EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 201–300 of 1,311
Awais, M., Badruddin, N., & Drieberg, M. (2017) · Sensors · doi:10.3390/s17091991 · Cited by 285
Clinical Utility of EEG in Attention-Deficit/Hyperactivity Disorder: A Research Update
Loo, S. K., & Makeig, S. (2012) · Neurotherapeutics · doi:10.1007/s13311-012-0131-z · Cited by 306
Self-citationDissociating N400 Effects of Prediction from Association in Single-word Contexts
Lau, E. F., Holcomb, P. J., & Kuperberg, G. R. (2013) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00328 · Cited by 284
“Averaged ERPs time-locked to target words were formed off-line from trials free of ocular and muscular artifact using preprocessing routines made available by the EEGLAB (Delorme & Makeig, 2004) and ERPLAB (erpinfo.org/ erplab) toolboxes.”
Open Access Dataset for EEG+NIRS Single-Trial Classification
Shin, J., von Luhmann, A., Blankertz, B., Kim, D.-W., Jeong, J., Hwang, H.-J., & Muller, K.-R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2628057 · Cited by 287
Local and long-range functional connectivity is reduced in concert in autism spectrum disorders
Khan, S., Gramfort, A., Shetty, N. R., Kitzbichler, M. G., Ganesan, S., Moran, J. M., Lee, S. M., Gabrieli, J. D. E., Tager-Flusberg, H. B., Joseph, R. M., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1214533110 · Cited by 303
“Coherence between the FFA and the rest of the cortex was computed by first averaging the time course across all vertices within the FFA and then computing the eventrelated coherence (59, 60) between the average FFA time course and each of the other vertices on the cortex, for every frequency between 6 Hz and 55 Hz, us…”
MethodNeural Suppression of Irrelevant Information Underlies Optimal Working Memory Performance
Zanto, T. P., & Gazzaley, A. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.4621-08.2009 · Cited by 302
“The time–frequency decomposition of the delay period was acquired via complex Morlet wavelets (family ratio: fo/ f 8) as implemented through EEGLAB (Delorme and Makeig, 2004).”
Assessing cortical network properties using TMS–EEG
Rogasch, N. C., & Fitzgerald, P. B. (2013) · Human Brain Mapping · doi:10.1002/hbm.22016 · Cited by 280
Occipital gamma activation during Vipassana meditation
Cahn, B. R., Delorme, A., & Polich, J. (2010) · Cognitive Processing · doi:10.1007/s10339-009-0352-1 · Cited by 300
“map plotting were performed using the EEGLAB Matlab software (Delorme and Makeig 2004; Delorme et al. 2007) and custom Matlab scripts.”
InfluentialExpectation and Attention in Hierarchical Auditory Prediction
Chennu, S., Noreika, V., Gueorguiev, D., Blenkmann, A., Kochen, S., Ibanez, A., Owen, A. M., & Bekinschtein, T. A. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.0114-13.2013 · Cited by 299
“These processing steps were implemented using custom MATLAB scripts that used EEGLAB functionality (Delorme and Makeig, 2004).”
MethodDebener, S., Makeig, S., Delorme, A., & Engel, A. K. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2004.09.006 · Cited by 287
“Independent component analysis (ICA) is a relatively new linear decomposition technique that can be regarded as refining the goal of PCA-based approaches to separate the observed EEG signals into both physiologically and behaviorally distinct components [8].”
BackgroundMethodInfluentialSelf-citationKlug, M., & Gramann, K. (2021) · European Journal of Neuroscience · doi:10.1111/ejn.14992 · Cited by 268
“The data were analyzed in MATLAB (R2016b version 9.1; The MathWorks Inc., Natick, Massachusetts, USA), using custom scripts based on the EEGLAB toolbox (Delorme & Makeig, 2004, version 14.1.0).”
MethodInfluentialElectrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Seperability of four-class motor imagery data using independent components analysis
Naeem, M., Brunner, C., Leeb, R., Graimann, B., & Pfurtscheller, G. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/003 · Cited by 295
Frequency-specific network connectivity increases underlie accurate spatiotemporal memory retrieval
Watrous, A. J., Tandon, N., Conner, C. R., Pieters, T., & Ekstrom, A. D. (2013) · Nature Neuroscience · doi:10.1038/nn.3315 · Cited by 296
Barbati, G., Porcaro, C., Zappasodi, F., Rossini, P. M., & Tecchio, F. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.015 · Cited by 293
Prestimulus Oscillatory Activity over Motor Cortex Reflects Perceptual Expectations
de Lange, F. P., Rahnev, D. A., Donner, T. H., & Lau, H. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1094-12.2013 · Cited by 268
“First, an infomax ICA algorithm (Delorme and Makeig, 2004) was used to decompose the signal into maximally independent sources, and components that were related to heartbeat and eyeblink artifacts were removed from the data.”
MethodMental stress assessment using simultaneous measurement of EEG and fNIRS
Al-Shargie, F., Kiguchi, M., Badruddin, N., Dass, S. C., Hani, A. F. M., & Tang, T. B. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003882 · Cited by 284
Comparing the Effects of Three Cognitive Tasks on Indicators of Mental Fatigue
Smith, M. R., Chai, R., Nguyen, H. T., Marcora, S. M., & Coutts, A. J. (2019) · The Journal of Psychology · doi:10.1080/00223980.2019.1611530 · Cited by 258
“Raw EEG data were imported into EEGLAB (Delorme & Makeig, 2004) using Matlab open source toolbox (Mathworks, Natick, USA) for visual inspection and rejection of artifacts.”
MethodKappenman, E. S., Farrens, J. L., Luck, S. J., & Proudfit, G. H. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.01368 · Cited by 266
“Signal processing and analysis was performed in Matlab using EEGLAB toolbox (Delorme and Makeig, 2004) and ERPLAB toolbox (Lopez-Calderon and Luck, 2014).”
MethodEEG applications for sport and performance
Thompson, T., Steffert, T., Ros, T., Leach, J., & Gruzelier, J. (2008) · Methods · doi:10.1016/j.ymeth.2008.07.006 · Cited by 260
Eye tracking and pupillometry are indicators of dissociable latent decision processes.
Cavanagh, J. F., Wiecki, T. V., Kochar, A., & Frank, M. J. (2014) · Journal of Experimental Psychology: General · doi:10.1037/a0035813 · Cited by 289
“Each epoch was then visually inspected by modifying the eeglab viewer (Delorme & Makeig, 2004) to display the time Figure 1.”
Decoding Attended Information in Short-term Memory: An EEG Study
LaRocque, J. J., Lewis-Peacock, J. A., Drysdale, A. T., Oberauer, K., & Postle, B. R. (2013) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00305 · Cited by 280
“The signal was then band-pass filtered between 1 and 55 Hz using EEGLAB.”
InfluentialTop-down control of the phase of alpha-band oscillations as a mechanism for temporal prediction
Samaha, J., Bauer, P., Cimaroli, S., & Postle, B. R. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1503686112 · Cited by 265
Schartner, M., Seth, A., Noirhomme, Q., Boly, M., Bruno, M.-A., Laureys, S., & Barrett, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0133532 · Cited by 287
“This filtering method was applied using MATLAB with BCIlab and EEGlab [44].”
MethodSingle-trial classification of vowel speech imagery using common spatial patterns
DaSalla, C. S., Kambara, H., Sato, M., & Koike, Y. (2009) · Neural Networks · doi:10.1016/j.neunet.2009.05.008 · Cited by 274
BOLD correlates of EEG alpha phase-locking and the fMRI default mode network
Jann, K., Dierks, T., Boesch, C., Kottlow, M., Strik, W., & Koenig, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.001 · Cited by 286
“One can therefore apply an independent component analysis (Extended Infomax ICA, EEGLAB Delorme and Makeig, 2004; Bell and Sejnowski, 1995) to decompose the measured signal into components that appear to be EEG, and components that appear to be artifacts (Jung et al., 2000a; Jung et al., 2000b).”
MethodSustained Neural Activity Patterns during Working Memory in the Human Medial Temporal Lobe
Axmacher, N., Mormann, F., Fernández, G., Cohen, M. X., Elger, C. E., & Fell, J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0962-07.2007 · Cited by 261
“Data were analyzed using the EEGLAB package created by A. Delorme and S. Makeig (Delorme and Makeig, 2004) run with Matlab (Mathworks, Natick, MA).”
MethodA Common Neural Mechanism for Preventing and Terminating the Allocation of Attention
Sawaki, R., Geng, J. J., & Luck, S. J. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.1864-12.2012 · Cited by 265
A wavelet-based technique to predict treatment outcome for Major Depressive Disorder
Mumtaz, W., Xia, L., Mohd Yasin, M. A., Azhar Ali, S. S., & Malik, A. S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171409 · Cited by 268
Faster Independent Component Analysis by Preconditioning With Hessian Approximations
Ablin, P., Cardoso, J.-F., & Gramfort, A. (2018) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2018.2844203 · Cited by 250
“EEGlab [13] or MNE [14]).”
Nair, A. K., Sasidharan, A., John, J. P., Mehrotra, S., & Kutty, B. M. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00001 · Cited by 281
Rellecke, J., Sommer, W., & Schacht, A. (2012) · Biological Psychology · doi:10.1016/j.biopsycho.2012.02.002 · Cited by 265
The effect of epoch length on estimated EEG functional connectivity and brain network organisation
Fraschini, M., Demuru, M., Crobe, A., Marrosu, F., Stam, C. J., & Hillebrand, A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036015 · Cited by 268
Fisch, L., Privman, E., Ramot, M., Harel, M., Nir, Y., Kipervasser, S., Andelman, F., Neufeld, M. Y., Kramer, U., Fried, I., et al. (2009) · Neuron · doi:10.1016/j.neuron.2009.11.001 · Cited by 275
Decoding of four movement directions using hybrid NIRS-EEG brain-computer interface
Khan, M. J., Hong, M. J., & Hong, K.-S. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00244 · Cited by 280
Aricò, P., Borghini, G., Di Flumeri, G., Colosimo, A., Bonelli, S., Golfetti, A., Pozzi, S., Imbert, J.-P., Granger, G., Benhacene, R., et al. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00539 · Cited by 249
“, ATCOs normally communicate verbally and perform several movements during their operational activity), specific procedures (Threshold criterion, Trend estimation, Sample-to-sample difference) available in the EEGLAB toolbox (Delorme and Makeig, 2004) have been applied.”
MethodEEG alpha spindle measures as indicators of driver fatigue under real traffic conditions
Simon, M., Schmidt, E. A., Kincses, W. E., Fritzsche, M., Bruns, A., Aufmuth, C., Bogdan, M., Rosenstiel, W., & Schrauf, M. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.10.044 · Cited by 268
Using EEG to Predict Consumers’ Future Choices
Telpaz, A., Webb, R., & Levy, D. J. (2015) · Journal of Marketing Research · doi:10.1509/jmr.13.0564 · Cited by 267
Reliability of Resting-State Microstate Features in Electroencephalography
Khanna, A., Pascual-Leone, A., & Farzan, F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0114163 · Cited by 249
Mars, R. B., Debener, S., Gladwin, T. E., Harrison, L. M., Haggard, P., Rothwell, J. C., & Bestmann, S. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2925-08.2008 · Cited by 264
“EEG data were analyzed using EEGLAB (Delorme and Makeig, 2004), implemented in Matlab 7.1.”
MethodInfluentialClinical evaluation of adhesively placed Cerec endo-crowns after 2 years--preliminary results.
Bindl, A., & MÖRMANN, W. H. (1999) · PubMed · Cited by 401
Karalunas, S. L., Geurts, H. M., Konrad, K., Bender, S., & Nigg, J. T. (2014) · Journal of Child Psychology and Psychiatry · doi:10.1111/jcpp.12217 · Cited by 278
Bae, G.-Y., & Luck, S. J. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.2860-17.2017 · Cited by 267
Learning From EEG Error-Related Potentials in Noninvasive Brain-Computer Interfaces
Chavarriaga, R., & Millan, J. D. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2053387 · Cited by 277
“preprocessing was done using the EEGLAB Matlab toolbox [25].”
MethodSmit, D. J. A., Stam, C. J., Posthuma, D., Boomsma, D. I., & de Geus, E. J. C. (2008) · Human Brain Mapping · doi:10.1002/hbm.20468 · Cited by 275
Emotion recognition using brain activity
Horlings, R., Datcu, D., & Rothkrantz, L. J. M. (2008) · Proceedings of the 9th International Conference on Computer Systems and Technologies and Workshop for PhD Students in Computing - CompSysTech '08 · doi:10.1145/1500879.1500888 · Cited by 262
“EEGLab [13] is a Matlab toolbox for processing and analyzing eeg and ecg data.”
MethodGrandy, T. H., Werkle‐Bergner, M., Chicherio, C., Schmiedek, F., Lövdén, M., & Lindenberger, U. (2013) · Psychophysiology · doi:10.1111/psyp.12043 · Cited by 276
Heart–brain interactions shape somatosensory perception and evoked potentials
Al, E., Iliopoulos, F., Forschack, N., Nierhaus, T., Grund, M., Motyka, P., Gaebler, M., Nikulin, V. V., & Villringer, A. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1915629117 · Cited by 276
“Data preprocessing EEG and ECG data were analyzed offline using EEGLAB (Delorme & Makeig, 2004) and FieldTrip (Oostenveld, Fries, Maris, & Schoffelen, 2011) toolbox algorithms as well as custom-built scripts on a Matlab platform (Mathworks Inc.).”
MethodPapadelis, C., Chen, Z., Kourtidou-Papadeli, C., Bamidis, P. D., Chouvarda, I., Bekiaris, E., & Maglaveras, N. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.031 · Cited by 268
Mu suppression – A good measure of the human mirror neuron system?
Hobson, H. M., & Bishop, D. V. M. (2016) · Cortex · doi:10.1016/j.cortex.2016.03.019 · Cited by 256
Steiger, T. K., & Bunzeck, N. (2017) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2017.00001 · Cited by 268
Ros, T., Théberge, J., Frewen, P. A., Kluetsch, R., Densmore, M., Calhoun, V. D., & Lanius, R. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.046 · Cited by 249
“Following EEG recording, all EEG data were imported into the Matlab toolbox EEGLAB v9 (Delorme and Makeig 2004).”
A conserved switch in sensory processing prepares developing neocortex for vision
Colonnese, M. T., Kaminska, A., Minlebaev, M., Milh, M., Bloem, B., Lescure, S., Moriette, G., Chiron, C., Ben-Ari, Y., & Khazipov, R. (2010) · Neuron · doi:10.1016/j.neuron.2010.07.015 · Cited by 273
The Correction of Eye Blink Artefacts in the EEG: A Comparison of Two Prominent Methods
Hoffmann, S., & Falkenstein, M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003004 · Cited by 261
A review of brain oscillations in perception of faces and emotional pictures
Güntekin, B., & Başar, E. (2014) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2014.03.014 · Cited by 258
The default mode network and EEG alpha oscillations: An independent component analysis
Knyazev, G. G., Slobodskoj-Plusnin, J. Y., Bocharov, A. V., & Pylkova, L. V. (2011) · Brain Research · doi:10.1016/j.brainres.2011.05.052 · Cited by 258
“Obtained independent components (ICs) are said to represent temporally independent signal sources and have scalp maps that nearly perfectly match the projection of a single equivalent brain dipole (Delorme and Makeig, 2004).”
BackgroundMultiway analysis of epilepsy tensors
Acar, E., Aykut-Bingol, C., Bingol, H., Bro, R., & Yener, B. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm210 · Cited by 267
Hippocampal sharp-wave ripples linked to visual episodic recollection in humans
Norman, Y., Yeagle, E. M., Khuvis, S., Harel, M., Mehta, A. D., & Malach, R. (2019) · Science · doi:10.1126/science.aax1030 · Cited by 270
“A. Delorme, S. Makeig, EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.”
InfluentialClayson, P. E., Baldwin, S. A., & Larson, M. J. (2013) · Psychophysiology · doi:10.1111/psyp.12001 · Cited by 249
Srivastava, G., Crottaz-Herbette, S., Lau, K. M., Glover, G. H., & Menon, V. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.041 · Cited by 264
“ICA was performed using the EEGLAB 4.1 software ( Delorme and Makeig, 2004 ).”
MethodInfluentialTinnitus Intensity Dependent Gamma Oscillations of the Contralateral Auditory Cortex
van der Loo, E., Gais, S., Congedo, M., Vanneste, S., Plazier, M., Menovsky, T., Van de Heyning, P., & De Ridder, D. (2009) · PLoS ONE · doi:10.1371/journal.pone.0007396 · Cited by 257
“EOG and EMG artifacts were removed in Matlab (The Mathworks, Natick, MA) using the automatic artifact removal toolbox in EEGLAB, using Blind Source Separation (BSS) (http:// sccn.ucsd.edu/eeglab/index.html) [37].”
Large-Scale Gamma-Band Phase Synchronization and Selective Attention
Doesburg, S. M., Roggeveen, A. B., Kitajo, K., & Ward, L. M. (2008) · Cerebral Cortex · doi:10.1093/cercor/bhm073 · Cited by 261
Beisteiner, R., Matt, E., Fan, C., Baldysiak, H., Schönfeld, M., Philippi Novak, T., Amini, A., Aslan, T., Reinecke, R., Lehrner, J., et al. (2020) · Advanced Science · doi:10.1002/advs.201902583 · Cited by 269
Brain waves for automatic biometric-based user recognition
Campisi, P., & La Rocca, D. (2014) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2014.2308640 · Cited by 264
Applying Principal Components Analysis to Event-Related Potentials: A Tutorial
Dien, J. (2012) · Developmental Neuropsychology · doi:10.1080/87565641.2012.697503 · Cited by 252
EEG Signatures of Dynamic Functional Network Connectivity States
Allen, E. A., Damaraju, E., Eichele, T., Wu, L., & Calhoun, V. D. (2018) · Brain Topography · doi:10.1007/s10548-017-0546-2 · Cited by 259
“Hereafter the EEG was re-referenced to a common average reference, segmented into 2 s epochs for each EPI volume acquisition, and subjected to an individual temporal ICA as implemented in EEGLAB to identify and remove residual pulse and eye movement artifacts from the data, retaining minimally 12 out of 30 components…”
A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Somers, B., Francart, T., & Bertrand, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac92 · Cited by 255
“We implemented the MWF in a user-friendly graphical user interface (GUI), in which the EEG channels are visualized using EEGLAB [8], allowing the user to assess spatial and temporal characteristics of features in the EEG.”
BackgroundMethodParallel Factor Analysis as an exploratory tool for wavelet transformed event-related EEG
Mørup, M., Hansen, L. K., Herrmann, C. S., Parnas, J., & Arnfred, S. M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.005 · Cited by 269
Walking through Architectural Spaces: The Impact of Interior Forms on Human Brain Dynamics
Banaei, M., Hatami, J., Yazdanfar, A., & Gramann, K. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00477 · Cited by 244
“EEG Data Preprocessing The analysis was done using open source EEGLAB toolbox2 (Delorme and Makeig, 2004) and custom MATLAB functions (The Mathworks, Inc.”
MethodHERMES: Towards an Integrated Toolbox to Characterize Functional and Effective Brain Connectivity
Niso, G., Bruña, R., Pereda, E., Gutiérrez, R., Bajo, R., Maestú, F., & Pozo Guerrero, F. D. (2013) · Archivo Digital UPM (Universidad Politécnica de Madrid) · Cited by 269
Common medial frontal mechanisms of adaptive control in humans and rodents
Narayanan, N. S., Cavanagh, J. F., Frank, M. J., & Laubach, M. (2013) · Nature Neuroscience · doi:10.1038/nn.3549 · Cited by 267
ElectroMagnetoEncephalography Software: Overview and Integration with Other EEG/MEG Toolboxes
Peyk, P., De Cesarei, A., & Junghöfer, M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/861705 · Cited by 261
“Here, a plug-in is described, which calls on FieldTrip routines to perform a time-frequency analysis on trial-bytrial EMEGS data, running through EEGLAB [15] for data conversion.”
MethodInfluentialAhn, S., Nguyen, T., Jang, H., Kim, J. G., & Jun, S. C. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00219 · Cited by 254
Composite Common Spatial Pattern for Subject-to-Subject Transfer
Kang, H., Nam, Y., & Choi, S. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2022557 · Cited by 265
Persistently active neurons in human medial frontal and medial temporal lobe support working memory
Kamiński, J., Sullivan, S., Chung, J. M., Ross, I. B., Mamelak, A. N., & Rutishauser, U. (2017) · Nature Neuroscience · doi:10.1038/nn.4509 · Cited by 264
Fu, H., Rodriguez, G. A., Herman, M., Emrani, S., Nahmani, E., Barrett, G., Figueroa, H. Y., Goldberg, E., Hussaini, S. A., & Duff, K. E. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.023 · Cited by 264
Visual activation of auditory cortex reflects maladaptive plasticity in cochlear implant users
Sandmann, P., Dillier, N., Eichele, T., Meyer, M., Kegel, A., Pascual-Marqui, R. D., Marcar, V. L., Jäncke, L., & Debener, S. (2012) · Brain · doi:10.1093/brain/awr329 · Cited by 259
“EEG data were analysed using EEGLAB (Delorme and Makeig, 2004) running in the MATLAB environment (Mathworks).”
MethodBrady, T. F., Störmer, V. S., & Alvarez, G. A. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1520027113 · Cited by 247
“Signal processing was performed with MATLAB (the MathWorks) using EEGLAB and ERPLAB toolboxes (48, 49).”
Saccadic spike potentials in gamma-band EEG: Characterization, detection and suppression
Keren, A. S., Yuval-Greenberg, S., & Deouell, L. Y. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.057 · Cited by 263
Attention induces synchronization-based response gain in steady-state visual evoked potentials
Joon Kim, Y., Grabowecky, M., Paller, K. A., Muthu, K., & Suzuki, S. (2007) · Nature Neuroscience · doi:10.1038/nn1821 · Cited by 261
“One way to evaluate whether attention increased neural response synchronization is to examine intertrial phase coherence (ITPC”
Assessing transient cross-frequency coupling in EEG data
Cohen, M. X. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.10.012 · Cited by 262
“All analyses were conducted in Matlab 6.5 using the signal processing and eeglab toolboxes, the latter of which is free to download (Delorme and Makeig, 2004), and supplemented by code written by the author.”
MethodInfluentialZhang, Z., Jung, T.-P., Makeig, S., & Rao, B. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2217959 · Cited by 263
Self-citationUpper limb movements can be decoded from the time-domain of low-frequency EEG
Ofner, P., Schwarz, A., Pereira, J., & Müller-Putz, G. R. (2017) · PLOS ONE · doi:10.1371/journal.pone.0182578 · Cited by 253
Acoustic Enhancement of Sleep Slow Oscillations and Concomitant Memory Improvement in Older Adults
Papalambros, N. A., Santostasi, G., Malkani, R. G., Braun, R., Weintraub, S., Paller, K. A., & Zee, P. C. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00109 · Cited by 259
Zhang, P., Wang, X., Zhang, W., & Chen, J. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2884641 · Cited by 249
“5 Hz to 40 Hz to remove the direct current component and high-frequency noises and then down-sampled at 256 Hz before additional processing in EEGLAB [38].”
MethodHeartbeat evoked potentials mirror altered body perception in depressed patients
Terhaar, J., Viola, F. C., Bär, K.-J., & Debener, S. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.02.086 · Cited by 236
Pearce, M. T., Ruiz, M. H., Kapasi, S., Wiggins, G. A., & Bhattacharya, J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.019 · Cited by 248
“We used the EEGLAB Matlab® Toolbox (Delorme and Makeig, 2004) for visualization and filtering purposes.”
Notbohm, A., Kurths, J., & Herrmann, C. S. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00010 · Cited by 241
“All analysis steps were performed in MATLAB R2012b (The MathWorks Inc., Natick, MA, USA) and EEGLAB 11.0.4.3 (Delorme and Makeig, 2004).”
MethodInfluentialVisually Induced Analgesia: Seeing the Body Reduces Pain
Longo, M. R., Betti, V., Aglioti, S. M., & Haggard, P. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.3072-09.2009 · Cited by 245
“EEG data were analyzed with EEGLAB (Delorme and Makeig, 2004) in Matlab 7.”
MethodInfluentialAlexander, M. L., Alagapan, S., Lugo, C. E., Mellin, J. M., Lustenberger, C., Rubinow, D. R., & Fröhlich, F. (2019) · Translational Psychiatry · doi:10.1038/s41398-019-0439-0 · Cited by 224
Waschke, L., Donoghue, T., Fiedler, L., Smith, S., Garrett, D. D., Voytek, B., & Obleser, J. (2021) · eLife · doi:10.7554/elife.70068 · Cited by 242
Frantzidis, C. A., Bratsas, C., Papadelis, C. L., Konstantinidis, E., Pappas, C., & Bamidis, P. D. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2041553 · Cited by 247
“The signals were offline preprocessed by using the MATLABbased EEGLAB tool [37].”
MethodHardmeier, M., Hatz, F., Bousleiman, H., Schindler, C., Stam, C. J., & Fuhr, P. (2014) · PLoS ONE · doi:10.1371/journal.pone.0108648 · Cited by 235
“Thereafter, the EEG was decomposed by independent component analysis (EEGLAB; [21]) and reconstructed after excluding components loading on the electro-cardiogramm, line noise in single electrodes or single gross artifacts; at maximum 5% of components were excluded.”
MethodError-related medial frontal theta activity predicts cingulate-related structural connectivity
Cohen, M. X. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.12.072 · Cited by 238
“Independent components analysis was computed using eeglab (Delorme and Makeig, 2004) software, and components containing blink/oculomotor artifacts or other artifacts that could be clearly distinguished from brain-driven EEG signals were subtracted from the data.”
InfluentialDetermination of awareness in patients with severe brain injury using EEG power spectral analysis
Goldfine, A. M., Victor, J. D., Conte, M. M., Bardin, J. C., & Schiff, N. D. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.03.022 · Cited by 240
The topography of alpha-band activity tracks the content of spatial working memory
Foster, J. J., Sutterer, D. W., Serences, J. T., Vogel, E. K., & Awh, E. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00860.2015 · Cited by 242
“To isolate frequency-specific activity, the raw EEG signal was bandpass filtered using a two-way leastsquares finite impulse response filter (“eegfilt.m” from EEGLAB Toolbox; see Delorme and Makeig 2004).”
MethodTime-frequency analysis methods and their application in developmental EEG data
Morales, S., & Bowers, M. E. (2022) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2022.101067 · Cited by 220
“This quick search illustrates that even though TF analyses have been available to the EEG research community for several years (Delorme and Makeig, 2004), are widely used in the cognitive neuroscience literature, and there have been previous calls for the benefits of TF analyses on developmental…”
InfluentialHuman brain connectivity during single and paired pulse transcranial magnetic stimulation
Ferreri, F., Pasqualetti, P., Määttä, S., Ponzo, D., Ferrarelli, F., Tononi, G., Mervaala, E., Miniussi, C., & Rossini, P. M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.056 · Cited by 250
“Topographic head plots of cortical evoked activity were obtained by EEGLAB toolbox (Delorme and Makeig, 2004).”
InfluentialCalabrò, R. S., Naro, A., Russo, M., Leo, A., De Luca, R., Balletta, T., Buda, A., La Rosa, G., Bramanti, A., & Bramanti, P. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0268-4 · Cited by 249
“3, spectra deviating from the mean by ±50 dB in the 0-2 Hz frequency window and by [−100;50]dB in the 20-100 Hz frequency window), visually inspection for artifacts, and if the power perturbation in the 20–40 Hz band deviated by +25 or -100 dB from the baseline at least for one IC [57, 60].”
BackgroundMethodMinzenberg, M. J., Firl, A. J., Yoon, J. H., Gomes, G. C., Reinking, C., & Carter, C. S. (2010) · Neuropsychopharmacology · doi:10.1038/npp.2010.150 · Cited by 247
“The remaining data were then imported into EEGLab (Delorme and Makeig, 2004), re-referenced against the average reference, downsampled to 250 Hz and high-pass filtered at 0.”
Influential
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.