Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in comparison with intra-arterial or with noninvasive but intermittent blood pressure measurements. We compiled the results of 43 such papers and found systolic, diastolic and mean accuracies, in this order, ranging from -48 to 30 mmHg, from -20 to 18 mmHg, and from -13 to 25 mmHg. Weighted for the number of subjects included pooled accuracies were -0.8 (SD 11.9), -1.6 (8.3) and -1.6 (7.6) mmHg respectively. Subdividing the pooled group according to criteria such as reference blood pressure, place of application, and prototype or commercial device we found no significant differences in mean differences or SD. Measurement at the finger allows uninterrupted recordings of long duration. The transmission of the pressure pulse along the arm arteries, however, causes distortion of the pulse waveform and depression of the mean blood pressure level. These effects can be reduced by appropriate filtering, and upper arm 'return-to-flow' calibration to bring accuracy and precision within AAMI limits. For the assessment of beat-to-beat changes in blood pressure and assessment of blood pressure variability Finapres proved a reliable alternative for invasive measurements when mean and diastolic pressures are concerned. Differences in systolic pressure are larger and reach statistical significance but are not of clinical relevance. Finger arteries are affected by contraction and dilatation in relation to psychological and physical (heat, cold, blood loss, orthostasis) stress. Effects of these phenomena are reduced by the built-in Physiocal algorithm. However, full smooth muscle contraction should be avoided in the awake patient by comforting the patient, and covering the hand. Arterial state can be monitored by observing the behaviour of the Physiocal algorithm. We conclude that Finapres accuracy and precision usually suffice for reliable tracking of changes in blood pressure. Diagnostic accuracy may be achieved with future application of corrective measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Tilt table testing for assessing syncope
Benditt, D. G., Ferguson, D. W., Grubb, B. P., Kapoor, W. N., Kugler, J., Lerman, B. B., Maloney, J. D., Ravielle, A., Ross, B., Sutton, R., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00236-7 · Cited by 568
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 529
Sympathetic Activation and Loss of Reflex Sympathetic Control in Mild Congestive Heart Failure
Grassi, G., Seravalle, G., Cattaneo, B. M., Lanfranchi, A., Vailati, S., Giannattasio, C., Del Bo, A., Sala, C., Bolla, G. B., Pozzi, M., et al. (1995) · Circulation · doi:10.1161/01.cir.92.11.3206 · Cited by 432
Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Imholz, B. P. M., Settels, J. J., van der Meiracker, A. H., Wesseling, K. H., & Wieling, W. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.3.214 · Cited by 344
Self-citationIMHOLZ, B. P. M., MONTFRANS, G. A. V., SETTELS, J. J., HOEVEN, G. M. A. V. D., KAREMAKER, J. M., & WIELING, W. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.6.390 · Cited by 275
Self-citationFeasibility of ambulatory, continuous 24-hour finger arterial pressure recording.
Imholz, B. P., Langewouters, G. J., van Montfrans, G. A., Parati, G., van Goudoever, J., Wesseling, K. H., Wieling, W., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.1.65 · Cited by 259
Self-citationClinical autonomic disorders : evaluation and management
Low, P. A. (1997) · Cited by 250
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“A substantial number of comparative and methodological studies have been published on the technology, including a general review by Imholz et al (1998).”
BackgroundMethodEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
van Beek, A. H., Claassen, J. A., Rikkert, M. G. O., & Jansen, R. W. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.13 · Cited by 485
“The obtained BP recordings using this device correspond well to invasive BP recordings in the brachial artery under various conditions, including during assessment of dCA (Imholz et al, 1998).”
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 470
Gerritsen, J., Dekker, J. M., TenVoorde, B. J., Kostense, P. J., Heine, R. J., Bouter, L. M., Heethaar, R. M., & Stehouwer, C. D. A. (2001) · Diabetes Care · doi:10.2337/diacare.24.10.1793 · Cited by 456
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Eckberg, D. L. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.037192 · Cited by 431
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Initial orthostatic hypotension: review of a forgotten condition
Wieling, W., Krediet, C. T. P., van Dijk, N., Linzer, M., & Tschakovsky, M. E. (2007) · Clinical Science · doi:10.1042/cs20060091 · Cited by 374
Oei, N. Y. L., Everaerd, W. T. A. M., Elzinga, B. M., van Well, S., & Bermond, B. (2006) · Stress · doi:10.1080/10253890600965773 · Cited by 373
Management of Vasovagal Syncope: Controlling or Aborting Faints by Leg Crossing and Muscle Tensing
Krediet, C. T. P., van Dijk, N., Linzer, M., van Lieshout, J. J., & Wieling, W. (2002) · Circulation · doi:10.1161/01.cir.0000030939.12646.8f · Cited by 372
“90 seconds before BP nadir 105 (13) 68 (8) 91 (18)”
Self-citationPhotoplethysmographic assessment of pulse wave reflection
Chowienczyk, P. J., Kelly, R. P., MacCallum, H., Millasseau, S. C., Andersson, T. L. G., Gosling, R. G., Ritter, J. M., & Änggård, E. E. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00441-6 · Cited by 363
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354
Nocturnal blood pressure changes in patients with restless legs syndrome
Pennestri, M. H., Montplaisir, J., Colombo, R., Lavigne, G., & Lanfranchi, P. A. (2007) · Neurology · doi:10.1212/01.wnl.0000259036.89411.52 · Cited by 321
Effectiveness of Physical Counterpressure Maneuvers in Preventing Vasovagal Syncope
van Dijk, N., Quartieri, F., Blanc, J.-J., Garcia-Civera, R., Brignole, M., Moya, A., & Wieling, W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.059 · Cited by 315
Physiological changes of pregnancy and monitoring
Carlin, A., & Alfirevic, Z. (2008) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2008.06.005 · Cited by 310
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.6.952 · Cited by 294
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 265
Social Isolation and Stress-related Cardiovascular, Lipid, and Cortisol Responses
Grant, N., Hamer, M., & Steptoe, A. (2009) · Annals of Behavioral Medicine · doi:10.1007/s12160-009-9081-z · Cited by 263
“Blood pressure (BP) and heart rate in the laboratory were monitored continuously using a Portapres-2, a portable version of the Finapres that shows good reliability and accuracy in a range of settings [43].”
MethodAn introduction into autonomic nervous function
Karemaker, J. M. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6782 · Cited by 259
Blood Pressure Responses to Acute and Chronic Exercise Are Related in Prehypertension
LIU, S., GOODMAN, J., NOLAN, R., LACOMBE, S., & THOMAS, S. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31825408fb · Cited by 232
“recorded at 2-min intervals using an automated sphygmomanometer (Tango; SunTech) to adjust for any Finometer drift associated with long-duration recordings or fluctuations related to reapplication of the Finometer measurement cuff (18).”
MethodNexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff
Eeftinck Schattenkerk, D. W., van Lieshout, J. J., van den Meiracker, A. H., Wesseling, K. R., Blanc, S., Wieling, W., van Montfrans, G. A., Settels, J. J., Wesseling, K. H., & Westerhof, B. E. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2008.368 · Cited by 222
Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200302000-00006 · Cited by 219
Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method
Chandrasekhar, A., Kim, C.-S., Naji, M., Natarajan, K., Hahn, J.-O., & Mukkamala, R. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8674 · Cited by 212
Dynamic coupling between the central and autonomic nervous systems during sleep: a review
de Zambotti, M., Trinder, J., Silvani, A., Colrain, I. M., & Baker, F. C. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2018.03.027 · Cited by 194
Dawson, S. L., Manktelow, B. N., Robinson, T. G., Panerai, R. B., & Potter, J. F. (2000) · Stroke · doi:10.1161/01.str.31.2.463 · Cited by 191
Validation of brachial artery pressure reconstruction from finger arterial pressure
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282fe1d28 · Cited by 186
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Transfer function analysis of dynamic cerebral autoregulation: A CARNet white paper 2022 update
Panerai, R. B., Brassard, P., Burma, J. S., Castro, P., Claassen, J. A., van Lieshout, J. J., Liu, J., Lucas, S. J., Minhas, J. S., Mitsis, G. D., et al. (2023) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x221119760 · Cited by 168
“The accuracy of the signal output from devices providing continuous non-invasive BP measurements is often unreliable.(30) More consistent results can be obtained by recalibrating signals using systolic and diastolic readings from brachial sphygmomanometry.”
BackgroundValidation of the Finometer device for measurement of blood pressure in black women
Schutte, A. E., Huisman, H. W., van Rooyen, J. M., Malan, N. T., & Schutte, R. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001639 · Cited by 164
Saugel, B., Kouz, K., Scheeren, T. W. L., Greiwe, G., Hoppe, P., Romagnoli, S., & de Backer, D. (2021) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.09.049 · Cited by 163
Noninvasive continuous hemodynamic monitoring
Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9375-8 · Cited by 161
“Tracking of changes in BP was already considered good in earlier devices using the finger cuff technology [56].”
MethodNonpharmacological treatment of reflex syncope
Wieling, W., Colman, N., Krediet, C. T. P., & Freeman, R. (2004) · Clinical Autonomic Research · doi:10.1007/s10286-004-1009-x · Cited by 102
Krediet, C. T. P., de Bruin, I. G. J. M., Ganzeboom, K. S., Linzer, M., van Lieshout, J. J., & Wieling, W. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01250.2004 · Cited by 98
“Finapres recordings accurately reflect BP changes during orthostatic stress (7).”
BackgroundSelf-citationEvaluation of blood pressure changes using vascular transit time
Foo, J. Y. A., Lim, C. S., & Wang, P. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/003 · Cited by 62
“Up until recent decades, continuous and non-invasive BP measuring techniques such as the Finapres, Portapres and Finometer were introduced for both research purposes and clinical medicine (Imholz et al 1998, Bogert and van Lieshout 2005).”
MethodDan, D., Hoag, J. B., Ellenbogen, K. A., Wood, M. A., Eckberg, D. L., & Gilligan, D. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01719-9 · Cited by 50
“(The latter formula was corrected for the reduction of arterial pressure at the level of the middle cerebral arteries during tilt [8,9]).”
BackgroundProspective evaluation of non-pharmacological treatment in vasovagal syncope
Romme, J. J. C. M., Reitsma, J. B., Go-Schon, I. K., Harms, M. P. M., Ruiter, J. H., Luitse, J. S. K., Lenders, J. W. M., Wieling, W., & van Dijk, N. (2010) · Europace · doi:10.1093/europace/eup414 · Cited by 47
“, Amsterdam, the Netherlands) or a similar device.(18) Patients practiced the physical counterpressure manoeuvres with the continuous blood pressure tracing on a computer screen as feedback to gain optimal performance.”
Self-citationThe effect of local mild cold exposure on pulse transit time
Zhang, X.-Y., & Zhang, Y.-T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/008 · Cited by 40
Cerebral blood flow during vasovagal syncope induced by active standing or head up tilt
Sung, R. Y. T. (2000) · Archives of Disease in Childhood · doi:10.1136/adc.82.2.154 · Cited by 40
van Rooyen, J., Poglitsch, M., Huisman, H., Mels, C., Kruger, R., Malan, L., Botha, S., Lammertyn, L., Gafane, L., & Schutte, A. (2016) · Journal of the Renin-Angiotensin-Aldosterone System · doi:10.1177/1470320316669880 · Cited by 39
Nisenbaum, M. G., Melo, N. R. D., Giribela, C. R. G., Morais, T. L. D., Guerra, G. M., de Angelis, K., Mostarda, C., Baracat, E. C., & Consolim-Colombo, F. M. (2014) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2014.01.006 · Cited by 37
“Studies in the literature regarding the validation of this method using direct and invasive measurements have demonstrated its accuracy and that the values obtained can be superimposed onto the curve of brachial artery pressure [20–22].”
MethodHuisman, H. W., Schutte, A. E., Schutte, R., van Rooyen, J. M., Fourie, C. M. T., Mels, C. M. C., Smith, W., Malan, N. T., & Malan, L. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hps007 · Cited by 32
Baroreflex mechanisms in irritable bowel syndrome: Part I. Traditional indices
Davydov, D. M., Naliboff, B., Shahabi, L., & Shapiro, D. (2016) · Physiology & Behavior · doi:10.1016/j.physbeh.2016.01.042 · Cited by 29
“The Finapres has been shown to be a suitable tool for reliable tracking of changes in BP [27].”
Method
Metadata
- Authors
- Imholz, B.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-06
- Volume
- 38
- Issue
- 3
- Pages
- 605-616
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2147476476
- Cited by
- 834
- References
- 61
- FWCI
- 19.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.