EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 701–800 of 1,310
The influence of mental fatigue and motivation on neural network dynamics; an EEG coherence study
Lorist, M. M., Bezdan, E., ten Caat, M., Span, M. M., Roerdink, J. B. T. M., & Maurits, N. M. (2009) · Brain Research · doi:10.1016/j.brainres.2009.03.015 · Cited by 159
“Subsequently, data was transferred to EEGLAB (Delorme and Makeig, 2004), running under MATLAB (The MathWorks Inc.).”
MethodMethodological aspects of EEG and body dynamics measurements during motion
Reis, P. M. R., Hebenstreit, F., Gabsteiger, F., von Tscharner, V., & Lochmann, M. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00156 · Cited by 159
“When exported to EEGLab, the segmentation time stamps can be of further use, provided synchronized measurements, brain and muscle activity can thus be directly linked to the corresponding movements.”
MethodInfluentialBaldwin, C. L., & Penaranda, B. N. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.047 · Cited by 159
“Datawas visualized and recorded using Acquire software (NeuroScan, Inc., Charlotte, NC) and further processed using MATLAB (R2009, The Mathworks, Natick, MA) and the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodBrain Dynamics in Predicting Driving Fatigue Using a Recurrent Self-Evolving Fuzzy Neural Network
Liu, Y.-T., Lin, Y.-Y., Wu, S.-L., Chuang, C.-H., & Lin, C.-T. (2016) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2015.2496330 · Cited by 159
Whitten, T. A., Hughes, A. M., Dickson, C. T., & Caplan, J. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.064 · Cited by 170
Prestimulus alpha power influences response criterion in a detection task
Limbach, K., & Corballis, P. M. (2016) · Psychophysiology · doi:10.1111/psyp.12666 · Cited by 167
Lenartowicz, A., Delorme, A., Walshaw, P. D., Cho, A. L., Bilder, R. M., McGough, J. J., McCracken, J. T., Makeig, S., & Loo, S. K. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.1765-13.2014 · Cited by 158
“Offline EEG processing and analyses were performed using custom MATLAB (Mathworks) scripts using functions from the EEGLAB environment (Delorme and Makeig, 2004; v 11.0.3b).”
InfluentialSelf-citationCharacterizing and minimizing the contribution of sensory inputs to TMS-evoked potentials
Biabani, M., Fornito, A., Mutanen, T. P., Morrow, J., & Rogasch, N. C. (2019) · Brain Stimulation · doi:10.1016/j.brs.2019.07.009 · Cited by 158
Vomero, M., Castagnola, E., Ciarpella, F., Maggiolini, E., Goshi, N., Zucchini, E., Carli, S., Fadiga, L., Kassegne, S., & Ricci, D. (2017) · Scientific Reports · doi:10.1038/srep40332 · Cited by 158
Correia, J. M., Jansma, B., Hausfeld, L., Kikkert, S., & Bonte, M. (2015) · Frontiers in Psychology · doi:10.3389/fpsyg.2015.00071 · Cited by 153
“These were conducted in EEGlab (Delorme and Makeig, 2004) and included: (1) an ERP analysis based on the average amplitude of signal change over time with respect to baseline (−1000 to 0 ms) and (2) an ERSP (event-related spectral perturbation) analysis based on averaged power changes of all words over frequency and t…”
BackgroundMethodInfluentialSchneider, T. R., Debener, S., Oostenveld, R., & Engel, A. K. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.033 · Cited by 173
Analysis and classification of speech imagery EEG for BCI
Wang, L., Zhang, X., Zhong, X., & Zhang, Y. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.07.011 · Cited by 170
Toward a proper estimation of phase–amplitude coupling in neural oscillations
Dvorak, D., & Fenton, A. A. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.01.002 · Cited by 149
Yang, J., Singh, H., Hines, E. L., Schlaghecken, F., Iliescu, D. D., Leeson, M. S., & Stocks, N. G. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.02.001 · Cited by 170
Landsness, E., Bruno, M.-A., Noirhomme, Q., Riedner, B., Gosseries, O., Schnakers, C., Massimini, M., Laureys, S., Tononi, G., & Boly, M. (2011) · Brain · doi:10.1093/brain/awr152 · Cited by 151
Target Speaker Detection with Concealed EEG Around the Ear
Mirkovic, B., Bleichner, M. G., Vos, M. D., & Debener, S. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00349 · Cited by 178
Howe, W. M., Gritton, H. J., Lusk, N. A., Roberts, E. A., Hetrick, V. L., Berke, J. D., & Sarter, M. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.2737-16.2017 · Cited by 146
“Time–frequency power spectrograms were obtained from the multitaper Fourier method implemented by the mtspecgramc function from the Chronux toolbox for MATLAB (Bokil et al., 2010).”
MethodKeil, A., Bernat, E. M., Cohen, M. X., Ding, M., Fabiani, M., Gratton, G., Kappenman, E. S., Maris, E., Mathewson, K. E., Ward, R. T., et al. (2022) · Psychophysiology · doi:10.1111/psyp.14052 · Cited by 173
Electrophysiological evidence for an early processing of human voices
Charest, I., Pernet, C. R., Rousselet, G. A., Quiñones, I., Latinus, M., Fillion-Bilodeau, S., Chartrand, J., & Belin, P. (2009) · BMC Neuroscience · doi:10.1186/1471-2202-10-127 · Cited by 170
“01 [27], under Matlab (The MathWorks Inc.”
BackgroundIsolating physiologic noise sources with independently determined spatial measures
Beall, E. B., & Lowe, M. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.004 · Cited by 172
Batterink, L., & Neville, H. (2011) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00013 · Cited by 122
Chung, S. W., Rogasch, N. C., Hoy, K. E., Sullivan, C. M., Cash, R. F. H., & Fitzgerald, P. B. (2018) · Human Brain Mapping · doi:10.1002/hbm.23882 · Cited by 150
“EEG data were analysed offline using EEGLAB (Delorme & Makeig, 2004), FieldTrip (Oostenveld, Fries, Maris, & Schoffelen, 2011), TESA (Rogasch et al., 2017) and custom scripts on Matlab platform (R2015b, The MathWorks, USA).”
MethodRegional Delta Waves In Human Rapid Eye Movement Sleep
Bernardi, G., Betta, M., Ricciardi, E., Pietrini, P., Tononi, G., & Siclari, F. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.2298-18.2019 · Cited by 156
“Potential ocular, muscular and electrocardiograph artifacts were removed using Independent Component Analysis (ICA) in EEGLAB (Delorme and Makeig, 2004).”
MethodEffects of time lag and frequency matching on phase-based connectivity
Cohen, M. X. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.09.005 · Cited by 170
Costa-Faidella, J., Baldeweg, T., Grimm, S., & Escera, C. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2599-11.2011 · Cited by 152
In search of biomarkers in psychiatry: EEG‐based measures of brain function
McLoughlin, G., Makeig, S., & Tsuang, M. T. (2014) · American Journal of Medical Genetics Part B: Neuropsychiatric Genetics · doi:10.1002/ajmg.b.32208 · Cited by 148
Self-citationSingle-trial time–frequency analysis of electrocortical signals: Baseline correction and beyond
Hu, L., Xiao, P., Zhang, Z. G., Mouraux, A., & Iannetti, G. D. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.09.055 · Cited by 161
Theta EEG oscillatory activity and auditory change detection
Fuentemilla, L., Marco‐Pallarés, J., Münte, T. F., & Grau, C. (2007) · Brain Research · doi:10.1016/j.brainres.2007.07.079 · Cited by 165
Edwards, E., Soltani, M., Kim, W., Dalal, S. S., Nagarajan, S. S., Berger, M. S., & Knight, R. T. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90954.2008 · Cited by 153
“The calculation of intertrial coherence (ITC) (Delorme and Makeig 2004; Edwards et al. 2005; Makeig et al. 2002) uses the complex numbers of the AS.”
MethodInfluentialTargeted transcranial direct current stimulation for rehabilitation after stroke
Dmochowski, J., Datta, A., Huang, Y., Richardson, J. D., Bikson, M., Fridriksson, J., & Parra, L. C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.049 · Cited by 162
Reduced mind wandering in experienced meditators and associated EEG correlates
Brandmeyer, T., & Delorme, A. (2016) · Experimental Brain Research · doi:10.1007/s00221-016-4811-5 · Cited by 170
Al-Shargie, F., Tang, T. B., & Kiguchi, M. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002583 · Cited by 147
Temporal cascade of frontal, motor and muscle processes underlying human action-stopping
Jana, S., Hannah, R., Muralidharan, V., & Aron, A. R. (2020) · eLife · doi:10.7554/elife.50371 · Cited by 158
Neurocomputational mechanisms of prior-informed perceptual decision-making in humans
Kelly, S. P., Corbett, E. A., & O’Connell, R. G. (2020) · Nature Human Behaviour · doi:10.1038/s41562-020-00967-9 · Cited by 165
Hamm, J. P., Gilmore, C. S., Picchetti, N. A. M., Sponheim, S. R., & Clementz, B. A. (2011) · Biological Psychiatry · doi:10.1016/j.biopsych.2010.11.021 · Cited by 149
EEG correlates of fatigue during administration of a neuropsychological test battery
Barwick, F., Arnett, P., & Slobounov, S. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.06.027 · Cited by 136
Goudarzi, M. M., Michels, L., Weisz, N., & Jeanmonod, D. (2010) · BMC Neuroscience · doi:10.1186/1471-2202-11-40 · Cited by 165
“edu/eeglab[45]), and custom scripts.”
On cross-frequency phase-phase coupling between theta and gamma oscillations in the hippocampus
Scheffer-Teixeira, R., & Tort, A. B. L. (2016) · eLife · doi:10.7554/elife.20515 · Cited by 161
Automated EEG artifact elimination by applying machine learning algorithms to ICA-based features
Radüntz, T., Scouten, J., Hochmuth, O., & Meffert, B. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa69d1 · Cited by 155
Automated Classification and Removal of EEG Artifacts With SVM and Wavelet-ICA
Sai, C. Y., Mokhtar, N. B., Arof, H., Cumming, P. D., & Iwahashi, M. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2723420 · Cited by 161
Comparison between Concentration and Immersion Based on EEG Analysis
Lim, S., Yeo, M., & Yoon, G. (2019) · Sensors · doi:10.3390/s19071669 · Cited by 155
Electrocortical Evidence for Impaired Affective Picture Processing after Long-Term Immobilization
Brauns, K., Friedl-Werner, A., Gunga, H., Maggioni, M. A., Dinges, D. F., & Stahn, A. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-52555-1 · Cited by 156
In vivo correlation between axon diameter and conduction velocity in the human brain
Horowitz, A., Barazany, D., Tavor, I., Bernstein, M., Yovel, G., & Assaf, Y. (2014) · Brain Structure and Function · doi:10.1007/s00429-014-0871-0 · Cited by 170
First-Pass Selectivity for Semantic Categories in Human Anteroventral Temporal Lobe
Chan, A. M., Baker, J. M., Eskandar, E., Schomer, D., Ulbert, I., Marinkovic, K., Cash, S. S., & Halgren, E. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.3122-11.2011 · Cited by 153
Cavanagh, J. F. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.007 · Cited by 160
Decoding word and category-specific spatiotemporal representations from MEG and EEG
Chan, A. M., Halgren, E., Marinković, K., & Cash, S. S. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.073 · Cited by 173
“These preprocessing steps were performed within MATLAB, using the EEGLAB 6.03b (Delorme and Makeig, 2004) and FieldTrip toolboxes (ver.”
MethodRegularity Extraction and Application in Dynamic Auditory Stimulus Sequences
Bendixen, A., Roeber, U., & Schröger, E. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.10.1664 · Cited by 146
Manoach, D. S., Thakkar, K. N., Stroynowski, E., Ely, A., McKinley, S. K., Wamsley, E., Djonlagic, I., Vangel, M. G., Goff, D. C., & Stickgold, R. (2010) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2009.06.011 · Cited by 152
“Further analyses were conducted using MATLAB and the EEG- LAB signal processing toolbox (MathWorks, Natick MA) (Delorme and Makeig, 2004).”
MethodEmotion classification using minimal EEG channels and frequency bands
Jatupaiboon, N., Pan-ngum, S., & Israsena, P. (2013) · International Joint Conference on Computer Science and Software Engineering · doi:10.1109/jcsse.2013.6567313 · Cited by 174
Chennu, S., O’Connor, S., Adapa, R., Menon, D. K., & Bekinschtein, T. A. (2016) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1004669 · Cited by 150
Compensatory Neural Activity in Response to Cognitive Fatigue
Wang, C., Trongnetrpunya, A., Samuel, I. B. H., Ding, M., & Kluger, B. M. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.3652-15.2016 · Cited by 137
on behalf of the CAN-BIND Investigator Team, Lam, R. W., Milev, R., Rotzinger, S., Andreazza, A. C., Blier, P., Brenner, C., Daskalakis, Z. J., Dharsee, M., Downar, J., et al. (2016) · BMC Psychiatry · doi:10.1186/s12888-016-0785-x · Cited by 148
Coordination of cortical and thalamic activity during non-REM sleep in humans
Mak-McCully, R. A., Rolland, M., Sargsyan, A., Gonzalez, C., Magnin, M., Chauvel, P., Rey, M., Bastuji, H., & Halgren, E. (2017) · Nature Communications · doi:10.1038/ncomms15499 · Cited by 151
ERP and behavioural evidence for direct suppression of unwanted memories
Bergström, Z. M., de Fockert, J. W., & Richardson‐Klavehn, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.051 · Cited by 162
“Acquired data were analysed using EEGLAB 6.0 (Delorme and Makeig, 2004; Swartz Center for Computational Neurosciences, La Jolla, CA; http://sccn.ucsd.edu/eeglab), an open source toolbox for EEG analysis in MATLAB (MathWorks, Inc, Natick, MA).”
InfluentialRoger, C., Bénar, C. G., Vidal, F., Hasbroucq, T., & Burle, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.005 · Cited by 153
“ICA computations were performed with the runica() function (as implemented in the EEGLAB software, Delorme and Makeig, 2004) which is derived from the Infomax ICA algorithm (Bell and Sejnowski, 1995).”
MethodMeasurement of Cognitive Load in HCI Systems Using EEG Power Spectrum: An Experimental Study
Kumar, N., & Kumar, J. (2016) · Procedia Computer Science · doi:10.1016/j.procs.2016.04.068 · Cited by 153
Pourtois, G., Spinelli, L., Seeck, M., & Vuilleumier, P. O. (2010) · Cognitive Affective & Behavioral Neuroscience · doi:10.3758/cabn.10.1.83 · Cited by 166
Krouchev, N. I., Kalaska, J. F., & Drew, T. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00241.2006 · Cited by 172
EEG alpha distinguishes between cuneal and precuneal activation in working memory
Michels, L., Goudarzi, M. M., Jeanmonod, D., & Sarnthein, J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.048 · Cited by 162
SanMiguel, I., Widmann, A., Bendixen, A., Trujillo-Barreto, N., & Schröger, E. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.5821-12.2013 · Cited by 141
Characteristics of Waveform Shape in Parkinson’s Disease Detected with Scalp Electroencephalography
Jackson, N., Cole, S. R., Voytek, B., & Swann, N. C. (2019) · eNeuro · doi:10.1523/eneuro.0151-19.2019 · Cited by 166
Predicting task-general mind-wandering with EEG
Jin, C. Y., Borst, J. P., & van Vugt, M. K. (2019) · Cognitive Affective & Behavioral Neuroscience · doi:10.3758/s13415-019-00707-1 · Cited by 167
Fields, E. C., & Kuperberg, G. R. (2019) · Psychophysiology · doi:10.1111/psyp.13468 · Cited by 171
Glick, H., & Sharma, A. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00093 · Cited by 170
Transfer learning for motor imagery based brain–computer interfaces: A tutorial
Wu, D., Jiang, X., & Peng, R. (2022) · Neural Networks · doi:10.1016/j.neunet.2022.06.008 · Cited by 182
A Respiration-Coupled Rhythm in the Rat Hippocampus Independent of Theta and Slow Oscillations
Lockmann, A. L. V., Laplagne, D. A., Leão, R. N., & Tort, A. B. L. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.3452-15.2016 · Cited by 152
Ahn, S., Mellin, J. M., Alagapan, S., Alexander, M. L., Gilmore, J. H., Jarskog, L. F., & Frӧhlich, F. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.056 · Cited by 161
Collins, A. G. E., & Frank, M. J. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1720963115 · Cited by 146
Mobile EEG identifies the re-allocation of attention during real-world activity
Ladouce, S., Donaldson, D. I., Dudchenko, P. A., & Ietswaart, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-51996-y · Cited by 159
Sun, L., Grutzner, C., Bolte, S., Wibral, M., Tozman, T., Schlitt, S., Poustka, F., Singer, W., Freitag, C. M., & Uhlhaas, P. J. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.1073-12.2012 · Cited by 151
Correa, N. M., Eichele, T., Adalı, T., Li, Y.-O., & Calhoun, V. D. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.062 · Cited by 151
Sun, Y., Farzan, F., Mulsant, B. H., Rajji, T. K., Fitzgerald, P. B., Barr, M. S., Downar, J., Wong, W., Blumberger, D. M., & Daskalakis, Z. J. (2016) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2015.3097 · Cited by 140
Cavanagh, J. F., Bismark, A. W., Frank, M. J., & Allen, J. J. B. (2019) · Computational Psychiatry · doi:10.1162/cpsy_a_00024 · Cited by 170
Is EEG Suitable for Marketing Research? A Systematic Review
Bazzani, A., Ravaioli, S., Trieste, L., Faraguna, U., & Turchetti, G. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594566 · Cited by 164
“After the data collection, EEG data require a pre-processing phase, which is rather homogeneous across the studies we reviewed, as far as the adoption of analysis toolboxes (Delorme and Makeig, 2004).”
MethodResting-state cortical connectivity predicts motor skill acquisition
Wu, J., Srinivasan, R., Kaur, A., & Cramer, S. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.026 · Cited by 150
“Next, EEG data underwent an Infomax ICA decomposition (EEGLAB (Delorme and Makeig, 2004)).”
Atypical intrinsic neural timescale in autism
Watanabe, T., Rees, G., & Masuda, N. (2019) · eLife · doi:10.7554/elife.42256 · Cited by 150
“Finally, to identify the source location of these preprocessed EEG signals, we conducted source reconstructions of the remaining ICA-components using DIPFIT2 function implemented in EEGLAB, and obtained MNI coordinates for each of the independent components.”
MethodInfluentialOwens, M., Koster, E. H. W., & Derakshan, N. (2013) · Psychophysiology · doi:10.1111/psyp.12010 · Cited by 138
Mercier, M. R., Foxe, J. J., Fiebelkorn, I. C., Butler, J. S., Schwartz, T. H., & Molholm, S. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.060 · Cited by 144
Myers, N. E., Walther, L., Wallis, G., Stokes, M. G., & Nobre, A. C. (2015) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00727 · Cited by 157
“Processing and EEG analyses were done offline, using the EEGLAB toolbox (Delorme & Makeig, 2004) and custom Matlab scripts for preprocessing.”
MethodDimitrakopoulos, G. Ν., Kakkos, I., Dai, Z., Lim, J., de Souza, J., Bezerianos, A., & Sun, Y. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2701002 · Cited by 159
“Preprocessing was performed with customized programs implemented in EEGLAB [35].”
MethodMulert, C., Seifert, C. L., Leicht, G., Kirsch, V., Ertl, M., Karch, S., Moosmann, M., Lutz, J., Möller, H., Hegerl, U., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.236 · Cited by 159
Age-dependent electroencephalogram (EEG) patterns during sevoflurane general anesthesia in infants
Cornelissen, L., Kim, S., Purdon, P. L., Brown, E. N., & Berde, C. B. (2015) · eLife · doi:10.7554/elife.06513 · Cited by 164
On the feasibility of side-channel attacks with brain-computer interfaces
Martinović, I., Davies, D. S., Frank, M., Perito, D., Ros, T., & Song, D. (2012) · Oxford University Research Archive (ORA) (University of Oxford) · Cited by 236
Milne, E., Scope, A., Pascalis, O., Buckley, D., & Makeig, S. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.07.017 · Cited by 148
Self-citationMahato, S., & Paul, S. (2020) · Journal of Medical Systems · doi:10.1007/s10916-019-1486-z · Cited by 148
Bulea, T. C., Kim, J., Damiano, D. L., Stanley, C. J., & Park, H. S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00247 · Cited by 157
“Using EEGLAB functions, feature vectors were reduced to 10 principal components and clustered across subjects using k-means (k = 7).”
BackgroundMethodInfluentialGeneralized EEG-Based Drowsiness Prediction System by Using a Self-Organizing Neural Fuzzy System
Lin, F.-C., Ko, L., Chuang, C., Su, T., & Lin, C. (2012) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2012.2185290 · Cited by 163
“5.03) developed by the Swartz Center for Computational Neruoscience, the University of California San Diego (UCSD) [27].”
MethodInfluentialA method for event-related phase/amplitude coupling
Voytek, B., D'Esposito, M., Crone, N., & Knight, R. T. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.023 · Cited by 142
“For ERSP and PAC figures (1, 3, 4, and 6) we corrected for multiple comparisons using a false discovery rate (FDR) method (fdr.m function in EEGLAB toolbox (Delorme and Makeig, 2004) in MATLAB).”
EEG Phase Patterns Reflect the Selectivity of Neural Firing
Ng, B. S. W., Logothetis, N. K., & Kayser, C. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs031 · Cited by 144
“EEG data were analyzed in Matlab using tools from the EEGLAB Matlab toolbox (Delorme and Makeig 2004).”
MethodSingle-trial classification of EEG in a visual object task using ICA and machine learning
Stewart, A. X., Nuthmann, A., & Sanguinetti, G. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.02.014 · Cited by 154
Characterization of EEG signals revealing covert cognition in the injured brain
Curley, W. H., Forgacs, P. B., Voss, H. U., Conte, M. M., & Schiff, N. D. (2018) · Brain · doi:10.1093/brain/awy070 · Cited by 156
“We performed all data processing offline in MATLAB (The Mathworks, Natick, MA) using a combination of EEGLAB, the Chronux toolbox, and in-house software (Delorme and Makeig, 2004; Bokil et al., 2010; Goldfine et al., 2011).”
MethodWeissman, B., & Tanner, D. (2018) · PLoS ONE · doi:10.1371/journal.pone.0201727 · Cited by 165
Bispectrum-Based Channel Selection for Motor Imagery Based Brain-Computer Interfacing
Jin, J., Liu, C., Daly, I. P., Miao, Y., Li, S., Wang, X., & Cichocki, A. S. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3020975 · Cited by 154
“According to the average IS, we plot the topography for all participants from DS1 and DS2 using MATLAB 2019a with the EEGLAB toolbox [39].”
MethodExploring Convolutional Neural Network Architectures for EEG Feature Extraction
Rakhmatulin, I., Dao, M.-S., Nassibi, A., & Mandic, D. P. (2024) · Sensors · doi:10.3390/s24030877 · Cited by 163
A Collaborative Brain-Computer Interface for Improving Human Performance
Wang, Y., & Jung, T.-P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020422 · Cited by 147
“We used independent component analysis (ICA) as an unsupervised spatial filtering technique to remove artifacts arising from eye and muscle movements. For each subject, all trials were band-pass filtered (1–30 Hz), concatenated, and then decomposed using the EEGLAB toolbox”
Huber, R., Määttä, S., Esser, S. K., Sarasso, S., Ferrarelli, F., Watson, A., Ferreri, F., Peterson, M. J., & Tononi, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.1636-08.2008 · Cited by 147
An automated pipeline for constructing personalized virtual brains from multimodal neuroimaging data
Schirner, M., Rothmeier, S., Jirsa, V., McIntosh, A. R., & Ritter, P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.055 · Cited by 162
Electrophysiological correlates of melodic processing in congenital amusia
Omigie, D., Pearce, M. T., Williamson, V. J., & Stewart, L. (2013) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2013.05.010 · Cited by 159
Dynamic Oscillatory Signatures of Central Neuropathic Pain in Spinal Cord Injury
Vučković, A., Hasan, M. A., Fraser, M., Conway, B. A., Nasseroleslami, B., & Allan, D. (2014) · Journal of Pain · doi:10.1016/j.jpain.2014.02.005 · Cited by 151
P300 speller BCI with a mobile EEG system: comparison to a traditional amplifier
Vos, M. D., Kroesen, M., Emkes, R., & Debener, S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036008 · Cited by 155
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.