The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Versatile, Fully Automated, Microfluidic Cell Culture System
Abstract
There is increasing demand for automated and quantitative cell culture technology, driven both by the intense activity in stem cell biology and by the emergence of systems biology. We built a fully automated cell culture screening system based on a microfluidic chip that creates arbitrary culture media formulations in 96 independent culture chambers and maintains cell viability for weeks. Individual culture conditions are customized in terms of cell seeding density, composition of culture medium, and feeding schedule, and each chamber is imaged with time-lapse microscopy. Using this device, we perform the first quantitative measurements of the influence of transient stimulation schedules on the proliferation, osteogenic differentiation, and motility of human primary mesenchymal stem cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell Shape, Cytoskeletal Tension, and RhoA Regulate Stem Cell Lineage Commitment
McBeath, R., Pirone, D. M., Nelson, C. M., Bhadriraju, K., & Chen, C. S. (2004) · Developmental Cell · doi:10.1016/s1534-5807(04)00075-9 · Cited by 4,180
Self-citationMonolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationChaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
The stem-cell niche as an entity of action
Scadden, D. T. (2006) · Nature · doi:10.1038/nature04957 · Cited by 1,856
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
A microfluidic culture platform for CNS axonal injury, regeneration and transport
Taylor, A. M., Blurton-Jones, M., Rhee, S. W., Cribbs, D. H., Cotman, C. W., & Jeon, N. L. (2005) · Nature Methods · doi:10.1038/nmeth777 · Cited by 1,153
An extracellular matrix microarray for probing cellular differentiation
Flaim, C. J., Chien, S., & Bhatia, S. N. (2005) · Nature Methods · doi:10.1038/nmeth736 · Cited by 803
Nanoliter-scale synthesis of arrayed biomaterials and application to human embryonic stem cells
Anderson, D. G., Levenberg, S., & Langer, R. (2004) · Nature Biotechnology · doi:10.1038/nbt981 · Cited by 747
Cited by
Deconstructing the third dimension – how 3D culture microenvironments alter cellular cues
Baker, B. M., & Chen, C. S. (2012) · Journal of Cell Science · doi:10.1242/jcs.079509 · Cited by 1,760
Self-citationMicrofluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Self-citationDroplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
Technologies for Single-Cell Isolation
Gross, A., Schoendube, J., Zimmermann, S., Steeb, M., Zengerle, R., & Koltay, P. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms160816897 · Cited by 445
Automated microfluidic platform for dynamic and combinatorial drug screening of tumor organoids
Schuster, B., Junkin, M., Kashaf, S. S., Romero-Calvo, I., Kirby, K., Matthews, J., Weber, C. R., Rzhetsky, A., White, K. P., & Tay, S. (2020) · Nature Communications · doi:10.1038/s41467-020-19058-4 · Cited by 424
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Boning up on Wolff's Law: Mechanical regulation of the cells that make and maintain bone
Chen, J.-H., Liu, C., You, L., & Simmons, C. A. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.016 · Cited by 422
Mehling, M., & Tay, S. (2014) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.10.005 · Cited by 390
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Rowat, A. C., Jaalouk, D. E., Zwerger, M., Ung, W. L., Eydelnant, I. A., Olins, D. E., Olins, A. L., Herrmann, H., Weitz, D. A., & Lammerding, J. (2013) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.441535 · Cited by 320
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
The Systematic Production of Cells for Cell Therapies
Kirouac, D. C., & Zandstra, P. W. (2008) · Cell Stem Cell · doi:10.1016/j.stem.2008.09.001 · Cited by 301
Fang, X., Liu, Y., Kong, J., & Jiang, X. (2010) · Analytical Chemistry · doi:10.1021/ac1000652 · Cited by 292
Fernandes, T. G., Diogo, M. M., Clark, D. S., Dordick, J. S., & Cabral, J. M. S. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.02.009 · Cited by 285
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
Engineering a Brain Cancer Chip for High-throughput Drug Screening
Fan, Y., Nguyen, D. T., Akay, Y., Xu, F., & Akay, M. (2016) · Scientific Reports · doi:10.1038/srep25062 · Cited by 216
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
High-throughput organ-on-a-chip systems: Current status and remaining challenges
Probst, C., Schneider, S., & Loskill, P. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.02.004 · Cited by 171
Papamichail, L., Koch, L. S., Veerman, D., Broersen, K., & van der Meer, A. D. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1515340 · Cited by 120
Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R. (2010) · Analytical Chemistry · doi:10.1021/ac101870s · Cited by 104
Self-citationTang, Y., Soroush, F., Sheffield, J. B., Wang, B., Prabhakarpandian, B., & Kiani, M. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-09815-9 · Cited by 102
Microfluidic single-cell analysis for systems immunology
Junkin, M., & Tay, S. (2014) · Lab on a Chip · doi:10.1039/c3lc51182k · Cited by 96
A microfluidic platform for drug screening in a 3D cancer microenvironment
Pandya, H. J., Dhingra, K., Prabhakar, D., Chandrasekar, V., Natarajan, S. K., Vasan, A. S., Kulkarni, A., & Shafiee, H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.054 · Cited by 76
Three Dimensional Microfluidic Cell Arrays for ex Vivo Drug Screening with Mimicked Vascular Flow
Dereli-Korkut, Z., Akaydin, H. D., Ahmed, A. H. R., Jiang, X., & Wang, S. (2014) · Analytical Chemistry · doi:10.1021/ac403899j · Cited by 62
Assay of glioma cell responses to an anticancer drug in a cell-based microfluidic device
Liu, W., Sun, P., Yang, L., Wang, J., Li, L., & Wang, J. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0584-5 · Cited by 29
Advances in microfluidic 3D cell culture for preclinical drug development
(2022) · Progress in Molecular Biology and Translational Science · doi:10.1016/bs.pmbts.2021.07.022 · Cited by 23
Laboratory-scale photobiotechnology—current trends and future perspectives
Morschett, H., Loomba, V., Huber, G., Wiechert, W., von Lieres, E., & Oldiges, M. (2018) · FEMS Microbiology Letters · doi:10.1093/femsle/fnx238 · Cited by 14
Metadata
- Authors
- Gómez-Sjöberg, R., Leyrat, A. A., Pirone, D. M., Chen, C. S., & Quake, S. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-23
- Volume
- 79
- Issue
- 22
- Pages
- 8557-8563
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2024971068
- Cited by
- 625
- References
- 19
- FWCI
- 29.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.