Highly Electrocatalytic, Durable, and Stretchable Nanohybrid Fiber for On-Body Sweat Glucose Detection
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
A conformal patch biosensor that can detect biomolecules is one promising technology for wearable sweat glucose self-monitoring. However, developing such a patch is challenging because conferring stretchability to its components is difficult. Herein, we demonstrate a platform for a nonenzymatic, electrochemical sensor patch: a wrinkled, stretchable, nanohybrid fiber (WSNF) in which Au nanowrinkles partially cover the reduced graphene oxide (rGO)/polyurethane composite fiber. The WSNF has high electrocatalytic activity because of synergetic effects between the Au nanowrinkles and the oxygen-containing functional groups on the rGO-supporting matrix which promote the dehydrogenation step in glucose oxidation. The WSNF offers stretchability, high sensitivity, low detection limit, high selectivity against interferents, and high ambient-condition stability, and it can detect glucose in neutral conditions. If this WSNF sensor patch were sewn onto a stretchable fabric and attached to the human body, it could continuously measure glucose levels in sweat to accurately reflect blood glucose levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Cited by
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Self-citationWearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
An overview of stretchable strain sensors from conductive polymer nanocomposites
Chen, J., Yu, Q., Cui, X., Dong, M., Zhang, J., Wang, C., Fan, J., Zhu, Y., & Guo, Z. (2019) · Journal of Materials Chemistry C · doi:10.1039/c9tc03655e · Cited by 390
Significance of nanomaterials in electrochemical glucose sensors: An updated review (2016-2020)
Sehit, E., & Altintas, Z. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112165 · Cited by 380
Graphene-Based Sensors for Human Health Monitoring
Huang, H., Su, S., Wu, N., Wan, H., Wan, S., Bi, H., & Sun, L. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00399 · Cited by 330
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Adeel, M., Rahman, M. M., Caligiuri, I., Canzonieri, V., Rizzolio, F., & Daniele, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112331 · Cited by 327
Lee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Glucose Detection Devices and Methods Based on Metal–Organic Frameworks and Related Materials
Adeel, M., Asif, K., Rahman, M. M., Daniele, S., Canzonieri, V., & Rizzolio, F. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202106023 · Cited by 180
Lee, H.-B., Meeseepong, M., Trung, T. Q., Kim, B.-Y., & Lee, N.-E. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112133 · Cited by 153
Self-citationLi, G., & Wen, D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02474c · Cited by 119
Recent advances in flexible sweat glucose biosensors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac14ef · Cited by 40
Metadata
- Authors
- Toi, P. T., Trung, T. Q., Dang, T. M. L., Bae, C. W., & Lee, N.-E.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-27
- Volume
- 11
- Issue
- 11
- Pages
- 10707-10717
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2917064844
- Cited by
- 156
- References
- 13
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.