EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 1,001–1,100 of 1,311
EEG-Deformer: A Dense Convolutional Transformer for Brain-Computer Interfaces
Ding, Y., Li, Y., Sun, H., Liu, R., Tong, C., Liu, C., Zhou, X., & Guan, C. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3504604 · Cited by 120
“6) SSVEPformer: The SSVEPformer is a Transformer-based method that comprises channel combination, SSVEP-former encoder, multilayer perceptron (MLP) head three core components that can extract spectrum information from the complex spectrum representation of EEG.”
MethodSpatial Filtering for EEG-Based Regression Problems in Brain–Computer Interface (BCI)
Wu, D., King, J.-T., Chuang, C.-H., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2017.2688423 · Cited by 116
EEG neural correlates of goal-directed movement intention
Pereira, J., Ofner, P., Schwarz, A., Sburlea, A. I., & Müller-Putz, G. R. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.030 · Cited by 116
“Offline processing of EEG and EOG data was performed using MATLAB R2012b (The MathWorks, Massachusetts, USA) with the BioSig toolbox (Schlögl and Brunner, 2008), the EEGLAB toolbox (Delorme and Makeig, 2004) and Brainstorm (Tadel et al., 2011).”
Hlinka, J., Alexakis, C., Diukova, A., Liddle, P. F., & Auer, D. P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.002 · Cited by 116
“Subsequently, the EEG data was downsampled to 256 Hz and imported to EEGlab (Delorme and Makeig, 2004) (www.sccn.ucsd.edu/eeglab), an open source toolbox running under the MATLAB environment.”
Dynamic corticostriatal activity biases social bonding in monogamous female prairie voles
Amadei, E. A., Johnson, Z. V., Jun Kwon, Y., Shpiner, A. C., Saravanan, V., Mays, W. D., Ryan, S. J., Walum, H., Rainnie, D. G., Young, L. J., et al. (2017) · Nature · doi:10.1038/nature22381 · Cited by 115
EEG mu component responses to viewing emotional faces
Moore, A., Gorodnitsky, I., & Pineda, J. (2012) · Behavioural Brain Research · doi:10.1016/j.bbr.2011.07.048 · Cited by 114
Online and Offline Domain Adaptation for Reducing BCI Calibration Effort
Wu, D. (2017) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2608931 · Cited by 114
Wagner, J., Wessel, J. R., Ghahremani, A., & Aron, A. R. (2018) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01183 · Cited by 112
Sleep spindles preferentially consolidate weakly encoded memories
Denis, D., Mylonas, D., Poskanzer, C., Bursal, V., Payne, J. D., & Stickgold, R. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.0818-20.2021 · Cited by 112
Acute biphasic effects of ayahuasca.
Schenberg, E. E., Alexandre, J. F. M., Filev, R., Cravo, A. M., Sato, J. R., Muthukumaraswamy, S. D., Yonamine, M., Waguespack, M., Lomnicka, I., Barker, S. A., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0137202 · Cited by 111
Statistical learning of speech regularities can occur outside the focus of attention
Batterink, L. J., & Paller, K. A. (2019) · Cortex · doi:10.1016/j.cortex.2019.01.013 · Cited by 111
Masia, V., Canal, P., Ricci, I., Vallauri, E. L., & Bambini, V. (2017) · Journal of Neurolinguistics · doi:10.1016/j.jneuroling.2016.11.005 · Cited by 110
Expected reward modulates encoding-related theta activity before an event
Gruber, M. J., Watrous, A. J., Ekstrom, A. D., Ranganath, C., & Otten, L. J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.064 · Cited by 108
“Blinks and eye movements were removed via independent component analysis (Bell and Sejnowski, 1995; Delorme and Makeig, 2004), which has been shown to be an effective way to eliminate such artifacts from EEG (e.g. Hoffmann and Falkenstein, 2008).”
MethodRighi, G., Tierney, A. L., Tager-Flusberg, H., & Nelson, C. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105176 · Cited by 105
“Functional connectivity in the gamma band (30–50 Hz) was quantified as linear coherence computed using the newcrossf function in EEGLAB.”
MethodCharacterizing the roles of alpha and theta oscillations in multisensory attention
Keller, A. S., Payne, L., & Sekuler, R. (2017) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2017.02.021 · Cited by 106
“EEG signals were preprocessed using the EEGLAB toolbox (Delorme and Makeig, 2004) for Matlab (Mathworks).”
Hill, A. T., Rogasch, N. C., Fitzgerald, P. B., & Hoy, K. E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.001 · Cited by 105
“All TMS-EEG data were analysed offline using custom scripts within the MATLAB platform (R2015b, The Mathworks, USA) using the EEGLAB (Delorme and Makeig, 2004) and Fieldtrip (Oostenveld et al., 2011) toolboxes.”
InfluentialPremotor cortex mediates perceptual performance
Callan, D., Callan, A., Gamez, M., Sato, M.-A., & Kawato, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.027 · Cited by 104
Kuzovkin, I., Vicente, R., Petton, M., Lachaux, J.-P., Baciu, M., Kahane, P., Rheims, S., Vidal, J. R., & Aru, J. (2018) · Communications Biology · doi:10.1038/s42003-018-0110-y · Cited by 104
Interoception primes emotional processing: multimodal evidence from neurodegeneration
Salamone, P. C., Legaz, A., Sedeño, L., Moguilner, S., Fraile-Vazquez, M., Campo, C. G., Fittipaldi, S., Yoris, A., Miranda, M., Birba, A., et al. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.2578-20.2021 · Cited by 103
“Low drifts were removed by linear trend corrections (Delorme and Makeig, 2004).”
Cortical origins of response time variability during rapid discrimination of visual objects
Gerson, A. D., Parra, L. C., & Sajda, P. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.06.026 · Cited by 103
Carlson, G. C., Talbot, K., Halene, T. B., Gandal, M. J., Kazi, H. A., Schlosser, L., Phung, Q. H., Gur, R. E., Arnold, S. E., & Siegel, S. J. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1109625108 · Cited by 103
Working memory-related frontal theta activity is decreased under acute stress
Gärtner, M., Rohde-Liebenau, L., Grimm, S., & Bajbouj, M. (2014) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2014.02.009 · Cited by 103
Škola, F., Tinková, S., & Liarokapis, F. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00329 · Cited by 102
“Cleaning was done using automatic subspace reconstruction (Chang et al., 2018, available as plugin for EEGLAB) and independent component analysis (ICA).”
MethodLuu, T. P., Nakagome, S., He, Y., & Contreras-Vidal, J. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-09187-0 · Cited by 101
McLoughlin, G., Palmer, J. A., Rijsdijk, F., & Makeig, S. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.07.020 · Cited by 100
“1b) (53) for MATLAB (R2012a; The Mathworks, Inc.”
Self-citationPredictive coding in autism spectrum disorder and attention deficit hyperactivity disorder
Gonzalez-Gadea, M. L., Chennu, S., Bekinschtein, T. A., Rattazzi, A., Beraudi, A., Tripicchio, P., Moyano, B., Soffita, Y., Steinberg, L., Adolfi, F., et al. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00543.2015 · Cited by 100
“ing steps were implemented using custom MATLAB scripts that used EEGLAB functionality (Delorme and Makeig 2004).”
Impact of multisession 40Hz tACS on hippocampal perfusion in patients with Alzheimer’s disease
Sprugnoli, G., Munsch, F., Cappon, D., Paciorek, R., Macone, J., Connor, A., El Fakhri, G., Salvador, R., Ruffini, G., Donohoe, K., et al. (2021) · Alzheimer's Research & Therapy · doi:10.1186/s13195-021-00922-4 · Cited by 99
“Data were preprocessed using EEGLAB 2020 [40], Fieldtrip toolbox for EEG/MEG-analysis (Donders Institute for Brain, Cognition and Behaviour, Radboud University, the Netherlands, see http:// field tript oolbox.”
MethodEmotional and non-emotional pathways to impulsive behavior and addiction.
Torres, A., Catena, A., Megías, A., Maldonado, A., Cándido, A., Verdejo-García, A., & Perales, J. C. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00043 · Cited by 99
“Offline signal preprocessing was done using EEGLAB software (Delorme and Makeig, 2004; freely available at http://sccn.ucsd.edu/eeglab).”
MethodState anxiety biases estimates of uncertainty and impairs reward learning in volatile environments
Hein, T. P., de Fockert, J., & Ruiz, M. H. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117424 · Cited by 99
Fear in dreams and in wakefulness: Evidence for day/night affective homeostasis
Sterpenich, V, Perogamvros, L., Tononi, G., & Schwartz, S. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/534099 · Cited by 99
Bernier, R., Aaronson, B., & McPartland, J. (2013) · Brain and Cognition · doi:10.1016/j.bandc.2013.02.008 · Cited by 98
A scoping review on the use of consumer-grade EEG devices for research
Sabio, J., Williams, N. S., McArthur, G. M., & Badcock, N. A. (2024) · PLOS ONE · doi:10.1371/journal.pone.0291186 · Cited by 98
Statistical feature extraction for artifact removal from concurrent fMRI-EEG recordings
Liu, Z., de Zwart, J. A., van Gelderen, P., Kuo, L.-W., & Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.042 · Cited by 97
Closed-loop digital meditation improves sustained attention in young adults
Ziegler, D. A., Simon, A. J., Gallen, C. L., Skinner, S., Janowich, J. R., Volponi, J. J., Rolle, C. E., Mishra, J., Kornfield, J., Anguera, J. A., et al. (2019) · Nature Human Behaviour · doi:10.1038/s41562-019-0611-9 · Cited by 97
Error awareness as evidence accumulation: effects of speed-accuracy trade-off on error signaling
Steinhauser, M., & Yeung, N. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00240 · Cited by 96
“01 (Delorme and Makeig, 2004) and custom routines written in MatLab 7.0.4 (The Mathworks, Natick, MA).”
MethodInfluentialSun, L., Castellanos, N., Grützner, C., Koethe, D., Rivolta, D., Wibral, M., Kranaster, L., Singer, W., Leweke, M. F., & Uhlhaas, P. J. (2013) · Schizophrenia Research · doi:10.1016/j.schres.2013.08.023 · Cited by 96
“Similar to the measures of spectral power, post-stimulus values were obtained by subtracting the mean ITPC-values during the −350 ms to −50 ms interval before stimulus onset.”
MethodInfluentialWan, L., Huang, H., Schwab, N., Tanner, J., Rajan, A., Lam, N. B., Zaborszky, L., Li, C. R., Price, C. C., & Ding, M. (2019) · Human Brain Mapping · doi:10.1002/hbm.24395 · Cited by 96
Progress toward openness, transparency, and reproducibility in cognitive neuroscience
Gilmore, R. O., Diaz, M. T., Wyble, B. A., & Yarkoni, T. (2017) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13325 · Cited by 95
Debnath, R., Tang, A., Zeanah, C. H., Nelson, C. A., & Fox, N. A. (2020) · Developmental Science · doi:10.1111/desc.12872 · Cited by 94
“EEG data were exported to a Matlab (Mathworks, Natick, MA) compatible format using Net Station software for offline processing with EEGLAB toolbox (Delorme and Makeig, 2004) and Matlab scripts.”
MethodDynamic imaging of ictal oscillations using non-invasive high-resolution EEG
Yang, L., Wilke, C., Brinkmann, B., Worrell, G. A., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.043 · Cited by 93
“…component analysis (ICA) was used to decompose each ictal EEG into a series of temporally independent and spatially fixed components as follows (Delorme and Makeig, 2004): (2) where N c is the number of ICs, Q i (ith column of the matrix Q n × NC )is the spatial map of the ith IC, T i (ith row…”
MethodThe self and its prolonged intrinsic neural timescale in schizophrenia
Northoff, G., Sandsten, K. E., Nordgaard, J., Kjaer, T. W., & Parnas, J. (2021) · Schizophrenia Bulletin · doi:10.1093/schbul/sbaa083 · Cited by 91
Catecholaminergic Regulation of Learning Rate in a Dynamic Environment
Jepma, M., Murphy, P. R., Nassar, M. R., Rangel-Gomez, M., Meeter, M., & Nieuwenhuis, S. (2016) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1005171 · Cited by 91
Bashivan, P., Bidelman, G. M., & Yeasin, M. (2014) · European Journal of Neuroscience · doi:10.1111/ejn.12749 · Cited by 91
“Electrode positions were registered to the MNI (Montreal Neurological Institute) brain and two symmetrical dipoles were fitted to each component using the boundary element head model (Delorme & Makeig, 2004) (v12.”
MethodInfluentialBatterink, L. J., Creery, J. D., & Paller, K. A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.3175-15.2016 · Cited by 89
“This approach was selected to optimize the tradeoff between temporal resolution at lower frequencies and frequency resolution at high frequencies (Delorme and Makeig, 2004).”
MethodInfluentialSanMiguel, I., Saupe, K., & Schröger, E. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00407 · Cited by 89
“EEG preprocessing was performed with EEGlab (Delorme and Makeig, 2004).”
MethodRapid extraction of auditory feature contingencies
Bendixen, A., Prinz, W., Horváth, J., Trujillo-Barreto, N. J., & Schröger, E. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.040 · Cited by 88
“SCDs were calculated and plotted with the aid of a plug-in for EEGlab (Delorme and Makeig, 2004) written by Andreas Widmann, University of Leipzig.”
MethodA postdecisional neural marker of confidence predicts information-seeking in decision-making
Desender, K., Murphy, P., Boldt, A., Verguts, T., & Yeung, N. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.2620-18.2019 · Cited by 88
“Bad (noisy) channels were replaced by an interpolated weighted average from surrounding electrodes using the EEGLAB toolbox (Delorme and Makeig, 2004) in MATLAB (The MathWorks).”
MethodChuang, C.-H., Chang, K.-Y., Huang, C.-S., & Jung, T.-P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119586 · Cited by 88
Deslandes, A. C., Moraes, H., Alves, H., Pompeu, F. A. M. S., Silveira, H., Mouta, R., Arcoverde, C., Ribeiro, P., Cagy, M., Piedade, R. A. M., et al. (2010) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2010007500041 · Cited by 88
Örün, Ö., & Akbulut, Y. (2019) · Computers in Human Behavior · doi:10.1016/j.chb.2018.11.027 · Cited by 87
Heartbeat and somatosensory perception
Al, E., Iliopoulos, F., Nikulin, V. V., & Villringer, A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118247 · Cited by 86
Touch inhibits subcortical and cortical nociceptive responses
Mancini, F., Beaumont, A.-L., Hu, L., Haggard, P., & Iannetti, G. D. D. (2015) · Pain · doi:10.1097/j.pain.0000000000000253 · Cited by 86
“The EEG data were preprocessed and analysed using Letswave (http://www.nocions.org/letswave/) and EEGLAB.11 Continuous EEG data were band-pass filtered from 1 to 30 Hz, segmented into epochs using a time window ranging from21 to12 seconds relative to the onset of the laser stimulus, and baseline corrected using the in…”
MethodInfluentialBoldt, A., Schiffer, A.-M., Waszak, F., & Yeung, N. (2019) · Scientific Reports · doi:10.1038/s41598-019-40681-9 · Cited by 86
Alpha Asymmetry in Infants at Risk for Autism Spectrum Disorders
Gabard-Durnam, L., Tierney, A. L., Vogel-Farley, V., Tager-Flusberg, H., & Nelson, C. A. (2015) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-013-1926-4 · Cited by 85
“, Natick, MA) using EEGLAB (Makeig and Delorme 2004) to visually inspect each 2-min EEG segment and select by hand the data free from movement artifact or ambient noise.”
Di Gregorio, F., Maier, M. E., & Steinhauser, M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.081 · Cited by 85
“0.1 (Delorme and Makeig, 2004) and custom routines in Matlab.”
InfluentialCognitive control ability mediates prediction costs in monolinguals and bilinguals
Zirnstein, M., van Hell, J. G., & Kroll, J. F. (2018) · Cognition · doi:10.1016/j.cognition.2018.03.001 · Cited by 84
Tang, M. F., Smout, C. A., Arabzadeh, E., & Mattingley, J. B. (2018) · eLife · doi:10.7554/elife.33123 · Cited by 83
“Electrical line noise was removed using clean_line.m, and clean_rawdata.m in EEGLAB (Delorme & Makeig, 2004) was used to remove bad channels (identified using Artifact Subspace Reconstruction), which were then interpolated from the neighbouring electrodes.”
Murphy, J. W., Foxe, J. J., Peters, J. B., & Molholm, S. (2014) · Autism Research · doi:10.1002/aur.1374 · Cited by 83
“See http://www.ru.nl/neuroimaging/ fieldtrip) as well as the EEGLAB toolbox [Delorme & Makeig, 2004] were applied for the analysis of the data.”
MethodAerobic exercise during pregnancy influences infant heart rate variability at one month of age
May, L. E., Scholtz, S. A., Suminski, R., & Gustafson, K. M. (2014) · Early Human Development · doi:10.1016/j.earlhumdev.2013.11.001 · Cited by 82
“Multivariate data were subjected to an Infomax independent component analysis algorithm implemented in EEGLAB [46].”
MethodMoral judgment modulates neural responses to the perception of other’s pain: an ERP study
Cui, F., Ma, N., & Luo, Y.-J. (2016) · Scientific Reports · doi:10.1038/srep20851 · Cited by 82
EEG fingerprinting: subject-specific signature based on the aperiodic component of power spectrum
Demuru, M., & Fraschini, M. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103748 · Cited by 82
Samaha, J., Boutonnet, B., Postle, B. R., & Lupyan, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-25093-5 · Cited by 80
Pal, D., Li, D., Dean, J. G., Brito, M. A., Liu, T., Fryzel, A. M., Hudetz, A. G., & Mashour, G. A. (2020) · The Journal of Neuroscience · doi:10.1523/jneurosci.1910-19.2019 · Cited by 80
“The absolute power for the slow EEG oscillations was assessed in the temporal domain by applying a bandpass filter (0.5–1 Hz) to the EEG data using the eegfiltnew function in the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodInfluentialSeifi Ala, T., Graversen, C., Wendt, D., Alickovic, E., Whitmer, W. M., & Lunner, T. (2020) · PLOS ONE · doi:10.1371/journal.pone.0235782 · Cited by 80
EEG Window Length Evaluation for the Detection of Alzheimer’s Disease over Different Brain Regions
Tzimourta, K. D., Giannakeas, N., Tzallas, A. T., Astrakas, L. G., Afrantou, T., Ioannidis, P., Grigoriadis, N., Angelidis, P., Tsalikakis, D. G., & Tsipouras, M. G. (2019) · Brain Sciences · doi:10.3390/brainsci9040081 · Cited by 79
Stylianou, M., Murphy, N., Peraza, L. R., Graziadio, S., Cromarty, R., Killen, A., O' Brien, J. T., Thomas, A. J., LeBeau, F. E. N., & Taylor, J.-P. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.013 · Cited by 79
Waytowich, N. R., Lawhern, V. J., Bohannon, A. W., Ball, K. R., & Lance, B. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00430 · Cited by 79
“Pre-processing was performed with EEGLAB (Delorme and Makeig, 2004).”
Detection of Early Stage Alzheimer’s Disease using EEG Relative Power with Deep Neural Network
Kim, D., & Kim, K. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512231 · Cited by 76
“We band-passed the EEG signals between 1 to 55 Hz using eegfilt function [16].”
MethodPierce, L. J., Thompson, B. L., Gharib, A., Schlueter, L., Reilly, E., Valdes, V., Roberts, S., Conroy, K., Levitt, P., & Nelson, C. A. (2019) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2019.0492 · Cited by 76
Panwar, S., Rad, P., Jung, T.-P., & Huang, Y. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3006180 · Cited by 76
Schema-conformant memories are preferentially consolidated during REM sleep
Durrant, S. J., Cairney, S. A., McDermott, C., & Lewis, P. A. (2015) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2015.02.011 · Cited by 75
“Sleep spindles were calculated in stages N2 and SWS by first bandpass filtering the signal at 11-15Hz using an FIR filter implemented in EEGLAB v12 (Delorme & Makeig, 2004) and then applying the automatic spindle detection algorithm of Ferrarelli et al (2007).”
Increased cortical reactivity to repeated tones at 8 months in infants with later ASD
Kolesnik, A., Begum Ali, J., Gliga, T., Guiraud, J., Charman, T., Johnson, M. H., Jones, E. J. H., & The BASIS Team (2019) · Translational Psychiatry · doi:10.1038/s41398-019-0393-x · Cited by 75
An electrophysiological signal that precisely tracks the emergence of error awareness
Murphy, P. R., Robertson, I. H., Allen, D., Hester, R., & O'Connell, R. G. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00065 · Cited by 94
“As a further constraint on the selection process, we used the DIPFIT 2 plugin for EEGLAB to localize the equivalent dipole locations of all IC scalp maps.”
MethodWu, D., Lawhern, V. J., Hairston, W. D., & Lance, B. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2544108 · Cited by 74
“We used EEGLAB [10] for EEG signal preprocessing and feature extraction.”
MethodThe right hemisphere fails to respond to temporal novelty in autism: evidence from an ERP study
Orekhova, E. V., Stroganova, T. A., Prokofiev, A. O., Nygren, G., Gillberg, C., & Elam, M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.12.034 · Cited by 74
Infraslow Electroencephalographic and Dynamic Resting State Network Activity
Grooms, J. K., Thompson, G. J., Pan, W.-J., Billings, J., Schumacher, E. H., Epstein, C. M., & Keilholz, S. D. (2017) · Brain Connectivity · doi:10.1089/brain.2017.0492 · Cited by 74
“EEG data were preprocessed through the MATLAB tool-box EEGLAB (Delorme and Makeig, 2004).”
InfluentialLearning From the Slips of Others: Neural Correlates of Trust in Automated Agents
de Visser, E. J., Beatty, P. J., Estepp, J. R., Kohn, S., Abubshait, A., Fedota, J. R., & McDonald, C. G. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00309 · Cited by 73
“All EEG data were sampled at Processing of EEG data was conducted using the EEGLAB (Delorme and Makeig, 2004) toolbox for the MATLAB programming environment (MathWorks, Natick, MA, United States).”
MethodScalp and Source Power Topography in Sleepwalking and Sleep Terrors: A High-Density EEG Study
Castelnovo, A., Riedner, B. A., Smith, R. F., Tononi, G., Boly, M., & Benca, R. M. (2016) · Sleep · doi:10.5665/sleep.6162 · Cited by 72
Advances in Electrophysiological Research
Kamarajan, C. (2015) · Alcohol Research: Current Reviews · doi:10.35946/arcr.v37.1.05 · Cited by 72
“Phase-locking factor (also called intertrial phase coherence) is a measure of phase consistency across trials from a single electrode or source (Delorme and Makeig 2004).”
BackgroundNoradrenergic Responsiveness Supports Selective Attention across the Adult Lifespan
Dahl, M. J., Mather, M., Sander, M. C., & Werkle-Bergner, M. (2020) · The Journal of Neuroscience · doi:10.1523/jneurosci.0398-19.2020 · Cited by 72
Papadaniil, C. D., Kosmidou, V. E., Tsolaki, A., Tsolaki, M., Kompatsiaris, I. (., & Hadjileontiadis, L. J. (2016) · Brain Research · doi:10.1016/j.brainres.2016.07.043 · Cited by 71
“The ERPs waveform analysis was conducted in Matlab 2013 365 (The Mathworks, Natick, USA), while the topographic distribution scalp maps were extracted using the EEGLab library [54].”
Wamain, Y., Gabrielli, F., & Coello, Y. (2016) · Cortex · doi:10.1016/j.cortex.2015.10.006 · Cited by 71
“For offline analysis, continuous EEG signal was filtered (1-100 Hz) and recalculated based on average reference using EEGLAB software (Delorme & Makeig, 2004), after periods with excessive noise artifacts were removed.”
Allostatic interoceptive overload in frontotemporal dementia
Birba, A., Santamaría-García, H., Prado, P., Cruzat, J., Ballesteros, A. S., Legaz, A., Fittipaldi, S., Duran-Aniotz, C., Slachevsky, A., Santibañez, R., et al. (2022) · Biological Psychiatry · doi:10.1016/j.biopsych.2022.02.955 · Cited by 70
Perogamvros, L., Baird, B., Seibold, M., Riedner, B., Boly, M., & Tononi, G. (2017) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01155 · Cited by 70
“Ocular, muscular, and electrocardiograph artifacts were removed with independent component analysis using EEGLAB routines (Delorme & Makeig, 2004).”
Tsolaki, A. C., Kosmidou, V., Kompatsiaris, I. (., Papadaniil, C., Hadjileontiadis, L., Adam, A., & Tsolaki, M. (2017) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2017.03.025 · Cited by 70
“The ERP waveform analysis was conducted in Matlab 2013 (The Mathworks, Natick, USA), with the topographic distribution scalp maps extracted using the EEGLab library (Delorme and Makeig, 2004).”
Jacquet, T., Lepers, R., Poulin-Charronnat, B., Bard, P., Pfister, P., & Pageaux, B. (2021) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2020.107701 · Cited by 70
Dynamic cortical connectivity during general anesthesia in healthy volunteers
Li, D., Vlisides, P. E., Kelz, M. B., Avidan, M. S., Mashour, G. A., & for the ReCCognition Study Group (2019) · Anesthesiology · doi:10.1097/aln.0000000000002656 · Cited by 69
N400 and P600 modulation in presupposition accommodation: The effect of different trigger types
Domaneschi, F., Canal, P., Masia, V., Lombardi Vallauri, E., & Bambini, V. (2018) · Journal of Neurolinguistics · doi:10.1016/j.jneuroling.2017.08.002 · Cited by 69
Dynamic Cortical Connectivity during General Anesthesia in Surgical Patients
Vlisides, P. E., Li, D., Zierau, M., Lapointe, A. P., Ip, K. I., McKinney, A. M., & Mashour, G. A. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002677 · Cited by 66
The relation of ventromedial prefrontal cortex activity and heart rate fluctuations at rest
Ziegler, G., Dahnke, R., Yeragani, V. K., & Bär, K. (2009) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2009.07008.x · Cited by 66
“The ECG signal was filtered with a special algorithm to remove high-frequency gradient noise [FMRIB plug-in for EEGLAB, provided by the University of Oxford Centre for Functional MRI of the Brain (Delorme & Makeig, 2004; Niazy et al., 2005)] within the MRI scanner.”
MethodTargeted memory reactivation during sleep elicits neural signals related to learning content
Wang, B., Antony, J. W., Lurie, S., Brooks, P. P., Paller, K. A., & Norman, K. A. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.2798-18.2019 · Cited by 66
“EEG data were processed using a combination of internal functions in EEGLAB (Delorme and Makeig, 2004) and custom-written scripts.”
MethodDistinct EEG signatures differentiate unconsciousness and disconnection during anaesthesia and sleep
Casey, C. P., Tanabe, S., Farahbakhsh, Z., Parker, M., Bo, A., White, M., Ballweg, T., Mcintosh, A., Filbey, W., Saalmann, Y., et al. (2022) · British Journal of Anaesthesia · doi:10.1016/j.bja.2022.01.010 · Cited by 66
Interregional alpha-band synchrony supports temporal cross-modal integration
van Driel, J., Knapen, T., van Es, D. M., & Cohen, M. X. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.022 · Cited by 66
“PCA-based independent components analysis was performed on the remaining epochs using the eeglab package (Delorme and Makeig, 2004) in Matlab (The MathWorks), by first reducing the data to 30 principal components, which were subsequently transformed into 30 independent components.”
MethodMagnetoencephalography Demonstrates Multiple Asynchronous Generators During Human Sleep Spindles
Dehghani, N., Cash, S. S., Rossetti, A. O., Chen, C. C., & Halgren, E. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00198.2010 · Cited by 66
Adolescent cognitive control, theta oscillations, and social observation
Buzzell, G. A., Barker, T. V., Troller-Renfree, S. V., Bernat, E. M., Bowers, M. E., Morales, S., Bowman, L. C., Henderson, H. A., Pine, D. S., & Fox, N. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.077 · Cited by 65
“, Eugene, OR); EEG analysis was performed using the EEGLAB toolbox (Delorme and Makeig 2004) and custom MATLAB scripts (The MathWorks, Natick, MA).”
MethodKielar, A., Panamsky, L., Links, K. A., & Meltzer, J. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.016 · Cited by 64
“The time–frequency analysis on the virtual channel signals was performed using EEGlab software (Delorme and Makeig, 2004; version 9.0.4.5) running in the Matlab 2010 (v 7.6) environment.”
MethodInfluentialLong-term working memory deficits after concussion: electrophysiological evidence
Ozen, L. J., Itier, R. J., Preston, F. F., & Fernandes, M. A. (2013) · Brain Injury · doi:10.3109/02699052.2013.804207 · Cited by 64
“The data were processed using the EEGLab toolbox [40] and ERPLAB toolbox (http://erpinfo.”
MethodAtypical Hemispheric Specialization for Faces in Infants at Risk for Autism Spectrum Disorder
Keehn, B., Vogel‐Farley, V., Tager‐Flusberg, H., & Nelson, C. A. (2015) · Autism Research · doi:10.1002/aur.1438 · Cited by 63
“Event-related changes in phase coherence were calculated using modified complex Morlet wavelet with the EEGLAB function newcrossf .”
Prediction of gait intention from pre-movement EEG signals: a feasibility study
Shafiul Hasan, S. M., Siddiquee, M. R., Atri, R., Ramon, R., Marquez, J. S., & Bai, O. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00675-5 · Cited by 63
Goldstone, A., Willoughby, A. R., de Zambotti, M., Franzen, P. L., Kwon, D., Pohl, K. M., Pfefferbaum, A., Sullivan, E. V., Müller-Oehring, E. M., Prouty, D. E., et al. (2018) · Brain Structure and Function · doi:10.1007/s00429-017-1509-9 · Cited by 63
“Sleep EEG data within non-rapid eye movement (NREM) sleep (N2 and N3 combined) were analyzed on selected electrodes (F3, F4, C3, C4, P3, and P4) using the EEGLAB toolbox (Delorme and Makeig 2004) for MATLAB (MathWorks, Natick, MA, USA), as previously described (Baker et al.”
Method
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.