The paper relies on this without support.

    E-ICU has advantages for rural hospitals, decreases transfer to tertiary care hospitals, permits adherence to best critical care practices, and improves patient outcomes.

    “Overall, E-ICU has advantages for rural hospitals, decreases transfer to tertiary care hospitals, permits adherence to best critical care practices, and improves patient outcomes.”
  • The paper relies on this without support.

    There are 3 possible causes of the long RP tachycardia ECG pattern: low atrial tachycardia, fast-slow AV nodal reentrant tachycardia, and a circus movement tachycardia with V-A conduction over a slowly conducting AP.

    “We know of 3 possible causes of that ECG pattern: low atrial tachycardia, fast-slow AV nodal reentrant tachycardia, and a circus movement tachycardia with V-A conduction over a slowly conducting AP.”
19 of 19

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Left-leg electrode placement differs between text and figure

    Minor

    The description of the Mason-Likar lead system places the left-leg electrode on the anterior axillary line, whereas the figure caption places it on the midclavicular line.

  • Central-monitoring outcomes are called unpublished despite a cited publication

    Minor

    The paper says outcomes of central monitoring have not been published, but its reference list includes a 2016 JAMA article specifically about off-site central monitoring and clinical outcomes.

2 of 2

Citations

Cites

Items 201–328 of 328

Flagged first, then by citations

Research works printed but not linked: 3

  1. Dąbrowski, 1988, Circadian rhythm of sinoatrial conduction time. A new approach to the study of the sinoatrial node, Cardiovascular World Report, 1, 155
  2. Goldberger, 2007, Journal of the American College of Cardiology, 50, 225, 10.1016/j.jacc.2007.02.071 · DOI · Paper page
  3. International Conference on Harmonisation, 2005, Guidance on E14 Clinical Evaluation of QT/QTc interval prolongation and proarrhythmic potential for non-antiarrhythmic drugs; availability, Federal Register, 70, 61134

Cited by

Sorted by citations

See all 303

Metadata

Authors
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., Krol, J., Kurpesa, M., La Rovere, M. T., Lobodzinski, S. S., Locati, E. T., Mittal, S., Olshansky, B., Piotrowicz, E., Saxon, L., Stone, P. H., Tereshchenko, L., Turitto, G., Wimmer, N. J., Verrier, R. L., Zareba, W., & Piotrowicz, R.
Affiliations
  • University of Rochester Medicine (US)
  • Cleveland Clinic (US)
  • Medical University of Lodz (PL)
  • Medical University of Warsaw (PL)
  • Queen's University (CA)
  • National and Kapodistrian University of Athens (GR)
  • Valley Hospital (US)
  • University of Iowa (US)
  • Institute of Cardiology (PL)
  • University of Southern California (US)
  • Brigham and Women's Hospital (US)
  • Johns Hopkins University (US)
  • NewYork–Presbyterian Brooklyn Methodist Hospital (US)
  • Beth Israel Deaconess Medical Center (US)
Corresponding author
Steinberg, Jonathan S.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2017-07
Volume
14
Issue
7
Pages
e55-e96
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2613494736
Cited by
303
References
318
Citations by year
2026: 27 · 2025: 22 · 2024: 27 · 2023: 32 · 2022: 40 · 2021: 46 · 2020: 40 · 2019: 37 · 2018: 27 · 2017: 4
FWCI
22.78
Type
journal article
Language
en
Open access
Locations
  • Heart Rhythm (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Pfizer
  • State University of New York
  • Cleveland Clinic
  • University of Rochester
  • Boston Scientific Corporation
  • Queen's University
  • Warszawski Uniwersytet Medyczny
  • National and Kapodistrian University of Athens
  • Uniwersytet Łódzki
  • Uniwersytet Warszawski
  • Fondazione Salvatore Maugeri
  • National Institutes of Health
  • SUNY Downstate Medical Center
  • Biosense Webster
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
Holter monitoring, cardiac telemetry, cardiac arrhythmias, arrhythmia detection, heart rate variability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review