The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Active Exoskeleton Control Systems: State of the Art
Open accessAbstract
To get a compliant active exoskeleton controller, the force interaction controllers are mostly used in form of either the impedance or admittance controllers. The impedance or admittance controllers can only work if they are followed by either the force or the position controller respectively. These combinations place the impedance or admittance controller as high-level controller while the force or position controller as low-level controller. From the application point of view, the exoskeleton controllers are equipped by task controllers that can be formed in several ways depend on the aims. This paper presents the review of the control systems in the existing active exoskeleton in the last decade. The exoskeleton control system can be categorized according to the model system, the physical parameters, the hierarchy and the usage. These considerations give different control schemes. The main consideration of exoskeleton control design is how to achieve the best control performances. However, stability and safety are other important issues that have to be considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
1987 american control conference
(1987) · IEEE Control Systems Magazine · doi:10.1109/mcs.1987.1105260 · Cited by 1,402
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Upper-Limb Powered Exoskeleton Design
Perry, J. C., Rosen, J., & Burns, S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901934 · Cited by 1,023
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
Wearable Robots: Biomechatronic Exoskeletons
(2008) · Wiley eBooks · doi:10.1002/9780470987667 · Cited by 517
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 5×
“The LOKOMAT exoskeleton is an example of the early treadmill gait trainer[13, 14].”
MethodInfluential2011 IEEE International Conference on Robotics and Automation (ICRA 2011)
(2010) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2010.2047467 · Cited by 503
HAL: Hybrid Assistive Limb Based on Cybernics
Sankai, Y. (2010) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-642-14743-2_3 · Cited by 479
Intention-based walking support for paraplegia patients with robot suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2007) · Advanced Robotics · doi:10.1163/156855307781746061 · Cited by 474
ARMin: a robot for patient-cooperative arm therapy
Nef, T., Mihelj, M., & Riener, R. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0226-6 · Cited by 445
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Design and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Intention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Wearable Robots: Biomechatronic Exoskeletons
Pons, J. L. (2008) · Cited by 394
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382
Neuro-Fuzzy Control of a Robotic Exoskeleton With EMG Signals
Kiguchi, K., Tanaka, T., & Fukuda, T. (2004) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2004.832525 · Cited by 364
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 3×
“Others systems like SUEFUL-7[51], Pnue-Wrex[58], WOTAS[30], Lokomat[13], LOPES[59] and ANdROS[18] are also using same controller.”
MethodExoskeletons and robotic prosthetics: a review of recent developments
Bogue, R. (2009) · Industrial Robot: An International Journal · doi:10.1108/01439910910980141 · Cited by 348
Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
Design of a haptic arm exoskeleton for training and rehabilitation
Gupta, A., & O'Malley, M. K. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.875558 · Cited by 328
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
SUEFUL-7: A 7DOF upper-limb exoskeleton robot with muscle-model-oriented EMG-based control
Gopura, R. A. R. C., Kiguchi, K., & Li, Y. (2009) · 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2009.5353935 · Cited by 261
Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm
Cavallaro, E. E., Rosen, J., Perry, J. C., & Burns, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880883 · Cited by 230
Development of active anthropomorphic exoskeletons
Vukobratovic, M., Hristic, D., & Stojiljkovic, Z. (1974) · Medical & Biological Engineering · doi:10.1007/bf02629836 · Cited by 216
EMG and EPP-integrated human-machine interface between the paralyzed and rehabilitation exoskeleton
Yin, Y. H., Fan, Y. J., & Xu, L. D. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2178034 · Cited by 197
RUPERT: An exoskeleton robot for assisting rehabilitation of arm functions
Balasubramanian, S., Wei, R., Perez, M., Shepard, B., Koeneman, E., Koeneman, J., & He, J. (2008) · 2008 Virtual Rehabilitation · doi:10.1109/icvr.2008.4625154 · Cited by 194
ARMin - Exoskeleton for Arm Therapy in Stroke Patients
Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., & Riener, R. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428408 · Cited by 192
Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Gopura, R. A. R. C., & Kiguchi, K. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209630 · Cited by 192
A Review of exoskeleton-type systems and their key technologies
Yang, C.-J., Zhang, J.-F., Chen, Y., Dong, Y.-M., & Zhang, Y. (2008) · Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes936 · Cited by 187
Development of power assisting suit for assisting nurse labor
YAMAMOTO, K., HYODO, K., ISHII, M., & MATSUO, T. (2002) · JSME International Journal Series C · doi:10.1299/jsmec.45.703 · Cited by 169
Arm rehabilitation with a robotic exoskeleleton in Virtual Reality
Frisoli, A., Borelli, L., Montagner, A., Marcheschi, S., Procopio, C., Salsedo, F., Bergamasco, M., Carboncini, M. C., Tolaini, M., & Rossi, B. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428491 · Cited by 161
2015 IEEE International Conference on Rehabilitation Robotics (ICORR)
(2015) · doi:10.1109/icorr34445.2015 · Cited by 159
A Control Strategy for Upper Limb Robotic Rehabilitation With a Dual Robot System
Culmer, P., Jackson, A. E., Makower, S., Richardson, R. C., Cozens, J. A., Levesley, M. C., & Bhakta, B. B. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2030796 · Cited by 149
A Pneumatic Robot for Re-Training Arm Movement after Stroke: Rationale and Mechanical Design
Sanchez, R. J., Wolbrecht, E. T., Smith, R. A., Liu, J., Rao, S. M., Cramer, S. C., Rahman, T., Bobrow, J. E., & Reinkensmeyer, D. J. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501151 · Cited by 144
Mosher, R. S. (1967) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/670088 · Cited by 142
Design of an active one-degree-of-freedom lower-limb exoskeleton with inertia compensation
Aguirre-Ollinger, G., Colgate, J. E., Peshkin, M. A., & Goswami, A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910385730 · Cited by 140
A brief review on upper extremity robotic exoskeleton systems
Gopura, R. A. R. C., Kiguchi, K., & Bandara, D. S. V. (2011) · IEEE International Conference on Industrial and Information Systems (ICIIS) · doi:10.1109/iciinfs.2011.6038092 · Cited by 140
Development of an exoskeleton haptic interface for virtual task training
Carignan, C. R., Tang, J. E., & Roderick, S. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354834 · Cited by 130
Ren, Y., Park, H., & Zhang, L. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209482 · Cited by 128
Aguirre-Ollinger, G., Colgate, J. E., Peshkin, M. A., & Goswami, A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2176960 · Cited by 126
Control and system identification for the Berkeley lower extremity exoskeleton (BLEEX)
Ghan, J., Steger, R., & Kazerooni, H. (2006) · Advanced Robotics · doi:10.1163/156855306778394012 · Cited by 125
Performances of Hill-Type and Neural Network Muscle Models—Toward a Myosignal-Based Exoskeleton
Rosén, J., Fuchs, M. B., & Arcan, M. (1999) · Computers and Biomedical Research · doi:10.1006/cbmr.1999.1524 · Cited by 122
PID admittance control for an upper limb exoskeleton
Yu, W., Rosén, J., & Li, X. (2011) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2011.5991147 · Cited by 110
Robot-assisted gait rehabilitation: From exoskeletons to gait systems
Low, K. H. (2011) · Defense Science Research Conference and Expo (DSR) · doi:10.1109/dsr.2011.6026886 · Cited by 97
UPPER LIMB POWERED EXOSKELETON
Rosén, J., & Perry, J. C. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s021984360700114x · Cited by 94
Biomimetic orthosis for the neurorehabilitation of the elbow and shoulder (BONES)
Klein, J., Spencer, S. J., Allington, J., Minakata, K., Wolbrecht, E. T., Smith, R. A., Bobrow, J. E., & Reinkensmeyer, D. J. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762866 · Cited by 86
Gait support for complete spinal cord injury patient by synchronized leg-swing with HAL
Tsukahara, A., Hasegawa, Y., & Sankai, Y. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094827 · Cited by 70
Design and control of a robotic lower extremity exoskeleton for gait rehabilitation
Unluhisarcikli, O., Pietrusinski, M., Weinberg, B., Bonato, P., & Mavroidis, C. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094973 · Cited by 66
EMG–force modeling using parallel cascade identification
Hashemi, J., Morin, E. L., Mousavi, P., Mountjoy, K., & Hashtrudi-Zaad, K. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.10.012 · Cited by 55
Miller, L. M., & Rosén, J. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5628069 · Cited by 52
Pneumatic Control of Robots for Rehabilitation
Wolbrecht, E. T., Reinkensmeyer, D. J., & Bobrow, J. E. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909103787 · Cited by 52
Robotic assisted rehabilitation in Virtual Reality with the L-EXOS
Antonio, F., Bergamasco, M., Carboncini, M. C., & Bruno, R. (2009) · Studies in health technology and informatics · doi:10.3233/978-1-60750-018-6-40 · Cited by 44
The ESA Human Arm Exoskeleton for Space Robotics Telepresence
Schiele, A., & Visentin, G. (2003) · doi:10.13140/rg.2.2.10069.27362 · Cited by 30
Technology of the Robotic Gait Orthosis Lokomat
Riener, R. (2011) · Springer eBooks · doi:10.1007/978-1-4471-2277-7_13 · Cited by 29
Design and implementation of a training strategy in chronic stroke with an arm robotic exoskeleton
Frisoli, A., Sotgiu, E., Procopio, C., Bergamasco, M., Rossi, B., & Chisari, C. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975512 · Cited by 28
RUPERT closed loop control design
Balasubramanian, S., Wei, R., & He, J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649952 · Cited by 26
Robot-Aided Gait Training with LOPES
van Asseldonk, E. H. F., & van der Kooij, H. (2011) · Springer eBooks · doi:10.1007/978-1-4471-2277-7_21 · Cited by 21
Gait Pattern Adaptation for an Active Lower-Limb Orthosis Based on Neural Networks
Gomes, M. A., Silveira, G. L. M., & Siqueira, A. A. G. (2011) · Advanced Robotics · doi:10.1163/016918611x588899 · Cited by 16
Cited by
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Huysamen, K., de Looze, M., Bosch, T., Ortiz, J., Toxiri, S., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2017.11.004 · Cited by 313
Evaluation of a passive exoskeleton for static upper limb activities
Huysamen, K., Bosch, T., de Looze, M., Stadler, K. S., Graf, E., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.009 · Cited by 253
Prediction of gait trajectories based on the Long Short Term Memory neural networks
Zaroug, A., Garofolini, A., Lai, D. T. H., Mudie, K., & Begg, R. (2021) · PLOS ONE · doi:10.1371/journal.pone.0255597 · Cited by 48
Metadata
- Authors
- Anam, K., & Al-Jumaily, A. A.
- Venue
- Procedia Engineering
- Publisher
- Elsevier BV
- Published
- 2012
- Volume
- 41
- Pages
- 988-994
- ISSN
- 1877-7058 (ISSN-L)
- OpenAlex
- W1965852706
- Cited by
- 304
- References
- 68
- FWCI
- 15.84
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.