The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Open accessAbstract
We evaluate residual aliasing among simultaneously excited and acquired slices in slice accelerated multiband (MB) echo planar imaging (EPI). No in-plane accelerations were used in order to maximize and evaluate achievable slice acceleration factors at 3 Tesla. We propose a novel leakage (L-) factor to quantify the effects of signal leakage between simultaneously acquired slices. With a standard 32-channel receiver coil at 3 Tesla, we demonstrate that slice acceleration factors of up to eight (MB = 8) with blipped controlled aliasing in parallel imaging (CAIPI), in the absence of in-plane accelerations, can be used routinely with acceptable image quality and integrity for whole brain imaging. Spectral analyses of single-shot fMRI time series demonstrate that temporal fluctuations due to both neuronal and physiological sources were distinguishable and comparable up to slice-acceleration factors of nine (MB = 9). The increased temporal efficiency could be employed to achieve, within a given acquisition period, higher spatial resolution, increased fMRI statistical power, multiple TEs, faster sampling of temporal events in a resting state fMRI time series, increased sampling of q-space in diffusion imaging, or more quiet time during a scan.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Self-citationJenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
The Human Connectome Project: A data acquisition perspective
Van Essen, D. C., Ugurbil, K., Auerbach, E., Barch, D., Behrens, T. E. J., Bucholz, R., Chang, A., Chen, L., Corbetta, M., Curtiss, S. W., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.018 · Cited by 2,680
Self-citationRoemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Spectral Analysis for Physical Applications
Percival, D. B., & Walden, A. T. (1993) · Cambridge University Press eBooks · doi:10.1017/cbo9780511622762 · Cited by 2,161
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586 · cited 5×
“Such cross-contamination can lead to false “activation” in slices, as we investigated in a previous study (Moeller et al., 2010).”
InfluentialSelf-citationCorrection for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Self-citationSetsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Griffanti, L., Salimi-Khorshidi, G., Beckmann, C. F., Auerbach, E. J., Douaud, G., Sexton, C. E., Zsoldos, E., Ebmeier, K. P., Filippini, N., Mackay, C. E., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.034 · Cited by 1,262
Self-citationAnalysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77236-x · Cited by 955
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1998) · Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) · Cited by 898
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationTemporally-independent functional modes of spontaneous brain activity
Smith, S. M., Miller, K. L., Moeller, S., Xu, J., Auerbach, E. J., Woolrich, M. W., Beckmann, C. F., Jenkinson, M., Andersson, J., Glasser, M. F., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1121329109 · Cited by 702
Self-citationBreuer, F. A., Blaimer, M., Heidemann, R. M., Mueller, M. F., Griswold, M. A., & Jakob, P. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20401 · Cited by 633
Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
Kundu, P., Inati, S. J., Evans, J. W., Luh, W.-M., & Bandettini, P. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.028 · Cited by 615
High-field fMRI unveils orientation columns in humans
Yacoub, E., Harel, N., & Uğurbil, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804110105 · Cited by 566
Self-citationExperimental determination of the BOLD field strength dependence in vessels and tissue
Gati, J. S., Menon, R. S., Uǧurbil, K., & Rutt, B. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380220 · Cited by 523
Self-citationRetrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475
Poser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 438
Laminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1
Polimeni, J. R., Fischl, B., Greve, D. N., & Wald, L. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.005 · Cited by 431
Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging
Posse, S., Wiese, S., Gembris, D., Mathiak, K., Kessler, C., Grosse-Ruyken, M.-L., Elghahwagi, B., Richards, T., Dager, S. R., & Kiselev, V. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199907)42:1<87::aid-mrm13>3.0.co;2-o · Cited by 388
32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry
Wiggins, G. C., Triantafyllou, C., Potthast, A., Reykowski, A., Nittka, M., & Wald, L. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20925 · Cited by 375
Variable-rate selective excitation
Conolly, S., Nishimura, D., Macovski, A., & Glover, G. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90131-x · Cited by 321
Three dimensional echo-planar imaging at 7 Tesla
Poser, B. A., Koopmans, P. J., Witzel, T., Wald, L. L., & Barth, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.108 · Cited by 284
96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation
Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22028 · Cited by 274
Halving MR imaging time by conjugation: demonstration at 3.5 kG.
Feinberg, D. A., Hale, J. D., Watts, J. C., Kaufman, L., & Mark, A. (1986) · Radiology · doi:10.1148/radiology.161.2.3763926 · Cited by 259
Self-citationUltimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations
Ohliger, M. A., Grant, A. K., & Sodickson, D. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10597 · Cited by 238
General formulation for quantitative G‐factor calculation in GRAPPA reconstructions
Breuer, F. A., Kannengiesser, S. A. R., Blaimer, M., Seiberlich, N., Jakob, P. M., & Griswold, M. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22066 · Cited by 218
Pfeuffer, J., Van de Moortele, P., Ugurbil, K., Hu, X., & Glover, G. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10065 · Cited by 216
Liu, G., Sobering, G., Duyn, J., & Moonen, C. T. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300617 · Cited by 205
Wiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20281 · Cited by 198
Mapping the Organization of Axis of Motion Selective Features in Human Area MT Using High-Field fMRI
Zimmermann, J., Goebel, R., De Martino, F., van de Moortele, P.-F., Feinberg, D., Adriany, G., Chaimow, D., Shmuel, A., Uğurbil, K., & Yacoub, E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028716 · Cited by 188
Self-citationSotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J. L., Auerbach, E. J., Yacoub, E., Feinberg, D., Setsompop, K., Wald, L. L., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24623 · Cited by 186
Self-citationMitra, P. P., Ogawa, S., Hu, X., & Uǧurbil, K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370407 · Cited by 185
Self-citationFunctional Imaging by I0‐ and T2* ‐parameter mapping using multi‐image EPI
Speck, O., & Hennig, J. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400210 · Cited by 147
Auerbach, E. J., Xu, J., Yacoub, E. S., Moeller, S., & Uǧurbil, K. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24719 · Cited by 145
Self-citationPotential and feasibility of parallel MRI at high field
Wiesinger, F., de Moortele, P. V., Adriany, G., Zanche, N. D., Uǧurbil, K., & Pruessmann, K. P. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1050 · Cited by 138
Self-citationNorris, D. G., Koopmans, P. J., Boyacıoğlu, R., & Barth, M. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23152 · Cited by 128
PRESTO-SENSE: An ultrafast whole-brain fMRI technique
Golay, X., Pruessmann, K. P., Weiger, M., Crelier, G. R., Folkers, P. J. M., Kollias, S., & Boesiger, P. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<779::aid-mrm1>3.0.co;2-4 · Cited by 120
Interleaved silent steady state (ISSS) imaging: A new sparse imaging method applied to auditory fMRI
Schwarzbauer, C., Davis, M. H., Rodd, J. M., & Johnsrude, I. S. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.025 · Cited by 113
Wielopolski, P. A., Manning, W. J., & Edelman, R. R. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050406 · Cited by 105
T2* Dependence of Low Frequency Functional Connectivity
Peltier, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1141 · Cited by 102
Heidemann, R. M., Ivanov, D., Trampel, R., Fasano, F., Meyer, H., Pfeuffer, J., & Turner, R. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24156 · Cited by 97
Posse, S., Ackley, E. S., Mutihac, R., Rick, J., Shane, M. S., Murray-Krezan, C. M., Zaitsev, M., & Speck, O. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.059 · Cited by 92
Simultaneous echo refocusing in EPI
Feinberg, D. A., Reese, T. G., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10227 · Cited by 90
Self-citationMartino, F. D., Esposito, F., de Moortele, P. V., Harel, N., Formisano, E., Goebel, R., Uǧurbil, K., & Yacoub, E. S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.008 · Cited by 82
Self-citationAccelerated volumetric MRI with a SENSE/GRAPPA combination
Blaimer, M., Breuer, F., Seiberlich, N., Mueller, M. F., Heidemann, R. M., Jellús̆, V., Wiggins, G. C., Wald, L. L., Griswold, M. A., & Jakob, P. M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20632 · Cited by 79
The road to functional imaging and ultrahigh fields
Uǧurbil, K. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.134 · Cited by 65
Self-citationWhole brain, high resolution spin-echo resting state fMRI using PINS multiplexing at 7T
Koopmans, P. J., Boyacıoğlu, R., Barth, M., & Norris, D. G. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.080 · Cited by 63
Loenneker, T., Hennel, F., & Hennig, J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350613 · Cited by 38
Application of parallel imaging to fMRI at 7 Tesla utilizing a high 1D reduction factor
Moeller, S., de Moortele, P. V., Goerke, U., Adriany, G., & Uǧurbil, K. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20934 · Cited by 37
Self-citationPoser, B. A., Barth, M., Goa, P. E., Deng, W., & Stenger, V. A. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24222 · Cited by 28
Jesmanowicz, A., Nencka, A. S., Li, S., & Hyde, J. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0004 · Cited by 17
Mansfield, P., Harvey, P. R., & Stehling, M. K. (1994) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf01705255 · Cited by 16
Larkman (2001) · doi:10.1002/1522-2586(200102)13:2<313::aid-jmri1045>3.0.co;2-w
Cited by
Image processing and Quality Control for the first 10,000 brain imaging datasets from UK Biobank
Alfaro-Almagro, F., Jenkinson, M., Bangerter, N. K., Andersson, J. L. R., Griffanti, L., Douaud, G., Sotiropoulos, S. N., Jbabdi, S., Hernandez-Fernandez, M., Vallee, E., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.034 · Cited by 1,557
Self-citationGriffanti, L., Salimi-Khorshidi, G., Beckmann, C. F., Auerbach, E. J., Douaud, G., Sexton, C. E., Zsoldos, E., Ebmeier, K. P., Filippini, N., Mackay, C. E., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.034 · Cited by 1,262
Self-citationThe Human Connectome Project's neuroimaging approach
Glasser, M. F., Smith, S. M., Marcus, D. S., Andersson, J. L. R., Auerbach, E. J., Behrens, T. E. J., Coalson, T. S., Harms, M. P., Jenkinson, M., Moeller, S., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4361 · Cited by 1,090
Self-citationHarms, M. P., Somerville, L. H., Ances, B. M., Andersson, J., Barch, D. M., Bastiani, M., Bookheimer, S. Y., Brown, T. B., Buckner, R. L., Burgess, G. C., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.060 · Cited by 584
Self-citationFunctional gradients of the cerebellum
Guell, X., Schmahmann, J. D., Gabrieli, J. D., & Ghosh, S. S. (2018) · eLife · doi:10.7554/elife.36652 · Cited by 472
Metadata
- Authors
- Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 83
- Pages
- 991-1001
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2110000143
- Cited by
- 514
- References
- 61
- FWCI
- 12.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.