EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 801–900 of 1,309
The dynamic functional core network of the human brain at rest
Kabbara, A., Falou, W. E., Khalil, M. A., Wendling, F., & Hassan, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-03420-6 · Cited by 163
Semantic Context Enhances the Early Auditory Encoding of Natural Speech
Broderick, M. P., Anderson, A. J., & Lalor, E. C. (2019) · Journal of Neuroscience · doi:10.1523/jneurosci.0584-19.2019 · Cited by 162
van der Kooi, A. W., Zaal, I. J., Klijn, F. A., Koek, H. L., Meijer, R. C. A., Leijten, F. S. S., & Slooter, A. J. C. (2014) · CHEST Journal · doi:10.1378/chest.13-3050 · Cited by 163
Canales-Johnson, A., Silva, C., Huepe, D., Rivera-Rei, Á., Noreika, V., Garcia, M. D. C., Silva, W., Ciraolo, C., Vaucheret, E., Sedeño, L., et al. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhv076 · Cited by 146
“The EEGLABMatlab toolboxwas used for data preprocessing and pruning (Delorme and Makeig 2004).”
The Perception and Mimicry of Facial Movements Predict Judgments of Smile Authenticity
Korb, S., With, S., Niedenthal, P., Kaiser, S., & Grandjean, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099194 · Cited by 134
Harris, A. M., Hare, T. A., & Rangel, A. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.5816-12.2013 · Cited by 156
“Granger causality analysis was performed using the Granger Causal Connectivity Analysis toolbox (GCCA) for Matlab (MathWorks; Seth, 2010).”
MethodMedial prefrontal theta phase coupling during spatial memory retrieval
Kaplan, R., Bush, D., Bonnefond, M., Bandettini, P. A., Barnes, G. R., Doeller, C. F., & Burgess, N. (2014) · Hippocampus · doi:10.1002/hipo.22255 · Cited by 136
Ozdemir, R. A., Tadayon, E., Boucher, P., Momi, D., Karakhanyan, K. A., Fox, M. D., Halko, M. A., Pascual-Leone, A., Shafi, M. M., & Santarnecchi, E. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1911240117 · Cited by 142
How Sensitive Are EEG Results to Preprocessing Methods: A Benchmarking Study
Robbins, K. A., Touryan, J., Mullen, T. R., Kothe, C. A., & Bigdely-Shamlo, N. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2980223 · Cited by 146
Mattioli, F., Porcaro, C., & Baldassarre, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac4430 · Cited by 146
RetractedMørup, M., Hansen, L. K., & Arnfred, S. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.11.008 · Cited by 150
Multi-channel EEG recordings during 3,936 grasp and lift trials with varying weight and friction
Luciw, M., Jarocka, E., & Edin, B. B. (2014) · Scientific Data · doi:10.1038/sdata.2014.47 · Cited by 146
Human Scalp Electroencephalography Reveals that Repetition Suppression Varies with Expectation
Summerfield, C., Wyart, V., Johnen, V. M., & de Gardelle, V. (2011) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2011.00067 · Cited by 145
“EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.”
MethodAricò, P., Borghini, G., Di Flumeri, G., Colosimo, A., Pozzi, S., & Babiloni, F. (2016) · Progress in Brain Research · doi:10.1016/bs.pbr.2016.04.021 · Cited by 145
Impaired slow wave sleep downscaling in encephalopathy with status epilepticus during sleep (ESES)
Bölsterli, B. K., Schmitt, B., Bast, T., Critelli, H., Heinzle, J., Jenni, O. G., & Huber, R. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.01.053 · Cited by 150
Theta Phase Modulates Multiple Layer-Specific Oscillations in the CA1 Region
Scheffer-Teixeira, R., Belchior, H., Caixeta, F. V., Souza, B. C., Ribeiro, S., & Tort, A. B. L. (2012) · Cerebral Cortex · doi:10.1093/cercor/bhr319 · Cited by 140
Brain-Computer Interface Based on Generation of Visual Images
Дмитриевич, Б. П., Frolov, A., Cantor, C. R., Fedulova, I., Bakhnyan, M. K., & Zhavoronkov, A. A. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020674 · Cited by 165
Swann, N. C., de Hemptinne, C., Miocinovic, S., Qasim, S., Ostrem, J. L., Galifianakis, N. B., Luciano, M. S., Wang, S. S., Ziman, N., Taylor, R., et al. (2018) · Journal of Neurosurgery · doi:10.3171/2016.11.jns161162 · Cited by 143
A human prefrontal-subthalamic circuit for cognitive control
Kelley, R. M., Flouty, O. E., Emmons, E. B., Kim, Y.-C., Kingyon, J. R., Wessel, J. R., Oya, H., Greenlee, J. D. W., & Narayanan, N. S. (2017) · Brain · doi:10.1093/brain/awx300 · Cited by 154
Jas, M., Larson, E., Engemann, D. A., Leppäkangas, J., Taulu, S., Hämäläinen, M., & Gramfort, A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00530 · Cited by 152
A comparison between scalp- and source-reconstructed EEG networks
Lai, M., Demuru, M., Hillebrand, A., & Fraschini, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-30869-w · Cited by 153
Joint independent component analysis for simultaneous EEG–fMRI: Principle and simulation
Moosmann, M., Eichele, T., Nordby, H., Hugdahl, K., & Calhoun, V. D. (2007) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.05.016 · Cited by 158
Convolutional Neural Network for Multi-Category Rapid Serial Visual Presentation BCI
Manor, R., & Geva, A. B. (2015) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2015.00146 · Cited by 144
“Since the weights of this layer represent the EEG channels, we treat it as a spatial distribution across the scalp and plot on a head-plot using EEGLAB (Delorme and Makeig, 2004).”
MethodRousselet (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00137 · Cited by 142
“Hence, this kind of optimized 2004), as implemented in the runica EEGLAB function (Delorme and Makeig, 2004; Delorme et al., 2007) was then computed and we removed components corresponding to blink activity, identified by visual inspection of their scalp topographies, time-courses and activity…”
MethodNeural Signatures of Conscious Face Perception in an Inattentional Blindness Paradigm
Shafto, J. P., & Pitts, M. A. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.0145-15.2015 · Cited by 128
Oscillatory activity during maintenance of spatial and temporal information in working memory
Roberts, B. M., Hsieh, L.-T., & Ranganath, C. (2013) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2012.10.009 · Cited by 141
“The EEGLAB toolbox (Delorme & Makeig, 2004) in Matlab was used in all EEG data analyses.”
MethodFrömer, R., Maier, M., & Rahman, R. A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00048 · Cited by 160
Detection of major depressive disorder using linear and non-linear features from EEG signals
Mahato, S., & Paul, S. (2018) · Microsystem Technologies · doi:10.1007/s00542-018-4075-z · Cited by 150
Felice, A. D., Castiglia, L., Formaggio, E., Cattelan, M., Scarpa, B., Manganotti, P., Tenconi, E., & Masiero, S. (2019) · NeuroImage Clinical · doi:10.1016/j.nicl.2019.101768 · Cited by 154
A Deep Neural Network for SSVEP-Based Brain-Computer Interfaces
Güney, O. B., Oblokulov, M., & Özkan, H. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3110440 · Cited by 155
The brain matures with stronger functional connectivity and decreased randomness of its network
Smit, D. J. A., Boersma, M., Schnack, H. G., Micheloyannis, S., Boomsma, D. I., Hulshoff Pol, H. E., Stam, C. J., & de Geus, E. J. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0036896 · Cited by 143
“Next, we used the extended ICA decomposition implemented in EEGLA [39] to remove artifacts, including eye movements, and blink [40].”
MethodDreaming in NREM Sleep: A High-Density EEG Study of Slow Waves and Spindles
Siclari, F., Bernardi, G., Cataldi, J., & Tononi, G. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.0855-18.2018 · Cited by 143
“To remove ocular, muscular, and electrocardiograph artifacts, we performed independent component analysis (ICA) using EEGLAB routines (Delorme and Makeig, 2004).”
MethodTemporal dynamics of access to consciousness in the attentional blink
Kranczioch, C., Debener, S., Maye, A., & Engel, A. K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.044 · Cited by 143
“If F is the (complex) representation of the signal in the frequency space, i.e. Fðt; f Þ ¼ wðt; f Þ*xðtÞ; ð1Þ where x(t) is the signal and * designates convolution, then the ITC is obtained as ITC ¼ X F X jFj: ð2Þ (Delorme and Makeig, 2004 ).”
MethodLuft, C. D. B., & Bhattacharya, J. (2015) · Scientific Reports · doi:10.1038/srep15717 · Cited by 143
“The EEG data were processed and analyzed using MATLAB custom scripts and the following toolboxes: EEGLAB 55 for data preprocessing, including Independent Component Analysis (ICA), and Fieldtrip 56 for the non-parametric cluster permutation analysis.”
Scalable Tensor Factorizations with Missing Data
Acar, E., Dunlavy, D., Kolda, T. G., & Mørup, M. (2010) · SIAM International Conference on Data Mining · doi:10.1137/1.9781611972801.61 · Cited by 143
The Smartphone Brain Scanner: A Portable Real-Time Neuroimaging System
Stopczynski, A., Stahlhut, C., Larsen, J. E., Petersen, M. K., & Hansen, L. K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086733 · Cited by 154
The EEG correlates of the TMS-induced EMG silent period in humans
Farzan, F., Barr, M. S., Hoppenbrouwers, S. S., Fitzgerald, P. B., Chen, R., Pascual-Leone, A., & Daskalakis, Z. J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.059 · Cited by 136
“Inc. Natick, MA, USA) and further analyses were carried out by the open source signal processing functions available in the EEGLAB toolbox version 11b (Delorme and Makeig, 2004).”
InfluentialNegligible Motion Artifacts in Scalp Electroencephalography (EEG) During Treadmill Walking
Nathan, K., & Contreras-Vidal, J. L. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00708 · Cited by 151
Malcolm, B. R., Foxe, J. J., Butler, J. S., & Sanctis, P. D. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.028 · Cited by 156
Voineskos, D., Blumberger, D. M., Zomorrodi, R., Rogasch, N. C., Farzan, F., Foussias, G., Rajji, T. K., & Daskalakis, Z. J. (2018) · Biological Psychiatry · doi:10.1016/j.biopsych.2018.09.032 · Cited by 153
Multiple mechanisms link prestimulus neural oscillations to sensory responses
Iemi, L., Busch, N. A., Laudini, A., Haegens, S., Samaha, J., Villringer, A., & Nikulin, V. V. (2019) · eLife · doi:10.7554/elife.43620 · Cited by 134
An Optimal Channel Selection for EEG-Based Depression Detection via Kernel-Target Alignment
Shen, J. G., Zhang, X., Huang, X., Wu, M., Gao, J., Lu, D., Ding, Z., & Hu, B. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3045718 · Cited by 153
Source localization of auditory evoked potentials after cochlear implantation
Debener, S., Hine, J. E., Bleeck, S., & Eyles, J. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2007.00610.x · Cited by 152
Tu, Y., Zhang, Z., Tan, A., Peng, W., Hung, Y. S., Moayedi, M., Iannetti, G. D., & Hu, L. (2015) · Human Brain Mapping · doi:10.1002/hbm.23048 · Cited by 150
“Trials contaminated by eye blinks and movements were corrected using an independent component analysis algorithm [Delorme and Makeig, 2004].”
MethodSelf-regulation of frontal-midline theta facilitates memory updating and mental set shifting
Enriquez-Geppert, S., Huster, R. J., Figge, C., & Herrmann, C. S. (2014) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2014.00420 · Cited by 124
“Afterwards, so-called event-related spectral perturbations (ERSPs) were calculated for each task that represent log-transformed changes of power in dB relative to the baseline (Delorme and Makeig, 2004).”
MethodVoss, J. L., Schendan, H. E., & Paller, K. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.012 · Cited by 146
“Topographic maps (2D and 3D) were created using EEGLAB (Delorme and Makeig, 2004).”
MethodHybrid fNIRS-EEG based classification of auditory and visual perception processes
Putze, F., Heßlinger, S., Tse, C., Huang, Y., Herff, C., Guan, C., & Schultz, T. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00373 · Cited by 154
“Frequencymodulated near-infrared light from laser diodes (690 nm or 830 nm, 110 MHz) was conducted to the participants head with 64 optical source fibers (32 for each wavelength), pairwise co-localized in light source bundles. A rigid custom-made headmount system (montage) was used to hold the source and detector fibe…”
MethodInfluentialMaturation of EEG power spectra in early adolescence: a longitudinal study
Cragg, L., Kovačević, N., McIntosh, A. R., Poulsen, C., Martinu, K., Leonard, G. T., & Paus, T. (2011) · Developmental Science · doi:10.1111/j.1467-7687.2010.01031.x · Cited by 164
Cahn, B. R., Delorme, A., & Polich, J. (2013) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nss060 · Cited by 122
Low-frequency cortical activity is a neuromodulatory target that tracks recovery after stroke
Ramanathan, D. S., Guo, L., Gulati, T., Davidson, G., Hishinuma, A. K., Won, S.-J., Knight, R. T., Chang, E. F., Swanson, R. A., & Ganguly, K. (2018) · Nature Medicine · doi:10.1038/s41591-018-0058-y · Cited by 140
High-pass filtering artifacts in multivariate classification of neural time series data
van Driel, J., Olivers, C. N. L., & Fahrenfort, J. J. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109080 · Cited by 150
A novel approach to predict subjective pain perception from single-trial laser-evoked potentials
Huang, G., Xiao, P., Hung, Y. S., Iannetti, G. D., Zhang, Z. G., & Hu, L. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.017 · Cited by 145
Yellin, D., Berkovich‐Ohana, A., & Malach, R. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.034 · Cited by 152
“Implementation of bandpass filters was adapted from EEGLab (Delorme and Makeig, 2004).”
Semantic priming modulates the N400, N300, and N400RP
Franklin, M. S., Dien, J., Neely, J. H., Huber, E., & Waterson, L. D. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.01.012 · Cited by 155
The Cortical Development of Specialized Face Processing in Infancy
Guy, M. W., Zieber, N., & Richards, J. E. (2016) · Child Development · doi:10.1111/cdev.12543 · Cited by 144
Vourvopoulos, A., & Badia, S. B. I. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0173-2 · Cited by 160
Neural Correlates of Semantic Prediction and Resolution in Sentence Processing
Grisoni, L., Miller, T. M., & Pulvermüller, F. (2017) · Journal of Neuroscience · doi:10.1523/jneurosci.2800-16.2017 · Cited by 154
“A component was considered to be artifactual when its topography showed peak activity only over the horizontal or vertical eye electrodes and when it showed a smoothly decreasing power spectrum (which is typical for eye movement artifacts (Delorme and Makeig, 2004).”
BackgroundMovahed, R. A., Jahromi, G. P., Shahyad, S., & Meftahi, G. H. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109209 · Cited by 153
MICROSTATELAB: The EEGLAB Toolbox for Resting-State Microstate Analysis
Kalburgi, S. N., Kleinert, T., Aryan, D., Nash, K. A., Schiller, B., & Koenig, T. W. (2023) · Brain Topography · doi:10.1007/s10548-023-01003-5 · Cited by 154
Unconscious errors enhance prefrontal-occipital oscillatory synchrony
Cohen, M. X. (2009) · Frontiers in Human Neuroscience · doi:10.3389/neuro.09.054.2009 · Cited by 132
Active suppression of distractors that match the contents of visual working memory
Sawaki, R., & Luck, S. J. (2011) · Visual Cognition · doi:10.1080/13506285.2011.603709 · Cited by 158
May, L. E., Glaros, A., Yeh, H.-W., Clapp, J. F., & Gustafson, K. M. (2010) · Early Human Development · doi:10.1016/j.earlhumdev.2010.03.002 · Cited by 140
Slow oscillation-spindle coupling predicts enhanced memory formation from childhood to adolescence
Hahn, M. A., Heib, D., Schabus, M., Hoedlmoser, K., & Helfrich, R. F. (2020) · eLife · doi:10.7554/elife.53730 · Cited by 140
“, 2011), EEGlab toolbox (Delorme and Makeig, 2004) and CircStat toolbox (Berens, 2009) as well as custom written code.”
MethodDeficits in high- (>60 Hz) gamma-band oscillations during visual processing in schizophrenia
Grützner, C., Wibral, M., Sun, L., Rivolta, D., Singer, W., Maurer, K., & Uhlhaas, P. J. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00088 · Cited by 140
“This analysis approach was used to distinguish transient oscillatory activity associated with the onand off-responses from induced, non-phase locked oscillations based on the gradient of ITPC-values.”
MethodInfluentialSchevernels, H., Krebs, R. M., Santens, P., Woldorff, M. G., & Boehler, C. N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.09.039 · Cited by 129
Li, M., Liu, Y., Wu, Y., Liu, S., Jia, J., & Zhang, L. (2013) · International Journal of Neuroscience · doi:10.3109/00207454.2013.850082 · Cited by 150
Scheeringa, R., Mazaheri, A., Bojak, I., Norris, D. G., & Kleinschmidt, A. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.4697-10.2011 · Cited by 136
Hordacre, B. G., Moezzi, B., & Ridding, M. C. (2018) · Human Brain Mapping · doi:10.1002/hbm.24079 · Cited by 146
The representational dynamics of visual objects in rapid serial visual processing streams
Grootswagers, T., Robinson, A. K., & Carlson, T. A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.12.046 · Cited by 172
“Preprocessing was performed offline using EEGlab (Delorme & Makeig, 2004).”
MethodCalabrò, R. S., Naro, A., Filoni, S., Pullia, M., Billeri, L., Tomasello, P., Portaro, S., Lorenzo, G. D., Tomaino, C. M., & Bramanti, P. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0533-9 · Cited by 156
Norman, Y., Raccah, O., Liu, S., Parvizi, J., & Malach, R. (2021) · Neuron · doi:10.1016/j.neuron.2021.06.020 · Cited by 144
“QUANTIFICATION AND STATISTICAL ANALYSIS Peri-ripple spectrogram—Spectral decomposition of ripple events in hippocampal recording sites was done using a Morlet-wavelet time-frequency method, implemented in EEGLAB (Delorme and Makeig, 2004).”
BackgroundMethodInfluentialDelta- and theta-band cortical tracking and phase-amplitude coupling to sung speech by infants
Attaheri, A., Choisdealbha, Á. N., Liberto, G. M. D., Rocha, S., Brusini, P., Mead, N., Olawole‐Scott, H., Boutris, P., Gibbon, S., Williams, I., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118698 · Cited by 155
Cao, C., & Slobounov, S. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2027704 · Cited by 138
The ICLabel dataset of electroencephalographic (EEG) independent component (IC) features
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · Data in Brief · doi:10.1016/j.dib.2019.104101 · Cited by 154
“(cid:1) Equivalent current dipole (ECD) model fi ts were calculated using the dip fi t plug-in for EEGLAB.”
MethodInfluentialSelf-citationDecoding material-specific memory reprocessing during sleep in humans
Schönauer, M., Alizadeh, S., Jamalabadi, H., Abraham, A., Pawlizki, A., & Gais, S. (2017) · Nature Communications · doi:10.1038/ncomms15404 · Cited by 139
Graimann, B., & Pfurtscheller, G. (2006) · Progress in brain research · doi:10.1016/s0079-6123(06)59006-5 · Cited by 154
Steady state and induced auditory gamma deficits in schizophrenia
Krishnan, G. P., Hetrick, W. P., Brenner, C. A., Shekhar, A., Steffen, A. N., & O'Donnell, B. F. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.03.085 · Cited by 136
“The MP provides the measure of change in power during the stimuli compared to the s FFT. (b) Plot of the noise stimuli. baseline period and is equivalent to Event Related Spectral Perturbation (ERSP) (Delorme and Makeig, 2004).”
BackgroundMethodInfluentialUse-Dependent Cortical Processing from Fingertips in Touchscreen Phone Users
Gindrat, A., Chytiris, M., Balerna, M., Rouiller, E. M., & Ghosh, A. (2014) · Current Biology · doi:10.1016/j.cub.2014.11.026 · Cited by 149
“(EEGLAB, an open source MATLAB toolbox [44]).”
Herweg, N. A., Apitz, T., Leicht, G., Mulert, C., Fuentemilla, L., & Bunzeck, N. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.3629-15.2016 · Cited by 133
Fixation-related potentials in visual search: A combined EEG and eye tracking study
Kamienkowski, J. E., Ison, M. J., Quiroga, R. Q., & Sigman, M. (2012) · Journal of Vision · doi:10.1167/12.7.4 · Cited by 147
Emotion Analysis for Personality Inference from EEG Signals
Zhao, G., Ge, Y., Shen, B., Wei, X., & Wang, H. (2017) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2786207 · Cited by 149
“EEG signals were preprocessed in EEGLAB, which is an open source Matlab toolbox for physiological signal processing [52].”
MethodInfant-directed speech facilitates seven-month-old infants’ cortical tracking of speech
Kalashnikova, M., Peter, V., Liberto, G. M. D., Lalor, E. C., & Burnham, D. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-32150-6 · Cited by 153
Deep learning-based BCI for gait decoding from EEG with LSTM recurrent neural network
Tortora, S., Ghidoni, S., Chisari, C., Micera, S., & Artoni, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9842 · Cited by 134
Klug, M., & Kloosterman, N. A. (2022) · Human Brain Mapping · doi:10.1002/hbm.25832 · Cited by 148
“Examples are the CleanLine plugin of EEGLAB (Delorme and Makeig, 2004), which uses a frequency-domain regression to remove sinusoidal artifacts from the data, or TSPCA, which uses a provided reference signal (de Cheveigné and Simon, 2007).”
MethodYang, A. C., Wang, S., Lai, K., Tsai, C.-F., Yang, C., Hwang, J., Lo, M., Huang, N. E., Peng, C., & Fuh, J. (2013) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2013.07.022 · Cited by 152
Electrophysiological correlates of error correction
Fiehler, K., Ullsperger, M., & Von Cramon, D. Y. (2005) · Psychophysiology · doi:10.1111/j.1469-8986.2005.00265.x · Cited by 136
Genetic contributions to long-range temporal correlations in ongoing oscillations
Linkenkaer-Hansen, K., Smit, D. J. A., Barkil, A., van Beijsterveldt, T. E. M., Brussaard, A. B., Boomsma, D. I., van Ooyen, A., & de Geus, E. J. C. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3083-07.2007 · Cited by 138
Understanding the Benefits of Musical Training: Effects on Oscillatory Brain Activity
Trainor, L. J., Shahin, A. J., & Roberts, L. E. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2009.04589.x · Cited by 165
Lawhern, V. J., Hairston, W. D., McDowell, K., Westerfield, M., & Robbins, K. A. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.05.017 · Cited by 145
San Martín, R., Manes, F., Hurtado, E., Isla, P., & Ibañez, A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.031 · Cited by 132
“The EEGLAB Matlab toolbox (Delorme and Makeig, 2004) and the T-BESP software (http://www.neuro.udp.cl/software) were used for EEG offline processing and analysis.”
MethodDissociable correlates of response conflict and error awareness in error-related brain activity
Hughes, G., & Yeung, N. (2011) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2010.11.036 · Cited by 135
Voineskos, A. N., Farzan, F., Barr, M. S., Lobaugh, N. J., Mulsant, B. H., Chen, R. E., Fitzgerald, P. B., & Daskalakis, Z. J. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2010.06.021 · Cited by 150
Attention and Temporal Expectations Modulate Power, Not Phase, of Ongoing Alpha Oscillations
van Diepen, R. M., Cohen, M. X., Denys, D. A. J. P., & Mazaheri, A. (2015) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00803 · Cited by 143
Strauss, G. P., Kappenman, E. S., Culbreth, A. J., Catalano, L. T., Lee, B. G., & Gold, J. M. (2013) · Schizophrenia Bulletin · doi:10.1093/schbul/sbs186 · Cited by 131
Predictions drive neural representations of visual events ahead of incoming sensory information
Blom, T., Feuerriegel, D., Johnson, P. A., Bode, S., & Hogendoorn, H. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1917777117 · Cited by 148
Walker, H. C., Huang, H., Gonzalez, C. L., Bryant, J. E., Killen, J. F., Cutter, G., Knowlton, R. C., Montgomery, E. B., Guthrie, B. L., & Watts, R. L. (2012) · Movement Disorders · doi:10.1002/mds.25025 · Cited by 147
“Another potential contributor to R1 might be the summed orthodromic depolarization of presynaptic axon terminals in the cortex originating from the subthalamic region, before the generation of the excitatory postsynaptic potential.(26) This is less likely, however, because the peak at 1 ms occurs considerably sooner t…”
BackgroundMethodEEG Source Reconstruction Reveals Frontal-Parietal Dynamics of Spatial Conflict Processing
Cohen, M. X., & Ridderinkhof, K. R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057293 · Cited by 125
Payne, B. R., Lee, C., & Federmeier, K. D. (2015) · Psychophysiology · doi:10.1111/psyp.12515 · Cited by 132
“EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.”
Slagter, H. A., Prinssen, S., Reteig, L. C., & Mazaheri, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.09.058 · Cited by 151
“Preprocessing was done using the EEGLAB toolbox (Delorme and Makeig, 2004) operating in the MATLAB (Mathworks, Natick, MA) environment.”
EEG Responses to Visual Landmarks in Flying Pigeons
Vyssotski, A. L., Dell’Omo, G., Dell’Ariccia, G., Abramchuk, A. N., Serkov, A. N., Латанов, А. В., Loizzo, A., Wolfer, D. P., & Lipp, H. (2009) · Current Biology · doi:10.1016/j.cub.2009.05.070 · Cited by 137
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.