EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 1,101–1,200 of 1,311
Conejero, Á., Guerra, S., Abundis‐Gutiérrez, A., & Rueda, M. R. (2018) · Developmental Science · doi:10.1111/desc.12494 · Cited by 62
Consciousness and cortical responsiveness: a within-state study during non-rapid eye movement sleep
Nieminen, J. O., Gosseries, O., Massimini, M., Saad, E., Sheldon, A. D., Boly, M., Siclari, F., Postle, B. R., & Tononi, G. (2016) · Scientific Reports · doi:10.1038/srep30932 · Cited by 61
Paloyelis, Y., Krahé, C., Maltezos, S., Williams, S. C., Howard, M. A., & Fotopoulou, A. (2016) · Journal of Neuroendocrinology · doi:10.1111/jne.12347 · Cited by 61
Baker, F. C., Willoughby, A. R., Massimiliano, D. Z., Franzen, P. L., Prouty, D., Javitz, H., Hasler, B., Clark, D. B., & Colrain, I. M. (2016) · SLEEP · doi:10.5665/sleep.5978 · Cited by 61
Naro, A., Bramanti, P., Leo, A., Russo, M., & Calabrò, R. S. (2016) · Brain Topography · doi:10.1007/s10548-016-0489-z · Cited by 61
“Data were stored on a personal computer for offline analysis through a free license of the EEGLAB toolbox (Delorme and Makeig 2004).”
MethodCsukly, G., Stefanics, G., Komlósi, S., Czigler, I., & Czobor, P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0075444 · Cited by 60
“Built-in and self-developed functions as well as the freeware EEGLAB toolbox [33] in the Matlab (MathWorks, Natick, MA) development environment were used for subsequent off-line data analyses.”
MethodAlessa, F. M., Alhaag, M. H., Al-harkan, I. M., Ramadan, M. Z., & Alqahtani, F. M. (2023) · Sensors · doi:10.3390/s23187698 · Cited by 60
Dien, J., Brian, E. S., Molfese, D. L., & Gold, B. T. (2013) · Cortex · doi:10.1016/j.cortex.2013.03.008 · Cited by 59
Kogan, J. H., Gross, A. K., Featherstone, R. E., Shin, R., Chen, Q., Heusner, C. L., Adachi, M., Lin, A., Walton, N. M., Miyoshi, S., et al. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.3967-14.2015 · Cited by 59
“For each epoch, power was calculated by the EEGLAB MatLab toolbox using Morlet wavelets in 116 logarithmically spaced frequency bins between 4 and 120 Hz, with wavelet cycle numbers ranging from 2 to 10 (Delorme and Makeig, 2004).”
MethodWakefulness delta waves increase after cortical plasticity induction
Assenza, G., Pellegrino, G., Tombini, M., Di Pino, G., & Di Lazzaro, V. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.09.029 · Cited by 59
“Power spectral density (PSD) analysis for delta (1–4 Hz), theta (4–8), alpha (8–12), and beta (12–33) bands was performed employing the Matlab toolbox EEGLab (Delorme and Makeig, 2004).”
MethodLefebvre, A., Delorme, R., Delanoë, C., Amsellem, F., Beggiato, A., Germanaud, D., Bourgeron, T., Toro, R., & Dumas, G. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00662 · Cited by 58
Neurophysiologic markers of abnormal brain activity in schizophrenia
Rissling, A. J., Makeig, S., Braff, D. L., & Light, G. A. (2010) · Current Psychiatry Reports · doi:10.1007/s11920-010-0149-z · Cited by 58
Self-citationStuldreher, I. V., Thammasan, N., van Erp, J. B. F., & Brouwer, A.-M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba87d · Cited by 58
“The fast changing phasic and slowly varying tonic components of the signal were extracted using Continuous Decomposition Analysis as implemented in the Ledalab toolbox for MATLAB (Benedek and Kaernbach 2010).”
InfluentialA Feasibility Study for Validating Robot Actions Using EEG-Based Error-Related Potentials
Ehrlich, S. K., & Cheng, G. (2019) · International Journal of Social Robotics · doi:10.1007/s12369-018-0501-8 · Cited by 58
“All EEG data preprocessing was carried out in MATLAB ® , in part using functions provided by the EEGLAB toolbox [11].”
MethodCognitive and Neural Correlates of Loneliness and Wisdom during Emotional Bias
Grennan, G., Balasubramani, P. P., Alim, F., Zafar-Khan, M., Lee, E. E., Jeste, D. V., & Mishra, J. (2021) · Cerebral Cortex · doi:10.1093/cercor/bhab012 · Cited by 57
How Attention Changes in Response to Incentives
Sawaki, R., Luck, S. J., & Raymond, J. E. (2015) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00847 · Cited by 57
Alzheimer's disease patients classification through EEG signals processing
Fiscon, G., Weitschek, E., Felici, G., Bertolazzi, P., De Salvo, S., Bramanti, P., & De Cola, M. C. (2014) · 2014 IEEE Symposium on Computational Intelligence and Data Mining (CIDM) · doi:10.1109/cidm.2014.7008655 · Cited by 57
“, EEGlab [38] for MATLAB R ©) in order to perform a more effective EEG”
MethodYeung, M. K., Han, Y. M. Y., Sze, S. L., & Chan, A. S. (2016) · Neuropsychology · doi:10.1037/neu0000231 · Cited by 57
Vision of the body modulates processing in primary somatosensory cortex
Longo, M. R., Pernigo, S., & Haggard, P. (2011) · Neuroscience Letters · doi:10.1016/j.neulet.2010.12.007 · Cited by 57
How to become an expert: a new perspective on the role of sleep in the mastery of procedural skills
Fogel, S. M., Ray, L. B., Binnie, L., & Owen, A. M. (2015) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2015.10.004 · Cited by 55
“Power spectral analysis of movement artifact-free epochs of EEG scored as NREM2, SWS and REM sleep from all EEG derivations was conducted using Fast Fourier Transform (FFT) using the ''spectopo " EEGlab function that employs the ''pwelch " function from the Matlab Signal Processing Toolbox.”
Benefits of deep learning classification of continuous noninvasive brain–computer interface control
Stieger, J. R., Engel, S. A., Suma, D., & He, B. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0584 · Cited by 55
“Noisy channels, identified through visual inspection, were replaced by local weighted averages interpolated through spherical splines (Delorme and Makeig 2004, Ferree 2006).”
MethodGao, J., Fan, J., Wu, B. W., Halkias, G. T., Chau, M., Fung, P. C., Chang, C., Zhang, Z., Hung, Y.-S., & Sik, H. (2017) · Frontiers in Psychology · doi:10.3389/fpsyg.2016.02055 · Cited by 54
Cavanagh, J. F., Gründler, T. O. J., Frank, M. J., & Allen, J. J. B. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2010.03.031 · Cited by 54
Sniff and mimic–Intranasal oxytocin increases facial mimicry in a sample of men
Korb, S., Malsert, J., Strathearn, L., Vuilleumier, P., & Niedenthal, P. (2016) · Hormones and Behavior · doi:10.1016/j.yhbeh.2016.06.003 · Cited by 54
Visram, A. S., Innes-Brown, H., El-Deredy, W., & McKay, C. M. (2015) · Hearing Research · doi:10.1016/j.heares.2015.04.012 · Cited by 54
Signal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Cantiani, C., Ortiz-Mantilla, S., Riva, V., Piazza, C., Bettoni, R., Musacchia, G., Molteni, M., Marino, C., & Benasich, A. A. (2019) · NeuroImage: Clinical · doi:10.1016/j.nicl.2019.101778 · Cited by 54
“Data were exported to a MATLAB (Mathworks, Natick, MA) compatible format and processed using EEGLAB (Delorme and Makeig, 2004) and ERPLAB (Lopez-Calderon and Luck, 2014).”
MethodKwon, J., Shin, J., & Im, C.-H. (2020) · PLOS ONE · doi:10.1371/journal.pone.0230491 · Cited by 53
“com/bbci/bbci_public) were employed [22, 23].”
Midline frontal and occipito-temporal activity during error monitoring in dyadic motor interactions
Moreau, Q., Candidi, M., Era, V., Tieri, G., & Aglioti, S. M. (2020) · Cortex · doi:10.1016/j.cortex.2020.01.020 · Cited by 53
Tracking Real-Time Changes in Working Memory Updating and Gating with the Event-Based Eye-Blink Rate
Rac-Lubashevsky, R., Slagter, H. A., & Kessler, Y. (2017) · Scientific Reports · doi:10.1038/s41598-017-02942-3 · Cited by 52
Petit, G., Cebolla, A. M., Fattinger, S., Petieau, M., Summerer, L., Cheron, G., & Huber, R. (2019) · npj Microgravity · doi:10.1038/s41526-019-0069-0 · Cited by 52
Villena‐González, M., Moënne‐Loccoz, C., Lagos, R. A., Alliende, L. M., Billeke, P., Aboitiz, F., López, V., & Cosmelli, D. (2017) · Psychophysiology · doi:10.1111/psyp.12894 · Cited by 52
“A second-order infinite impulse response (IIR) Butterworth filter was used for band-pass filtering of continuous data, with a half amplitude cutoff frequency of 0.5 Hz and 30 Hz, using the EEGLAB toolbox (Delorme & Makeig, 2004).”
MethodInfluentialNeural Correlates of the Shamanic State of Consciousness
Huels, E. R., Kim, H., Lee, U., Bel-Bahar, T., Colmenero, A. V., Nelson, A., Blain-Moraes, S., Mashour, G. A., & Harris, R. E. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.610466 · Cited by 52
“EEG Analysis Using the MATLAB open-source toolbox EEGLab (Delorme and Makeig, 2004), data were visually inspected for artifact and preprocessed via resampling to 500 Hz as necessary, bandpass filtering between 1–45 Hz, and re-referencing to the global average.”
MethodInfants of mothers with higher physiological stress show alterations in brain function
Troller‐Renfree, S. V., Brito, N. H., Desai, P. M., Leon‐Santos, A. G., Wiltshire, C. A., Motton, S. N., Meyer, J. S., Isler, J., Fifer, W. P., & Noble, K. G. (2020) · Developmental Science · doi:10.1111/desc.12976 · Cited by 52
“Electroencephalography was analyzed using the EEGLAB toolbox (Delorme & Makeig, 2004), MATLAB scripts (The MathWorks), and the MADE pipeline (Debnath et al., 2020).”
MethodPerera, M. P. N., Mallawaarachchi, S., Bailey, N. W., Murphy, O. W., & Fitzgerald, P. B. (2022) · doi:10.1101/2022.10.03.510571 · Cited by 51
Brain-to-brain synchrony between students and teachers predicts learning outcomes
Davidesco, I., Laurent, E., Valk, H., West, T., Dikker, S., Milne, C., & Poeppel, D. (2019) · doi:10.1101/644047 · Cited by 50
Local targeted memory reactivation in human sleep
Bar, E., Marmelshtein, A., Arzi, A., Perl, O., Livne, E., Hizmi, E., Paz, R., Sobel, N., Dudai, Y., & Nir, Y. (2020) · Current Biology · doi:10.1016/j.cub.2020.01.091 · Cited by 50
Electrophysiological evidence for a general auditory prediction deficit in adults who stutter
Daliri, A., & Max, L. (2015) · Brain and Language · doi:10.1016/j.bandl.2015.08.008 · Cited by 50
“Data analysis Data analysis was completed using the EEGLAB toolbox (Delorme & Makeig, 2004) and custom-written MATLAB scripts (The MathWorks, Inc., Natick, MA).”
Alger, S. E., Kensinger, E. A., & Payne, J. D. (2018) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2018.03.030 · Cited by 50
Troller‐Renfree, S., Nelson, C. A., Zeanah, C. H., & Fox, N. A. (2016) · Journal of Child Psychology and Psychiatry · doi:10.1111/jcpp.12604 · Cited by 47
“The ICA components that correlated at .9 or above with the averaged blink topography and/or with the ERP PCAToolkit–supplied blink topography were removed.”
Rac-Lubashevsky, R., & Kessler, Y. (2018) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01326 · Cited by 47
Azzalini, D., Buot, A., Palminteri, S., & Tallon-Baudry, C. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.1932-20.2021 · Cited by 47
“ICA was computed on MEG data epoched6200ms around the R-peak of the ECG in data segments that were free of artifacts, blinks, and saccades .3°.”
MethodInfluential(2025) · doi:10.1109/jbhi.2023.3346205 · Cited by 47
“EEG signal preprocessing was performed using the MATLAB toolbox EEGLAB [29].”
Rebollo, I., & Tallon-Baudry, C. (2022) · The Journal of Neuroscience · doi:10.1523/jneurosci.1285-21.2021 · Cited by 46
“Heart rate variability preprocessing In order to computer the power and ratio of Heart rate variability, we first removed the MRI gradient artefact from the ECG data using the FMRIB plug-in (Iannetti et al., 2005; Niazy, Beckmann, Iannetti, Brady, & Smith, 2005, version 1.21) for EEGLAB (Delorme & Makeig, 2004, versio…”
MethodInfluentialVishne, G., Gerber, E. M., Knight, R. T., & Deouell, L. Y. (2023) · Cell Reports · doi:10.1016/j.celrep.2023.112752 · Cited by 46
“80,81 To estimate the HFA time course we band-pass filtered the whole signal in eight 10 Hz sub-ranges between 70 and 150 Hz (EEGLAB’s FIR Hamming window, function ‘pop_eegfiltnew’ 68 ).”
Interplay of brain structure and function in neonatal congenital heart disease
Birca, A., Vakorin, V. A., Porayette, P., Madathil, S., Chau, V., Seed, M., Doesburg, S. M., Blaser, S., Nita, D. A., Sharma, R., et al. (2016) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.336 · Cited by 46
Sokka, L., Leinikka, M., Korpela, J., Henelius, A., Ahonen, L., Alain, C., Alho, K., & Huotilainen, M. (2016) · Biological Psychology · doi:10.1016/j.biopsycho.2016.02.010 · Cited by 46
Baranauskas, M., Grabauskaitė, A., & Griškova-Bulanova, I. (2017) · Physiology & Behavior · doi:10.1016/j.physbeh.2017.07.032 · Cited by 46
“3 and 30 Hz using EEGLAB for MATLAB [47].”
MethodInfluentialDoes stroke volume influence heartbeat evoked responses?
Buot, A., Azzalini, D., Chaumon, M., & Tallon-Baudry, C. (2021) · Biological Psychology · doi:10.1016/j.biopsycho.2021.108165 · Cited by 46
Cantiani, C., Piazza, C., Mornati, G., Molteni, M., & Riva, V. (2019) · Infant Behavior and Development · doi:10.1016/j.infbeh.2019.101384 · Cited by 46
Reward feedback processing in children and adolescents: medial frontal theta oscillations
Crowley, M. J., van Noordt, S. J. R., Wu, J., Hommer, R. E., South, M., Fearon, R. M. P., & Mayes, L. C. (2014) · Brain and Cognition · doi:10.1016/j.bandc.2013.11.011 · Cited by 45
“Our data processing pipeline involved computing ERSP and ITC values in EEGLab, using algorithms for implementing a time × frequency spectrogram (Delorme & Makeig, 2004).”
MethodBaird, B., Castelnovo, A., Riedner, B. A., Lutz, A., Ferrarelli, F., Boly, M., Davidson, R. J., & Tononi, G. (2018) · eneuro · doi:10.1523/eneuro.0293-18.2018 · Cited by 45
“…phasic epochs, with phasic REM sleep visually classified by a trained technician as any epochs that contained REMs and/or myoclonic twitches. hd-EEG processing hd-EEG data analysis was conducted with MATLAB (Mathworks Inc.) using the EEGLAB v13 toolbox (Delorme and Makeig, 2004) and custom scripts.”
MethodDementia ConnEEGtome: towards multicentric harmonization of EEG connectivity in neurodegeneration
Prado, P., Birba, A., Cruzat, J., Santamaría-García, H., Parra, M., Moguilner, S., Tagliazucchi, E., & Ibáñez, A. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.12.008 · Cited by 43
“The list of powerful tools is lengthy and includes EEGLab (Delorme and Makeig, 2004), Cartool (Cartool Software FBMLab), Brainstorm (Tadel et al., 2011), MNE-Python (Gramfort et al., 2013) and BioSig, among others.”
MethodJones, R., & Bhattacharya, J. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.11.008 · Cited by 43
“All data pre-processing and visualisation were carried out using the MATLAB® based toolbox, EEGLAB (Delorme and Makeig, 2004).”
Eckart, C., Fuentemilla, L., Bauch, E. M., & Bunzeck, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.011 · Cited by 43
“Blinks and eye movements were removed via independent component analysis (Delorme and Makeig, 2004).”
Do meditators have higher awareness of their intentions to act?
Jo, H.-G., Hinterberger, T., Wittmann, M., & Schmidt, S. (2015) · Cortex · doi:10.1016/j.cortex.2014.12.015 · Cited by 43
Spectral and spatial shifts of post-ictal slow waves in temporal lobe seizures
Yang, L., Worrell, G. A., Nelson, C., Brinkmann, B., & He, B. (2012) · Brain · doi:10.1093/brain/aws221 · Cited by 42
Confusional arousals during non-rapid eye movement sleep: evidence from intracerebral recordings
Flamand, M., Boudet, S., Lopes, R., Vignal, J.-P., Reyns, N., Charley-Monaca, C., Peter-Derex, L., & Szurhaj, W. (2018) · Sleep · doi:10.1093/sleep/zsy139 · Cited by 41
Slow wave sleep in naps supports episodic memories in early childhood
Lokhandwala, S., & Spencer, R. M. C. (2021) · Developmental Science · doi:10.1111/desc.13035 · Cited by 41
“Delta amplitude envelopes were extracted from the filtered EEG data using the Hilbert transformation, and SWA was calculated as the average per-second magnitude of the artifact-free delta amplitude envelope during SWS. PSG analyses were performed in MATLAB using EEGLAB (Delorme & Makeig, 2004), ERPLAB (Lopez-Calderon…”
MethodLucid dreaming occurs in activated rapid eye movement sleep, not a mixture of sleep and wakefulness
Baird, B., Tononi, G., & LaBerge, S. (2022) · Sleep · doi:10.1093/sleep/zsab294 · Cited by 41
Torta, D. M., Liang, M., Valentini, E., Mouraux, A., & Iannetti, G. D. (2012) · Experimental Brain Research · doi:10.1007/s00221-012-3019-6 · Cited by 41
“EEG data were preprocessed and analyzed using Letswave (http://amouraux.webnode.com) (Mouraux and Iannetti 2008) and EEGLAB (Delorme and Makeig 2004).”
MethodPfabigan, D. M., Alexopoulos, J., Bauer, H., Lamm, C., & Sailer, U. (2011) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2011.00100 · Cited by 41
The association between suicidal behavior, attentional control, and frontal asymmetry.
Thompson, C., & Ong, E. L. C. (2018) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2018.00079 · Cited by 41
Biabani, M., Fornito, A., Coxon, J. P., Fulcher, B. D., & Rogasch, N. C. (2021) · The Journal of Physiology · doi:10.1113/jp280966 · Cited by 41
“EEG data were pre-processed based on the method described in [40, 41], performed by custom scripts written in MATLAB (R2016b, The Mathworks, USA) using the functions provided by EEGLAB [42] and TESA [40] toolboxes.”
MethodPupil size reveals arousal level fluctuations in human sleep
Carro-Domínguez, M., Huwiler, S., Oberlin, S., Oesch, T. L., Badii, G., Lüthi, A., Wenderoth, N., Meissner, S. N., & Lustenberger, C. (2025) · Nature Communications · doi:10.1038/s41467-025-57289-5 · Cited by 41
Wong, W., Noreika, V., Móró, L., Revonsuo, A., Windt, J., Valli, K., & Tsuchiya, N. (2020) · Neuroscience of Consciousness · doi:10.1093/nc/niaa006 · Cited by 40
“2012); some of the EEG data handling was facilitated by the EEGLAB toolbox in Matlab (Delorme and Makeig 2004).”
MethodDe Stefano, L. A., Schmitt, L. M., White, S. P., Mosconi, M. W., Sweeney, J. A., & Ethridge, L. E. (2019) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2019.00034 · Cited by 40
“Eye, cardiac, and muscle movement artifacts were removed using independent component analysis in EEGLAB 13 (Delorme and Makeig, 2004) for Matlab (The Mathworks, Natick, MA, United States).”
MethodNoradrenergic and Cholinergic Modulation of Belief Updating
Jepma, M., Brown, S. B. R. E., Murphy, P. R., Koelewijn, S. C., de Vries, B., van den Maagdenberg, A. M., & Nieuwenhuis, S. (2018) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01317 · Cited by 39
Effects of exercise on electroencephalographic mean frequency in depressed elderly subjects
Silveira, H., Deslandes, A. C., de Moraes, H., Mouta, R., Ribeiro, P., Piedade, R., & Laks, J. (2010) · Neuropsychobiology · doi:10.1159/000279304 · Cited by 39
“A trained physician who was blinded to all the other data did the visual inspection of the EEG data. He also excluded epochs contaminated by blinks, eye movements and movement-related artifacts from the analyses, based on a rejection criterion of ±100 μV on any channel. Moreover, independent component analysis from EE…”
Beatty, P. J., Buzzell, G. A., Roberts, D. M., & McDonald, C. G. (2020) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/s13415-020-00792-7 · Cited by 39
An intracranial EEG study of the neural dynamics of musical valence processing
Omigie, D., Dellacherie, D., Hasboun, D., George, N., Clement, S., Baulac, M., Adam, C., & Samson, S. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhu118 · Cited by 39
“Estimates of event-related (log) spectral perturbations (ERSPs) were computed using the newtimef function from the EEGLAB toolbox (Delorme and Makeig 2004).”
MethodIhara, A. S., Nakajima, K., Kake, A., Ishimaru, K., Osugi, K., & Naruse, Y. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.679191 · Cited by 40
Sleepers selectively suppress informative inputs during rapid eye movements
Koroma, M., Lacaux, C., Andrillon, T., Legendre, G., Léger, D., & Kouider, S. (2020) · Current Biology · doi:10.1016/j.cub.2020.04.047 · Cited by 37
Co-maturation of theta and low-beta rhythms during child development
Rodríguez-Martínez, E. I., Barriga-Paulino, C. I., Rojas-Benjumea, M. A., & Gómez, C. M. (2015) · Brain Topography · doi:10.1007/s10548-014-0369-3 · Cited by 36
Shenoy Handiru, V., Vinod, A. P., & Guan, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6baf · Cited by 36
“Artifact correction was done using independent component analysis (ICA) with the help of EEGLAB toolbox [37].”
MethodSteiner, G. Z., Yeung, A., Liu, J.-X., Camfield, D. A., Blasio, F. M. D., Pipingas, A., Scholey, A. B., Stough, C., & Chang, D. H. (2015) · BMC Complementary and Alternative Medicine · doi:10.1186/s12906-016-0989-0 · Cited by 36
“6b [42]).”
Lindström, R., Lepistö-Paisley, T., Makkonen, T., Reinvall, O., Nieminen-von Wendt, T., Alén, R., & Kujala, T. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.08.018 · Cited by 36
“The continuous EEG was processed with the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodChoi, J., Kwon, M., & Jun, S. C. (2020) · Sensors · doi:10.3390/s20102770 · Cited by 35
“If possible, depending on the study’s purpose, one may implement custom-made signal processing tools by introducing external libraries using a plugin such as EEGLab or Fieldtrip libraries [98,99].”
MethodP300 Speller Performance Predictor Based on RSVP Multi-feature
Won, K., Kwon, M., Jang, S., Ahn, M., & Jun, S. C. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00261 · Cited by 34
“Among the epochs extracted, data with an amplitude greater than 100 µ V or those exceeding the threshold (five times the standard deviation across trials) were rejected using the EEGLAB toolbox’s automatic removal features (Delorme et al., 2001; Delorme and Makeig, 2004).”
MethodAbnormal timing of slow wave synchronization processes in non-rapid eye movement sleep parasomnias
Cataldi, J., Stephan, A. M., Marchi, N. A., Haba-Rubio, J., & Siclari, F. (2022) · Sleep · doi:10.1093/sleep/zsac111 · Cited by 33
Mind and body: psychophysiological profiles of instructional and motivational self-talk
Bellomo, E., Cooke, A., Gallicchio, G., Ring, C., & Hardy, J. (2020) · Psychophysiology · doi:10.1111/psyp.13586 · Cited by 33
“Offline signal processing was performed using EEGLAB (Delorme & Makeig, 2004), ERPLAB (Lopez-Calderon & Luck, 2014), and bespoke scripts in MATLAB (Mathworks Inc., USA).”
MethodEmotion assessment using Machine Learning and low-cost wearable devices
Laureanti, R., Bilucaglia, M., Zito, M., Circi, R., Fici, A., Rivetti, F., Valesi, R., Oldrini, C., Mainardi, L. T., & Russo, V. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175221 · Cited by 33
“The EEG recordings were processed in Matlab (The Mathworks, Inc.), using the EEGLab toolbox [13].”
MethodArciniega, H., Shires, J., Furlong, S., Kilgore-Gomez, A., Cerreta, A., Murray, N. G., & Berryhill, M. E. (2021) · Scientific Reports · doi:10.1038/s41598-021-80995-1 · Cited by 33
Dynamic imaging of seizure activity in pediatric epilepsy patients
Lu, Y., Yang, L., Worrell, G. A., Brinkmann, B., Nelson, C., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.021 · Cited by 32
“In the analysis, the seizure EEG was decomposed into temporally independent and spatially fixed components using the independent component analysis (ICA) in the following format (Nam et al., 2002; Delorme and Makeig, 2004; Jung et al., 2009; Yang et al., 2011):”
MethodAmphetamine alters an EEG marker of reward processing in humans and mice
Cavanagh, J. F., Olguin, S. L., Talledo, J. A., Kotz, J. E., Roberts, B. Z., Nungaray, J. A., Sprock, J., Gregg, D., Bhakta, S. G., Light, G. A., et al. (2022) · Psychopharmacology · doi:10.1007/s00213-022-06082-z · Cited by 32
Peitek, N., Bergum, A., Rekrut, M., Mucke, J., Nadig, M., Parnin, C., Siegmund, J., & Apel, S. (2022) · Proceedings of the 30th ACM Joint European Software Engineering Conference and Symposium on the Foundations of Software Engineering · doi:10.1145/3540250.3549084 · Cited by 32
“The used EEGLAB toolbox [19]8 provides an automated implementation of the independent component analysis (ICA).”
MethodBozhilova, N., Cooper, R., Kuntsi, J., Asherson, P., & Michelini, G. (2020) · Behavioural Brain Research · doi:10.1016/j.bbr.2020.112632 · Cited by 32
“The ITC index shows the level of phase consistency of the evoked response across all trials at a given latency and frequency [45,50,51].”
Single trial prestimulus oscillations predict perception of the sound-induced flash illusion
Kaiser, M., Senkowski, D., Busch, N. A., Balz, J., & Keil, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-42380-x · Cited by 31
Electrophysiological traces of visuomotor learning and their renormalization after sleep
Landsness, E. C., Ferrarelli, F., Sarasso, S., Goldstein, M. R., Riedner, B. A., Cirelli, C., Perfetti, B., Moisello, C., Ghilardi, M. F., & Tononi, G. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.05.001 · Cited by 31
“Independent Component Analysis (ICA), as implemented in EEGLAB (Delorme and Makeig, 2004), was used to remove ocular, muscle and EKG artifacts.”
MethodMu rhythm suppression is associated with the classification of emotion in faces
Moore, M. R., & Franz, E. A. (2017) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/s13415-016-0476-6 · Cited by 30
Schade, M. M., Mathew, G. M., Roberts, D. M., Gartenberg, D., & Buxton, O. (2020) · Nature and Science of Sleep · doi:10.2147/nss.s243204 · Cited by 30
“Spectral analysis was implemented using MATLAB (Natick, MA) in conjunction with the EEGLAB toolbox and custom scripts.(24) EEG recordings were re-referenced to the average of the left and right mastoid electrodes.”
MethodEEG-based spatio-temporal relation signatures for the diagnosis of depression and schizophrenia
Shor, O., Yaniv-Rosenfeld, A., Valevski, A., Weizman, A., Khrennikov, A., & Benninger, F. (2023) · Scientific Reports · doi:10.1038/s41598-023-28009-0 · Cited by 30
Lost in Transition: Aging-Related Changes in Executive Control by the Medial Prefrontal Cortex
Caetano, M. S., Horst, N. K., Harenberg, L., Liu, B., Arnsten, A. F. T., & Laubach, M. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.6011-11.2012 · Cited by 30
“Then, PCA was done for N leading components in MATLAB as follows: [u,s,v] svd(X ,0); U u(:,1:N ); l diag(s).”
MethodInfluentialEEG Lempel-Ziv complexity varies with sleep stage, but does not seem to track dream experience
Aamodt, A., Sevenius Nilsen, A., Markhus, R., Kusztor, A., HasanzadehMoghadam, F., Kauppi, N., Thürer, B., Storm, J. F., & Juel, B. E. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.987714 · Cited by 30
“Data was then exported for automatic preprocessing using the EEGLAB MATLAB toolbox (Delorme and Makeig, 2004).”
MethodLeo, A., Naro, A., Cannavò, A., Pisani, L. R., Bruno, R., Salviera, C., Bramanti, P., & Calabrò, R. S. (2016) · Experimental Brain Research · doi:10.1007/s00221-016-4622-8 · Cited by 29
Fischer, A. G., Endrass, T., Reuter, M., Kubisch, C., & Ullsperger, M. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.5124-14.2015 · Cited by 29
“0 (Delorme and Makeig, 2004) and custom code written in MATLAB 2012b (MathWorks).”
BackgroundMethodInfluentialDeepVANet: A Deep End-to-End Network for Multi-modal Emotion Recognition
Zhang, Y., Hossain, M. Z., & Rahman, S. (2021) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-85613-7_16 · Cited by 29
Brush, C. J., Foti, D., Bocchine, A. J., Muniz, K. M., Gooden, M. J., Spaeth, A. M., Miller, M. W., & Alderman, B. L. (2020) · Mental health and physical activity · doi:10.1016/j.mhpa.2020.100339 · Cited by 29
Opie, G. M., Foo, N., Killington, M., Ridding, M. C., & Semmler, J. G. (2019) · Journal of Neurotrauma · doi:10.1089/neu.2018.6353 · Cited by 29
Knight, E. J., Oakes, L., Hyman, S. L., Freedman, E. G., & Foxe, J. J. (2020) · Autism Research · doi:10.1002/aur.2362 · Cited by 29
“EEG data were processed and analyzed offline using custom scripts that included functions from the EEGLAB (Delorme & Makeig, 2004) and ERPLAB Toolboxes (Lopez-Calderon & Luck, 2014) for MATLAB (the MathWorks, Natick, MA, USA).”
Method
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.