Magnetoencephalography with optically pumped magnetometers (OPM-MEG): the next generation of functional neuroimaging
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Magnetoencephalography (MEG) measures human brain function via assessment of the magnetic fields generated by electrical activity in neurons. Despite providing high-quality spatiotemporal maps of electrophysiological activity, current MEG instrumentation is limited by cumbersome field sensing technologies, resulting in major barriers to utility. Here, we review a new generation of MEG technology that is beginning to lift many of these barriers. By exploiting quantum sensors, known as optically pumped magnetometers (OPMs), 'OPM-MEG' has the potential to dramatically outperform the current state of the art, promising enhanced data quality (better sensitivity and spatial resolution), adaptability to any head size/shape (from babies to adults), motion robustness (participants can move freely during scanning), and a less complex imaging platform (without reliance on cryogenics). We discuss the current state of this emerging technique and describe its far-reaching implications for neuroscience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“The fundamental problem limiting MEG’s applicability is that, to gain sufficient sensitivity to measure the small (~100 fT) magnetic fields generated by the brain, current MEG systems (which are housed in a magnetically shielded environment to suppress background fields) employ pick-up coils that are coupled to superc…”
BackgroundHAPPER, W. (1972) · Reviews of Modern Physics · doi:10.1103/revmodphys.44.169 · Cited by 1,710
Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements
Taulu, S., & Simola, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/008 · Cited by 1,549
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · cited 4×
“This means high quality MEG data can be acquired and, even if participants move, OPMs continue to function [16].”
BackgroundInfluentialSelf-citationPinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 3×
“albeit at a slower rate, a scenario referred to as the spin-exchange relaxation-free (SERF) regime [6].”
BackgroundInfluentialMagnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 1×
“The fundamental problem limiting MEG’s applicability is that, to gain sufficient sensitivity to measure the small (~100 fT) magnetic fields generated by the brain, current MEG systems (which are housed in a magnetically shielded environment to suppress background fields) employ pick-up coils that are coupled to superc…”
BackgroundMagnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Applications of the signal space separation method
Taulu, S., Simola, J., & Kajola, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853302 · Cited by 548
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471 · cited 2×
“In practice, the noise floor of OPMs currently remains higher than that of a SQUID, nevertheless increased SNR for cortical sources has been realised experimentally; for example, in a healthy adult, the SNR of evoked responses in the sensory cortex generated bymedian nerve stimulation was improved by a factor of ~2 us…”
BackgroundMethodSelf-citationMagnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Self-citationA compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Measuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 3×
“Simulations [12,13] show that this effect provides a four- to fivefold signal enhancement in many cortical areas.”
BackgroundMagnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
Self-citationOn-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250 · cited 3×
“sensors within the room measure the remnant fields and electromagnetic coils generate equal and opposite fields to those measured, thus cancelling them out [35,46,47], termed active shielding.”
BackgroundSelf-citationMagnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer
Johnson, C., Schwindt, P. D. D., & Weisend, M. (2010) · Applied Physics Letters · doi:10.1063/1.3522648 · Cited by 210
Online and offline tools for head movement compensation in MEG
Stolk, A., Todorovic, A., Schoffelen, J.-M., & Oostenveld, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.047 · Cited by 209
On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194 · cited 2×
“, to a factor of ~2 for deeper cortical regions [12] and likely lower in subcortical structures).”
BackgroundSelf-citationBoto, E., Shah, V., Hill, R. M., Rhodes, N., Osborne, J., Doyle, C., Holmes, N., Rea, M., Leggett, J., Bowtell, R., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119027 · Cited by 187
Self-citationA tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180
Self-citationHolmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50697-w · Cited by 163 · cited 2×
“sensors within the room measure the remnant fields and electromagnetic coils generate equal and opposite fields to those measured, thus cancelling them out [35,46,47], termed active shielding.”
BackgroundSelf-citationNon-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158 · cited 2×
“For example, assessment of evoked responses to sensory stimuli of various modalities is commonplace, with OPMs providing high fidelity metrics (see [51] for an excellent example).”
BackgroundTheoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system
Brookes, M. J., Boto, E., Rea, M., Shah, V., Osborne, J., Holmes, N., Hill, R. M., Leggett, J., Rhodes, N., & Bowtell, R. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118025 · Cited by 151
Self-citationFeys, O., Corvilain, P., Aeby, A., Sculier, C., Holmes, N., Brookes, M., Goldman, S., Wens, V., & De Tiège, X. (2022) · Radiology · doi:10.1148/radiol.212453 · Cited by 144 · cited 2×
“Perhaps most significantly, a recent study [53] aimed to measure interictal epileptic discharges in children, aged 5–9 years, using a wearable OPM array, comparing the results with measures from the same individuals in a SQUID system.”
MethodSelf-citationCohen-Tannoudji, C., Dupont-Roc, J., Haroche, S., & Laloë, F. (1970) · Revue de Physique Appliquée · doi:10.1051/rphysap:019700050109500 · Cited by 143
Strand, S., Lutter, W., Strasburger, J. F., Shah, V., Baffa, O., & Wakai, R. T. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.013436 · Cited by 136 · cited 1×
“It is also becoming apparent that OPM use is not limited to the brain, with arrays also having been used to measure electrophysiological signals in the muscles [22], peripheral nerves [23], spinal cord [24], retina [25], and the foetus [26].”
BackgroundWearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
Self-citationMeasuring functional connectivity with wearable MEG
Boto, E., Hill, R. M., Rea, M., Holmes, N., Seedat, Z. A., Leggett, J., Shah, V., Osborne, J., Bowtell, R., & Brookes, M. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117815 · Cited by 132
Self-citationMulti-sensor magnetoencephalography with atomic magnetometers
Johnson, C. N., Schwindt, P. D. D., & Weisend, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/17/6065 · Cited by 131
Towards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128 · cited 2×
“In the case of objects attached to the head, the interference fields are static relative to the sensors and so can potentially be offset by onboard-sensor electromagnetic coils [48].”
BackgroundSelf-citationPrecision magnetic field modelling and control for wearable magnetoencephalography
Rea, M., Holmes, N., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Woolger, D., Dawson, E., Shah, V., Osborne, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118401 · Cited by 118
Self-citationUsing OPMs to measure neural activity in standing, mobile participants
Seymour, R. A., Alexander, N., Mellor, S., O'Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118604 · Cited by 102
Potential of on‐scalp MEG: Robust detection of human visual gamma‐band responses
Iivanainen, J., Zetter, R., & Parkkonen, L. (2020) · Human Brain Mapping · doi:10.1002/hbm.24795 · Cited by 99
Head movements of children in MEG: Quantification, effects on source estimation, and compensation
Wehner, D. T., Hämäläinen, M., Mody, M., & Ahlfors, S. P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.026 · Cited by 93
Mouth magnetoencephalography: A unique perspective on the human hippocampus
Tierney, T. M., Levy, A. D., Barry, D. N., Meyer, S. S., Shigihara, Y., Everatt, M., Mellor, S., López, J. D., Bestmann, S., Holmes, N., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117443 · Cited by 91
Self-citationNardelli, N. V., Perry, A. R., Krzyzewski, S. P., & Knappe, S. A. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-00086-4 · Cited by 85
Imaging the human hippocampus with optically-pumped magnetoencephalography
Barry, D. N., Tierney, T. M., Holmes, N., Boto, E., Roberts, G., Leggett, J., Bowtell, R., Brookes, M. J., Barnes, G. R., & Maguire, E. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116192 · Cited by 77
Self-citationNenonen, J., Nurminen, J., Kičić, D., Bikmullina, R., Lioumis, P., Jousmäki, V., Taulu, S., Parkkonen, L. T., Putaala, M., & Kähkönen, S. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.03.080 · Cited by 75
Kamada, K., Sato, D., Ito, Y., Natsukawa, H., Okano, K., Mizutani, N., & Kobayashi, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.026601 · Cited by 74
Optically pumped magnetoencephalography in epilepsy
Vivekananda, U., Mellor, S., Tierney, T. M., Holmes, N., Boto, E., Leggett, J., Roberts, G., Hill, R. M., Litvak, V., Brookes, M. J., et al. (2020) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.50995 · Cited by 74
Self-citationMagnetoencephalography With Optically Pumped4He Magnetometers at Ambient Temperature
Labyt, E., Corsi, M.-C., Fourcault, W., Palacios Laloy, A., Bertrand, F., Lenouvel, F., Cauffet, G., Le Prado, M., Berger, F., & Morales, S. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2856367 · Cited by 73
Tierney, T. M., Holmes, N., Meyer, S. S., Boto, E., Roberts, G., Leggett, J., Buck, S., Duque-Muñoz, L., Litvak, V., Bestmann, S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.035 · Cited by 72
Self-citationFourcault, W., Romain, R., Le Gal, G., Bertrand, F., Josselin, V., Le Prado, M., Labyt, E., & Palacios-Laloy, A. (2021) · Optics Express · doi:10.1364/oe.420031 · Cited by 65
Lin, C., Tierney, T. M., Holmes, N., Boto, E., Leggett, J., Bestmann, S., Bowtell, R., Brookes, M. J., Barnes, G. R., & Miall, R. C. (2019) · The Journal of Physiology · doi:10.1113/jp277899 · Cited by 63
Self-citationMagnetoencephalography and the infant brain
Chen, Y., Saby, J. N., Kuschner, E. S., Gaetz, W. C., Edgar, J. C., & Roberts, T. P. L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.059 · Cited by 61
Artifact and head movement compensation in MEG.
Medvedovsky, M., Taulu, S., Bikmullina, R., & Paetau, R. (2007) · PubMed · Cited by 58
Non-invasive laminar inference with MEG: Comparison of methods and source inversion algorithms
Bonaiuto, J. J., Rossiter, H. E., Meyer, S. S., Adams, N., Little, S., Callaghan, M. F., Dick, F., Bestmann, S., & Barnes, G. R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.068 · Cited by 57
Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils
Iivanainen, J., Borna, A., Zetter, R., Carter, T. R., Stephen, J. M., McKay, J., Parkkonen, L. T., Taulu, S., & Schwindt, P. D. D. (2022) · Sensors · doi:10.3390/s22083059 · Cited by 49
Practical real-time MEG-based neural interfacing with optically pumped magnetometers
Wittevrongel, B., Holmes, N., Boto, E., Hill, R., Rea, M., Libert, A., Khachatryan, E., Van Hulle, M. M., Bowtell, R., & Brookes, M. J. (2021) · BMC Biology · doi:10.1186/s12915-021-01073-6 · Cited by 41
Self-citationNugent, A. C., Benitez Andonegui, A., Holroyd, T., & Robinson, S. E. (2022) · Neuroimage: Reports · doi:10.1016/j.ynirp.2022.100093 · Cited by 41
Concurrent spinal and brain imaging with optically pumped magnetometers
Mardell, L. C., Spedden, M. E., O’Neill, G. C., Tierney, T. M., Timms, R. C., Zich, C., Barnes, G. R., & Bestmann, S. (2024) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2024.110131 · Cited by 39
Larson, E., & Taulu, S. (2016) · Brain Topography · doi:10.1007/s10548-016-0523-1 · Cited by 38
Optically pumped magnetometers reveal fasciculations non-invasively
Marquetand, J. C., Middelmann, T., Dax, J., Baek, S., Sometti, D., Grimm, A. M., Lerche, H., Martin, P., Kronlage, C., Siegel, M., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.06.009 · Cited by 38
Measuring the cortical tracking of speech with optically-pumped magnetometers
de Lange, P., Boto, E., Holmes, N., Hill, R. M., Bowtell, R. W., Wens, V., Tiège, X. D., Brookes, M. J., & Bourguignon, M. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117969 · Cited by 37
Self-citationPeripheral Nerve Magnetoneurography With Optically Pumped Magnetometers
Bu, Y., Prince, J., Mojtahed, H., Kimball, D. F., Shah, V., Coleman, T. P., Sarkar, M., Rao, R., Huang, M., Schwindt, P. D. D., et al. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.798376 · Cited by 36
Simulation Study of Different OPM-MEG Measurement Components
Marhl, U., Sander, T. H., & Jazbinšek, V. (2022) · Sensors · doi:10.3390/s22093184 · Cited by 31
Contactless measurements of retinal activity using optically pumped magnetometers
Westner, B. U., Lubell, J. I., Jensen, M., Hokland, S., & Dalal, S. S. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118528 · Cited by 29
Messaritaki, E., Koelewijn, L., Dima, D. C., Williams, G. M., Perry, G., & Singh, K. D. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.038 · Cited by 26
Detection of the 40 Hz auditory steady-state response with optically pumped magnetometers
An, K., Shim, J. H., Kwon, H., Lee, Y., Yu, K.-K., Kwon, M., Chun, W. Y., Hirosawa, T., Hasegawa, C., Iwasaki, S., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-21870-5 · Cited by 22
Studying Brain Function in Children Using Magnetoencephalography
Rapaport, H., Seymour, R. A., Sowman, P. F., Benikos, N., Stylianou, E., Johnson, B. W., Crain, S., & He, W. (2019) · Journal of Visualized Experiments · doi:10.3791/58909 · Cited by 18
Thermal Analysis of Wearable OPM-MEG Array System for Auditory Evoked Experiments
Pang, M., Huang, Z., Wu, H., Ding, Z., & Han, B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3143209 · Cited by 8
Cited by
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Hassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23042204 · Cited by 492
Consciousness in the cradle: on the emergence of infant experience
Bayne, T., Frohlich, J., Cusack, R., Moser, J., & Naci, L. (2023) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2023.08.018 · Cited by 106
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Self-citationNaturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24], see [25] for a review.”
BackgroundSelf-citation
Metadata
- Authors
- Brookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R.
- Venue
- Trends in Neurosciences
- Publisher
- Elsevier BV
- Published
- 2022-08
- Volume
- 45
- Issue
- 8
- Pages
- 621-634
- ISSN
- 0166-2236 (ISSN-L)
- OpenAlex
- W4283731272
- Cited by
- 412
- References
- 65
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.