The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Temporal classification of multichannel near-infrared spectroscopy signals of motor imagery for developing a brain–computer interface
Open accessAbstract
There has been an increase in research interest for brain-computer interface (BCI) technology as an alternate mode of communication and environmental control for the disabled, such as patients suffering from amyotrophic lateral sclerosis (ALS), brainstem stroke and spinal cord injury. Disabled patients with appropriate physical care and cognitive ability to communicate with their social environment continue to live with a reasonable quality of life over extended periods of time. Near-infrared spectroscopy is a non-invasive technique which utilizes light in the near-infrared range (700 to 1000 nm) to determine cerebral oxygenation, blood flow and metabolic status of localized regions of the brain. In this paper, we describe a study conducted to test the feasibility of using multichannel NIRS in the development of a BCI. We used a continuous wave 20-channel NIRS system over the motor cortex of 5 healthy volunteers to measure oxygenated and deoxygenated hemoglobin changes during left-hand and right-hand motor imagery. We present results of signal analysis indicating that there exist distinct patterns of hemodynamic responses which could be utilized in a pattern classifier towards developing a BCI. We applied two different pattern recognition algorithms separately, Support Vector Machines (SVM) and Hidden Markov Model (HMM), to classify the data offline. SVM classified left-hand imagery from right-hand imagery with an average accuracy of 73% for all volunteers, while HMM performed better with an average accuracy of 89%. Our results indicate potential application of NIRS in the development of BCIs. We also discuss here future extension of our system to develop a word speller application based on a cursor control paradigm incorporating online pattern classification of single-trial NIRS data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationFundamentals of speech recognition
Rabiner, L. R., & Juang, B.-H. F. (1993) · Cited by 7,680
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Self-citationEstimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks
Pfurtscheller, G., Brunner, C., Schlögl, A., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.003 · Cited by 1,587
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Self-citationControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
fNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
A quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
Zander, T. O., & Kothe, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025005 · Cited by 887
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Cui, X., Bryant, D. M., & Reiss, A. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.003 · Cited by 807
“NIRS is a relatively flexible technology and to date has been successfully applied in several domains [22], including physiological mechanisms of the BOLD response [23-31], non-invasive brain-computer interfaces [32-36], and brain activity in both active tasks and resting states [37-42].”
Cui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Brain–computer interfaces: communication and restoration of movement in paralysis
Birbaumer, N., & Cohen, L. G. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125633 · Cited by 754
Self-citationBreaking the silence: Brain-computer interfaces (BCI) for communication and motor control
Birbaumer, N. (2006) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00456.x · Cited by 722
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Think to Move: a Neuromagnetic Brain-Computer Interface (BCI) System for Chronic Stroke
Buch, E., Weber, C., Cohen, L. G., Braun, C., Dimyan, M. A., Ard, T., Mellinger, J., Caria, A., Soekadar, S., Fourkas, A., et al. (2008) · Stroke · doi:10.1161/strokeaha.107.505313 · Cited by 600
Self-citationEnhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Rehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Social neuroscience and hyperscanning techniques: past, present and future.
Babiloni, F., & Astolfi, L. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.07.006 · Cited by 573
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Brain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
Functional near-infrared spectroscopy: current status and future prospects
Hoshi, Y. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804911 · Cited by 468
Self-citationReal-time fMRI neurofeedback: Progress and challenges
Sulzer, J., Haller, S., Scharnowski, F., Weiskopf, N., Birbaumer, N., Blefari, M. L., Bruehl, A. B., Cohen, L. G., deCharms, R. C., Gassert, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.033 · Cited by 453
Self-citationBrain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Brain-Computer Interfaces: Beyond Medical Applications
van Erp, J., Lotte, F., & Tangermann, M. (2012) · Computer · doi:10.1109/mc.2012.107 · Cited by 362
Thinking, Walking, Talking: Integratory Motor and Cognitive Brain Function
Leisman, G., Moustafa, A., & Shafir, T. (2016) · Frontiers in Public Health · doi:10.3389/fpubh.2016.00094 · Cited by 370
Mental workload during n-back task—quantified in the prefrontal cortex using fNIRS
Herff, C., Heger, D., Fortmann, O., Hennrich, J., Putze, F., & Schultz, T. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00935 · Cited by 365
Real-time fMRI and its application to neurofeedback
Weiskopf, N. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.009 · Cited by 329
The brain–computer interface cycle
Gerven, M. V., Farquhar, J., Schaefer, R., Vlek, R., Geuze, J., Nijholt, A., Ramsey, N., Haselager, P., Vuurpijl, L., Gielen, S., et al. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/041001 · Cited by 329
Naseer, N., & Hong, K.-S. (2013) · Neuroscience Letters · doi:10.1016/j.neulet.2013.08.021 · Cited by 301
Open Access Dataset for EEG+NIRS Single-Trial Classification
Shin, J., von Luhmann, A., Blankertz, B., Kim, D.-W., Jeong, J., Hwang, H.-J., & Muller, K.-R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2628057 · Cited by 287
Mental stress assessment using simultaneous measurement of EEG and fNIRS
Al-Shargie, F., Kiguchi, M., Badruddin, N., Dass, S. C., Hani, A. F. M., & Tang, T. B. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003882 · Cited by 284
Feature Extraction and Classification Methods for Hybrid fNIRS-EEG Brain-Computer Interfaces
Hong, K.-S., Khan, M. J., & Hong, M. J. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00246 · Cited by 283
Brain–computer interface in paralysis
Birbaumer, N., Murguialday, A. R., & Cohen, L. (2008) · Current Opinion in Neurology · doi:10.1097/wco.0b013e328315ee2d · Cited by 275
Self-citationClassification of prefrontal and motor cortex signals for three-class fNIRS-BCI
Hong, K.-S., Naseer, N., & Kim, Y.-H. (2015) · Neuroscience Letters · doi:10.1016/j.neulet.2014.12.029 · Cited by 276
The self-regulating brain and neurofeedback: experimental science and clinical promise
Thibault, R. T., Lifshitz, M., & Raz, A. (2016) · Cortex · doi:10.1016/j.cortex.2015.10.024 · Cited by 272
Mihara, M., Hattori, N., Hatakenaka, M., Yagura, H., Kawano, T., Hino, T., & Miyai, I. (2013) · Stroke · doi:10.1161/strokeaha.111.674507 · Cited by 256
Neuroimaging-based approaches in the brain–computer interface
Min, B.-K., Marzelli, M. J., & Yoo, S.-S. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.08.002 · Cited by 150
Using fNIRS brain sensing in realistic HCI settings: experiments and guidelines
Solovey, E. T., Girouard, A., Chauncey, K., Hirshfield, L. M., Sassaroli, A., Zheng, F., Fantini, S., & Jacob, R. J. K. (2009) · Proceedings of the 22nd annual ACM symposium on User interface software and technology · doi:10.1145/1622176.1622207 · Cited by 115
Thibault, R. T., Lifshitz, M., Birbaumer, N., & Raz, A. (2015) · Psychotherapy and Psychosomatics · doi:10.1159/000371714 · Cited by 112
“The available evidence supports the efficacy of fNIRS-BCIs [112,113].”
BackgroundSelf-citationHow feedback, motor imagery, and reward influence brain self‐regulation using real‐time fMRI
Sepulveda, P., Sitaram, R., Rana, M., Montalba, C., Tejos, C., & Ruiz, S. (2016) · Human Brain Mapping · doi:10.1002/hbm.23228 · Cited by 90
Self-citationBenchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
Pels, E. G. M., Aarnoutse, E. J., Ramsey, N. F., & Vansteensel, M. J. (2017) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968317714577 · Cited by 33
Metadata
- Authors
- Sitaram, R., Zhang, H., Guan, C., Thulasidas, M., Hoshi, Y., Ishikawa, A., Shimizu, K., & Birbaumer, N.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2007-02
- Volume
- 34
- Issue
- 4
- Pages
- 1416-1427
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2022021629
- Cited by
- 590
- References
- 39
- FWCI
- 10.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.