EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 401–500 of 1,311
Brain wave synchronization and entrainment to periodic acoustic stimuli
Will, U., & Berg, E. (2007) · Neuroscience Letters · doi:10.1016/j.neulet.2007.07.036 · Cited by 209
“ITC calculations were done with our own MATLABcript using the ‘phasecoher’ function from EEGLAB [5].”
MethodSustained Attention in Real Classroom Settings: An EEG Study
Ko, L.-W., Komarov, O., Hairston, W. D., Jung, T.-P., & Lin, C.-T. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00388 · Cited by 219
“The data processing was performed using EEGLAB (Delorme and Makeig, 2004), a toolbox for MATLAB.”
Combined Electrophysiological and Behavioral Evidence for the Suppression of Salient Distractors
Gaspelin, N., & Luck, S. J. (2018) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01279 · Cited by 219
“All analyses after data acquisition were conducted using ERPLAB Toolbox (Lopez-Calderon & Luck, 2014) and EEGLAB Toolbox (Delorme & Makeig, 2004).”
MethodCrosse, M. J., Butler, J. S., & Lalor, E. C. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.1829-15.2015 · Cited by 208
“Channels contaminated by noise were recalculated by spline-interpolating the surrounding clean channels in EEGLAB (Delorme and Makeig, 2004).”
MethodCohen, M. X., Elger, C. E., & Fell, J. (2008) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2008.21020 · Cited by 218
“Filtering was done using a two-way, least-squares FIR procedure (as implemented in the eegfilt.m script included in the EEGLAB package; Delorme & Makeig, 2004).”
MethodHippocampal Gamma Oscillations Increase with Memory Load
van Vugt, M. K., Schulze-Bonhage, A., Litt, B., Brandt, A., & Kahana, M. J. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.0567-09.2010 · Cited by 218
“1, available at www.jneurosci.org as supplemental material); events were discarded if their kurtosis exceeded a threshold of 5 (Delorme and Makeig, 2004; Robinson et al., 2004; Sederberg et al., 2007a).”
Direct brain recordings reveal hippocampal rhythm underpinnings of language processing
Piai, V., Anderson, K. L., Lin, J. J., Dewar, C., Parvizi, J., Dronkers, N. F., & Knight, R. T. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1603312113 · Cited by 218
“Delorme A, Makeig S (2004) EEGLAB: An open source toolbox for analysis of singletrial EEG dynamics including independent component analysis.”
MethodToward a reliable, automated method of individual alpha frequency (IAF) quantification
Corcoran, A. W., Alday, P. M., Schlesewsky, M., & Bornkessel‐Schlesewsky, I. (2018) · Psychophysiology · doi:10.1111/psyp.13064 · Cited by 202
Milne, E. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00051 · Cited by 217
“At this stage, the data were (i) decomposed by extended infomax ICA using the function runica, as implemented in EEGLAB, and then segmented into epochs associated with presentation of the high spatial frequency Gabor patch (8 cycles/degree); epochs were 800 ms long (−100 ms pre-stimulus), and baseline corrected by sub…”
MethodInfluentialFrontal Theta Overrides Pavlovian Learning Biases
Cavanagh, J. F., Eisenberg, I., Guitart-Masip, M., Huys, Q., & Frank, M. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.5754-12.2013 · Cited by 199
“Blinks were removed using independent component analysis from EEGLab (Delorme and Makeig, 2004).”
MethodHigh Theta and Low Alpha Powers May Be Indicative of BCI-Illiteracy in Motor Imagery
Ahn, M., Cho, H., Ahn, S., & Jun, S. C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080886 · Cited by 209
“On the other bands, the spectral powers were estimated by using a fast Fourier transform on the time series for each channel with an EEGLAB library [25].”
MethodKetamine Modulates Theta and Gamma Oscillations
Lazarewicz, M. T., Ehrlichman, R. S., Maxwell, C. R., Gandal, M. J., Finkel, L. H., & Siegel, S. J. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21305 · Cited by 209
Debener, S., Mullinger, K. J., Niazy, R. K., & Bowtell, R. W. (2008) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.05.015 · Cited by 205
Individual Differences in Frequency and Topography of Slow and Fast Sleep Spindles
Cox, R., Schapiro, A. C., Manoach, D. S., & Stickgold, R. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00433 · Cited by 194
Infra-Slow EEG Fluctuations Are Correlated with Resting-State Network Dynamics in fMRI
Hiltunen, T., Kantola, J., Abou Elseoud, A., Lepola, P., Suominen, K., Starck, T., Nikkinen, J., Remes, J., Tervonen, O., Palva, S., et al. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.0276-13.2014 · Cited by 214
“…fbEEG data were exported to MATLAB (MathWorks) where the independent components analysis (ICA) was calculated with EEGLAB (version 9.0.0.2b; Delorme and Makeig, 2004) using the Infomax algorithm (Bell and Sejnowski, 1995), which is recommended in EEGLAB tutorial with sub-Gaussian sources…”
MethodInfluentialTranscranial Focused Ultrasound Modulates Intrinsic and Evoked EEG Dynamics
Mueller, J., Legon, W., Opitz, A., Sato, T. F., & Tyler, W. J. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.08.008 · Cited by 214
“, Natick, MA) using custom scripts and EEGLAB [13].”
MethodDICE-Net: A Novel Convolution-Transformer Architecture for Alzheimer Detection in EEG Signals
Miltiadous, A., Gionanidis, E., Tzimourta, K. D., Giannakeas, N., & Tzallas, A. T. (2023) · IEEE Access · doi:10.1109/access.2023.3294618 · Cited by 191
“‘‘ICLabel’’ in the EEGLAB platform [44] were automatically rejected.”
MethodMajid Mehmood, R., Du, R., & Lee, H. J. (2017) · IEEE Access · doi:10.1109/access.2017.2724555 · Cited by 213
“After the recorded EEG data of each subject were verified, the EEG signals were preprocessed using the EEGLAB tool-box provided by SCCN Lab [36].”
MethodHesse, S., Kreuzer, M., Hight, D., Gaskell, A., Devari, P., Singh, D., Taylor, N. B., Whalin, M. K., Lee, S., Sleigh, J. W., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.09.016 · Cited by 213
Hanslmayr, S., Volberg, G., Wimber, M., Raabe, M., Greenlee, M. W., & Bäuml, K.-H. T. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.3140-11.2011 · Cited by 195
“Both artifacts were removed using the FMRIB plug-in for EEGLAB (Delorme and Makeig, 2004; Niazy et al., 2005), running under MATLAB (The MathWorks).”
Effects of Working Memory Load on Oscillatory Power in Human Intracranial EEG
Meltzer, J. A., Zaveri, H. P., Goncharova, I. I., Distasio, M. M., Papademetris, X., Spencer, S. S., Spencer, D. D., & Constable, R. T. (2008) · Cerebral Cortex · doi:10.1093/cercor/bhm213 · Cited by 197
“Digitized intracranial EEG was imported into MATLAB (Mathworks, Natick, MA) for analysis, using EEGLAB software (Delorme and Makeig 2004) and custom-written scripts.”
MethodResting-state slow wave power, healthy aging and cognitive performance
Vlahou, E. L., Thurm, F., Kolassa, I.-T., & Schlee, W. (2014) · Scientific Reports · doi:10.1038/srep05101 · Cited by 203
LGGNet: Learning From Local-Global-Graph Representations for Brain–Computer Interface
Ding, Y., Robinson, N., Tong, C., Zeng, Q., & Guan, C. (2024) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2023.3236635 · Cited by 211
“The automatic artifact removal (AAR) method in EEGLab [50] was used to remove ocular and muscular artifacts.”
MethodValidation of ICA-based myogenic artifact correction for scalp and source-localized EEG
McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Bachhuber, D. R. W., Koppenhaver, A. M., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.010 · Cited by 211
EEG-based prediction of driver's cognitive performance by deep convolutional neural network
Hajinoroozi, M., Mao, Z., Jung, T.-P., Lin, C.-T., & Huang, Y. (2016) · Signal Processing: Image Communication · doi:10.1016/j.image.2016.05.018 · Cited by 210
Sleep spindle refractoriness segregates periods of memory reactivation
Antony, J. W., Piloto, L., Wang, M., Pacheco, P., Norman, K. A., & Paller, K. A. (2018) · Current Biology · doi:10.1016/j.cub.2018.04.020 · Cited by 208
Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208
The influence of anhedonia on feedback negativity in major depressive disorder
Liu, W.-H., Wang, L.-Z., Shang, H.-R., Shen, Y., Li, Z., Cheung, E. F. C., & Chan, R. C. K. (2014) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2013.11.023 · Cited by 199
“The EEGLAB Matlab toolbox (Delorme & Makeig, 2004) and the ERPLAB software (http://erpinfo. org/erplab) were used for EEG offline processing and analysis.”
MethodDistinct Mechanisms for Distractor Suppression and Target Facilitation
Noonan, M. P., Adamian, N., Pike, A., Printzlau, F., Crittenden, B. M., & Stokes, M. G. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.2133-15.2016 · Cited by 192
“Preprocessing of the raw EEG data collected in Experiment 3 used EEGLAB version 12.4.3b (Delorme and Makeig, 2004).”
MethodInfluentialIdentifying reliable independent components via split-half comparisons
Groppe, D. M., Makeig, S., & Kutas, M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.038 · Cited by 207
“, 1999) was individually applied to each participant's data from each experiment using the binica function from the EEGLAB Toolbox (Delorme and Makeig, 2004).”
MethodSelf-citationEtard, O., & Reichenbach, T. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.1828-18.2019 · Cited by 206
“…one-pass forward and compensated for delay], downsampled to 100 Hz, and high-pass filtered 1 Hz [linear phase FIR filter, cutoff ( 6 dB) 0.5 Hz, order 322; transition bandwidth 1 Hz, one-pass forward and compensated for delay] using functions from the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodInfluentialPreferential decoding of emotion from human non-linguistic vocalizations versus speech prosody
Pell, M. D., Rothermich, K., Liu, P., Paulmann, S., Sethi, S., & Rigoulot, S. (2015) · Biological Psychology · doi:10.1016/j.biopsycho.2015.08.008 · Cited by 191
“The subsequent data were re-referenced offline to the average of the electrodes and then filtered with a band pass of 0.01 and 30 Hz using EEGLab (Delorme & Makeig, 2004).”
InfluentialGlobal gain modulation generates time-dependent urgency during perceptual choice in humans
Murphy, P. R., Boonstra, E., & Nieuwenhuis, S. (2016) · Nature Communications · doi:10.1038/ncomms13526 · Cited by 201
Age-related changes in the subcortical–cortical encoding and categorical perception of speech
Bidelman, G. M., Villafuerte, J. W., Moreno, S., & Alain, C. (2014) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2014.05.006 · Cited by 203
Gandal, M. J., Sisti, J., Klook, K., Ortinski, P. I., Leitman, V, Liang, Y., Thieu, T., Anderson, R., Pierce, R. C., Jonak, G., et al. (2012) · Translational Psychiatry · doi:10.1038/tp.2012.69 · Cited by 204
“Signal processing was performed using EEGLab in Matlab, as published.(21,50)”
MethodPrestimulus theta activity predicts correct source memory retrieval
Addante, R. J., Watrous, A. J., Yonelinas, A. P., Ekstrom, A. D., & Ranganath, C. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014528108 · Cited by 204
Isolating gait-related movement artifacts in electroencephalography during human walking
Kline, J. E., Huang, H. J., Snyder, K. L., & Ferris, D. P. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046022 · Cited by 204
“We used bootstrapping methods available in EEGLAB (Delorme and Makeig 2004) to determine regions of significant difference from baseline (p 0.05).”
MethodInfluentialTheta frontoparietal connectivity associated with proactive and reactive cognitive control processes
Cooper, P. S., Wong, A. S. W., Fulham, W. R., Thienel, R., Mansfield, E., Michie, P. T., & Karayanidis, F. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.028 · Cited by 186
“EEG data were processed using MATLAB 2011b through a pipeline utilizing Fieldtrip (Oostenveld et al., 2011), EEGLab (Delorme and Makeig, 2004), CSD Toolbox (Kayser and Tenke, 2006), and in-house functions (see Fig.”
EEG power spectral slope differs by ADHD status and stimulant medication exposure in early childhood
Robertson, M. M., Furlong, S., Voytek, B., Donoghue, T., Boettiger, C. A., & Sheridan, M. A. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00388.2019 · Cited by 203
“We identified and removed eye blinks and muscle movements using independent components analysis (ICA) in EEGLAB (Delorme and Makeig 2004).”
MethodSpatiotemporal Dependency of Age-Related Changes in Brain Signal Variability
McIntosh, A. R., Vakorin, V., Kovacevic, N., Wang, H., Diaconescu, A., & Protzner, A. B. (2014) · Cerebral Cortex · doi:10.1093/cercor/bht030 · Cited by 203
“Artifact removal was performed using independent component analysis in EEGLAB (Delorme and Makeig 2004).”
MethodTowards a truly mobile auditory brain–computer interface: Exploring the P300 to take away
De Vos, M., Gandras, K., & Debener, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.08.010 · Cited by 203
Neural decoding of treadmill walking from noninvasive electroencephalographic signals
Presacco, A., Goodman, R., Forrester, L., & Contreras-Vidal, J. L. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00104.2011 · Cited by 203
“The topoplot function of EEGLAB (Delorme and Makeig 2004; http://sccn.ucsd.edu/eeglab/) was used to plot the correlation values.”
MethodVijayan, S., Ching, S., Purdon, P. L., Brown, E. N., & Kopell, N. J. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.5670-12.2013 · Cited by 198
“3 Hz EEG activity over the surface of the scalp were calculated using the spectopo function in the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodInfluentialCortical reorganization in children with cochlear implants
Gilley, P. M., Sharma, A., & Dorman, M. F. (2008) · Brain Research · doi:10.1016/j.brainres.2008.08.026 · Cited by 191
“Toolbox (EEGLAB, San Diego, CA) under the public GNU license ( Delorme and Makeig, 2004 ).”
MethodSlow-wave activity saturation and thalamocortical isolation during propofol anesthesia in humans
Ní Mhuircheartaigh, R., Warnaby, C., Rogers, R., Jbabdi, S., & Tracey, I. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006007 · Cited by 202
Mobile EEG in research on neurodevelopmental disorders: Opportunities and challenges
Lau-Zhu, A., Lau, M. P. H., & McLoughlin, G. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100635 · Cited by 201
Kuan, K. K. Y., Zhong, Y., & Chau, P. Y. K. (2014) · Journal of Management Information Systems · doi:10.2753/mis0742-1222300406 · Cited by 201
Evaluation of PCA and ICA of simulated ERPs: Promax vs. infomax rotations
Dien, J., Khoe, W., & Mangun, G. R. (2007) · Human Brain Mapping · doi:10.1002/hbm.20304 · Cited by 201
“Since there are many varieties of ICA, this report will focus on the version r D ien et al. r r 744 r most commonly applied to ERP data, the Infomax rotation [Bell and Sejnowski, 1995], as implemented by the EEGlab toolkit [Delorme and Makeig, 2004].”
MethodInfluentialDebener, S., Strobel, A., Sorger, B., Peters, J., Kranczioch, C., Engel, A. K., & Goebel, R. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.031 · Cited by 201
Frontal Oscillatory Dynamics Predict Feedback Learning and Action Adjustment
van de Vijver, I., Ridderinkhof, K. R., & Cohen, M. X. (2011) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00110 · Cited by 180
“Differences in average RT adjustments after each possible feedback (positive, speed up or slow down) were tested with a one-way ANOVA using Statistical Package for the Social Sciences for Windows (Version 15.0; SPSS, Inc., Chicago, IL) software.”
InfluentialŠkola, F., Rizvić, S., Cozza, M., Barbieri, L., Bruno, F., Skarlatos, D., & Liarokapis, F. (2020) · Sensors · doi:10.3390/s20205851 · Cited by 180
“The recorded data were analyzed using EEGLAB [53].”
MethodBeta band oscillations engagement in human alertness process
Kamiński, J., Brzezicka, A., Gola, M., & Wróbel, A. (2012) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2011.11.006 · Cited by 200
A brain-computer interface with vibrotactile biofeedback for haptic information
Chatterjee, A., Aggarwal, V., Ramos, A., Acharya, S., & Thakor, N. V. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-40 · Cited by 194
Wang, D., Chen, J., Zhao, D., Dai, F., Zheng, C., & Wu, X. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.02.001 · Cited by 189
Differences in unity: The go/no-go and stop signal tasks rely on different mechanisms
Raud, L., Westerhausen, R., Dooley, N., & Huster, R. J. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116582 · Cited by 199
EEG Alpha Power Modulation of fMRI Resting-State Connectivity
Scheeringa, R., Petersson, K. M., Kleinschmidt, A., Jensen, O., & Bastiaansen, M. C. M. (2012) · Brain Connectivity · doi:10.1089/brain.2012.0088 · Cited by 199
“Here we applied extended info-max independent component analysis (ICA) (Lee et al., 1999) as implemented in EEGLab 6.01 (Delorme and Makeig, 2004) on 7–13-Hz band-pass-filtered EEG data.”
InfluentialDisentangling EEG responses to TMS due to cortical and peripheral activations
Rocchi, L., Di Santo, A., Brown, K., Ibáñez, J., Casula, E., Rawji, V., Di Lazzaro, V., Koch, G., & Rothwell, J. (2021) · Brain Stimulation · doi:10.1016/j.brs.2020.10.011 · Cited by 199
“1 (16) with the addition 252 of some functions included in the TMS-EEG signal analyser (TESA) toolbox (17) and in 253 Fieldtrip open source MATLAB toolbox (18), all running in MATLAB environment (Version 254 2016b, MathWorks Inc.”
BackgroundA motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees
Li, X., Samuel, O. W., Zhang, X., Wang, H., Fang, P., & Li, G. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0212-z · Cited by 199
“1991) [19] was applied to process the EEG data, where the mean of baseline for each channel was removed and the EEG epochs of each motion class was extracted based on the onset-endpoint lines.”
ELAN: A Software Package for Analysis and Visualization of MEG, EEG, and LFP Signals
Aguera, P.-E., Jerbi, K., Caclin, A., & Bertrand, O. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/158970 · Cited by 185
“This is currently possible via a provided MATLAB function that applies ICA functions to the ELAN data file using the freely available EEGLab toolbox [3].”
MethodTest–retest reliability of resting EEG spectra validates a statistical signature of persons
Näpflin, M., Wildi, M., & Sarnthein, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.022 · Cited by 196
“The data were analysed offline in the Matlab (The Matworks, Natick, MA, USA) environment using EEGLAB (http://sccn.ucsd.edu/eeglab (Delorme and Makeig, 2004)) and custom programming on the basis of standard mathematical and signal analysis functions.”
MethodHeterogeneous neuronal firing patterns during interictal epileptiform discharges in the human cortex
Keller, C. J., Truccolo, W., Gale, J. T., Eskandar, E., Thesen, T., Carlson, C., Devinsky, O., Kuzniecky, R., Doyle, W. K., Madsen, J. R., et al. (2010) · Brain · doi:10.1093/brain/awq112 · Cited by 194
Compensatory changes in cortical resource allocation in adults with hearing loss
Campbell, J., & Sharma, A. (2013) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2013.00071 · Cited by 198
“Individual EEG data was then exported from Net Station and imported into the EEGLAB toolbox (Delorme and Makeig, 2004) supported by MatLab (The MathWorks®, Inc., 2010).”
MethodNikulin, V. V., Nolte, G., & Curio, G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.057 · Cited by 198
Artoni, F., Delorme, A., & Makeig, S. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.016 · Cited by 198
“Given the high– Delorme and Makeig, 2004 dimensionality of the time and frequency features, the dimensionality of the resulting joint vector was reduced to 15 principal components by PCA, which explained 95% of the feature variance ( ).”
BackgroundSelf-citationSingle‐trial analysis of oddball event‐related potentials in simultaneous EEG‐fMRI
Bénar, C., Schön, D., Grimault, S., Nazarian, B., Burle, B., Roth, M., Badier, J., Marquis, P., Liegeois‐Chauvel, C., & Anton, J. (2007) · Human Brain Mapping · doi:10.1002/hbm.20289 · Cited by 192
“We then exported the rare events to the EEGLAB tool-box [Delorme and Makeig, 2004] within the Matlab software (MathWorks, Natick, MA).”
MethodRomero, S., Mañanas, M. A., & Barbanoj, M. J. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.12.001 · Cited by 191
“Besides, some of the ICA algorithms that were evaluated and inadvisable in [10] require much longer data segments than the epoch duration considered in that study in order to work properly [13].”
BackgroundMethodFrequency and Phase Mixed Coding in SSVEP-Based Brain--Computer Interface
Jia, C., Gao, X., Hong, B., & Gao, S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068571 · Cited by 197
Behavioral Oscillations in Attention: Rhythmic α Pulses Mediated through θ Band
Song, K., Meng, M., Chen, L., Zhou, K., & Luo, H. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.4856-13.2014 · Cited by 196
“Behavioral RT data were analyzed with MATLAB (MathWorks) partly using functions from the EEGLAB toolbox (Delorme and Makeig, 2004), wavelet toolbox, and CircStat toolbox (Berens, 2009).”
MethodExtracting Multi-Person Respiration from Entangled RF Signals
Yue, S., He, H., Wang, H., Rahul, H., & Katabi, D. (2018) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3214289 · Cited by 196
“ICA has been used in many domains including speech and image processing, text mining, financial data processing, communication systems, and EEG processing [11, 24, 28, 33, 38, 39].”
Towards multilevel mental stress assessment using SVM with ECOC: an EEG approach
Al-shargie, F., Tang, T. B., Badruddin, N., & Kiguchi, M. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1733-8 · Cited by 192
Selective neuronal lapses precede human cognitive lapses following sleep deprivation
Nir, Y., Andrillon, T., Marmelshtein, A., Suthana, N., Cirelli, C., Tononi, G., & Fried, I. (2017) · Nature Medicine · doi:10.1038/nm.4433 · Cited by 197
Active learning for regression using greedy sampling
Wu, D., Lin, C.-T., & Huang, J. (2019) · Information Sciences · doi:10.1016/j.ins.2018.09.060 · Cited by 183
ZapLine: A simple and effective method to remove power line artifacts
de Cheveigné, A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116356 · Cited by 178
Sharp edge artifacts and spurious coupling in EEG frequency comodulation measures
Kramer, M. A., Tort, A. B. L., & Kopell, N. J. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.01.020 · Cited by 195
Fluctuations in Oscillation Frequency Control Spike Timing and Coordinate Neural Networks
Cohen, M. X. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.0261-14.2014 · Cited by 195
“Further cleaning was done through independent components analysis using the eeglab toolbox (Delorme and Makeig, 2004).”
Control of working memory by phase–amplitude coupling of human hippocampal neurons
Daume, J., Kamiński, J., Schjetnan, A. G. P., Salimpour, Y., Khan, U., Kyzar, M., Reed, C. M., Anderson, W. S., Valiante, T. A., Mamelak, A. N., et al. (2024) · Nature · doi:10.1038/s41586-024-07309-z · Cited by 167
The Amsterdam Resting-State Questionnaire reveals multiple phenotypes of resting-state cognition
Diaz, B. A., Van Der Sluis, S., Moens, S., Benjamins, J. S., Migliorati, F., Stoffers, D., Den Braber, A., Poil, S.-S., Hardstone, R., Van't Ent, D., et al. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00446 · Cited by 194
Stomach-brain synchrony reveals a novel, delayed-connectivity resting-state network in humans
Rebollo, I., Devauchelle, A.-D., Béranger, B., & Tallon-Baudry, C. (2018) · eLife · doi:10.7554/elife.33321 · Cited by 194
“Heart rate variability analysis We first removed the MRI gradient artefact from the ECG data using the FMRIB plug-in (Iannetti et al., 2005; Niazy et al., 2005, version 1.21) for EEGLAB (Delorme and Makeig, 2004, version 14.1.1), provided by the University of Oxford Centre for Functional MRI of the Brain (FMRIB).”
MethodInfluentialEEG Recorded from the Ear: Characterizing the Ear-EEG Method
Mikkelsen, K. B., Kappel, S. L., Mandic, D. P., & Kidmose, P. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00438 · Cited by 194
“Each channel was subjected to a bandpass filter, using the FIR filter in EEGLAB with pass band 3-30 Hz.”
MethodRevealing hidden states in visual working memory using electroencephalography
Wolff, M. J., Ding, J., Myers, N. E., & Stokes, M. G. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00123 · Cited by 194
“Offline, the signal was re-referenced to the average of both mastoids, down-sampled to 250 Hz with 16-bit precision and band pass filtered (0.1 Hz high-pass and 40 Hz low-pass) using EEGLAB (Delorme and Makeig, 2004).”
MethodInfluentialPfabigan, D. M., Alexopoulos, J., Bauer, H., & Sailer, U. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01136.x · Cited by 177
The infant mirror neuron system studied with high density EEG
Nyström, P. (2008) · Social Neuroscience · doi:10.1080/17470910701563665 · Cited by 189
“After the experiment the data were transferred to the EEGLAB toolbox (version 5.03; Delorme & Makeig, 2004) in the Matlab environment for off-line analysis.”
MethodInfluentialVaisvaser, S., Lin, T., Admon, R., Podlipsky, I., Greenman, Y., Stern, N., Fruchter, E., Wald, I., Pine, D. S., Tarrasch, R., et al. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00313 · Cited by 184
“Briefly, gradient artifacts were removed using FASTR algorithm (Niazy et al., 2005), implemented in FMRIB plug-in for EEGLAB (Delorme and Makeig, 2004).”
BackgroundMethodAmygdala-hippocampal dynamics during salient information processing
Zheng, J., Anderson, K. L., Leal, S. L., Shestyuk, A., Gulsen, G., Mnatsakanyan, L., Vadera, S., Hsu, F. P. K., Yassa, M. A., Knight, R. T., et al. (2017) · Nature Communications · doi:10.1038/ncomms14413 · Cited by 180
Distinct β Band Oscillatory Networks Subserving Motor and Cognitive Control during Gait Adaptation
Wagner, J., Makeig, S., Gola, M., Neuper, C., & Müller-Putz, G. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.3543-15.2016 · Cited by 193
“Significant deviations from the baseline were detected using a nonparametric bootstrap approach (Delorme and Makeig, 2004).”
MethodSelf-citationFrontal theta is a signature of successful working memory manipulation
Itthipuripat, S., Wessel, J. R., & Aron, A. R. (2013) · Experimental Brain Research · doi:10.1007/s00221-012-3305-3 · Cited by 193
“0.0.2b (Delorme and Makeig 2004).”
InfluentialBSMART: A Matlab/C toolbox for analysis of multichannel neural time series
Cui, J., Xu, L., Bressler, S. L., Ding, M., & Liang, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.05.007 · Cited by 193
“A unique feature of BSMART is that instead of using the nonparametric approach to analysis adopted in most previous toolboxes (Delorme & Makeig, 2004; Morup et al., 2007), it carries out analyses based on a parametric method involving the Adaptive Multivariate AutoRegressive (AMAR) modeling…”
InfluentialDi Flumeri, G., Aricò, P., Borghini, G., Sciaraffa, N., Di Florio, A., & Babiloni, F. (2019) · Sensors · doi:10.3390/s19061365 · Cited by 173
“For other sources of artefacts, specific procedures of the EEGLAB toolbox were applied [66].”
MethodBrain Oscillations in Sport: Toward EEG Biomarkers of Performance
Cheron, G., Petit, G., Cheron, J., Leroy, A., Cebolla, A., Cevallos, C., Petieau, M., Hoellinger, T., Zarka, D., Clarinval, A.-M., et al. (2016) · Frontiers in Psychology · doi:10.3389/fpsyg.2016.00246 · Cited by 192
Processing of unattended facial emotions: A visual mismatch negativity study
Stefanics, G., Csukly, G., Komlósi, S., Czobor, P., & Czigler, I. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.041 · Cited by 192
“Subsequent data analyses were carried out off-line using built-in and self-developed functions as well as the freeware EEGLAB toolbox (Delorme and Makeig, 2004) in the Matlab (MathWorks, Natick, MA) development environment.”
N200-speller using motion-onset visual response
Hong, B., Guo, F., Liu, T., Gao, X., & Gao, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.06.026 · Cited by 192
“All data analyses were carried out using MATLAB (Mathworks, USA), libSVM (Chang and Lin, 2001) and EEGLAB (Delorme and Makeig, 2004).”
MethodVosskuhl, J., Huster, R. J., & Herrmann, C. S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00257 · Cited by 191
“All data analyses were performed using MATLAB (Version 7.11.0, The Mathworks Inc, Natick, MA, USA) and functions of the EEGLAB toolbox (Delorme and Makeig, 2004).”
MethodInfluentialBeyond self-serving bias: diffusion of responsibility reduces sense of agency and outcome monitoring
Beyer, F., Sidarus, N., Bonicalzi, S., & Haggard, P. (2017) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsw160 · Cited by 171
Frequency and power of human alpha oscillations drift systematically with time-on-task
Benwell, C. S. Y., London, R. E., Tagliabue, C. F., Veniero, D., Gross, J., Keitel, C., & Thut, G. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.067 · Cited by 167
“Experiment 1 pre-processing Pre-processing was performed using a combination of custom scripts incorporating EEGLAB (Delorme and Makeig, 2004) and FieldTrip (Oostenveld et al., 2011) functions in Matlab (Mathworks, USA).”
MethodInfluentialSystematic biases in early ERP and ERF components as a result of high-pass filtering
Acunzo, D. J., MacKenzie, G., & van Rossum, M. C. W. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.06.011 · Cited by 190
“Data processing Pre-processing was performed using the EEGLAB toolbox Delorme and Makeig, 2004) under Matlab (Mathworks, Inc., ce Methods 209 (2012) 212– 218 Natick, MA, USA), and custom scripts.”
MethodRapid and Direct Encoding of Numerosity in the Visual Stream
Park, J., DeWind, N. K., Woldorff, M. G., & Brannon, E. M. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhv017 · Cited by 170
“Event-related potential analyses were carried out using the EEGLAB (Delorme and Makeig 2004) and its ERPLAB toolbox”
MethodInfluentialEEG Correlates of Self-Referential Processing
Knyazev, G. G. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00264 · Cited by 189
“These debates have partly lost their actuality due to the advent of modern methods of time-frequency representation, such as wavelet transform, and adoption of mass-univariate statistical approaches (e.g., Delorme and Makeig, 2004).”
MethodFast fMRI can detect oscillatory neural activity in humans
Lewis, L. D., Setsompop, K., Rosen, B. R., & Polimeni, J. R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608117113 · Cited by 189
“Delorme A, Makeig S (2004) EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.”
MethodAkhtar, M. T., Mitsuhashi, W., & James, C. J. (2012) · Signal Processing · doi:10.1016/j.sigpro.2011.08.005 · Cited by 189
Minimization of cochlear implant stimulus artifact in cortical auditory evoked potentials
Gilley, P. M., Sharma, A., Dorman, M., Finley, C. C., Panch, A. S., & Martin, K. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.018 · Cited by 189
“The EEG files were imported in to the Matlab environment using the EEGLAB Toolbox (EEGLAB, San Diego, CA) under the public GNU license (Delorme and Makeig, 2004).”
Method
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.