EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 1,301–1,311 of 1,311
Error Awareness Can Occur in the Absence of an Error‐Related Negativity
Dumsky, J., Maier, M. E., Di Gregorio, F., & Steinhauser, M. (2025) · Psychophysiology · doi:10.1111/psyp.70128 · Cited by 4
“An independent component analysis (Delorme and Makeig 2004) was computed, and independent components with blink artifacts were removed using CORRMAP (Campos Viola et al. 2009).”
Mild traumatic brain injury alters function in the dorsolateral prefrontal cortex: a TMS-EEG study
Moore, E., Webb, E., Sasaki, R., Rogasch, N. C., Foo, N., Semmler, J. G., & Opie, G. M. (2025) · doi:10.1101/2025.05.22.655676 · Cited by 3
“EEG data was analysed using MATLAB (R2021b, The Mathworks, USA) with EEGLAB (Delorme and Makeig 2004), Fieldtrip (Oostenveld et al. 2010) and the TMS-EEG signal analyser (TESA) (Rogasch et al. 2017) toolboxes, whereas figures were generated using the matplotlib toolbox in python (v3.”
Land, R., Sentis, S. C., & Kral, A. (2022) · Journal of Visualized Experiments · doi:10.3791/64034 · Cited by 3
Qin, Y., Xu, Q., Kujala, T., Wang, X., & Cong, F. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109535 · Cited by 1
Zhang, J., Liu, Y., Cai, W., Qi, S., Long, T., & Ge, B. (2024) · 2024 6th International Conference on Computer Science and Technologies in Education (CSTE) · doi:10.1109/cste62025.2024.00035 · Cited by 1
Valadez, E. A., Jopling, E., Macera, E., Wade, M., Zeanah, C. H., Nelson, C. A., & Fox, N. A. (2026) · Development and Psychopathology · doi:10.1017/s0954579426101928
Wang, J., Lin, Y., Xiao, Y., Zhu, Y., Gao, J., & Zheng, H. (2026) · Sleep Medicine · doi:10.1016/j.sleep.2025.108685
Random auditory stimulation during sleep disturbs traveling slow waves and declarative memory
Roüast, N. M., Kumral, D., Gais, S., & Schönauer, M. (2026) · iScience · doi:10.1016/j.isci.2026.116601
Ng, H.-Y. H., Hsu, A.-L., Wu, C. W., Huang, C.-M., Chao, Y.-P., Jung, T.-P., & Chuang, C.-H. (2026) · Mindfulness · doi:10.1007/s12671-025-02734-1
“Next, we used the EEGLAB toolbox 2021a (Swartz Center for Computational Neuroscience, University of California San Diego) (Delorme & Makeig, 2004) to downsample the data to 250 Hz and applied a 0.2–40 Hz band-pass finite impulse response (FIR) filter.”
InfluentialRen, G., Mahmoud, S. S., Kumar, A., Fang, Q., & Yu, B. (2023) · 2023 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10389146
“The raw data were spatially filtered using common average reference (CAR) and then filtered to 1-10 Hz using a finite impulse response (FIR) filter in the EEGLAB toolbox [13], as reported in [14].”
Method
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.