The DOI matches its Crossref record; 126 of the 126 references it cites were found in a registry or an index.
Breath Sensors for Health Monitoring
Open accessAbstract
Breath sensors can revolutionize medical diagnostics by on-demand detection and monitoring of health parameters in a noninvasive and personalized fashion. Despite extensive research for more than two decades, however, only a few breath sensors have been translated into clinical practice. Actually, most never even left the scientific laboratories. Here, we describe key challenges that currently impede realization of breath sensors and highlight strategies to overcome them. Specifically, we start with breath marker selection (with emphasis on metabolic and inflammatory markers) and breath sampling. Next, the sensitivity, stability, and selectivity requirements for breath sensors are described. Concepts are elaborated to systematically address these requirements by material design (focusing on chemoresistive metal oxides), orthogonal arrays, and filters. Finally, aspects of portable device integration, user communication, and clinical applicability are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Antiinflammatory Therapy with Canakinumab for Atherosclerotic Disease
Ridker, P. M., Everett, B. M., Thuren, T., MacFadyen, J. G., Chang, W. H., Ballantyne, C., Fonseca, F., Nicolau, J., Koenig, W., Anker, S. D., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1707914 · Cited by 9,482
Global Prevalence of Helicobacter pylori Infection: Systematic Review and Meta-Analysis
Hooi, J. K. Y., Lai, W. Y., Ng, W. K., Suen, M. M. Y., Underwood, F. E., Tanyingoh, D., Malfertheiner, P., Graham, D. Y., Wong, V. W. S., Wu, J. C. Y., et al. (2017) · Gastroenterology · doi:10.1053/j.gastro.2017.04.022 · Cited by 3,375
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Active Nonmetallic Au and Pt Species on Ceria-Based Water-Gas Shift Catalysts
Fu, Q., Saltsburg, H., & Flytzani-Stephanopoulos, M. (2003) · Science · doi:10.1126/science.1085721 · Cited by 2,954
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
Inflammatory mechanisms linking obesity and metabolic disease
Saltiel, A. R., & Olefsky, J. M. (2017) · Journal of Clinical Investigation · doi:10.1172/jci92035 · Cited by 2,212
Multi-dimensional Roles of Ketone Bodies in Fuel Metabolism, Signaling, and Therapeutics
Puchalska, P., & Crawford, P. A. (2017) · Cell Metabolism · doi:10.1016/j.cmet.2016.12.022 · Cited by 1,610
Analysis of discrimination mechanisms in the mammalian olfactory system using a model nose
Persaud, K., & Dodd, G. (1982) · Nature · doi:10.1038/299352a0 · Cited by 1,592
A New Detector for Gaseous Components Using Semiconductive Thin Films.
Seiyama, T., Kato, A., Fujiishi, K., & Nagatani, M. (1962) · Analytical Chemistry · doi:10.1021/ac60191a001 · Cited by 1,486
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Increased nitric oxide in exhaled air of asthmatic patients
Kharitonov, S. A., Yates, D., Robbins, R. A., Barnes, P. J., Logan-Sinclair, R., & Shinebourne, E. A. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90931-8 · Cited by 1,436
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Silicalite, a new hydrophobic crystalline silica molecular sieve
Flanigen, E. M., Bennett, J. M., Grose, R. W., Cohen, J. P., Patton, R. L., Kirchner, R. M., & Smith, J. V. (1978) · Nature · doi:10.1038/271512a0 · Cited by 1,261
Hlatky, M. A., Greenland, P., Arnett, D. K., Ballantyne, C. M., Criqui, M. H., Elkind, M. S. V., Go, A. S., Harrell, F. E., Hong, Y., Howard, B. V., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192278 · Cited by 1,139
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Remarkable Performance of Ir1/FeOx Single-Atom Catalyst in Water Gas Shift Reaction
Lin, J., Wang, A., Qiao, B., Liu, X., Yang, X., Wang, X., Liang, J., Li, J., Liu, J., & Zhang, T. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408574m · Cited by 980
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Predictive, personalized, preventive, participatory (P4) cancer medicine
Hood, L., & Friend, S. H. (2011) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2010.227 · Cited by 900
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Effects of additives on semiconductor gas sensors
Yamazoe, N., Kurokawa, Y., & Seiyama, T. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85034-3 · Cited by 715
Noninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Flame aerosol synthesis of smart nanostructured materials
Strobel, R., & Pratsinis, S. E. (2007) · Journal of Materials Chemistry · doi:10.1039/b711652g · Cited by 594
Self-citationTowards a molecular understanding of shape selectivity
Smit, B., & Maesen, T. L. M. (2008) · Nature · doi:10.1038/nature06552 · Cited by 590
Semiconductor Gas Sensors: Dry Synthesis and Application
Tricoli, A., Righettoni, M., & Teleki, A. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903801 · Cited by 543
Wheless, J. W. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01821.x · Cited by 533
Nutritional Ketosis Alters Fuel Preference and Thereby Endurance Performance in Athletes
Cox, P. J., Kirk, T., Ashmore, T., Willerton, K., Evans, R., Smith, A., Murray, A. J., Stubbs, B., West, J., McLure, S. W., et al. (2016) · Cell Metabolism · doi:10.1016/j.cmet.2016.07.010 · Cited by 530
Breath gas aldehydes as biomarkers of lung cancer
Fuchs, P., Loeseken, C., Schubert, J. K., & Miekisch, W. (2010) · International Journal of Cancer · doi:10.1002/ijc.24970 · Cited by 513
Nakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Self-citationSingle-breath nitric oxide measurements in asthmatic patients and smokers
Persson, M. G., Gustafsson, L. E., Zetterström, O., Agrenius, V., & Ihre, E. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90935-0 · Cited by 483
A wellness study of 108 individuals using personal, dense, dynamic data clouds
Price, N. D., Magis, A. T., Earls, J. C., Glusman, G., Levy, R., Lausted, C., McDonald, D. T., Kusebauch, U., Moss, C. L., Zhou, Y., et al. (2017) · Nature Biotechnology · doi:10.1038/nbt.3870 · Cited by 427
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Indirect calorimetry: methodological and interpretative problems
Simonson, D. C., & DeFronzo, R. A. (1990) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1990.258.3.e399 · Cited by 376
Gisbert, J. P., & Pajares, J. M. (2004) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2004.02203.x · Cited by 374
Current status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357
Self-citationProgress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Early Detection of Cancer: Past, Present, and Future
Schiffman, J. D., Fisher, P. G., & Gibbs, P. (2015) · American Society of Clinical Oncology Educational Book · doi:10.14694/edbook_am.2015.35.57 · Cited by 327
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Self-citationExhaled Ethane, a Marker of Lipid Peroxidation, Is Elevated in Chronic Obstructive Pulmonary Disease
PAREDI, P., KHARITONOV, S. A., LEAK, D., WARD, S., CRAMER, D., & BARNES, P. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9909025 · Cited by 297
Biomarkers of some pulmonary diseases in exhaled breath
Kharitonov, S. A., & Barnes, P. J. (2002) · Biomarkers · doi:10.1080/13547500110104233 · Cited by 290
Increased Carbon Monoxide in Exhaled Air of Asthmatic Patients
ZAYASU, K., SEKIZAWA, K., OKINAGA, S., YAMAYA, M., OHRUI, T., & SASAKI, H. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.4.96-08056 · Cited by 285
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.762 · Cited by 264
Early chronic kidney disease: diagnosis, management and models of care
Wouters, O. J., O'Donoghue, D. J., Ritchie, J., Kanavos, P. G., & Narva, A. S. (2015) · Nature Reviews Nephrology · doi:10.1038/nrneph.2015.85 · Cited by 258
Güntner, A. T., Koren, V., Chikkadi, K., Righettoni, M., & Pratsinis, S. E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00008 · Cited by 257
Self-citationAlfian, G., Syafrudin, M., Ijaz, M. F., Syaekhoni, M. A., Fitriyani, N. L., & Rhee, J. (2018) · Sensors · doi:10.3390/s18072183 · Cited by 248
Selective sensing of NH 3 by Si-doped α-MoO 3 for breath analysis
Güntner, A. T., Righettoni, M., & Pratsinis, S. E. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.09.094 · Cited by 241
Self-citationOn the use of Tedlar® bags for breath-gas sampling and analysis
Beauchamp, J., Herbig, J., Gutmann, R., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046001 · Cited by 236
On the mammalian acetone metabolism: from chemistry to clinical implications
Kalapos, M. P. (2003) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(03)00051-5 · Cited by 224
Elevation of Exhaled Ethane Concentration in Asthma
PAREDI, P., KHARITONOV, S. A., & BARNES, P. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.4.2003064 · Cited by 221
Breath acetone is a reliable indicator of ketosis in adults consuming ketogenic meals,,
Musa-Veloso, K., Likhodii, S. S., & Cunnane, S. C. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.1.65 · Cited by 218
Ferroelectric Tungsten Trioxide
Woodward, P. M., Sleight, A. W., & Vogt, T. (1997) · Journal of Solid State Chemistry · doi:10.1006/jssc.1997.7268 · Cited by 215
Measuring breath acetone for monitoring fat loss: Review
Anderson, J. C. (2015) · Obesity · doi:10.1002/oby.21242 · Cited by 211
The Lactulose Hydrogen Breath Test as a Diagnostic Test for Small-Bowel Bacterial Overgrowth
Rhodes, J. M., Middleton, P., & Jewell, D. P. (1979) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365527909179892 · Cited by 211
Neale, M. C., & Cardon, L. R. (1992) · Methodology for Genetic Studies of Twins and Families · doi:10.1007/978-94-015-8018-2_12 · Cited by 204
Breath Ammonia Measurement in Helicobacter pylori Infection
Kearney, D. J., Hubbard, T., & Putnam, D. (2002) · Digestive Diseases and Sciences · doi:10.1023/a:1020568227868 · Cited by 188
Smith, D., Spanel, P., & Davies, S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1584 · Cited by 180
Kwak, C.-H., Kim, T., Jeong, S., Yoon, J., Kim, J., & Lee, J. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b04245 · Cited by 178
ACETONE IN DIABETIC KETOACIDOSIS
Sulway, M. J., & Malins, J. M. (1970) · The Lancet · doi:10.1016/s0140-6736(70)90218-7 · Cited by 173
RESISTANCE TO KETOSIS IN OBESE SUBJECTS
Kekwick, A., Pawan, G. L. S., & Chalmers, T. M. (1959) · The Lancet · doi:10.1016/s0140-6736(59)91737-4 · Cited by 173
Increased levels of exhaled carbon monoxide in bronchiectasis: a new marker of oxidative stress
Horvath, I., Loukides, S., Wodehouse, T., Kharitonov, S. A., Cole, P. J., & Barnes, P. J. (1998) · Thorax · doi:10.1136/thx.53.10.867 · Cited by 163
Exhaled Pentane Levels in Acute Asthma
Olopade, C. O., Zakkar, M., Swedler, W. I., & Rubinstein, I. (1997) · Chest · doi:10.1378/chest.111.4.862 · Cited by 162
Effect of regulating cholesterol biosynthesis on breath isoprene excretion in men
Stone, B. G., Besse, T. J., Duane, W. C., Dean Evans, C., & DeMaster, E. G. (1993) · Lipids · doi:10.1007/bf02535990 · Cited by 161
Exhaled Pentane and Nitric Oxide Levels in Patients With Obstructive Sleep Apnea
Olopade, C. O., Christon, J. A., Zakkar, M., Swedler, W. I., Rubinstein, I., Hua, C.-W., & Scheff, P. A. (1997) · Chest · doi:10.1378/chest.111.6.1500 · Cited by 158
Zeolites — Versatile materials for gas sensors
Sahner, K., Hagen, G., SCHONAUER, D., REIS, S., & Moos, R. (2008) · Solid State Ionics · doi:10.1016/j.ssi.2008.08.012 · Cited by 148
Fructose Intolerance: An Under-Recognized Problem
Choi, Y. K., Johlin, F. C., Summers, R. W., Jackson, M., & Rao, S. S. C. (2003) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2003.07476.x · Cited by 147
Selective sensing of isoprene by Ti-doped ZnO for breath diagnostics
Güntner, A. T., Pineau, N. J., Chie, D., Krumeich, F., & Pratsinis, S. E. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb01335j · Cited by 147
Self-citationExposed facets induced enhanced acetone selective sensing property of nanostructured tungsten oxide
Jia, Q., Ji, H., Wang, D.-H., Bai, X., Sun, X., & Jin, Z. (2014) · Journal of Materials Chemistry A · doi:10.1039/c4ta01930j · Cited by 145
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Effects of ventilation on the collection of exhaled breath in humans
Cope, K. A., Watson, M., Foster, W. M., Sehnert, S. S., & Risby, T. H. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01034.2003 · Cited by 144
Breath acetone concentration; biological variability and the influence of diet
Španěl, P., Dryahina, K., Rejšková, A., Chippendale, T. W. E., & Smith, D. C. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/8/n01 · Cited by 143
Zeolite membranes for highly selective formaldehyde sensors
Güntner, A. T., Abegg, S., Wegner, K., & Pratsinis, S. E. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.035 · Cited by 136
Self-citationThe oxidizing effect of humidity on WO3 based sensors
Staerz, A., Berthold, C., Russ, T., Wicker, S., Weimar, U., & Bârsan, N. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.06.072 · Cited by 135
Precision medicine: the foundation of future cancer therapeutics
Shin, S. H., Bode, A. M., & Dong, Z. (2017) · npj Precision Oncology · doi:10.1038/s41698-017-0016-z · Cited by 133
Noninvasive Body Fat Burn Monitoring from Exhaled Acetone with Si-doped WO3-sensing Nanoparticles
Güntner, A. T., Sievi, N. A., Theodore, S. J., Gulich, T., Kohler, M., & Pratsinis, S. E. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02843 · Cited by 129
Self-citationCorrelations between blood glucose and breath components from portable gas sensors and PTR-TOF-MS
Righettoni, M., Schmid, A., Amann, A., & Pratsinis, S. E. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037110 · Cited by 128
Self-citationHighly Selective and Rapid Breath Isoprene Sensing Enabled by Activated Alumina Filter
van den Broek, J., Güntner, A. T., & Pratsinis, S. E. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00976 · Cited by 128
Self-citationThe promise and peril of universal health care
Bloom, D. E., Khoury, A. F., & Subbaraman, R. (2018) · Science · doi:10.1126/science.aat9644 · Cited by 128
Breath hydrogen response to lactulose in healthy subjects: relationship to methane producing status.
Cloarec, D., Bornet, F. R. J., Gouilloud, S., Barry, J. L., Salim, B., & Galmiche, J. P. (1990) · Gut · doi:10.1136/gut.31.3.300 · Cited by 126
Hibbard, T., Crowley, K., Kelly, F., Ward, F. L., Holian, J., Watson, A., & Killard, A. J. (2013) · Analytical Chemistry · doi:10.1021/ac403472d · Cited by 124
Sniffing Entrapped Humans with Sensor Arrays
Güntner, A. T., Pineau, N. J., Mochalski, P., Wiesenhofer, H., Agapiou, A., Mayhew, C. A., & Pratsinis, S. E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00237 · Cited by 122
Self-citationBimodally Porous WO 3 Microbelts Functionalized with Pt Catalysts for Selective H 2 S Sensors
Kim, M.-H., Jang, J., Koo, W., Choi, S., Kim, S., Kim, D., & Kim, I. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b00588 · Cited by 113
Ferrus, L., Guénard, H. J.-P., Vardon, G., & Varène, P. (1980) · Respiration Physiology · doi:10.1016/0034-5687(80)90067-5 · Cited by 112
Paredi, P., Kharitonov, S. A., LEAK, D., Shah, P. L., Cramer, D., Hodson, M. E., & Barnes, P. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.4.9906122 · Cited by 110
Breath acetone predicts plasma ketone bodies in children with epilepsy on a ketogenic diet
Musa‐Veloso, K., Likhodii, S. S., Rarama, E., Benoit, S., Liu, Y.-M. C., Chartrand, D. J., Curtis, R., Carmant, L., Lortie, A., Comeau, F. J. E., et al. (2005) · Nutrition · doi:10.1016/j.nut.2005.04.008 · Cited by 109
Stabilization of SnO2 ultrafine particles by additives
Xu, C., Tamaki, J., Miura, N., & Yamazoe, N. (1992) · Journal of Materials Science · doi:10.1007/bf01197649 · Cited by 108
New Digital Metal-Oxide (MOx) Sensor Platform
Rüffer, D., Hoehne, F., & Bühler, J. (2018) · Sensors · doi:10.3390/s18041052 · Cited by 108
Smith, D. C., Wang, T., Pysanenko, A., & Španěl, P. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3434 · Cited by 105
Smith, D. C., Španěl, P., Enderby, B., Lenney, W., Turner, C., & Davies, S. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/4/1/017101 · Cited by 101
King, J., Mochalski, P., Unterkofler, K., Teschl, G., Klieber, M., Stein, M., Amann, A., & Baumann, M. (2012) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2012.05.159 · Cited by 99
Exhaled Isoprene and Acetone in Newborn Infants and in Children with Diabetes Mellitus
Nelson, N., Lagesson, V., Nosratabadi, A. R., Ludvigsson, J., & Tagesson, C. (1998) · Pediatric Research · doi:10.1203/00006450-199809000-00016 · Cited by 98
Buffered end-tidal (BET) sampling—a novel method for real-time breath-gas analysis
Herbig, J., Titzmann, T., Beauchamp, J. D., Kohl, I., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037008 · Cited by 97
Medical applications of breath hydrogen measurements
Shin, W. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7606-6 · Cited by 97
Dai, M., Lin, Y.-L., Lin, H.-C., Zan, H., Chang, K.-T., Meng, H., Liao, J., Tsai, M., & Cheng, H. (2013) · Analytical Chemistry · doi:10.1021/ac303100k · Cited by 95
Guiding Ketogenic Diet with Breath Acetone Sensors
Güntner, A. T., Kompalla, J. F., Landis, H., Theodore, S. J., Geidl, B., Sievi, N. A., Kohler, M., Pratsinis, S. E., & Gerber, P. A. (2018) · Sensors · doi:10.3390/s18113655 · Cited by 91
Self-citationMonitoring ammonia to assess halitosis
Amano, A., Yoshida, Y., Oho, T., & Koga, T. (2002) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1067/moe.2002.126911 · Cited by 81
Itoh, T., Miwa, T., Tsuruta, A., Akamatsu, T., Izu, N., Shin, W., Jangchul, P., Hida, T., Eda, T., & Setoguchi, Y. (2016) · Sensors · doi:10.3390/s16111891 · Cited by 80
Ultra-low power operation of self-heated, suspended carbon nanotube gas sensors
Chikkadi, K., Muoth, M., Maiwald, V., Roman, C. I., & Hierold, C. (2013) · Applied Physics Letters · doi:10.1063/1.4836415 · Cited by 78
Long, H., Harley‐Trochimczyk, A., He, T., Pham, T., Tang, Z., Shi, T., Zettl, A. K., Mickelson, W., Carraro, C., & Maboudian, R. (2016) · ACS Sensors · doi:10.1021/acssensors.5b00302 · Cited by 75
Analysis of expired air of fasting male monks at Mount Athos
Statheropoulos, M. K., Agapiou, A., & Georgiadou, A. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.01.017 · Cited by 71
Sukul, P., Schubert, J. K., Oertel, P., Kamysek, S., Taunk, K., Trefz, P., & Miekisch, W. (2016) · Scientific Reports · doi:10.1038/srep28029 · Cited by 66
Monitoring Diurnal Changes in Exhaled Human Breath
Sinues, P., Kohler, M., & Zenobi, R. (2012) · Analytical Chemistry · doi:10.1021/ac3029097 · Cited by 60
Chen, W., Laiho, S., Vaittinen, O., Halonen, L., Ortiz, F., Forsblom, C. M., Groop, P., Lehto, M. J., & Metsälä, M. (2016) · Journal of Breath Research · doi:10.1088/1752-7155/10/3/036011 · Cited by 60
Breath-Ammonia Testing of Healthy Subjects and Patients with Cirrhosis
Adrover, R., Cocozzella, D., Ridruejo, E., Garcia, A. Y., Romé, J., & Podestá, J. J. (2011) · Digestive Diseases and Sciences · doi:10.1007/s10620-011-1858-9 · Cited by 59
Metabolic monitoring and assessment of anaerobic threshold by means of breath biomarkers
Schubert, R., Schwoebel, H., Mau‐Moeller, A., Behrens, M., Fuchs, P., Sklorz, M., Schubert, J. K., Bruhn, S., & Miekisch, W. (2012) · Metabolomics · doi:10.1007/s11306-012-0408-6 · Cited by 58
Monitoring breath markers under controlled conditions
Righettoni, M., Ragnoni, A., Güntner, A. T., Loccioni, C., Pratsinis, S. E., & Risby, T. H. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/4/047101 · Cited by 55
Self-citationVersatile breath sampler for online gas sensor analysis
Schon, S., Theodore, S. J., & Güntner, A. T. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.094 · Cited by 54
Self-citationOrthogonal gas sensor arrays by chemoresistive material design
Pineau, N. J., Kompalla, J. F., Güntner, A. T., & Pratsinis, S. E. (2018) · Microchimica Acta · doi:10.1007/s00604-018-3104-z · Cited by 49
Self-citationMass-Spectrometric Detection of Omega-Oxidation Products of Aliphatic Fatty Acids in Exhaled Breath
Gaugg, M. T., Bruderer, T., Nowak, N., Eiffert, L., Sinues, P., Kohler, M., & Zenobi, R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02092 · Cited by 48
Bogen, E. (1927) · JAMA · doi:10.1001/jama.1927.02690180040011 · Cited by 47
Metabolite Content Profiling of Bottlenose Dolphin Exhaled Breath
Aksenov, A. A., Yeates, L. C., Pasamontes, A., Siebe, C., Zrodnikov, Y., Simmons, J., McCartney, M. M., Deplanque, J.-P., Wells, R. S., & Davis, C. E. (2014) · Analytical Chemistry · doi:10.1021/ac5024217 · Cited by 47
Insulin resistance: Is it time for primary prevention?
Mercurio, V., Carlomagno, G., Fazio, V., & Fazio, S. (2012) · World Journal of Cardiology · doi:10.4330/wjc.v4.i1.1 · Cited by 46
What is the real utility of breath ammonia concentration measurements in medicine and physiology?*
Španěl, P., & Smith, D. C. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa907f · Cited by 46
Implementation of Fowler's method for end-tidal air sampling
Francesco, F. D., Loccioni, C., Fioravanti, M., Russo, A., Pioggia, G., Ferro, M., Roehrer, I., Tabucchi, S., & Onor, M. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037009 · Cited by 44
Hrachowina, L., Domènech-Gil, G., Pardo, A., Seifner, M. S., Gràcia, I., Cane, C., Romano-Rodriguez, A., & Barth, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00073 · Cited by 36
Medical Sensors for the Diagnosis and Management of Disease: The Physician Perspective
Pendley, B. D., & Lindner, E. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00642 · Cited by 26
Kraniotou, C., Karadima, V., Bellos, G., & Tsangaris, G. T. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2018.03.004 · Cited by 22
Influence of cycle exercise on acetone in expired air and skin gas
Yamai, K., Ohkuwa, T., Itoh, H., Yamazaki, Y., & Tsuda, T. (2009) · Redox Report · doi:10.1179/135100009x12525712409850 · Cited by 16
Boshier, P. R., Fehervari, M., Markar, S. R., Purkayastha, S., Španěl, P., Smith, D. C., & Hanna, G. B. (2018) · Obesity Surgery · doi:10.1007/s11695-018-3180-5 · Cited by 11
Increase in breath hydrogen concentration was correlated with the main pancreatic duct stenosis
Sakai, D., Hirooka, Y., Kawashima, H., Ohno, E., Ishikawa, T., Suhara, H., Takeyama, T., Koya, T., Tanaka, H., Iida, T., et al. (2018) · Journal of Breath Research · doi:10.1088/1752-7163/aaaf77 · Cited by 11
Measurement of breath acetone in patients referred for an oral glucose tolerance test
Andrews, B. T. E., Denzer, W., Hancock, G., Lunn, A. D., Peverall, R., Ritchie, G. A. D., & Williams, K. (2018) · Journal of Breath Research · doi:10.1088/1752-7163/aabd88 · Cited by 10
Predicting therapeutic weight loss
Finer, N. (2015) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.114.106195 · Cited by 7
Cited by
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Self-citationJeong, S., Kim, J., & Lee, J. (2020) · Advanced Materials · doi:10.1002/adma.202002075 · Cited by 415
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Highly selective detection of methanol over ethanol by a handheld gas sensor
van den Broek, J., Abegg, S., Pratsinis, S. E., & Güntner, A. T. (2019) · Nature Communications · doi:10.1038/s41467-019-12223-4 · Cited by 378
Self-citationPorous materials as effective chemiresistive gas sensors
Sharma, A., Eadi, S. B., Noothalapati, H., Otyepka, M., Lee, H.-D., & Jayaramulu, K. (2024) · Chemical Society Reviews · doi:10.1039/d2cs00761d · Cited by 352
Metadata
- Authors
- Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-01-09
- Volume
- 4
- Issue
- 2
- Pages
- 268-280
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2910800791
- Cited by
- 410
- References
- 126
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.