MNE software for processing MEG and EEG data
Open accessThe DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Abstract
Magnetoencephalography and electroencephalography (M/EEG) measure the weak electromagnetic signals originating from neural currents in the brain. Using these signals to characterize and locate brain activity is a challenging task, as evidenced by several decades of methodological contributions. MNE, whose name stems from its capability to compute cortically-constrained minimum-norm current estimates from M/EEG data, is a software package that provides comprehensive analysis tools and workflows including preprocessing, source estimation, time–frequency analysis, statistical analysis, and several methods to estimate functional connectivity between distributed brain regions. The present paper gives detailed information about the MNE package and describes typical use cases while also warning about potential caveats in analysis. The MNE package is a collaborative effort of multiple institutes striving to implement and share best methods and to facilitate distribution of analysis pipelines to advance reproducibility of research. Full documentation is available at http://martinos.org/mne.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Self-citationDelorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 2×
“Multiple academic software packages for M/EEG data processing exist, e.g., Brainstorm (Tadel et al., 2011), EEGLAB (Delorme and Makeig, 2004; Delorme et al., 2011), FieldTrip (Oostenveld et al., 2011), NutMeg (Dalal et al., 2011) and SPM (Litvak et al., 2011), all implemented in Matlab, with some dependencies on exter…”
MethodInvestigating causal relations by econometric models and cross-spectral methods
Granger, C. W. J. (1969) · Econometrica · doi:10.2307/1912791 · Cited by 22,989
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Desikan, R. S., Ségonne, F., Fischl, B., Quinn, B. T., Dickerson, B. C., Blacker, D., Buckner, R. L., Dale, A. M., Maguire, R. P., Hyman, B. T., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.021 · Cited by 13,324 · cited 1×
“…auditory evoked response is localized using dSPM and then mapped to “ fsaverage ” . employs probabilistic atlases and cortical folding patterns for an automated subject-speci fi c segmentation of the cortex into anatomical regions (Desikan et al., 2006; Destrieux et al., 2010; Fischl et al., 2004).”
MethodAn algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154 · cited 2×
“It can be estimated using the discrete Fourier transform (DFT), which can be computed ef fi ciently using fast Fourier transform (FFT) algorithms (Cooley and Tukey, 1965).”
MethodWelch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
The NumPy Array: A Structure for Efficient Numerical Computation
van der Walt, S., Colbert, S. C., & Varoquaux, G. (2011) · Computing in Science & Engineering · doi:10.1109/mcse.2011.37 · Cited by 9,381
Research works printed but not linked: 2
- Lin, 2004, Spectral spatiotemporal imaging of cortical oscillations and interactions in the human brain, NeuroImage, 23, 582, 10.1016/j.neuroimage.2004.04.027 · DOI · Paper page
- 2011, vol. 11
Cited by
MEG and EEG data analysis with MNE-Python
Gramfort, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00267 · Cited by 3,784
Self-citationParameterizing neural power spectra into periodic and aperiodic components
Donoghue, T., Haller, M., Peterson, E. J., Varma, P., Sebastian, P., Gao, R., Noto, T., Lara, A. H., Wallis, J. D., Knight, R. T., et al. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00744-x · Cited by 2,254
Assessing and tuning brain decoders: Cross-validation, caveats, and guidelines
Varoquaux, G., Raamana, P. R., Engemann, D. A., Hoyos-Idrobo, A., Schwartz, Y., & Thirion, B. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.10.038 · Cited by 792
Self-citationGrootswagers, T., Wardle, S. G., & Carlson, T. A. (2017) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01068 · Cited by 727
Michalareas, G., Vezoli, J., van Pelt, S., Schoffelen, J.-M., Kennedy, H., & Fries, P. (2016) · Neuron · doi:10.1016/j.neuron.2015.12.018 · Cited by 696
“Both, the FreeSurfer and Caret cortical sheet representations contain more than 10 vertices per hemisphere and were subsampled for MEG source analysis with the MNE software suite (Gramfort et al., 2014).”
Autoreject: Automated artifact rejection for MEG and EEG data
Jas, M., Engemann, D. A., Bekhti, Y., Raimondo, F., & Gramfort, A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.06.030 · Cited by 598
Self-citationAn open-source, high-performance tool for automated sleep staging
Vallat, R., & Walker, M. P. (2021) · eLife · doi:10.7554/elife.70092 · Cited by 363
A hierarchy of linguistic predictions during natural language comprehension
Heilbron, M., Armeni, K., Schoffelen, J.-M., Hagoort, P., & de Lange, F. P. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2201968119 · Cited by 343
Robust EEG-based cross-site and cross-protocol classification of states of consciousness
Engemann, D. A., Raimondo, F., King, J.-R., Rohaut, B., Louppe, G., Faugeras, F., Annen, J., Cassol, H., Gosseries, O., Fernandez-Slezak, D., et al. (2018) · Brain · doi:10.1093/brain/awy251 · Cited by 329
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
“, 2004) implemented in FreeSurfer and MNE software (Gramfort et al., 2014) to segment the brain, skull and scalp compartments.”
Self-citationBrains and algorithms partially converge in natural language processing
Caucheteux, C., & King, J.-R. (2022) · Communications Biology · doi:10.1038/s42003-022-03036-1 · Cited by 318
“A single-layer forward model was generated with the Freesurfer-wrapper implemented in MNE-Python 92 .”
MethodInfluentialRapid Transformation from Auditory to Linguistic Representations of Continuous Speech
Brodbeck, C., Hong, L. E., & Simon, J. Z. (2018) · Current Biology · doi:10.1016/j.cub.2018.10.042 · Cited by 304
Self-citationElectrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Coll, M.-P., Hobson, H., Bird, G., & Murphy, J. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2020.12.012 · Cited by 262
On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Self-citationHuang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Uncovering the structure of clinical EEG signals with self-supervised learning
Banville, H., Chehab, O., Hyvärinen, A., Engemann, D.-A., & Gramfort, A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abca18 · Cited by 245
“Models were trained using a combination of the braindecode [36], MNE-Python [55], PyTorch [56], pyRiemann [57] and scikit-learn [58] packages.”
Self-citationIdentification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“SSP is also implemented in open source software’s which can be used to visualize, analyze and remove artifacts from EEG and MEG datasets [155]–[157].”
MethodA theory of working memory without consciousness or sustained activity
Trübutschek, D., Marti, S., Ojeda, A., King, J.-R., Mi, Y., Tsodyks, M., & Dehaene, S. (2017) · eLife · doi:10.7554/elife.23871 · Cited by 219
MOABB: trustworthy algorithm benchmarking for BCIs
Jayaram, V., & Barachant, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aadea0 · Cited by 210
Bifurcation in brain dynamics reveals a signature of conscious processing independent of report
Sergent, C., Corazzol, M., Labouret, G., Stockart, F., Wexler, M., King, J.-R., Meyniel, F., & Pressnitzer, D. (2021) · Nature Communications · doi:10.1038/s41467-021-21393-z · Cited by 200
Multimodal Neuroimaging in Schizophrenia: Description and Dissemination
Aine, C. J., Bockholt, H. J., Bustillo, J. R., Cañive, J. M., Caprihan, A., Gasparovic, C., Hanlon, F. M., Houck, J. M., Jung, R. E., Lauriello, J., et al. (2017) · Neuroinformatics · doi:10.1007/s12021-017-9338-9 · Cited by 195
“A subject-specific averaged eyeblink was identified and modeled using the signal space projection method (Uusitalo and Ilmoniemi 1997) within the Minimum Norm Estimates (MNE) Python software (Gramfort et al. 2014).”
MethodA multi-subject, multi-modal human neuroimaging dataset
Wakeman, D. G., & Henson, R. N. (2015) · Scientific Data · doi:10.1038/sdata.2015.1 · Cited by 190
Electrophysiological Frequency Band Ratio Measures Conflate Periodic and Aperiodic Neural Activity
Donoghue, T., Dominguez, J., & Voytek, B. (2020) · eneuro · doi:10.1523/eneuro.0192-20.2020 · Cited by 183
Ehinger, B. V., & Dimigen, O. (2019) · PeerJ · doi:10.7717/peerj.7838 · Cited by 178
“To our knowledge, fi ve toolboxes support some form of deconvolution: SPM ( Litvak et al., 2013 ; Penny et al., 2006 ), the rERP extension for EEGLAB ( Burns et al., 2013 ), pyrERP ( Smith, 2013 ), mTRF ( Crosse et al., 2016 ), and MNE ( Gramfort et al., 2014 ).”
ZapLine: A simple and effective method to remove power line artifacts
de Cheveigné, A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116356 · Cited by 178
MEG-BIDS, the brain imaging data structure extended to magnetoencephalography
Niso, G., Gorgolewski, K. J., Bock, E., Brooks, T. L., Flandin, G., Gramfort, A., Henson, R. N., Jas, M., Litvak, V., T. Moreau, J., et al. (2018) · Scientific Data · doi:10.1038/sdata.2018.110 · Cited by 170
Self-citationIFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
“Modern software packages support, with very little user intervention, the use of realistically shaped head models as an alternative to the spherically symmetric head model (Baillet et al., 2011; Gramfort et al., 2013a; Gramfort et al., 2014).”
Self-citationHagen, E., Næss, S., Ness, T. V., & Einevoll, G. T. (2018) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2018.00092 · Cited by 129
“…to consider are for example EEG and MEG source localization methods, for example as provided by open-source projects like MNE (martinos.org/mne, Gramfort et al., 2013, 2014), BrainStorm (neuroimage.usc.edu/brainstorm, Tadel et al., 2011), EEGLAB (sccn.ucsd.edu/eeglab, Delorme and Makeig,…”
MethodPrefrontal Cortex Stimulation Enhances Fear Extinction Memory in Humans
Raij, T., Nummenmaa, A., Marin, M.-F., Porter, D., Furtak, S., Setsompop, K., & Milad, M. R. (2018) · Biological Psychiatry · doi:10.1016/j.biopsych.2017.10.022 · Cited by 156
Can EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142
EEG functional connectivity is partially predicted by underlying white matter connectivity
Chu, C. J., Tanaka, N., Diaz, J., Edlow, B. L., Wu, O., Hämäläinen, M., Stufflebeam, S., Cash, S. S., & Kramer, M. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.033 · Cited by 135
Self-citationCogitate Consortium, Ferrante, O., Gorska-Klimowska, U., Henin, S., Hirschhorn, R., Khalaf, A., Lepauvre, A., Liu, L., Richter, D., Vidal, Y., et al. (2025) · Nature · doi:10.1038/s41586-025-08888-1 · Cited by 136
“24.0) 68 .”
InfluentialDistinct cortical codes and temporal dynamics for conscious and unconscious percepts
Salti, M., Monto, S., Charles, L., King, J.-R., Parkkonen, L., & Dehaene, S. (2015) · eLife · doi:10.7554/elife.05652 · Cited by 121
“A three-layer volume conductor model based on individual head geometry was used in the forward computations (MNE-Suite [Gramfort et al., 2014] Matlab toolbox).”
MethodSelf-citationEEG-Deformer: A Dense Convolutional Transformer for Brain-Computer Interfaces
Ding, Y., Li, Y., Sun, H., Liu, R., Tong, C., Liu, C., Zhou, X., & Guan, C. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3504604 · Cited by 120
“6) SSVEPformer: The SSVEPformer is a Transformer-based method that comprises channel combination, SSVEP-former encoder, multilayer perceptron (MLP) head three core components that can extract spectrum information from the complex spectrum representation of EEG.”
MethodNeymotin, S. A., Daniels, D. S., Caldwell, B., McDougal, R. A., Carnevale, N. T., Jas, M., Moore, C. I., Hines, M. L., Hämäläinen, M., & Jones, S. R. (2020) · eLife · doi:10.7554/elife.51214 · Cited by 109
Self-citationBrain–heart interactions reveal consciousness in noncommunicating patients
Raimondo, F., Rohaut, B., Demertzi, A., Valente, M., Engemann, D. A., Salti, M., Fernandez Slezak, D., Naccache, L., & Sitt, J. D. (2017) · Annals of Neurology · doi:10.1002/ana.25045 · Cited by 106
“4 in combination with Scikit-Learn(35) and MNE-Python.(36,37) Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines(38) were followed thoroughly.”
BackgroundInfluentialSelf-citationA scoping review on the use of consumer-grade EEG devices for research
Sabio, J., Williams, N. S., McArthur, G. M., & Badcock, N. A. (2024) · PLOS ONE · doi:10.1371/journal.pone.0291186 · Cited by 98
Data augmentation for self-paced motor imagery classification with C-LSTM.
Freer, D., & Yang, G.-Z. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab57c0 · Cited by 96
“In preprocessing, the data was first passed through a bandpass filter (7-30 Hz) using the FIRwin filter in the MNE python library [41], then divided into windows of time between 2 and 0.”
MethodFunctional connectivity-based subtypes of individuals with and without autism spectrum disorder
Easson, A. K., Fatima, Z., & McIntosh, A. R. (2019) · Network Neuroscience · doi:10.1162/netn_a_00067 · Cited by 95
Sudre, G., Szekely, E., Sharp, W., Kasparek, S., & Shaw, P. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705229114 · Cited by 93
“A combination of CTF SAMtools (https://www.ctf.com/products/meg/ctf/software. htm), MNE-Python (39), and custom scripts were used in analyses.”
MethodOptical Co-Registration of MRI and On-Scalp MEG
Zetter, R., Iivanainen, J., & Parkkonen, L. (2019) · Scientific Reports · doi:10.1038/s41598-019-41763-4 · Cited by 93
“All analysis was performed using MNE-Python software [18].”
MethodSelf-citationProbing the limits of activity-silent non-conscious working memory
Trübutschek, D., Marti, S., Ueberschär, H., & Dehaene, S. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1820730116 · Cited by 88
Neural dynamics of perceptual inference and its reversal during imagery
Dijkstra, N., Ambrogioni, L., Vidaurre, D., & van Gerven, M. (2020) · eLife · doi:10.7554/elife.53588 · Cited by 89
An adversarial collaboration to critically evaluate theories of consciousness
Cogitate Consortium, Ferrante, O., Gorska-Klimowska, U., Henin, S., Hirschhorn, R., Khalaf, A., Lepauvre, A., Liu, L., Richter, D., Vidal, Y., et al. (2023) · doi:10.1101/2023.06.23.546249 · Cited by 86
Vallat, R., Meunier, D., Nicolas, A., & Ruby, P. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.033 · Cited by 84
Biophysically detailed forward modeling of the neural origin of EEG and MEG signals
Næss, S., Halnes, G., Hagen, E., Hagler, D. J., Dale, A. M., Einevoll, G. T., & Ness, T. V. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117467 · Cited by 66
“Further, EEGs can be calculated from the resulting current dipole oments in combination with head models as presented in this paper, r through other softwares or techniques ( Gramfort et al., 2014 ).”
MethodA hierarchy of linguistic predictions during natural language comprehension
(2020) · doi:10.1101/2020.12.03.410399 · Cited by 63
EskandariNasab, M., Raeisi, Z., Lashaki, R. A., & Najafi, H. (2024) · Scientific Reports · doi:10.1038/s41598-024-58886-y · Cited by 55
Linguistic effect on speech perception observed at the brainstem
Zhao, T. C., & Kuhl, P. K. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1800186115 · Cited by 52
“All data analysis was done using the MNE-Python software (47) in conjunction with the Elekta Neuromag source modeling software (XFit5.”
MethodWens, V., Bourguignon, M., Vander Ghinst, M., Mary, A., Marty, B., Coquelet, N., Naeije, G., Peigneux, P., Goldman, S., & De Tiège, X. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.081 · Cited by 51
An Internet-Based Real-Time Audiovisual Link for Dual MEG Recordings
Zhdanov, A., Nurminen, J., Baess, P., Hirvenkari, L., Jousmäki, V., Mäkelä, J. P., Mandel, A., Meronen, L., Hari, R., & Parkkonen, L. (2015) · PLOS ONE · doi:10.1371/journal.pone.0128485 · Cited by 47
Self-citationDoes the mismatch negativity operate on a consciously accessible memory trace?
Dykstra, A. R., & Gutschalk, A. (2015) · Science Advances · doi:10.1126/sciadv.1500677 · Cited by 42
Stroganova, T. A., Komarov, K. S., Sysoeva, O. V., Goiaeva, D. E., Obukhova, T. S., Ovsiannikova, T. M., Prokofyev, A. O., & Orekhova, E. V. (2020) · Molecular Autism · doi:10.1186/s13229-020-00408-4 · Cited by 40
Lists with and without syntax: a new approach to measuring the neural processing of syntax
Law, R., & Pylkkänen, L. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.1179-20.2021 · Cited by 37
“The noisereduced MEG recording, the digitized head shape, and the head position measurements were then imported into MNE-Python (Gramfort et al., 2014).”
Low dimensional subject representation based transfer learning in eeg decoding
Jeng, P.-Y., Wei, C.-S., Jung, T.-P., & Wang, L.-C. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3025865 · Cited by 35
“To obtain PSD, we adopted an open-source neurophysiologicaldataanalysislibrary-MNE[46],[47].”
MethodZhao, T. C., & Kuhl, P. K. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119242 · Cited by 32
Prolonged intrinsic neural timescales dissociate from phase coherence in schizophrenia
Lechner, S., & Northoff, G. (2023) · Brain Sciences · doi:10.3390/brainsci13040695 · Cited by 27
“tfr_morlet function, with the number of cycles set to half of each frequency [31].”
BackgroundRoberts, T. P. L., Bloy, L., Liu, S., Ku, M., Blaskey, L., & Jackel, C. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.787229 · Cited by 26
Magnetic Source Imaging and Infant MEG: Current Trends and Technical Advances
Kao, C., & Zhang, Y. (2019) · Brain Sciences · doi:10.3390/brainsci9080181 · Cited by 19
Laminar specificity of the auditory perceptual awareness negativity: a biophysical modeling study
Fernandez Pujol, C., Blundon, E. G., & Dykstra, A. R. (2023) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1011003 · Cited by 14
“Alignment of the MRI and MEG coordinate frames was done in MNE-Python [90].”
MethodA Spectrotemporal Correlate of Language Impairment in Autism Spectrum Disorder
Bloy, L., Shwayder, K., Blaskey, L., Roberts, T. P. L., & Embick, D. (2019) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-019-04040-x · Cited by 11
Confirmation bias through selective readout of information encoded in human parietal cortex
Park, H., Arazi, A., Talluri, B. C., Celotto, M., Panzeri, S., Stocker, A. A., & Donner, T. H. (2025) · Nature Communications · doi:10.1038/s41467-025-61010-x · Cited by 10
Normal Evoked Response to Rapid Sequences of Tactile Pulses in Autism Spectrum Disorders
Ganesan, S., Khan, S., Garel, K.-L. A., Hämäläinen, M. S., & Kenet, T. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00433 · Cited by 9
“The current distribution was estimated using the minimum-norm estimate (MNE) by fixing the source orientation to be perpendicular to the cortex (Gramfort et al., 2014).”
BackgroundMethodSelf-citation(2024) · doi:10.1016/j.jneumeth.2024.110277 · Cited by 4
Lingelbach, K., Tagalidou, N., Markey, P. S., Föll, B., Peissner, M., & Vukelić, M. (2022) · Mensch und Computer 2022 · doi:10.1145/3543758.3543771 · Cited by 2
Goble, G., Hennessy, V., Cheng, T.-H. Z., Rodda, A., Taulu, S., Gordon, R. L., & Zhao, T. C. (2026) · PLOS One · doi:10.1371/journal.pone.0335596
“5 with default infant settings [56,63].”
Metadata
- Authors
- Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-02
- Volume
- 86
- Pages
- 446-460
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2135595031
- Cited by
- 1,951
- References
- 103
- FWCI
- 21.71
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (5R01EB009048, P41RR014075)
- National Institute on Deafness and Other Communication Disorders (F32DC012456)
- NSF (0958669, 1042134)
- ERC-YStG-263584
- aivoAALTO
- Swiss National Science Foundation Early Postdoc. Mobility (148485)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.