EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 501–600 of 1,311
Axmacher, N., Cohen, M. X., Fell, J., Haupt, S., Dümpelmann, M., Elger, C. E., Schlaepfer, T. E., Lenartz, D., Sturm, V., & Ranganath, C. (2010) · Neuron · doi:10.1016/j.neuron.2010.02.006 · Cited by 183
“Data were analyzed using the EEGLAB package (Delorme and Makeig, 2004) running with MATLAB (The Mathworks, Natick, MA, USA) as well as with our own MATLAB programs.”
MethodKam, J. W. Y., Griffin, S., Shen, A., Patel, S., Hinrichs, H., Heinze, H.-J., Deouell, L. Y., & Knight, R. T. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.012 · Cited by 188
“Data decomposition was performed using the fastICA toolbox in EEGLAB, and artifactual components were manually detected based on component time course, topography and power spectral density.”
Ethridge, L. E., White, S. P., Mosconi, M. W., Wang, J., Byerly, M. J., & Sweeney, J. A. (2016) · Translational Psychiatry · doi:10.1038/tp.2016.48 · Cited by 188
Vakorin, V. A., Lippé, S., & McIntosh, A. R. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.3153-10.2011 · Cited by 171
“The first step of the analysis was performed with EEGLAB (Delorme and Makeig, 2004).”
MethodTracing the emergence of categorical speech perception in the human auditory system
Bidelman, G. M., Moreno, S., & Alain, C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.093 · Cited by 186
“Traces were then segmented (cortical ERP: −100–600 ms; brainstem ERP: −40–210 ms), baselined to the pre-stimulus interval, and subsequently averaged in the time domain to obtain ERPs for each condition (Delorme and Makeig, 2004).”
Beamforming in Noninvasive Brain–Computer Interfaces
Grosse-Wentrup, M., Liefhold, C., Gramann, K., & Buss, M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2009768 · Cited by 182
“Plotted with [6].”
Inter-brain synchrony in teams predicts collective performance
Reinero, D. A., Dikker, S., & Van Bavel, J. J. (2021) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsaa135 · Cited by 169
“Finally, they also utilized EEGLAB’s auto-channel rejection to note any channels that exceeded a kurtosis z-score threshold of 3 s.d.”
MethodMeltzer, J. A., Negishi, M., Mayes, L. C., & Constable, R. T. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.023 · Cited by 187
“Data were exported to EEGLAB software (Delorme and Makeig, 2004) for analysis.”
MethodEEG in the classroom: Synchronised neural recordings during video presentation
Poulsen, A. T., Kamronn, S., Dmochowski, J., Parra, L. C., & Hansen, L. K. (2017) · Scientific Reports · doi:10.1038/srep43916 · Cited by 187
“Eye artefacts were reduced with a conservative pre-processing procedure using independent component analysis (ICA), removing up to 3 of the 14 available components (Corrmap plug-in for EEGLAB 36,37 ).”
MethodContext effects on emotional and aesthetic evaluations of artworks and IAPS pictures
Gerger, G., Leder, H., & Kremer, A. (2014) · Acta Psychologica · doi:10.1016/j.actpsy.2014.06.008 · Cited by 174
Real and Fictive Outcomes Are Processed Differently but Converge on a Common Adaptive Mechanism
Fischer, A. G., & Ullsperger, M. (2013) · Neuron · doi:10.1016/j.neuron.2013.07.006 · Cited by 178
EEG feature comparison and classification of simple and compound limb motor imagery
Yi, W., Qiu, S., Qi, H., Zhang, L., Wan, B., & Ming, D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-106 · Cited by 183
“where n is the number of trails, and Fk(f, t)is the spectral estimation of kth trial at frequency f and time t [22].”
BackgroundA Precluding But Not Ensuring Role of Entrained Low-Frequency Oscillations for Auditory Perception
Ng, B. S. W., Schroeder, T., & Kayser, C. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.1877-12.2012 · Cited by 187
“EEG data was analyzed in MATLAB partly using functions from the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodA Riemannian Modification of Artifact Subspace Reconstruction for EEG Artifact Handling
Blum, S., Jacobsen, N. S. J., Bleichner, M. G., & Debener, S. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00141 · Cited by 186
“Matlab [Version 9.0 (2016a), The Mathworks Inc., Natick, MA, United States, RRID:SCR_001622 ] and EEGLAB (Version 13.6.5b, Delorme and Scott, 2004, RRID:SCR_007292 ) were used for all analyses.”
MethodInfluentialGuggisberg, A. G., Hess, C. W., & Mathis, J. (2007) · Sleep · doi:10.1093/sleep/30.6.755 · Cited by 186
EEG–fMRI integration for the study of human brain function
Jorge, J., van der Zwaag, W., & Figueiredo, P. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.114 · Cited by 167
“epoch extraction, electrode re-referencing and data re-sampling (Delorme and Makeig, 2004).”
Hämmerer, D., Li, S.-C., Müller, V., & Lindenberger, U. (2011) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2010.21475 · Cited by 181
“However, within each pair, one symbol had a higher probability of resulting in a gain than did the other symbol.”
BackgroundMethodSchättin, A., Arner, R., Gennaro, F., & de Bruin, E. D. (2016) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2016.00278 · Cited by 166
“Off-line signal processing was performed using a custom written script and both EEGLAB (Delorme and Makeig, 2004) and ERPLAB (Lopez-Calderon and Luck, 2014) toolboxes for MATLAB (Mathworks, Natick, MA).”
MethodChanges in EEG multiscale entropy and power‐law frequency scaling during the human sleep cycle
Miskovic, V., MacDonald, K. J., Rhodes, L. J., & Cote, K. A. (2019) · Human Brain Mapping · doi:10.1002/hbm.24393 · Cited by 186
Liu, Y., Bengson, J., Huang, H., Mangun, G. R., & Ding, M. (2014) · Cerebral Cortex · doi:10.1093/cercor/bhu204 · Cited by 166
“sampled to 250 Hz before being exported to EEGLAB (Delorme and Makeig 2004) for further analyses.”
InfluentialMemory failure predicted by attention lapsing and media multitasking
Madore, K. P., Khazenzon, A. M., Backes, C. W., Jiang, J., Uncapher, M. R., Norcia, A. M., & Wagner, A. D. (2020) · Nature · doi:10.1038/s41586-020-2870-z · Cited by 184
Task-specific signal transmission from prefrontal cortex in visual selective attention
Morishima, Y., Akaishi, R., Yamada, Y., Okuda, J., Toma, K., & Sakai, K. (2009) · Nature Neuroscience · doi:10.1038/nn.2237 · Cited by 184
The auditory steady-state response (ASSR)
O'Donnell, B. F., Vohs, J. L., Krishnan, G. P., Rass, O., Hetrick, W. P., & Morzorati, S. L. (2013) · Supplements to Clinical Neurophysiology · doi:10.1016/b978-0-7020-5307-8.00006-5 · Cited by 176
“The phase locking factor (PLF), or inter-trial phase coherence, is a measure of phase synchronization of EEG activity across trials at particular temporal intervals and frequencies (Delorme and Makeig, 2004).”
BackgroundSzczepanski, S. M., Crone, N. E., Kuperman, R. A., Auguste, K. I., Parvizi, J., & Knight, R. T. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001936 · Cited by 179
“The ECoG was filtered in each frequency range using a two-way least-square finite impulse response filter [65] to prevent phase distortion.”
MethodJebelli, H., Hwang, S., & Lee, S. (2018) · Journal of Computing in Civil Engineering · doi:10.1061/(asce)cp.1943-5487.0000719 · Cited by 177
β-Bursts Reveal the Trial-to-Trial Dynamics of Movement Initiation and Cancellation
Wessel, J. R. (2020) · The Journal of Neuroscience · doi:10.1523/jneurosci.1887-19.2019 · Cited by 173
Hierarchical Organization of Gamma and Theta Oscillatory Dynamics in Schizophrenia
Kirihara, K., Rissling, A. J., Swerdlow, N. R., Braff, D. L., & Light, G. A. (2012) · Biological Psychiatry · doi:10.1016/j.biopsych.2012.01.016 · Cited by 183
Beta- and gamma-range human lower limb corticomuscular coherence
Gwin, J. T., & Ferris, D. P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00258 · Cited by 183
“EEG was pre-processed in the same manner as (Gwin and Ferris, 2012) using Matlab (The Mathworks, Natick, MA) scripts based on EEGLAB, an open source environment for processing electrophysiological data (Delorme and Makeig, 2004).”
MethodArtoni, F., Fanciullacci, C., Bertolucci, F., Panarese, A., Makeig, S., Micera, S., & Chisari, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.013 · Cited by 183
“Data were analyzed using Matlab (Mathworks Natick, MA, USA) scripts based on the EEGLAB toolbox (Delorme and Makeig, 2004); EEG signals were decomposed into maximally-independent processes via extended-infomax Independent Component Analysis (ICA) (Makeig et al., 1996).”
BackgroundMethodInfluentialSelf-citationManifold Embedded Knowledge Transfer for Brain-Computer Interfaces
Zhang, W., & Wu, D. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2985996 · Cited by 183
“EEG Data Preprocessing EEG signals from all datasets were preprocessed using the EEGLAB toolbox [34].”
MethodTakamiya, A., Hirano, J., Yamagata, B., Takei, S., Kishimoto, T., & Mimura, M. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00001 · Cited by 183
“Then the EEG signal was decomposed into independent components (ICs) by Infomax IC analysis (Bell and Sejnowski, 1995), using the EEGLAB runica command.”
MethodBidelman, G. M., Weiss, M. W., Moreno, S., & Alain, C. (2014) · European Journal of Neuroscience · doi:10.1111/ejn.12627 · Cited by 181
“Traces were segmented (cortical ERP: 100 to 600 ms; brainstem ERPs: 40 to 210 ms), baselined to the respective pre-stimulus period, and subsequently averaged in the time domain to obtain ERPs for each condition (EEGLAB; Delorme & Makeig, 2004).”
MethodFrom ERPs to MVPA Using the Amsterdam Decoding and Modeling Toolbox (ADAM)
Fahrenfort, J. J., van Driel, J., van Gaal, S., & Olivers, C. N. L. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00368 · Cited by 176
“Further, when running first level (single subject) analyses it depends on a recent version of EEGLAB (Delorme and Makeig, 2004) ( ≥ 13, older versions might or might not work) and a recent install of Fieldtrip to perform time-frequency analysis prior to decoding (Oostenveld et al., 2011) ( ≥ 2015,…”
InfluentialClassifying phonological categories in imagined and articulated speech
Zhao, S., & Rudzicz, F. (2015) · 2015 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2015.7178118 · Cited by 182
“[14] Arnaud Delorme and Scott Makeig, “EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis,” Journal of Neuroscience Methods, vol. 134, no. 1, pp. 9–21, 2004.”
MethodInfluentialNonlinear connectivity by Granger causality
Marinazzo, D., Liao, W., Chen, H., & Stramaglia, S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.099 · Cited by 182
“We considered the human EEG from a visual task contained in the EEGLAB package (Delorme and Makeig, 2004).”
High thalamocortical theta coherence in patients with neurogenic pain
Sarnthein, J., & Jeanmonod, D. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.019 · Cited by 174
“The data were analyzed offline in the Matlab (The Mathworks, Natick, MA, USA) environment using EEGLAB (http://sccn.ucsd. edu/eeglab, Delorme and Makeig, 2004) and custom programming on the basis of standard mathematical and signal analysis functions.”
MethodPain Suppresses Spontaneous Brain Rhythms
Ploner, M., Gross, J., Timmermann, L., Pollok, B., & Schnitzler, A. (2006) · Cerebral Cortex · doi:10.1093/cercor/bhj001 · Cited by 178
The representation and processing of identical cognates by late bilinguals: RT and ERP effects
Peeters, D., Dijkstra, T., & Grainger, J. (2013) · Journal of Memory and Language · doi:10.1016/j.jml.2012.12.003 · Cited by 167
“Epochs from 100 ms prestimulus onset to 900 ms post-stimulus onset were selected using EEGLAB software (Delorme & Makeig, 2004).”
MethodSiclari, F., Bernardi, G., Riedner, B. A., LaRocque, J. J., Benca, R. M., & Tononi, G. (2014) · Sleep · doi:10.5665/sleep.4070 · Cited by 181
Mahmood, M., Mzurikwao, D., Kim, Y.-S., Lee, Y., Mishra, S., Herbert, R., Duarte, A., Ang, C. S., & Yeo, W.-H. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0091-7 · Cited by 181
Rao, V. R., Sellers, K. K., Wallace, D. L., Lee, M. B., Bijanzadeh, M., Sani, O. G., Yang, Y., Shanechi, M. M., Dawes, H. E., & Chang, E. F. (2018) · Current Biology · doi:10.1016/j.cub.2018.10.026 · Cited by 181
Prefrontal cortex and basal ganglia contributions to visual working memory
Voytek, B., & Knight, R. T. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1007277107 · Cited by 181
Using mu rhythm desynchronization to measure mirror neuron activity in infants
Nyström, P., Ljunghammar, T., Rosander, K., & von Hofsten, C. (2011) · Developmental Science · doi:10.1111/j.1467-7687.2010.00979.x · Cited by 181
An auditory oddball brain–computer interface for binary choices
Halder, S., Rea, M., Andreoni, R., Nijboer, F., Hammer, E. M., Kleih, S. C., Birbaumer, N., & Kübler, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.087 · Cited by 181
“The data were low-pass filtered at 20 Hz using two-way leastsquares finite impulse response (FIR) filtering with a function from the EEGLAB toolbox (Delorme and Makeig, 2004).”
Automated quantification of neuronal networks and single-cell calcium dynamics using calcium imaging
Patel, T. P., Man, K., Firestein, B. L., & Meaney, D. F. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.020 · Cited by 181
“Publicly availble tools have already had a clear benefit in the analysis of MRI, EEG, and electrophysiology data by offering research groups ccess to advanced routines and algorithms that go beyond the kills and expertise of an individual group (Cox, 1996; Cui et al., 008; Delorme and Makeig, 2004; Duann et al., 2002;…”
BackgroundCohen, M. X., & van Gaal, S. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs069 · Cited by 171
“Independent components analysis was computed using eeglab software (Delorme and Makeig 2004), and components containing blink/oculomotor artifacts or other artifacts that could be clearly distinguished from brain-driven EEG signals were subtracted from the data.”
MethodSleep deprivation leads to a loss of functional connectivity in frontal brain regions
Verweij, I. M., Romeijn, N., Smit, D. J., Piantoni, G., Van Someren, E. J., & van der Werf, Y. D. (2014) · BMC Neuroscience · doi:10.1186/1471-2202-15-88 · Cited by 180
“Off-line EEG analysis was done using EEGLAB (v2008b) [34] and Fieldtrip [35] in MatLab 7.”
MethodDehais, F., Duprès, A., Blum, S., Drougard, N., Scannella, S., Roy, R. N., & Lotte, F. (2019) · Sensors · doi:10.3390/s19061324 · Cited by 180
“The main drawback of reducing the number of electrodes is that it prevents from the use of efficient signal processing techniques such as independent component analysis (ICA) to identify artifactual components [39].”
MethodMacdonald, J. S. P., Mathan, S., & Yeung, N. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00082 · Cited by 180
“The research was conducted in accordance with the American Psychological Association’s standards for ethical treatment of participants and with the approval of the University of Oxford’s institutional review board. stIMulI and procEdurE The experiments were created and run with the Psychophysics Toolbox version 3 (Bra…”
MethodInfluentialKaneshiro, B., Perreau Guimaraes, M., Kim, H.-S., Norcia, A. M., & Suppes, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135697 · Cited by 180
“Ocular artifacts were removed from each participant’s EEG record using the extended Infomax ICA algorithm [50, 51] as implemented in the Matlab EEGLAB toolbox [52].”
MethodZich, C., Debener, S., Kranczioch, C., Bleichner, M. G., Gutberlet, I., & De Vos, M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.020 · Cited by 180
“4b (Delorme and Makeig, 2004).”
Longitudinal EEG power in the first postnatal year differentiates autism outcomes
Gabard-Durnam, L. J., Wilkinson, C., Kapur, K., Tager-Flusberg, H., Levin, A. R., & Nelson, C. A. (2019) · Nature Communications · doi:10.1038/s41467-019-12202-9 · Cited by 179
Time course and robustness of ERP object and face differences
Rousselet, G. A., Husk, J. S., Bennett, P. J., & Sekuler, A. B. (2008) · Journal of Vision · doi:10.1167/8.12.3 · Cited by 175
Neural indicators of perceptual variability of pain across species
Hu, L., & Iannetti, G. D. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812499116 · Cited by 174
“Trials contaminated by eye blinks and movements were corrected using an independent component analysis algorithm (runica) (42).”
InfluentialHu, L., Mouraux, A., Hu, Y., & Iannetti, G. D. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.010 · Cited by 178
“EEG data were imported and processed using EEGLAB (Delorme and Makeig, 2004), an open source toolbox running under the MATLAB environment.”
MethodAlpha-Band Activity Reveals Spontaneous Representations of Spatial Position in Visual Working Memory
Foster, J. J., Bsales, E. M., Jaffe, R. J., & Awh, E. (2017) · Current Biology · doi:10.1016/j.cub.2017.09.031 · Cited by 178
Ehinger, B. V., & Dimigen, O. (2019) · PeerJ · doi:10.7717/peerj.7838 · Cited by 178
“…fully documented, can employ regularization, can model both linear and non-linear effects using spline regression, and is compatible with EEGLAB ( Delorme & Makeig, 2004 ) a widely used toolbox to preprocess electrophysiological data that offers importers for many other biometric data formats,…”
Oxytocin enhances inter-brain synchrony during social coordination in male adults
Mu, Y., Guo, C., & Han, S. (2016) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsw106 · Cited by 177
“Here, to acquire better temporal and frequency resolution, we used slowly ascending NCWs which provide better temporal resolution at low frequencies and better frequency resolution at high frequencies, similar to the previous studies(Delorme and Makeig, 2004).”
ResultWessel, J. R., & Aron, A. R. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.3456-13.2013 · Cited by 177
“ICA and dipole fitting (DIPFIT 2.2) were performed using functions from the EEGLAB toolbox (Version 9; Delorme and Makeig, 2004).”
MethodInfluentialEthridge, L. E., White, S. P., Mosconi, M. W., Wang, J., Pedapati, E. V., Erickson, C. A., Byerly, M. J., & Sweeney, J. A. (2017) · Molecular Autism · doi:10.1186/s13229-017-0140-1 · Cited by 166
“Eye movement, cardiac, and muscle movement artifacts were removed blind to participant group using independent components analysis (ICA; Infomax) implemented in EEGLAB 11 [28] in Matlab (The Mathworks, Natick, MA).”
MethodWang, J., Ethridge, L. E., Mosconi, M. W., White, S. P., Binder, D. K., Pedapati, E. V., Erickson, C. A., Byerly, M. J., & Sweeney, J. A. (2017) · Journal of Neurodevelopmental Disorders · doi:10.1186/s11689-017-9191-z · Cited by 176
“Raw EEG data were filtered and transformed to an average reference using the EEGLAB toolbox [31].”
MethodHuman Microsaccade-Related Visual Brain Responses
Dimigen, O., Valsecchi, M., Sommer, W., & Kliegl, R. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.0911-09.2009 · Cited by 176
“4c– e) using the erpimage function of the EEGLAB toolbox (Delorme and Makeig, 2004) for MATLAB (The MathWorks).”
MethodKlados, M. A., Papadelis, C., Braun, C., & Bamidis, P. D. (2011) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.02.001 · Cited by 176
Cross-Modal Re-Organization in Adults with Early Stage Hearing Loss
Campbell, J., & Sharma, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090594 · Cited by 166
“EEGLAB was chosen specifically for preliminary source localization analysis in order to utilize the ICA algorithm that provides for optimal cortical source localization, and to perform ICA on concatenated EEG sweeps [36,37,42].”
MethodToscano, J. C., McMurray, B., Dennhardt, J., & Luck, S. J. (2010) · Psychological Science · doi:10.1177/0956797610384142 · Cited by 160
“Data were processed using the EEGLAB toolbox for MATLAB (Delorme & Makeig, 2004).”
MethodNeural Decoding of Imagined Speech and Visual Imagery as Intuitive Paradigms for BCI Communication
Lee, S.-H., Lee, M., & Lee, S.-W. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3040289 · Cited by 166
“EEG data were pre-processed using the EEGLAB and BBCI toolbox [18], [19].”
MethodAltered Cortical Ensembles in Mouse Models of Schizophrenia
Hamm, J. P., Peterka, D. S., Gogos, J. A., & Yuste, R. (2017) · Neuron · doi:10.1016/j.neuron.2017.03.019 · Cited by 175
Slow Oscillations in the Mouse Hippocampus Entrained by Nasal Respiration
Yanovsky, Y., Ciatipis, M., Draguhn, A., Tort, A. B. L., & Brankačk, J. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.5287-13.2014 · Cited by 175
“m routine, which in turn applies the filter forward and then again backwards to ensure that phase delays introduced by the filter are nullified (Delorme and Makeig, 2004).”
BackgroundMiskovic, V., Ma, X., Chou, C.-A., Fan, M., Owens, M., Sayama, H., & Gibb, B. E. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.013 · Cited by 175
Spectral characteristics of resting state networks
Niazy, R. K., Xie, J., Miller, K., Beckmann, C. F., & Smith, S. M. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53839-0.00017-x · Cited by 175
What makes an art expert? Emotion and evaluation in art appreciation
Leder, H., Gerger, G., Brieber, D., & Schwarz, N. (2014) · Cognition and Emotion · doi:10.1080/02699931.2013.870132 · Cited by 175
Cortical processes associated with continuous balance control as revealed by EEG spectral power
Hülsdünker, T., Mierau, A., Neeb, C., Kleinöder, H., & Strüder, H. K. (2015) · Neuroscience Letters · doi:10.1016/j.neulet.2015.02.049 · Cited by 168
Burle, B., Roger, C., Allain, S., Vidal, F., & Hasbroucq, T. (2008) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2008.20110 · Cited by 163
Local and Widespread Slow Waves in Stable NREM Sleep: Evidence for Distinct Regulation Mechanisms
Bernardi, G., Siclari, F., Handjaras, G., Riedner, B. A., & Tononi, G. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00248 · Cited by 167
Frontal EEG theta/beta ratio during mind wandering episodes
van Son, D., De Blasio, F. M., Fogarty, J. S., Angelidis, A., Barry, R. J., & Putman, P. (2019) · Biological Psychology · doi:10.1016/j.biopsycho.2018.11.003 · Cited by 165
The roles of alpha oscillation in working memory retention
Wianda, E., & Roß, B. (2019) · Brain and Behavior · doi:10.1002/brb3.1263 · Cited by 186
Do age-related differences in aperiodic neural activity explain differences in resting EEG alpha?
Merkin, A., Sghirripa, S., Graetz, L. J., Smith, A. E., Hordacre, B. G., Harris, R. J., Pitcher, J. B., Semmler, J. G., Rogasch, N. C., & Goldsworthy, M. R. (2022) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2022.09.003 · Cited by 183
ERP correlates of action effect prediction and visual sensory attenuation in voluntary action
Hughes, G., & Waszak, F. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.057 · Cited by 188
FORCe: Fully online and automated artifact removal for brain-computer interfacing
Daly, I., Scherer, R., Billinger, M., & Muller-Putz, G. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346621 · Cited by 174
“The implementation of the algorithm for the EEGLAB toolbox was used in this study [32].”
MethodFaugeras, F., Rohaut, B., Weiss, N., Bekinschtein, T., Galanaud, D., Puybasset, L., Bolgert, F., Sergent, C., Cohen, L., Dehaene, S., et al. (2012) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2011.12.015 · Cited by 174
“The current emergence of brain-computer interfaces allowing such analyses to be performed in real-time on a singletrial basis may well significantly increase the sensitivity of our test (Delorme & Makeig, 2004; Thulasidas, Guan, & Wu, 2006).”
BackgroundEEG-based measurement system for monitoring student engagement in learning 4.0
Apicella, A., Arpaia, P., Frosolone, M., Improta, G., Moccaldi, N., & Pollastro, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-09578-y · Cited by 174
“Independent Component Analysis (ICA) was used to filter out the artifacts from the EEG signals using the Runica module of the EEGLab tool 85 .”
BackgroundMethodDecoding Individual Finger Movements from One Hand Using Human EEG Signals
Liao, K., Xiao, R., Gonzalez, J., & Ding, L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085192 · Cited by 174
“EEG data were high-pass filtered at 0.3 Hz using an elliptic infinite impulse response (IIR) filter from the EEGLAB toolbox [48] with both forward and reverse filtering to avoid phase distortions.”
MethodInfluentialBhagat, N. A., Venkatakrishnan, A., Abibullaev, B., Artz, E. J., Yozbatiran, N., Blank, A. A., French, J., Karmonik, C., Grossman, R. G., O'Malley, M. K., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00122 · Cited by 174
“…of spatial average occurred earlier than −1.5 s (vertical black line) with respect to movement-onset, were rejected when training the classifier since these trials are most likely corrupted by artifacts. raster plots were created using EEGLAB's erpimage() function (Delorme and Makeig, 2004).”
MethodInfluentialBuiatti, M., PENA, M., & Dehaene‐Lambertz, G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.015 · Cited by 193
Badcock, N. A., Preece, K. A., de Wit, B., Glenn, K., Fieder, N., Thie, J., & McArthur, G. (2015) · PeerJ · doi:10.7717/peerj.907 · Cited by 159
“123 Insert Figures 1 and 2 about here 124 Offline EEG processing 125 Both Neuroscan and EPOC EEG recordings were processed in the same way using EEGLAB version 126 11.0.4.3b (Delorme & Makeig, 2004).”
MethodInfluentialRay, N. J., Brittain, J.-S., Holland, P., Joundi, R. A., Stein, J. F., Aziz, T. Z., & Jenkinson, N. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.035 · Cited by 161
“Data were imported into EEGLAB (Delorme and Makeig, 2004) filtered (between 6 Hz and 100 Hz) and aligned to triggers representing the presentation of task stimuli and subject responses.”
Cerebral peak alpha frequency predicts individual differences in pain sensitivity
Furman, A. J., Meeker, T. J., Rietschel, J. C., Yoo, S., Muthulingam, J., Prokhorenko, M., Keaser, M. L., Goodman, R. N., Mazaheri, A., & Seminowicz, D. A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.042 · Cited by 161
“For the primary set of analyses the preprocessing of EEG data was done using EEGLAB 13.6.5b 164 (Delorme and Makeig, 2004) using an approach similar to that used previously (Scheeringa et al., 2011a; Scheeringa et 165 al., 2011b).”
InfluentialIntegrated analysis of anatomical and electrophysiological human intracranial data
Stolk, A., Griffin, S., van der Meij, R., Dewar, C., Saez, I., Lin, J. J., Piantoni, G., Schoffelen, J.-M., Knight, R. T., & Oostenveld, R. (2018) · Nature Protocols · doi:10.1038/s41596-018-0009-6 · Cited by 180
“19 Using the command below, visualize the MRI along with the electrodes and their labels and examine whether they show the expected behavior. ft_plot_ortho(fsmri_acpc.anatomy, 'transform', fsmri_acpc.transform, 'style', 'intersect'); ft_plot_sens(elec_acpc_f, 'label', 'on', 'fontcolor', 'w'); ?”
BackgroundMethodHoldgraf, C., Appelhoff, S., Bickel, S., Bouchard, K., D’Ambrosio, S., David, O., Devinsky, O., Dichter, B., Flinker, A., Foster, B. L., et al. (2019) · Scientific Data · doi:10.1038/s41597-019-0105-7 · Cited by 165
Time–Frequency Analysis of Event-Related Potentials: A Brief Tutorial
Herrmann, C. S., Rach, S., Vosskuhl, J., & Strüber, D. (2014) · Brain Topography · doi:10.1007/s10548-013-0327-5 · Cited by 173
“A very instructive tutorial on the software package EEGLAB is available from Delorme and Makeig (2004).”
Stimulus-specific enhancement of fear extinction during slow-wave sleep
Hauner, K. K., Howard, J. D., Zelano, C., & Gottfried, J. A. (2013) · Nature Neuroscience · doi:10.1038/nn.3527 · Cited by 173
Validation of SOBI components from high-density EEG
Tang, A. C., Sutherland, M. T., & McKinney, C. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.11.027 · Cited by 173
“Q (Delorme and Makeig, 2004, p. 20).”
Iannetti, G. D., Zambreanu, L., & Tracey, I. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.115675 · Cited by 173
“Trial-to-trial consistency of the main N2–P2 vertex response was qualitatively assessed by sorting single-trial responses vertically in order of occurrence, with signal amplitude colour-coded and smoothed across trials using a 10-trial rectangular moving average (Delorme & Makeig, 2004).”
MethodDifferential maturation of brain signal complexity in the human auditory and visual system
Lippe, S. (2009) · Frontiers in Human Neuroscience · doi:10.3389/neuro.09.048.2009 · Cited by 154
Vourvopoulos, A., Jorge, C., Abreu, R., Figueiredo, P., Fernandes, J.-C., & Bermúdez i Badia, S. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00244 · Cited by 166
“For the offline analysis, EEG signals were processed in MATLAB R© (The MathWorks, Natick, MA, United States) with the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodGramann, K., Onton, J., Riccobon, D., Mueller, H. J., Bardins, S., & Makeig, S. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21369 · Cited by 172
“Significant changes ( p .001, uncorrected for multiple comparisons) in mean power from the mean spectral baseline for each component over the time course of tunnel passages were computed using bootstrap resampling (Delorme & Makeig, 2004).”
InfluentialSelf-citationYeom, S., Kim, H., & Hong, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108134 · Cited by 172
Kappel, S. L., Rank, M. L., Toft, H. O., Andersen, M., & Kidmose, P. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2835778 · Cited by 172
“All recordings were bandpass filtered with the EEGLAB FIR filter function “pop_eegfiltnew()” [23].”
MethodBishop, D. V. M., Hardiman, M. J., & Barry, J. G. (2011) · Developmental Science · doi:10.1111/j.1467-7687.2010.00990.x · Cited by 157
“Eyeblinks and other focal artefacts were detected using second-order blind identification (SOBI) independent component analysis (Tang, Sutherland & McKinney, 2005), implemented in EEGLAB software (Delorme & Makeig, 2004).”
MethodCortical route for facelike pattern processing in human newborns
Buiatti, M., Di Giorgio, E., Piazza, M., Polloni, C., Menna, G., Taddei, F., Baldo, E., & Vallortigara, G. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1812419116 · Cited by 160
“Delorme A, Makeig S (2004) EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.”
Method
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.