Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in comparison with intra-arterial or with noninvasive but intermittent blood pressure measurements. We compiled the results of 43 such papers and found systolic, diastolic and mean accuracies, in this order, ranging from -48 to 30 mmHg, from -20 to 18 mmHg, and from -13 to 25 mmHg. Weighted for the number of subjects included pooled accuracies were -0.8 (SD 11.9), -1.6 (8.3) and -1.6 (7.6) mmHg respectively. Subdividing the pooled group according to criteria such as reference blood pressure, place of application, and prototype or commercial device we found no significant differences in mean differences or SD. Measurement at the finger allows uninterrupted recordings of long duration. The transmission of the pressure pulse along the arm arteries, however, causes distortion of the pulse waveform and depression of the mean blood pressure level. These effects can be reduced by appropriate filtering, and upper arm 'return-to-flow' calibration to bring accuracy and precision within AAMI limits. For the assessment of beat-to-beat changes in blood pressure and assessment of blood pressure variability Finapres proved a reliable alternative for invasive measurements when mean and diastolic pressures are concerned. Differences in systolic pressure are larger and reach statistical significance but are not of clinical relevance. Finger arteries are affected by contraction and dilatation in relation to psychological and physical (heat, cold, blood loss, orthostasis) stress. Effects of these phenomena are reduced by the built-in Physiocal algorithm. However, full smooth muscle contraction should be avoided in the awake patient by comforting the patient, and covering the hand. Arterial state can be monitored by observing the behaviour of the Physiocal algorithm. We conclude that Finapres accuracy and precision usually suffice for reliable tracking of changes in blood pressure. Diagnostic accuracy may be achieved with future application of corrective measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Tilt table testing for assessing syncope
Benditt, D. G., Ferguson, D. W., Grubb, B. P., Kapoor, W. N., Kugler, J., Lerman, B. B., Maloney, J. D., Ravielle, A., Ross, B., Sutton, R., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00236-7 · Cited by 568
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 529
Sympathetic Activation and Loss of Reflex Sympathetic Control in Mild Congestive Heart Failure
Grassi, G., Seravalle, G., Cattaneo, B. M., Lanfranchi, A., Vailati, S., Giannattasio, C., Del Bo, A., Sala, C., Bolla, G. B., Pozzi, M., et al. (1995) · Circulation · doi:10.1161/01.cir.92.11.3206 · Cited by 432
Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Imholz, B. P. M., Settels, J. J., van der Meiracker, A. H., Wesseling, K. H., & Wieling, W. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.3.214 · Cited by 344
Self-citationIMHOLZ, B. P. M., MONTFRANS, G. A. V., SETTELS, J. J., HOEVEN, G. M. A. V. D., KAREMAKER, J. M., & WIELING, W. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.6.390 · Cited by 275
Self-citationFeasibility of ambulatory, continuous 24-hour finger arterial pressure recording.
Imholz, B. P., Langewouters, G. J., van Montfrans, G. A., Parati, G., van Goudoever, J., Wesseling, K. H., Wieling, W., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.1.65 · Cited by 259
Self-citationClinical autonomic disorders : evaluation and management
Low, P. A. (1997) · Cited by 250
Physiocal, calibrating finger vascular physiology for finapres
Wesseling, K. H., Wit, B. D., van der Hoeven, G. M. A., Goudoever, J. V., & Settels, J. J. (1995) · TU/e Research Portal · Cited by 229
Omboni, S., Parati, G., Frattola, A., Mutti, E., Di Rienzo, M., Castiglioni, P., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.22.1.26 · Cited by 224
Continuous cardiac output monitoring by pulse contour during cardiac surgery
Jansen, J. R. C., Wesseling, K. H., Settels, J. J., & Schreuder, J. J. (1990) · European Heart Journal · doi:10.1093/eurheartj/11.suppl_i.26 · Cited by 191
Continuous finger arterial pressure: Utility in the cardiovascular laboratory
Imholz, B. P. M., Wieling, W., Langewouters, G. J., & van Montfrans, G. A. (1991) · Clinical Autonomic Research · doi:10.1007/bf01826057 · Cited by 181
Self-citationSprangers, R. L., Wesseling, K. H., Imholz, A. L., Imholz, B. P., & Wieling, W. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.2.523 · Cited by 179
Self-citationSuppression of Alcohol-Induced Hypertension by Dexamethasone
Randin, D., Vollenweider, P., Tappy, L., Jéquier, E., Nicod, P., & Scherrer, U. (1995) · New England Journal of Medicine · doi:10.1056/nejm199506293322601 · Cited by 177
Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger
WESSELING, K. H., SETTELS, J. J., HOEVEN, G. M. A. V. D., NIJBOER, J. A., BUTIJN, M. W. T., & DORLAS, J. C. (1985) · Cardiovascular Research · doi:10.1093/cvr/19.3.139 · Cited by 164
Boehmer, R. D. (1987) · Journal of Clinical Monitoring · doi:10.1007/bf03337384 · Cited by 160
Trazzi, S., Mutti, E., Frattola, A., Imholz, B., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199102000-00003 · Cited by 158
Self-citationModels of brachial to finger pulse wave distortion and pressure decrement
Gizdulich, P., Prentza, A., & Wesseling, K. H. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00003-5 · Cited by 147
INVASIVE V. NON-INVASIVE MEASUREMENT OF ARTERIAL PRESSURE
van Egmond, J., Hasenbos, M. A. W. M., & Crul, J. F. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.4.434 · Cited by 129
Smith, N. T., Wesseling, K. H., & Wit, B. (1985) · The Journal of Clinical Monitoring · doi:10.1007/bf02832685 · Cited by 123
Jellema, W. T., Imholz, B. P. M., Van Goudoever, J., Wesseling, K. H., & Van Lieshout, J. J. (1996) · Clinical Science · doi:10.1042/cs0910193 · Cited by 121
Self-citationThe Measurement of Continuous Finger Arterial Pressure Noninvasively in Stationary Subjects
Wesseling, K. H., Settels, J. J., & de Wit, B. (1986) · Springer eBooks · doi:10.1007/978-3-642-71234-0_22 · Cited by 118
Effects of aging on blood pressure variability in resting conditions.
Veerman, D. P., Imholz, B. P. M., Wieling, W., Karemaker, J. M., & van Montfrans, G. A. (1994) · Hypertension · doi:10.1161/01.hyp.24.1.120 · Cited by 117
Self-citationValsalva's maneuver revisited: a quantitative method yielding insights into human autonomic control
Smith, M. L., Beightol, L. A., Fritsch-Yelle, J. M., Ellenbogen, K. A., Porter, T. R., & Eckberg, D. L. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.271.3.h1240 · Cited by 112
Incidence and hemodynamic characteristics of near-fainting in healthy 6- to 16-year old subjects
van Steenwijk, C. D. J.-D. V., Wieling, W., Johannes, J., Harms, M. P. M., Kuis, W., & Wessling, K. H. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00056-a · Cited by 109
Finger arterial pressure measurement with Finapres.
Wesseling, K. H. (1996) · PubMed · Cited by 105
Bos, W. J. W., Imholz, B. P. M., van Goudoever, J., Wesseling, K. H., & van Montfrans, G. A. (1992) · American Journal of Hypertension · doi:10.1093/ajh/5.8.529 · Cited by 102
Self-citationPETERSEN, M. E. V., WILLIAMS, T. R., & SUTTON, R. (1995) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060791 · Cited by 97
Scanning tunneling microscopy on rough surfaces-quantitative image analysis
Reiss, G., Brückl, H., Vancea, J., Lecheler, R., & Hastreiter, E. (1991) · Journal of Applied Physics · doi:10.1063/1.350267 · Cited by 87
Comparison of intrabrachial and finger blood pressure in healthy elderly volunteers
Rongen, G. A. P. J. M., Bos, W. J. W., Lenders, J. W. M., vanMontfrans, G., VANLIER, H., vanGoudoever, J. B., Wesseling, K. H., & Thien, T. B. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(94)00000-2 · Cited by 85
Dorlas, J. C., Nijboer, J. A., Butijn, W. T., van der Hoeven, G. M. A., Settels, J. J., Wesseling, K. H., & Miller, R. D. (1985) · Anesthesiology · doi:10.1097/00000542-198503000-00022 · Cited by 84
Measurement of heart rate and blood pressure to evaluate disturbances in neurocardiovascular control
Wieling, W., & Karemaker, J. M. (2013) · Oxford University Press eBooks · doi:10.1093/med/9780198566342.003.0025 · Cited by 81
Non‐invasive blood pressure monitoring during head‐up tilt using the Penaz principle
Friedman, D. B., Jensen, F. B., Matzen, S., & Secher, N. H. (1990) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1990.tb03137.x · Cited by 81
Effects of graded vasoconstriction upon the measurement of finger arterial pressure
Imholz, B. P. M., Parati, G., Mancia, G., & Wesseling, K. H. (1992) · Journal of Hypertension · doi:10.1097/00004872-199209000-00010 · Cited by 72
Self-citationEffect of noxious stimulation on sympathetic vasoconstrictor outflow to human muscles.
Nordin, M., & Fagius, J. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp021101 · Cited by 67
Imholz, B. P. M., Dambrink, J. H. A., Karemaker, J. M., & Wieling, W. (1990) · Clinical Science · doi:10.1042/cs0790073 · Cited by 66
Self-citationThe Accuracy of Finapres™ Noninvasive Mean Arterial Pressure Measurements in Anesthetized Patients
Gibbs, N. M., Larach, D. R., & Derr, J. A. (1991) · Anesthesiology · doi:10.1097/00000542-199104000-00004 · Cited by 61
Triedman, J. K., & Saul, J. P. (1994) · The Journal of Clinical Monitoring · doi:10.1007/bf01651461 · Cited by 55
Continuous non-invasive finger blood pressure monitoring in children
Tanaka, H., Thulesius, O., Yamaguchi, H., Mino, M., & Konishi, K. (2008) · Acta Paediatrica · doi:10.1111/j.1651-2227.1994.tb13100.x · Cited by 50
Effect of Regional and Systemic Changes in Vasomotor Tone on Finger Pressure Amplification
Bos, W. J. W., van den Meiracker, A. H., Wesseling, K. H., et al. (1995) · Hypertension · doi:10.1161/01.hyp.26.2.315 · Cited by 44
Lipoproteins and coronary heart disease in the Helsinki Heart Study
Mänttäri, M., Huttunen, J. K., Koskinen, P., Manninen, V., Tenkanen, L., Heinonen, O. P., & Frick, M. H. (1990) · European Heart Journal · doi:10.1093/eurheartj/11.suppl_h.26 · Cited by 41
Effect of temperature on finger artery pressure evaluated by volume clamp technique
Tanaka, H., & Thulesius, O. (1993) · Clinical Physiology · doi:10.1111/j.1475-097x.1993.tb00469.x · Cited by 38
Epstein, R. H., Huffnagle, S. L., & Bartkowski, R. R. (1991) · The Journal of Clinical Monitoring · doi:10.1007/bf01618116 · Cited by 36
Lindqvist, A. (1995) · Clinical Physiology · doi:10.1111/j.1475-097x.1995.tb00513.x · Cited by 33
Kermode, J. L., Davis, N. J., & Thompson, W. R. (1989) · Anaesthesia and Intensive Care · doi:10.1177/0310057x8901700413 · Cited by 29
Epstein, R. H., Bartkowski, R. R., & Huffnagle, S. L. (1991) · Anesthesiology · doi:10.1097/00000542-199111000-00011 · Cited by 29
Incremental Bias in Finapres Estimation of Baseline Blood Pressure Levels Over Time
Ristuccia, H. L., Grossman, P., Watkins, L. L., & Lown, B. (1997) · Hypertension · doi:10.1161/01.hyp.29.4.1039 · Cited by 28
Hildebrandt, W., Sch�tze, H., & Stegemann, J. (1991) · European Journal of Applied Physiology · doi:10.1007/bf00643738 · Cited by 27
Silke, B., Spiers, P., Boyd, S., Graham, E., McParland, G., & Scott, M. (1994) · Clinical Autonomic Research · doi:10.1007/bf01828838 · Cited by 27
Continuous direct and indirect blood pressure measurement (Finapres) in the critically ill
Farquhar, I. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09922.x · Cited by 26
Cardiorespiratory transfer during sleep: a study in healthy young men
van de Borne, P., Biston, P., Paiva, M., Nguyen, H., Linkowski, P., & Degaute, J. P. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.3.h952 · Cited by 25
Kurki, T. S. O., Piirainen, H., & Kurki, P. (1990) · British Journal of Anaesthesia · doi:10.1093/bja/65.4.558 · Cited by 24
Pulse oximetry and finger blood pressure measurement during open-heart surgery
Kurki, T. S. O., Smith, N. T., Sanford, T. J., & HEAD, N. (1989) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01618251 · Cited by 20
The difference in blood pressure between upper arm and finger during physical exercise
Nijboer, J. A., Dorlas, J. C., & Lubbers, J. (1988) · Clinical Physiology · doi:10.1111/j.1475-097x.1988.tb00215.x · Cited by 15
Omboni, S., Smit, A. A. J., & Wieling, W. (1995) · Heart · doi:10.1136/hrt.73.3.290 · Cited by 15
Automated blood pressure measurement during ergometric stress testing: possibilities of Finapres.
Imholz, B. P. M. (1996) · PubMed · Cited by 15
Self-citationde Mey, C., Schroeter, V., Butzer, R., Roll, S., & Belz, G. (1995) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1995.tb04549.x · Cited by 10
Continuous noninvasive blood pressure monitoring during thoracic surgery
Bardoczky, G. I., Levarlet, M., Engelman, E. E., D'Hollander, A. A., & Schmartz, D. (1992) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(91)90045-u · Cited by 7
Narimatsu, E., Ohta, I., Iwasaki, H., & Namiki, A. (1991) · Anesthesiology · doi:10.1097/00000542-199109001-00795 · Cited by 6
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“A substantial number of comparative and methodological studies have been published on the technology, including a general review by Imholz et al (1998).”
BackgroundMethodEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Metadata
- Authors
- Imholz, B.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-06
- Volume
- 38
- Issue
- 3
- Pages
- 605-616
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2147476476
- Cited by
- 834
- References
- 61
- FWCI
- 19.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.