The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Physiological and modeling evidence for focal transcranial electrical brain stimulation in humans: A basis for high-definition tDCS
Open accessAbstract
Transcranial Direct Current Stimulation (tDCS) is a non-invasive, low-cost, well-tolerated technique producing lasting modulation of cortical excitability. Behavioral and therapeutic outcomes of tDCS are linked to the targeted brain regions, but there is little evidence that current reaches the brain as intended. We aimed to: (1) validate a computational model for estimating cortical electric fields in human transcranial stimulation, and (2) assess the magnitude and spread of cortical electric field with a novel High-Definition tDCS (HD-tDCS) scalp montage using a 4×1-Ring electrode configuration. In three healthy adults, Transcranial Electrical Stimulation (TES) over primary motor cortex (M1) was delivered using the 4×1 montage (4× cathode, surrounding a single central anode; montage radius ~3 cm) with sufficient intensity to elicit a discrete muscle twitch in the hand. The estimated current distribution in M1 was calculated using the individualized MRI-based model, and compared with the observed motor response across subjects. The response magnitude was quantified with stimulation over motor cortex as well as anterior and posterior to motor cortex. In each case the model data were consistent with the motor response across subjects. The estimated cortical electric fields with the 4×1 montage were compared (area, magnitude, direction) for TES and tDCS in each subject. We provide direct evidence in humans that TES with a 4×1-Ring configuration can activate motor cortex and that current does not substantially spread outside the stimulation area. Computational models predict that both TES and tDCS waveforms using the 4×1-Ring configuration generate electric fields in cortex with comparable gross current distribution, and preferentially directed normal (inward) currents. The agreement of modeling and experimental data for both current delivery and focality support the use of the HD-tDCS 4×1-Ring montage for cortically targeted neuromodulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
NON-INVASIVE MAGNETIC STIMULATION OF HUMAN MOTOR CORTEX
Barker, A. T., Jalinous, R., & Freeston, I. L. (1985) · The Lancet · doi:10.1016/s0140-6736(85)92413-4 · Cited by 4,460
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Transcranial direct current stimulation: State of the art 2008
Nitsche, M. A., Cohen, L. G., Wassermann, E. M., Priori, A., Lang, N., Antal, A., Paulus, W., Hummel, F., Boggio, P. S., Fregni, F., et al. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.06.004 · Cited by 3,057
Self-citationSustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617 · cited 2×
“tDCS induces lasting biological effects (Edwards et al., 2009; Nitsche and Paulus, 2001) and is being currently explored to treat a range of neuropsychiatric disorders and facilitate rehabilitation, including after stroke (Hummel et al.”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Self-citationLocalization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
Self-citationEffects of non-invasive cortical stimulation on skilled motor function in chronic stroke
Hummel, F. (2005) · Brain · doi:10.1093/brain/awh369 · Cited by 1,114
Stimulation of the cerebral cortex in the intact human subject
Merton, P. A., & Morton, H. B. (1980) · Nature · doi:10.1038/285227a0 · Cited by 1,094
Nitsche, M. A., Schauenburg, A., Lang, N., Liebetanz, D., Exner, C., Paulus, W., & Tergau, F. (2003) · Journal of Cognitive Neuroscience · doi:10.1162/089892903321662994 · Cited by 1,032
Day, B. L., Dressler, D., Maertens de Noordhout, A., Marsden, C. D., Nakashima, K., Rothwell, J. C., & Thompson, P. D. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017626 · Cited by 931
Cellular Effects of Deep Brain Stimulation: Model-Based Analysis of Activation and Inhibition
McIntyre, C. C., Grill, W. M., Sherman, D. L., & Thakor, N. V. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00989.2003 · Cited by 818
Lang, N., Siebner, H. R., Ward, N. S., Lee, L., Nitsche, M. A., Paulus, W., Rothwell, J. C., Lemon, R. N., & Frackowiak, R. S. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.04233.x · Cited by 769
Modeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
Bikson, M., Inoue, M., Akiyama, H., Deans, J. K., Fox, J. E., Miyakawa, H., & Jefferys, J. G. R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.055772 · Cited by 743
Self-citationShaping the Effects of Transcranial Direct Current Stimulation of the Human Motor Cortex
Nitsche, M. A., Doemkes, S., Karaköse, T., Antal, A., Liebetanz, D., Lang, N., Tergau, F., & Paulus, W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01312.2006 · Cited by 738
Radman, T., Ramos, R. L., Brumberg, J. C., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.007 · Cited by 702
Self-citationKuo, H.-I., Bikson, M., Datta, A., Minhas, P., Paulus, W., Kuo, M.-F., & Nitsche, M. A. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.09.010 · Cited by 695
Self-citationAnalysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Increasing Human Brain Excitability by Transcranial High-Frequency Random Noise Stimulation
Terney, D., Chaieb, L., Moliadze, V., Antal, A., & Paulus, W. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4248-08.2008 · Cited by 680
Stimulation of the human motor cortex through the scalp
Rothwell, J., Thompson, P., Day, B., Boyd, S., & Marsden, C. (1991) · Experimental Physiology · doi:10.1113/expphysiol.1991.sp003485 · Cited by 664
Localization of the motor hand area to a knob on the precentral gyrus.
Yousry, T. A. (1997) · Medical Entomology and Zoology · Cited by 594
Optimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
Self-citationReato, D., Rahman, A., Bikson, M., & Parra, L. C. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.2059-10.2010 · Cited by 573
Self-citationTranscranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567 · cited 4×
“HD-tDCS4×1 model The typical model settings as established previously were used (Datta et al., 2009; Miranda et al., 2006; Wagner et al., 2007), and the aforementioned TES4×1 motor montage was solved for HD-tDCS4×1.”
BackgroundMethodInfluentialAntal, A., Boros, K., Poreisz, C., Chaieb, L., Terney, D., & Paulus, W. (2008) · Brain Stimulation · doi:10.1016/j.brs.2007.10.001 · Cited by 515
Effects of coil design on delivery of focal magnetic stimulation. Technical considerations
Cohen, L. G., Roth, B. J., Nilsson, J., Dang, N., Panizza, M., Bandinelli, S., Friauf, W., & Hallett, M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90113-x · Cited by 409
Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.023 · Cited by 335
Antal, A., Nitsche, M. A., Kincses, T. Z., Kruse, W., Hoffmann, K., & Paulus, W. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03367.x · Cited by 329
A Coil Design for Transcranial Magnetic Stimulation of Deep Brain Regions
Roth, Y., Zangen, A., & Hallett, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200208000-00008 · Cited by 326
Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320
Self-citationSCOPE OF A TECHNIQUE FOR ELECTRICAL STIMULATION OF HUMAN BRAIN, SPINAL CORD, AND MUSCLE
Merton, P. A., Morton, H. B., Hill, D. K., & Marsden, C. D. (1982) · The Lancet · doi:10.1016/s0140-6736(82)90670-5 · Cited by 304
Bikson, M., Datta, A., Rahman, A., & Scaturro, J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.05.020 · Cited by 284
Self-citationMoliadze, V., Antal, A., & Paulus, W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.04.033 · Cited by 270
Borckardt, J. J., Bikson, M., Frohman, H., Reeves, S. T., Datta, A., Bansal, V., Madan, A., Barth, K., & George, M. S. (2012) · The Journal of Pain · doi:10.1016/j.jpain.2011.07.001 · Cited by 268
Self-citationMinhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Self-citationBaudewig, J., Nitsche, M. A., Paulus, W., & Frahm, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<196::aid-mrm1026>3.0.co;2-1 · Cited by 238
Bossetti, C. A., Birdno, M. J., & Grill, W. M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/005 · Cited by 232
Transcranial direct current stimulation (tDCS) in a realistic head model
Sadleir, R. J., Vannorsdall, T. D., Schretlen, D. J., & Gordon, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.052 · Cited by 232
Effects of brain polarization on reaction times and pinch force in chronic stroke
Hummel, F. C., Voller, B., Celnik, P., Floel, A., Giraux, P., Gerloff, C., & Cohen, L. G. (2006) · BMC Neuroscience · doi:10.1186/1471-2202-7-73 · Cited by 221
Thielscher, A., & Kammer, T. (2002) · NeuroImage · doi:10.1006/nimg.2002.1282 · Cited by 206
Mental Changes Resulting from the Passage of Small Direct Currents Through the Human Brain
Lippold, O. C. J., & Redfearn, J. W. T. (1964) · British Journal of Psychiatry · doi:10.1192/bjp.110.469.768 · Cited by 183
Rossini, P. M., Marciani, M. G., Caramia, M. D., Roma, V., & Zarola, F. (1985) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(85)91094-6 · Cited by 160
Edwards, D. J., Krebs, H. I., Rykman, A., Zipse, J., Thickbroom, G. W., Mastaglia, F. L., Pascual‐Leone, Á., & Volpe, B. T. (2009) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2009-0470 · Cited by 152
Self-citationFocusing and targeting of magnetic brain stimulation using multiple coils
Ruohonen, J., & Ilmoniemi, R. J. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522474 · Cited by 107
Guidelines for precise and accurate computational models of tDCS
Bikson, M., & Datta, A. (2011) · Brain stimulation · doi:10.1016/j.brs.2011.06.001 · Cited by 88
Self-citationA theoretical comparison of electric and magnetic stimulation of the brain
Saypol, J. M., Roth, B. J., Cohen, L. G., & Hallett, M. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02584306 · Cited by 86
The electric field induced during magnetic stimulation.
Roth, B. J., Cohen, L. G., & Hallett, M. (1991) · PubMed · Cited by 81
Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS)
Deng, Z., Peterchev, A. V., & Lisanby, S. H. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650502 · Cited by 76
A novel electric design for electromagnetic stimulation-the Slinky coil
Ren, C., TARJAN, P. P., & Popović, D. B. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.412658 · Cited by 68
The Influence of Low-Level Transcortical DC-Currents on Response Speed in Humans
Elbert, T. R., Lutzenberger, W., Rockstroh, B. S., & Birbaumer, N. (1981) · International Journal of Neuroscience · doi:10.3109/00207458108985821 · Cited by 62
Joucla, S., & Yvert, B. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.12.3961 · Cited by 55
Methodology for non-invasive mapping of human motor cortex with electrical stimulation
Cohen, L. G., & Hallett, M. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90062-4 · Cited by 44
Transcranial electric stimulation of motor pathways: a theoretical analysis
Stecker, M. M. (2004) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2003.12.005 · Cited by 36
Cited by
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Self-citationSafety of Transcranial Direct Current Stimulation: Evidence Based Update 2016
Bikson, M., Grossman, P., Thomas, C., Zannou, A. L., Jiang, J., Adnan, T., Mourdoukoutas, A. P., Kronberg, G., Truong, D., Boggio, P., et al. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.06.004 · Cited by 1,396
Self-citationEuropean Stroke Organisation (ESO) guidelines on intravenous thrombolysis for acute ischaemic stroke
Berge, E., Whiteley, W., Audebert, H., De Marchis, G., Fonseca, A. C., Padiglioni, C., Pérez de la Ossa, N., Strbian, D., Tsivgoulis, G., & Turc, G. (2021) · European Stroke Journal · doi:10.1177/2396987321989865 · Cited by 1,355
Antal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationDemaerschalk, B. M., Kleindorfer, D. O., Adeoye, O. M., Demchuk, A. M., Fugate, J. E., Grotta, J. C., Khalessi, A. A., Levy, E. I., Palesch, Y. Y., Prabhakaran, S., et al. (2016) · Stroke · doi:10.1161/str.0000000000000086 · Cited by 670
Metadata
- Authors
- Edwards, D., Cortes, M., Datta, A., Minhas, P., Wassermann, E. M., & Bikson, M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 74
- Pages
- 266-275
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W1991904995
- Cited by
- 468
- References
- 55
- FWCI
- 18.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.