Flat-panel cone-beam computed tomography for image-guided radiation therapy
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
van Herk, M., Remeijer, P., Rasch, C., & Lebesque, J. V. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00518-6 · Cited by 1,531
Respiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 699
Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
Siewerdsen, J. H., & Jaffray, D. A. (2001) · Medical Physics · doi:10.1118/1.1339879 · Cited by 612
Self-citationvan Herk, M., Bruce, A., Guus Kroes, A. P., Shouman, T., Touw, A., & Lebesque, J. V. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00116-6 · Cited by 518
Roeske, J. C., Forman, J. D., Mesina, C. F., He, T., Pelizzari, C. A., Fontenla, E., Vijayakumar, S., & Chen, G. T. Y. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00225-1 · Cited by 410
Dose Specification for Reporting External Beam Therapy with Photons and Electrons
Wootton, P. (1979) · Medical Physics · doi:10.1118/1.594621 · Cited by 270
Megavoltage CT on a tomotherapy system
Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/10/316 · Cited by 261
Siewerdsen, J. H., & Jaffray, D. A. (2000) · Medical Physics · doi:10.1118/1.1286590 · Cited by 216
Self-citationFahrig, R., & Holdsworth, D. W. (2000) · Medical Physics · doi:10.1118/1.598854 · Cited by 112
Cited by
Cancer and Radiation Therapy: Current Advances and Future Directions
Baskar, R., Lee, K. A., Yeo, R., & Yeoh, K.-W. (2012) · International Journal of Medical Sciences · doi:10.7150/ijms.3635 · Cited by 2,880
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Benedict, S. H., Yenice, K. M., Followill, D., Galvin, J. M., Hinson, W., Kavanagh, B., Keall, P., Lovelock, M., Meeks, S., Papiez, L., et al. (2010) · Medical Physics · doi:10.1118/1.3438081 · Cited by 2,218
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“In case of 3D/3D image-to-image registrations, patient images Bðx3DB Þ like MR and CBCT images are acquired intra- interventionaly (Jolesz, 2005; Jaffray et al., 2002; Pouliot et al., 2005).”
BackgroundMethodWang, H., Dong, L., O'Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., & Cheung, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/011 · Cited by 610
Lagendijk, J. J. W., Raaymakers, B. W., Raaijmakers, A. J. E., Overweg, J., Brown, K. J., Kerkhof, E. M., van der Put, R. W., Hårdemark, B., van Vulpen, M., & van der Heide, U. A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.10.034 · Cited by 511
Overview of image-guided radiation therapy
Xing, L., Thorndyke, B., Schreibmann, E., Yang, Y., Li, T.-F., Kim, G.-Y., Luxton, G., & Koong, A. (2006) · Medical Dosimetry · doi:10.1016/j.meddos.2005.12.004 · Cited by 468
Innovations in image-guided radiotherapy
Verellen, D., Ridder, M. D., Linthout, N., Tournel, K., Soete, G., & Storme, G. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2288 · Cited by 384
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Self-citationLow-dose megavoltage cone-beam CT for radiation therapy
Pouliot, J., Bani-Hashemi, A., Chen, J., Svatos, M., Ghelmansarai, F., Mitschke, M., Aubin, M., Xia, P., Morin, O., Bucci, K., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.10.011 · Cited by 374
Bissonnette, J., Balter, P. A., Dong, L., Langen, K. M., Lovelock, D. M., Miften, M., Moseley, D. J., Pouliot, J., Sonke, J., & Yoo, S. (2012) · Medical Physics · doi:10.1118/1.3690466 · Cited by 359
Islam, M. K., Purdie, T. G., Norrlinger, B. D., Alasti, H., Moseley, D. J., Sharpe, M. B., Siewerdsen, J. H., & Jaffray, D. A. (2006) · Medical Physics · doi:10.1118/1.2198169 · Cited by 313
Self-citationSiewerdsen, J. H., Moseley, D. J., Burch, S., Bisland, S. K., Bogaards, A., Wilson, B. C., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1836331 · Cited by 303
Self-citationFlat-detector computed tomography (FD-CT)
Kalender, W. A., & Kyriakou, Y. (2007) · European Radiology · doi:10.1007/s00330-007-0651-9 · Cited by 302
Adaptive Radiotherapy for Anatomical Changes
Sonke, J.-J., Aznar, M., & Rasch, C. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.007 · Cited by 301
Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation
Yang, Y., Schreibmann, E., Li, T., Wang, C., & Xing, L. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/3/011 · Cited by 297
Accurate technique for complete geometric calibration of cone‐beam computed tomography systems
Cho, Y., Moseley, D. J., Siewerdsen, J. H., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1869652 · Cited by 297
Self-citationSiewerdsen, J. H., Daly, M. J., Bakhtiar, B., Moseley, D. J., Richard, S., Keller, H., & Jaffray, D. A. (2006) · Medical Physics · doi:10.1118/1.2148916 · Cited by 283
Self-citationOnline Adaptive Radiation Therapy
Lim-Reinders, S., Keller, B. M., Al-Ward, S., Sahgal, A., & Kim, A. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.04.023 · Cited by 267
Raaijmakers, A. J. E., Raaymakers, B. W., & Lagendijk, J. J. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/006 · Cited by 264
Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L. (2010) · Medical Physics · doi:10.1118/1.3481510 · Cited by 255
Raaymakers, B. W., Raaijmakers, A. J. E., Kotte, A. N. T. J., Jette, D., & Lagendijk, J. J. W. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/17/019 · Cited by 253
Adaptive Radiotherapy for Head-and-Neck Cancer: Initial Clinical Outcomes From a Prospective Trial
Schwartz, D. L., Garden, A. S., Thomas, J., Chen, Y., Zhang, Y., Lewin, J., Chambers, M. S., & Dong, L. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.08.017 · Cited by 246
“ART takes advantage of computed tomographic imaging, such as megavoltage CT (11), CT-onrails (8, 12), or cone-beam CTs (13) performed in the treatment room to serially reassess current location and shape of target volumes and normal anatomy (14, 15).”
BackgroundImplementation and evaluation of various demons deformable image registration algorithms on a GPU
Gu, X., Pan, H., Liang, Y., Castillo, R., Yang, D., Choi, D., Castillo, E., Majumdar, A., Guerrero, T., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/012 · Cited by 243
“…imaging, online adaptive radiation therapy (ART), has been proposed as a promising technology to overcome this challenge (Yan et al. , 1997; Jaffray et al. , 2002; Wu et al. , 2002; Birkner et al. , 2003; Wu et al. , 2004; Mohan et al. , 2005; de la Zerda et al. , 2007; Lu et al. , 2008;…”
BackgroundCone-beam-CT guided radiation therapy: technical implementation
Létourneau, D., Wong, J. W., Oldham, M., Gulam, M., Watt, L., Jaffray, D. A., Siewerdsen, J. H., & Martinez, A. A. (2005) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2005.03.001 · Cited by 241
“As a result of laboratory investigations that spanned nearly a decade [8,15–18,34–36], a prototype was built in our institution and is available for clinical use.”
BackgroundMethodSelf-citationRit, S., Vila Oliva, M., Brousmiche, S., Labarbe, R., Sarrut, D., & Sharp, G. C. (2014) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/489/1/012079 · Cited by 234
Adaptive Radiotherapy for Lung Cancer
Sonke, J.-J., & Belderbos, J. (2010) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2009.11.003 · Cited by 226
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
Intrafractional Motion of the Prostate During Hypofractionated Radiotherapy
Xie, Y., Djajaputra, D., King, C. R., Hossain, S., Ma, L., & Xing, L. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.04.051 · Cited by 207
“On-board cone-beam CT (CBCT) hasrecentlybecomeavailable toprovide volumetricinformation of a patient in the treatment position ( 29 ) . It holds promises for improved target localization and irradiation dose verification (30) . CBCT is valuable in providing 3D or even 4D patient model before treatment and affords a us…”
BackgroundIterative image reconstruction for CBCT using edge‐preserving prior
Wang, J., Li, T., & Xing, L. (2009) · Medical Physics · doi:10.1118/1.3036112 · Cited by 188
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Reymen, B., Oberije, C., Monshouwer, R., Bussink, J., Brink, C., Hansen, O., & Lambin, P. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.04.016 · Cited by 184
Characterization of image quality and image‐guidance performance of a preclinical microirradiator
Clarkson, R., Lindsay, P. E., Ansell, S., Wilson, G., Jelveh, S., Hill, R. P., & Jaffray, D. A. (2011) · Medical Physics · doi:10.1118/1.3533947 · Cited by 172
Self-citationDeformable image registration in radiation therapy
Oh, S., & Kim, S. (2017) · Radiation Oncology Journal · doi:10.3857/roj.2017.00325 · Cited by 165
“The use of more frequent on-line imaging, such as cone beam computerized tomography (CBCT) [2], CT on the rail [3], and integrated magnetic resonance imaging (MRI) [4], can detect these anatomic changes and aid in correcting or minimizing the effect of such changes.”
BackgroundMartinez, A. A., Gonzalez, J., Ye, H., Ghilezan, M., Shetty, S., Kernen, K., Gustafson, G., Krauss, D., Vicini, F., & Kestin, L. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.10.035 · Cited by 162
Self-citationSisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
Self-citationMarkerless Pancreatic Tumor Target Localization Enabled By Deep Learning
Zhao, W., Shen, L., Han, B., Yang, Y., Cheng, K., Toesca, D. A. S., Koong, A. C., Chang, D. T., & Xing, L. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.05.071 · Cited by 88
“…guidance strategies for accurate beam targeting over the last decade, including the use of stereoscopic or monoscopic kV X-ray imaging [10–13], hybrid kV and MV imaging [14, 15], cone-beam computed tomography (CBCT) [16], on-board magnetic resonance imaging (MRI) [17], ultrasound imaging [18], etc.”
Background
Metadata
- Authors
- Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 2002-08
- Volume
- 53
- Issue
- 5
- Pages
- 1337-1349
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W2112095335
- Cited by
- 1,330
- References
- 10
- FWCI
- 37.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.