EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
We have developed a toolbox and graphic user interface, EEGLAB, running under the crossplatform MATLAB environment (The Mathworks, Inc.) for processing collections of single-trial and/or averaged EEG data of any number of channels. Available functions include EEG data, channel and event information importing, data visualization (scrolling, scalp map and dipole model plotting, plus multi-trial ERP-image plots), preprocessing (including artifact rejection, filtering, epoch selection, and averaging), independent component analysis (ICA) and time/frequency decompositions including channel and component cross-coherence supported by bootstrap statistical methods based on data resampling. EEGLAB functions are organized into three layers. Top-layer functions allow users to interact with the data through the graphic interface without needing to use MATLAB syntax. Menu options allow users to tune the behavior of EEGLAB to available memory. Middle-layer functions allow users to customize data processing using command history and interactive 'pop' functions. Experienced MATLAB users can use EEGLAB data structures and stand-alone signal processing functions to write custom and/or batch analysis scripts. Extensive function help and tutorial information are included. A 'plug-in' facility allows easy incorporation of new EEG modules into the main menu. EEGLAB is freely available (http://www.sccn.ucsd.edu/eeglab/) under the GNU public license for noncommercial use and open source development, together with sample data, user tutorial and extensive documentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Through the above optimization methods, the model proposed in this paper outperforms other similar studies mentioned above in the classification tasks of DEAP and MAHNOB-HCI datasets.”
From Multimodal Emotion Recognition From EEG Signals and Facial Expressions (2023) · cites this paper as [30]
Experimental — accuracy not yet measuredIn the citing paper
“The artifacts caused by eye blinks and movements were corrected by applying the independent component analysis (ICA) algorithm in the Fieldtrip toolbox (Delorme and Makeig, 2004).”
From Neural Signatures of Hierarchical Linguistic Structures in Second Language Listening Comprehension (2023) · cites this paper as Delorme and Makeig, 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“To compensate for multiple comparisons, significance thresholds may need to be decreased (e.g. Bonferroni, 1950; Holm, 1979).”
BackgroundAn Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986 · cited 1×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive…”
MethodIndependent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705 · cited 1×
“The toolbox also allows the user to select any of over 20 available ICA algorithms including JADE (Cardoso and Souloumiac, 1993) and fixed-point ICA (Hyvarinen and Oja, 2000).”
MethodSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 2×
“These interactive functions, called ‘pop’ functions, work in two modes.”
BackgroundRemoving electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334 · cited 4×
“ICA algorithms have proven capable of isolating both artifactual and neurally generated EEG sources (Makeig et al., 1999; Jung et al., 2000) whose EEG contributions, across the training data, are maximally independent of one another.”
BackgroundMethodInfluentialSelf-citationBlind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Self-citationLee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967 · cited 4×
“EEGLAB contains an automated version, runica() (Makeig, 1997), of the infomax ICA algorithm (Bell and Sejnowski, 1995) with several enhancements (Amari et al., 1996; Lee et al., 1999) both as a Matlab function and as a stand-alone binary C program that allows faster and less memory-intensive computation.”
MethodInfluentialPerception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915 · cited 2×
“, 1999) and with visual awareness (Rodriguez et al., 1999).”
Background
Research works printed but not linked: 3
- Baillet S, Mosher JC, Leahy RM, Shattuck DW. BrainStorm: a Matlab Toolbox for the Processing of MEG and EEG Signals. Proceedings of the 5th Int. Conf. on Human Brain Map., Neuroimage, 1999; 9: 246.
- Duann JR, Jung TP, Kuo WJ, Yeh TC, Makeig S, Hsieh JC, Sejnowski TJ. Single-trial variability in event-related BOLD signals. Neuroimage, 2002b; 15: 823-35. · DOI · Paper page
- Jung TP, Makeig S, Westerfield M, Townsend J, Courchesne E, Sejnowski TJ. Analyzing and Visualizing Single-trial Eventrelated Potentials. Adv. Neural Inf. Process. Syst., 1999; 11: 11824.
Cited by
Items 101–200 of 1,311
Cortical network functional connectivity in the descent to sleep
Larson-Prior, L. J., Zempel, J. M., Nolan, T. S., Prior, F. W., Snyder, A. Z., & Raichle, M. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900924106 · Cited by 450
Gaillard, R., Naccache, L., Pinel, P., Clémenceau, S., Volle, E., Hasboun, D., Dupont, S., Baulac, M., Dehaene, S., Adam, C., et al. (2006) · Neuron · doi:10.1016/j.neuron.2006.03.031 · Cited by 439
“Epochs were then low-pass filtered (20 Hz) using EEGLab software ( Delorme and Makeig, 2004 ).”
MethodNeural Substrate of the Late Positive Potential in Emotional Processing
Liu, Y., Huang, H., McGinnis-Deweese, M., Keil, A., & Ding, M. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3109-12.2012 · Cited by 413
“These data were then exported to the EEGLAB (Delorme and Makeig, 2004).”
MethodConverging Intracranial Markers of Conscious Access
Gaillard, R., Dehaene, S., Adam, C., Clémenceau, S., Hasboun, D., Baulac, M., Cohen, L., & Naccache, L. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000061 · Cited by 440
“For the remaining 147 electrodes, we used the ‘newtimef’ and ‘newcrossf’ functions of EEGLAB software [90] to estimate and plot, respectively, the mean event-related (log) spectral perturbation (ERSP) and ITC around word onset.”
MethodAn electrophysiological marker of arousal level in humans
Lendner, J. D., Helfrich, R. F., Mander, B. A., Romundstad, L., Lin, J. J., Walker, M. P., Larsson, P. G., & Knight, R. T. (2020) · eLife · doi:10.7554/elife.55092 · Cited by 410
Coordination of Locomotion with Voluntary Movements in Humans
Ivanenko, Y. P., Cappellini, G., Dominici, N., Poppele, R. E., & Lacquaniti, F. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1327-05.2005 · Cited by 427
“edu/eeglab/) (Delorme and Makeig, 2004) running on Matlab version 7.”
MethodInfluentialLight, G. A., Hsu, J. L., Hsieh, M. H., Meyer-Gomes, K., Sprock, J., Swerdlow, N. R., & Braff, D. L. (2006) · Biological Psychiatry · doi:10.1016/j.biopsych.2006.03.055 · Cited by 422
Increased Brain Signal Variability Accompanies Lower Behavioral Variability in Development
McIntosh, A. R., Kovacevic, N., & Itier, R. J. (2008) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000106 · Cited by 431
“Preliminary artifact removal was performed using independent component analysis (ICA) as implemented in EEGLAB software [48].”
MethodSingle-trial EEG–fMRI reveals the dynamics of cognitive function
Debener, S., Ullsperger, M., Siegel, M., & Engel, A. K. (2006) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2006.09.010 · Cited by 428
Zaehle, T., Sandmann, P., Thorne, J. D., Jäncke, L., & Herrmann, C. S. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-2 · Cited by 407
Marín-Morales, J., Higuera-Trujillo, J. L., Greco, A., Guixeres, J., Llinares, C., Scilingo, E. P., Alcañiz, M., & Valenza, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-32063-4 · Cited by 411
Lost in thoughts: Neural markers of low alertness during mind wandering
Braboszcz, C., & Delorme, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.008 · Cited by 425
“For short threesecond epochs time-locked to auditory stimuli presentation, we also removed baseline spectral activity by subtracting the pre-stimulus average baseline log-power at each frequency (Delorme and Makeig 2004) .”
MethodInfluentialA multimodal approach to estimating vigilance using EEG and forehead EOG
Zheng, W.-L., & Lu, B.-L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a98 · Cited by 424
“ICA is a blind source separation method proposed to decompose a multivariate signal into independent non-Gaussian signals (Delorme & Makeig 2004).”
MethodStefanics, G., Hangya, B., Hernádi, I., Winkler, I., Lakatos, P., & Ulbert, I. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.0703-10.2010 · Cited by 408
Voytek, B. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00191 · Cited by 406
Broderick, M. P., Anderson, A. J., Di Liberto, G. M., Crosse, M. J., & Lalor, E. C. (2018) · Current Biology · doi:10.1016/j.cub.2018.01.080 · Cited by 421
Philiastides, M. G., Ratcliff, R., & Sajda, P. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.1655-06.2006 · Cited by 399
“All scalp maps were plotted using EEGLAB (Delorme and Makeig, 2004).”
MethodInformation-based modeling of event-related brain dynamics
Onton, J., & Makeig, S. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59007-7 · Cited by 386
Self-citationBCILAB: a platform for brain–computer interface development
Kothe, C. A., & Makeig, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056014 · Cited by 412
“This is represented as a backwards-compatible extension of the EEGLAB dataset structure (data plus arbitrary metadata) [40].”
MethodSelf-citationRogasch, N. C., Sullivan, C., Thomson, R. H., Rose, N. S., Bailey, N. W., Fitzgerald, P. B., Farzan, F., & Hernandez-Pavon, J. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.031 · Cited by 411
“To address the need for open-source TMS–EEG analysis, we introduce an extension called the TMS–EEG signal analyser (TESA), which is implemented in the open-source EEG analysis software EEGLAB (Delorme and Makeig, 2004) on the Matlab platform (Mathworks).”
InfluentialTian, L., Zimmerman, B., Akhtar, A., Yu, K. J., Moore, M., Wu, J., Larsen, R. J., Lee, J. W., Li, J., Liu, Y., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0347-x · Cited by 393
Plöchl, M., Ossandón, J. P., & König, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00278 · Cited by 372
Adaptive deep brain stimulation for Parkinson’s disease using motor cortex sensing
Swann, N. C., de Hemptinne, C., Thompson, M. C., Miocinovic, S., Miller, A. M., Gilron, R., Ostrem, J. L., Chizeck, H. J., & Starr, P. A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aabc9b · Cited by 389
Interpersonal body and neural synchronization as a marker of implicit social interaction
Yun, K., Watanabe, K., & Shimojo, S. (2012) · Scientific Reports · doi:10.1038/srep00959 · Cited by 379
The Neural Code of Auditory Phantom Perception
Weisz, N., Müller, S., Schlee, W., Dohrmann, K., Hartmann, T., & Elbert, T. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3711-06.2007 · Cited by 394
Motivation and cognitive control in depression
Grahek, I., Shenhav, A., Musslick, S., Krebs, R. M., & Koster, E. H. W. (2019) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2019.04.011 · Cited by 348
Frontal theta EEG activity correlates negatively with the default mode network in resting state
Scheeringa, R., Bastiaansen, M. C. M., Petersson, K. M., Oostenveld, R., Norris, D. G., & Hagoort, P. (2008) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.05.017 · Cited by 400
“ICAwas carried out inthe Fieldtriptoolbox for EEG/MEG-analysis (FCDonders Centre for Cognitive Neuroimaging, Nijmegen, The Netherlands; seehttp://www.ru.nl/fcdonders/fieldtrip), using the runica algorithm (Makeig et al., 1997) implemented in EEGLAB version 5.03 ( Delorme and Makeig, 2004 ).”
MethodInfluentialShort, C. E., DeSmet, A., Woods, C., Williams, S. L., Maher, C., Middelweerd, A., Müller, A. M., Wark, P. A., Vandelanotte, C., Poppe, L., et al. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9397 · Cited by 400
“Using this method requires adequate expertise, both in terms of measurement [129] and analysis [130] of data.”
MethodWulff, P., Ponomarenko, A. A., Bartos, M., Korotkova, T. M., Fuchs, E. C., Bähner, F., Both, M., Tort, A. B. L., Kopell, N. J., Wisden, W., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813176106 · Cited by 400
Consciousness and Complexity during Unresponsiveness Induced by Propofol, Xenon, and Ketamine
Sarasso, S., Boly, M., Napolitani, M., Gosseries, O., Charland-Verville, V., Casarotto, S., Rosanova, M., Casali, A. G., Brichant, J.-F., Boveroux, P., et al. (2015) · Current Biology · doi:10.1016/j.cub.2015.10.014 · Cited by 399
Validation of the Emotiv EPOC ® EEG gaming system for measuring research quality auditory ERPs
Badcock, N. A., Mousikou, P., Mahajan, Y., de Lissa, P., Thie, J., & McArthur, G. (2013) · PeerJ · doi:10.7717/peerj.38 · Cited by 397
“During offline processing, the research EEG system data was downsampled (using EEGLAB; Delorme & Makeig, 2004) to 128 Hz to make it compatible with the gaming EEG system sample rate.”
MethodInfluentialNorton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Scheeringa, R., Petersson, K. M., Oostenveld, R., Norris, D. G., Hagoort, P., & Bastiaansen, M. C. M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.041 · Cited by 359
EEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
Linking brain, mind and behavior
Makeig, S., Gramann, K., Jung, T.-P., Sejnowski, T. J., & Poizner, H. (2009) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2008.11.008 · Cited by 390
Self-citationUnobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear
Debener, S., Emkes, R., De Vos, M., & Bleichner, M. (2015) · Scientific Reports · doi:10.1038/srep16743 · Cited by 382
Gola, M., Magnuski, M., Szumska, I., & Wróbel, A. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.05.007 · Cited by 362
Babayan, A., Erbey, M., Kumral, D., Reinelt, J. D., Reiter, A. M. F., Röbbig, J., Schaare, H. L., Uhlig, M., Anwander, A., Bazin, P.-L., et al. (2019) · Scientific Data · doi:10.1038/sdata.2018.308 · Cited by 364
Dmochowski, J. P., Sajda, P., Dias, J., & Parra, L. C. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00112 · Cited by 362
Early detection of consciousness in patients with acute severe traumatic brain injury
Edlow, B. L., Chatelle, C., Spencer, C. A., Chu, C. J., Bodien, Y. G., O’Connor, K. L., Hirschberg, R. E., Hochberg, L. R., Giacino, J. T., Rosenthal, E. S., et al. (2017) · Brain · doi:10.1093/brain/awx176 · Cited by 376
Regional brain wave activity changes associated with fatigue
Craig, A., Tran, Y., Wijesuriya, N., & Nguyen, H. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01329.x · Cited by 359
Koch, G., Bonnì, S., Pellicciari, M. C., Casula, E. P., Mancini, M., Esposito, R., Ponzo, V., Picazio, S., Di Lorenzo, F., Serra, L., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.048 · Cited by 367
The motor cortex drives the muscles during walking in human subjects
Petersen, T. H., Willerslev‐Olsen, M., Conway, B. A., & Nielsen, J. B. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.227397 · Cited by 358
“This was performed in the EEG-LAB scroll viewer (Delorme & Makeig, 2004).”
MethodClassification of patterns of EEG synchronization for seizure prediction
Mirowski, P., Madhavan, D., LeCun, Y., & Kuzniecky, R. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.09.002 · Cited by 380
“We further applied Infinite Impulse Response (IIR) elliptical filters , using code from EEGLab (Delorme and Makeig, 2004) to clean some artifacts: a 49–51Hz band-reject 12th-order filter to remove power line noise, a 120 Hz cutoff low-pass 1st-order filter, and a 0.5 Hz cutoff high-pass 5th-order filter to remove the…”
InfluentialGrandchamp, R., & Delorme, A. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00236 · Cited by 355
Tanner, D., Morgan‐Short, K., & Luck, S. J. (2015) · Psychophysiology · doi:10.1111/psyp.12437 · Cited by 354
The classic P300 encodes a build‐to‐threshold decision variable
Twomey, D. M., Murphy, P. R., Kelly, S. P., & O'Connell, R. G. (2015) · European Journal of Neuroscience · doi:10.1111/ejn.12936 · Cited by 376
“Data were analysed using custom scripts in MATLAB (Mathworks, Natick, MA, USA), drawing on EEGLAB (Delorme & Makeig, 2004) routines for reading in data files and spherical spline interpolation of noisy channels.”
MethodFrequency-Band Coupling in Surface EEG Reflects Spiking Activity in Monkey Visual Cortex
Whittingstall, K., & Logothetis, N. K. (2009) · Neuron · doi:10.1016/j.neuron.2009.08.016 · Cited by 363
Blind Source Separation and Independent Component Analysis: A Review
Lee, S.-Y. (2005) · International Conference on Neural Information Processing · Cited by 374
Semi-automatic identification of independent components representing EEG artifact
Campos Viola, F., Thorne, J., Edmonds, B., Schneider, T., Eichele, T., & Debener, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.015 · Cited by 364
Evaluation of Artifact Subspace Reconstruction for Automatic EEG Artifact Removal
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512547 · Cited by 335
Nociceptive Laser-Evoked Brain Potentials Do Not Reflect Nociceptive-Specific Neural Activity
Mouraux, A., & Iannetti, G. D. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91181.2008 · Cited by 373
Delta–Beta Coupled Oscillations Underlie Temporal Prediction Accuracy
Arnal, L. H., Doelling, K. B., & Poeppel, D. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhu103 · Cited by 357
“EEGlab (Delorme and Makeig 2004) packages, and additional programs developed in MATLAB (The MathWorks, Natick MA).”
MethodInfluentialSingle-Trial Regression Elucidates the Role of Prefrontal Theta Oscillations in Response Conflict
Cohen, M. X., & Cavanagh, J. F. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00030 · Cited by 343
Electroencephalographic Brain Dynamics Following Manually Responded Visual Targets
Makeig, S., Delorme, A., Westerfield, M., Jung, T.-P., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020176 · Cited by 357
Self-citationPersistent EEG overactivation in the cortical pain matrix of neurogenic pain patients
Stern, J., Jeanmonod, D., & Sarnthein, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.042 · Cited by 334
“MA) using EEGLAB (http://www.sccn.ucsd.edu/eeglab/ index.html )( Delorme and Makeig, 2004 ) and custom scripts.”
MethodKäthner, I., Wriessnegger, S. C., Müller-Putz, G. R., Kübler, A., & Halder, S. (2014) · Biological Psychology · doi:10.1016/j.biopsycho.2014.07.014 · Cited by 328
“Offline data analysis The EEG was analyzed with Matlab (version R2012b) in combination with the EEGLab and ERPLab toolboxes (version 10.2.2.4b; Delorme & Makeig, 2004).”
InfluentialReconstructing Three-Dimensional Hand Movements from Noninvasive Electroencephalographic Signals
Bradberry, T. J., Gentili, R. J., & Contreras-Vidal, J. L. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.6107-09.2010 · Cited by 360
Smith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
Real-Time Movie-Induced Discrete Emotion Recognition from EEG Signals
Liu, Y.-J., Yu, M., Zhao, G., Song, J., Ge, Y., & Shi, Y. (2018) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2660485 · Cited by 356
“To incorporate more powerful signal processing, feature extraction and machine learning algorithms, we build a buffer to store the EEG data stream from the Emotiv EPOC and then load the EEG data section by section in EEGLAB, which is an open source Matlab toolbox for physiological signal processing [32].”
MethodEEG-based workers' stress recognition at construction sites
Jebelli, H., Hwang, S., & Lee, S. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.05.027 · Cited by 339
How many trials does it take to get a significant ERP effect? It depends
Boudewyn, M. A., Luck, S. J., Farrens, J. L., & Kappenman, E. S. (2018) · Psychophysiology · doi:10.1111/psyp.13049 · Cited by 323
Moore, A., Gruber, T., Derose, J., & Malinowski, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00018 · Cited by 317
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
“We provide the ready-to-use artifact classifier to the community as an open-source EEGLAB plug-in called MARA (multiple artifact rejection algorithm).”
MethodInfluentialZhang, Z. G., Hu, L., Hung, Y. S., Mouraux, A., & Iannetti, G. D. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.5877-11.2012 · Cited by 332
“Trials contaminated by eye-blinks and movements were corrected using an independent component analysis (ICA) algorithm (Makeig et al., 1997; Jung et al., 2001; Delorme and Makeig, 2004).”
InfluentialIeracitano, C., Mammone, N., Hussain, A., & Morabito, F. C. (2020) · Neural Networks · doi:10.1016/j.neunet.2019.12.006 · Cited by 329
Miltiadous, A., Tzimourta, K. D., Afrantou, T., Ioannidis, P., Grigoriadis, N., Tsalikakis, D. G., Angelidis, P., Tsipouras, M. G., Glavas, E., Giannakeas, N., et al. (2023) · Data · doi:10.3390/data8060095 · Cited by 283
“Making the dataset BIDS compatible ensures the ease of use for other researchers because open-source software (such as EEGLAB [18]) provide tools for analyzing and processing neuroimaging data of BIDS-compliant datasets.”
MethodTensor decomposition of EEG signals: A brief review
Cong, F., Lin, Q.-H., Kuang, L.-D., Gong, X.-F., Astikainen, P., & Ristaniemi, T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.03.018 · Cited by 334
Oddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332
Lithari, C., Frantzidis, C. A., Papadelis, C., Vivas, A. B., Klados, M. A., Kourtidou-Papadeli, C., Pappas, C., Ioannides, A. A., & Bamidis, P. D. (2010) · Brain Topography · doi:10.1007/s10548-009-0130-5 · Cited by 311
Chennu, S., Annen, J., Wannez, S., Thibaut, A., Chatelle, C., Cassol, H., Martens, G., Schnakers, C., Gosseries, O., Menon, D., et al. (2017) · Brain · doi:10.1093/brain/awx163 · Cited by 339
High Gamma Activity in Response to Deviant Auditory Stimuli Recorded Directly From Human Cortex
Edwards, E., Soltani, M., Deouell, L. Y., Berger, M. S., & Knight, R. T. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00324.2005 · Cited by 333
Swann, N. C., de Hemptinne, C., Miocinovic, S., Qasim, S., Wang, S. S., Ziman, N., Ostrem, J. L., San Luciano, M., Galifianakis, N. B., & Starr, P. A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.1128-16.2016 · Cited by 322
“Analyses were performed in Matlab using a combination of built-in Matlab functions, EEGlab functions (Delorme and Makeig, 2004), and custom functions/scripts.”
MethodSelective Modulation of Interhemispheric Functional Connectivity by HD-tACS Shapes Perception
Helfrich, R. F., Knepper, H., Nolte, G., Strüber, D., Rach, S., Herrmann, C. S., Schneider, T. R., & Engel, A. K. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1002031 · Cited by 320
Johnson, J. S., Sutterer, D. W., Acheson, D. J., Lewis-Peacock, J. A., & Postle, B. R. (2011) · Frontiers in Psychology · doi:10.3389/fpsyg.2011.00128 · Cited by 326
“Data were acquired at a sampling rate of 1450 Hz, and were band pass filtered (0.1–100 Hz) and down sampled to 500 Hz offline using the EEGlab toolbox (Delorme and Makeig, 2004) running in a MATLAB environment (Mathworks, Natick, MA, USA).”
MethodInfluentialFrontal Theta Reflects Uncertainty and Unexpectedness during Exploration and Exploitation
Cavanagh, J. F., Figueroa, C. M., Cohen, M. X., & Frank, M. J. (2012) · Cerebral Cortex · doi:10.1093/cercor/bhr332 · Cited by 291
Wessel, J. R. (2018) · Psychophysiology · doi:10.1111/psyp.12871 · Cited by 306
Evaluating two-step PCA of ERP data with Geomin, Infomax, Oblimin, Promax, and Varimax rotations
Dien, J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00885.x · Cited by 302
Montez, T., Poil, S.-S., Jones, B. F., Manshanden, I., Verbunt, J. P. A., van Dijk, B. W., Brussaard, A. B., van Ooyen, A., Stam, C. J., Scheltens, P., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0811699106 · Cited by 315
Spontaneous Neural Oscillations Bias Perception by Modulating Baseline Excitability
Iemi, L., Chaumon, M., Crouzet, S. M., & Busch, N. A. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.1432-16.2016 · Cited by 287
“The EEGLAB toolbox version 11 running on MATLAB (R2010b; The MathWorks) was used to process and analyze the data (Delorme and Makeig, 2004).”
MethodWhen brain rhythms aren't ‘rhythmic’: implication for their mechanisms and meaning
Jones, S. R. (2016) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2016.06.010 · Cited by 296
“The latter could also be reflected as inter-trial phase coherence [42,43], which some studies have associated with the resetting of ongoing oscillations [44–46].”
BackgroundThe amplitude of the resting-state fMRI global signal is related to EEG vigilance measures
Wong, C. W., Olafsson, V., Tal, O., & Liu, T. T. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.057 · Cited by 318
“Independent components (ICs) corresponding to residual BCG or eye blinking artifacts were identified by correlating all IC topographies with artifact template topographies and extracting the ICswith spatial correlation values of 0.8 or more (Debener et al., 2007; Viola et al., 2009).”
MethodInfluentialClassifying Different Emotional States by Means of EEG-Based Functional Connectivity Patterns
Lee, Y.-Y., & Hsieh, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095415 · Cited by 301
“EEGLAB, an open-source toolbox for analysis of single-trial EEG dynamics, was used in this research [39].”
MethodEEG oscillations and recognition memory: Theta correlates of memory retrieval and decision making
Jacobs, J., Hwang, G., Curran, T., & Kahana, M. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.018 · Cited by 306
“Topographic plots were created with the topoplot function from EEGLAB (Delorme and Makeig, 2004).”
MethodValidating γ oscillations and delayed auditory responses as translational biomarkers of autism
Gandal, M. J., Edgar, J. C., Ehrlichman, R. S., Mehta, M., Roberts, T. P. L., & Siegel, S. J. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2010.09.031 · Cited by 314
Theta EEG dynamics of the error-related negativity
Trujillo, L. T., & Allen, J. J. B. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.11.009 · Cited by 314
“These scalp amplitude distributions were displayed using an algorithm adapted from the EEGLAB toolbox (Delorme and Makeig, 2004) for the Matlab computing software.”
BackgroundMethodHERMES: Towards an Integrated Toolbox to Characterize Functional and Effective Brain Connectivity
Niso, G., Bruña, R., Pereda, E., Gutiérrez, R., Bajo, R., Maestú, F., & del-Pozo, F. (2013) · Neuroinformatics · doi:10.1007/s12021-013-9186-1 · Cited by 281
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Self-citationBevilacqua, D., Davidesco, I., Wan, L., Chaloner, K., Rowland, J., Ding, M., Poeppel, D., & Dikker, S. (2019) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01274 · Cited by 312
“We first set a rejection threshold in EEGLAB of ±100 μ V for all channels and then visually inspected each 1-sec epoch to further exclude eye, muscle, and speech-related artifacts.”
Deep Convolutional Neural Network Model for Automated Diagnosis of Schizophrenia Using EEG Signals
Oh, S. L., Vicnesh, J., Ciaccio, E. J., Yuvaraj, R., & Acharya, U. R. (2019) · Applied Sciences · doi:10.3390/app9142870 · Cited by 304
Barttfeld, P., Wicker, B., Cukier, S., Navarta, S., Lew, S., & Sigman, M. (2011) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2010.11.024 · Cited by 311
Rhythmic Fluctuations in Evidence Accumulation during Decision Making in the Human Brain
Wyart, V., de Gardelle, V., Scholl, J., & Summerfield, C. (2012) · Neuron · doi:10.1016/j.neuron.2012.09.015 · Cited by 278
Very high density EEG elucidates spatiotemporal aspects of early visual processing
Robinson, A. K., Venkatesh, P., Boring, M. J., Tarr, M. J., Grover, P., & Behrmann, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-16377-3 · Cited by 302
“EEG data analysis was performed offline using EEGlab (Delorme & Makeig, 2004).”
MethodRogasch, N. C., Thomson, R. H., Farzan, F., Fitzgibbon, B. M., Bailey, N. W., Hernandez-Pavon, J. C., Daskalakis, Z. J., & Fitzgerald, P. B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.037 · Cited by 309
Ieracitano, C., Mammone, N., Bramanti, A., Hussain, A., & Morabito, F. C. (2019) · Neurocomputing · doi:10.1016/j.neucom.2018.09.071 · Cited by 294
Automagic: Standardized preprocessing of big EEG data
Pedroni, A., Bahreini, A., & Langer, N. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.046 · Cited by 292
Eichele, T., Specht, K., Moosmann, M., Jongsma, M. L. A., Quiroga, R. Q., Nordby, H., & Hugdahl, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505508102 · Cited by 308
LIMO EEG: A Toolbox for Hierarchical LInear MOdeling of ElectroEncephaloGraphic Data
Pernet, C. R., Chauveau, N., Gaspar, C., & Rousselet, G. A. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/831409 · Cited by 303
“…et Handicaps Neurologiques UMR 825, 31059 Toulouse, France 4 Centre for Cognitive Neuroimaging (CCNi), Institute of Neuroscience and Psychology, University of Glasgow, Glasgow G12 8QB, UK Correspondence should be addressed to Cyril R. Pernet, cyril.pernet@ed.ac.uk Received 21 September 2010;…”
BackgroundInfluentialWearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Wagner, J., Solis-Escalante, T., Grieshofer, P., Neuper, C., Müller-Putz, G., & Scherer, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.019 · Cited by 301
Metadata
- Authors
- Delorme, A., & Makeig, S.
- Affiliations
- University of California San Diego (US)
- ORCID
- Makeig, Scott
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 134
- Issue
- 1
- Pages
- 9-21
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2128495200
- Cited by
- 24,371
- References
- 39
- Citations by year
- 2026: 1965 · 2025: 2472 · 2024: 2191 · 2023: 2114 · 2022: 1984 · 2021: 1999 · 2020: 1784 · 2019: 1662 · 2018: 1378 · 2017: 1260 · 2016: 1022 · 2015: 921 · 2014: 766 · 2013: 683 · 2012: 515
- FWCI
- 62.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- EEGLAB, single-trial EEG, independent component analysis, event-related potentials, EEG preprocessing, artifact rejection, time-frequency decomposition, cross-coherence, bootstrapping, dipole modeling, open source software, MATLAB toolbox
- MeSH terms
- Computer Simulation, Electroencephalography, Evoked Potentials, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.