Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Experimental conditions in the continuous DIB device promote rapid transport equilibration between droplet compartments due to the inherent recirculating flow found in droplets.28,29”
From Chiral lipid bilayers are enantioselectively permeable (2021) · doi:10.1038/s41557-021-00708-z · cites this paper as [28]
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationRaines, R. T. (1998) · Chemical Reviews · doi:10.1021/cr960427h · Cited by 937
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Leach, C. L., Greenspan, J. S., Rubenstein, S. D., Shaffer, T. H., Wolfson, M. R., Jackson, J. C., DeLemos, R., & Fuhrman, B. P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609123351101 · Cited by 453
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citation
Research works printed but not linked: 19
- Shastry M. C. R., 1998, Biophys. J., 74, 2721
- Tice J. D., 2003, Langmuir, 19, 9133
- Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
- Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
- Ali J. A., 1997, Science, 275, 380
- Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
- Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
- Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
- Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
- Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
- Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
- Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
- Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
- Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
- Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
- Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
- Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
- Haykin S., 1994, Neural Networks
- Song H., 2003, Appl. Phys. Lett.
Cited by
Items 301–400 of 692
Ultrafast active mixer using polyelectrolytic ion extractor
Chun, H., Kim, H. C., & Chung, T. D. (2008) · Lab on a Chip · doi:10.1039/b715229a · Cited by 38
Zhao, S., Wang, W., Zhang, M., Shao, T., Jin, Y., & Cheng, Y. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.06.098 · Cited by 38
“At present, droplet-based microfluidics has been successfully applied to a wide variety of areas, such as enzymatic kinetics [3,4], protein crystallization [5,6] and chemical or biological synthesis [7,8].”
MethodControllable Preparation of Monodispersed Calcium Alginate Microbeads in a Novel Microfluidic System
Xu, J., Li, S. W., Tan, J., & Luo, G. (2008) · Chemical Engineering & Technology · doi:10.1002/ceat.200800027 · Cited by 38
Boedicker, J. Q., Vincent, M. E., & Ismagilov, R. F. (2009) · Angewandte Chemie · doi:10.1002/ange.200901550 · Cited by 38
Self-citationIversen, L., Cherouati, N., Berthing, T., Stamou, D. G., & Martinez, K. L. (2008) · Langmuir · doi:10.1021/la7037075 · Cited by 37
High-efficiency nano/micro-reactors for protein analysis
Li, Y., Yan, L., Liu, Y., Qian, K., Liu, B., Yang, P., & Liu, B. (2014) · RSC Advances · doi:10.1039/c4ra12333f · Cited by 38
Tan, J., Du, L., Lü, Y., Xu, J., & Luo, G. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.05.060 · Cited by 37
Cavity-enhanced optical methods for online microfluidic analysis
Rushworth, C. M., Davies, J., Cabral, J. T., Dolan, P. R., Smith, J. M., & Vallance, C. (2012) · Chemical Physics Letters · doi:10.1016/j.cplett.2012.10.009 · Cited by 37
“sis of nanoparticles [112], cell encapsulation [113], and reaction kinetics studies [114, 115, 13, 116].”
BackgroundPaul, S., Stang, A., Lennartz, K., Tenbusch, M., & Überla, K. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks940 · Cited by 40
“It should also be feasible to transfer the protein and DNA loaded beads recovered from the IVTT emulsion to cell-like microcapsules for independent enzymatic screening reactions and subsequent microfluidic selection methods (28,29) extending the potential applicability of the multi-copy bead display to all kind of enz…”
MethodFidalgo, L. M., Whyte, G., Ruotolo, B. T., Benesch, J. L. P., Stengel, F., Abell, C., Robinson, C. V., & Huck, W. T. S. (2009) · Angewandte Chemie · doi:10.1002/ange.200806103 · Cited by 37
Enzyme hydrolysis of soybean oil in a slug flow microsystem
Čech, J., Schrott, W., Slouka, Z., Přibyl, M., Brož, M., Kuncová, G., & Šnita, D. (2012) · Biochemical Engineering Journal · doi:10.1016/j.bej.2012.06.015 · Cited by 36
Experimental Investigation of Inertial Mixing in Colliding Droplets
Carroll, B., & HIDROVO, C. H. (2012) · Heat Transfer Engineering · doi:10.1080/01457632.2013.703087 · Cited by 36
“Heat Transfer Engineering, 34(2–3):120–130, 2013 Copyright C© Taylor and Francis Group, LLC ISSN: 0145-7632 print / 1521-0537 online DOI: 10.1080/01457632.2013.703087 Experimental Investigation of Inertial”
BackgroundInfluentialSun, H., Zheng, H., Tang, Q., Dong, Y., Qu, F., Wang, Y., Yang, G., & Meng, T. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b12479 · Cited by 36
Probst, J., Borca, C. N., Newton, M. A., van Bokhoven, J. A., Huthwelker, T., Stavrakis, S., & deMello, A. J. (2021) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.1c00005 · Cited by 34
Insights into the “free state” enzyme reaction kinetics in nanoconfinement
Wang, C., Ye, D.-K., Wang, Y., Lu, T., & Xia, X. (2013) · Lab on a Chip · doi:10.1039/c3lc41319e · Cited by 36
Tostado, C. P., Xu, J., & Luo, G. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.05.043 · Cited by 36
Effect of diffusion on enzyme activity in a microreactor
Swarts, J. W., Kolfschoten, R. C., Eerten-Jansen, M. C. A. A. V., Janssen, A. E. M., & Boom, R. M. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2010.04.040 · Cited by 36
An automated flow chemistry platform to decouple mixing and reaction times
Epps, R. W., Volk, A. A., Abdel-latif, K., & Abolhasani, M. (2020) · Reaction Chemistry & Engineering · doi:10.1039/d0re00129e · Cited by 17
A Systematic Review of Enzymatic Kinetics in Microreactors
Cvetnić, T. S., Šalić, A., Benković, M., Jurina, T., Valinger, D., Kljusurić, J. G., Zelić, B., & Tušek, A. J. (2023) · Catalysts · doi:10.3390/catal13040708 · Cited by 35
“Enzymes can be denatured by high pH [18,103,104].”
BackgroundDynamics of counterion-induced attraction between vimentin filaments followed in microfluidic drops
Dammann, C., & Köster, S. (2014) · Lab on a Chip · doi:10.1039/c3lc51418h · Cited by 39
Pompano, R. R., Li, H., & Ismagilov, R. F. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.129486 · Cited by 42
“These results indicate that mixing should be considered ( 55 ) when describing the kinetics of autocatalytic biological systems.”
BackgroundSelf-citationGuan, X., Hou, L., Ren, Y., Deng, X., Lang, Q., Jia, Y., Hu, Q., Tao, Y., Liu, J., & Jiang, H. (2016) · Biomicrofluidics · doi:10.1063/1.4952572 · Cited by 35
Pei, J., Nie, J., & Kennedy, R. T. (2010) · Analytical Chemistry · doi:10.1021/ac101755y · Cited by 34
VanDelinder, V., Ferreon, A. C. M., Gambin, Y., Deniz, A. A., & Groisman, A. (2009) · Analytical Chemistry · doi:10.1021/ac901008c · Cited by 34
Rapid large area fabrication of multiscale through-hole membranes
Tahk, D., Paik, S., Lim, J., Bang, S., Oh, S., Ryu, H., & Jeon, N. L. (2017) · Lab on a Chip · doi:10.1039/c7lc00363c · Cited by 34
Remote Radio‐Frequency Controlled Nanoliter Chemistry and Chemical Delivery on Substrates
Ye, H., Randall, C. L., Leong, T. G., Slanac, D. A., Call, E. K., & Gracias, D. H. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604414 · Cited by 34
Fluid displacement during droplet formation at microfluidic flow-focusing junctions
Huang, H., & He, X. (2015) · Lab on a Chip · doi:10.1039/c5lc00730e · Cited by 34
Measuring rapid kinetics by a potentiometric method in droplet-based microfluidic devices
Han, Z., Chang, Y., Au, S. W. N., & Zheng, B. (2011) · Chemical Communications · doi:10.1039/c1cc12383a · Cited by 33
Surfactant‐free microdispersion process of gas in organic solvents in microfluidic devices
Tan, J., Du, L., Xu, J., Wang, K., & Luo, G. (2010) · AIChE Journal · doi:10.1002/aic.12487 · Cited by 33
IR-Compatible PDMS microfluidic devices for monitoring of enzyme kinetics
Srisa‐Art, M., Noblitt, S. D., Krummel, A. T., & Henry, C. S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.03.006 · Cited by 33
Microfluidic Valves for Selective on-Chip Droplet Splitting at Multiple Sites
Agnihotri, S. N., Raveshi, M. R., Bhardwaj, R., & Neild, A. (2020) · Langmuir · doi:10.1021/acs.langmuir.9b03515 · Cited by 33
Small Molecule Library Synthesis Using Segmented Flow
Thompson, C. M., Poole, J. L., Cross, J. L., Akritopoulou‐Zanze, I., & Djurić, S. W. (2011) · Molecules · doi:10.3390/molecules16119161 · Cited by 33
“Plug flow has also been successfully applied to protein crystallization [15], measurement of reaction kinetics [16], and high-throughput screening [17-19].”
Subsecond Electrophoretic Separations from Droplet Samples for Screening of Enzyme Modulators
Guetschow, E. D., Steyer, D. J., & Kennedy, R. T. (2014) · Analytical Chemistry · doi:10.1021/ac502758h · Cited by 33
Comparison of separation performance of laser-ablated and wet-etched microfluidic devices
Baker, C. A., Bulloch, R. H., & Roper, M. G. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4144-3 · Cited by 32
Sequential microfluidic droplet processing for rapid DNA extraction
Pan, X., Zeng, S., Zhang, Q., Lin, B., & Qin, J. (2011) · Electrophoresis · doi:10.1002/elps.201100078 · Cited by 32
Nanoconfinement Effects: Glucose Oxidase Reaction Kinetics in Nanofluidics
Wang, C., Sheng, Z., Ouyang, J., Xu, J., Chen, H., & Xia, X. (2012) · ChemPhysChem · doi:10.1002/cphc.201100842 · Cited by 32
Microfluidic Selective Concentration of Microdroplet Contents by Spontaneous Emulsification
Fukuyama, M., & Hibara, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00155 · Cited by 32
Droplet Manipulation Using Acoustic Streaming Induced by a Vibrating Membrane
Phan, H. V., Alan, T., & Neild, A. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04481 · Cited by 32
Microdroplet formation in rounded flow-focusing junctions
Gulati, S., Vijayakumar, K., Good, W. W., Tamayo, W., Patel, A. R., & Niu, X. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-015-1680-3 · Cited by 32
Li, X., He, Z., Li, C., & Li, P. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338677 · Cited by 31
Peclet Number Dependence of Mass Transfer in Microscale Segmented Gas–Liquid Flow
Abolhasani, M., Kumacheva, E., & Günther, A. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.5b01991 · Cited by 31
Droplet microfluidics based microseparation systems
Xiao, Z., Niu, M., & Zhang, B. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200115 · Cited by 30
Chung, C., Ahn, K. H., & Lee, S. J. (2009) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/j.jnnfm.2009.05.005 · Cited by 30
Experimental and numerical study of mixing behavior inside droplets in microchannels
Wang, W.-T., Shao, T., Zhao, S.-F., Jin, Y., & Cheng, Y. (2013) · AIChE Journal · doi:10.1002/aic.13945 · Cited by 26
Bauer, W. C., Kotar, J., Cicuta, P., Woodward, R. T., Weaver, J. V. M., & Huck, W. T. S. (2011) · Soft Matter · doi:10.1039/c1sm05087g · Cited by 30
Zhao, K., & Li, D. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.10.073 · Cited by 30
Villois, A., Palmiero, U. C., Mathur, P., Perone, G., Schneider, T. N., Li, L., Salvalaglio, M., deMello, A. J., Stavrakis, S., & Arosio, P. (2022) · Small · doi:10.1002/smll.202202606 · Cited by 32
Mechano‐Driven Tribo‐Electrophoresis Enabled Human–Droplet Interaction in 3D Space
Sun, J., Zhang, L., Gong, S., Chen, J., & Guo, H. (2023) · Advanced Materials · doi:10.1002/adma.202305578 · Cited by 29
Filla, L. A., Kirkpatrick, D. C., & Martin, R. S. (2011) · Analytical Chemistry · doi:10.1021/ac201007s · Cited by 29
Numerical simulation of droplet formation in a micro-channel using the lattice Boltzmann method
Kim, L. S., Jeong, H. K., Ha, M. Y., & Kim, K. C. (2008) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-007-1201-8 · Cited by 30
“Some experimental studies to investigate the characteristics of microdroplets formed in the micro-channel have been reported [ 1-8 ].”
BackgroundKinetic study of reactions of aniline and benzoyl chloride in a microstructured chemical system
Wang, P., Wang, K., Zhang, J., & Luo, G. (2015) · AIChE Journal · doi:10.1002/aic.14891 · Cited by 29
Thermoformed fluoropolymer tubing for in-line mixing
Wang, K., Zhang, H.-M., Shen, Y., Adamo, A., & Jensen, K. (2018) · Reaction Chemistry & Engineering · doi:10.1039/c8re00112j · Cited by 22
Droplet Microfluidics for Single-Cell Analysis
Brouzes, E. R. (2012) · Methods in molecular biology · doi:10.1007/978-1-61779-567-1_10 · Cited by 29
Vimentin networks at tunable ion-concentration in microfluidic drops
Dammann, C., Nöding, B., & Köster, S. (2012) · Biomicrofluidics · doi:10.1063/1.4705103 · Cited by 28
Droplet‐based microfluidics for microtoxicological studies
Cao, J., & Köhler, J. M. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201400074 · Cited by 28
“T-junction Premixing 20 Hz Kinetic measurement Up to 2 orders of magnitude [51] 2003 Dilution About 1 Hz Enzyme inhibition assays 1–3 orders of magnitude [59] 2013 Split and merge 0.”
MethodBreaking Anchored Droplets in a Microfluidic Hele-Shaw Cell
Amselem, G., Brun, P. ‐., Gallaire, F., & Baroud, C. N. (2015) · Physical Review Applied · doi:10.1103/physrevapplied.3.054006 · Cited by 28
“Studying the contents of these drops [2,3] is, therefore, more akin to flow cytometry than to multiwell plates.”
BackgroundMillisecond-order rapid micromixing with non-equilibrium electrokinetic phenomena
Lee, S. J., & Kim, D. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-011-0918-y · Cited by 29
“…a chaotic bubble mixer which enables mixing within 20 ms. Ahmed et al. (2009) reported a microfluidic mixer with a single bubble-based acoustic streaming with mixing in 7 ms and Song and Ismagilov (2003) proposed a microfluidic chip with mixing capacity in order of 1 ms using nanoliters of sample.”
MethodZhang, K., Liang, Q., Ai, X., Hu, P., Wang, Y., & Luo, G. (2011) · Analytical Chemistry · doi:10.1021/ac2017458 · Cited by 28
Fu, Y., Wang, H., Zhang, X., Bai, L., Jin, Y., & Cheng, Y. (2018) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2018.08.025 · Cited by 28
Real-time monitoring of suspension cell–cell communication using an integrated microfluidics
Xu, T., Yue, W., Li, C., Yao, X., Cai, G., & Yang, M. (2010) · Lab on a Chip · doi:10.1039/c004844e · Cited by 27
Mohr, S., Fisher, K., Scrutton, N. S., Goddard, N. J., & Fielden, P. R. (2010) · Lab on a Chip · doi:10.1039/c003561k · Cited by 27
Liu, X., Li, X., Wu, N., Luo, Y., Zhang, J., Yu, Z., & Shen, F. (2022) · ACS Sensors · doi:10.1021/acssensors.2c00734 · Cited by 31
In-depth analysis of biocatalysts by microfluidics: An emerging source of data for machine learning
Vasina, M., Kovar, D. R., Damborský, J., Ding, Y., Yang, T., deMello, A. J., Mazurenko, S., Stavrakis, S., & Prokop, Z. (2023) · Biotechnology Advances · doi:10.1016/j.biotechadv.2023.108171 · Cited by 28
“One of the early attempts to use droplet microfluidics to study enzymatic reaction was shown by Song et al. (Song and Ismagilov, 2003).”
Optimisation of a microfluidic analysis chamber for the placement of microelectrodes
Rogers, M. L., Leong, C. L., Niu, X., deMello, A. J., Parker, K. H., & Boutelle, M. G. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c0cp02810j · Cited by 31
Investigating slippage, droplet breakup, and synthesizing microcapsules in microfluidic systems
Tabeling, P. (2010) · Physics of Fluids · doi:10.1063/1.3323086 · Cited by 27
Basic Technologies for Droplet Microfluidics
Zeng, S., Liu, X., Xie, H., & Lin, B. (2011) · Topics in current chemistry · doi:10.1007/128_2011_149 · Cited by 27
Sun, M., & Vanapalli, S. A. (2013) · Analytical Chemistry · doi:10.1021/ac303526y · Cited by 26
Separation of magnetic microparticles in segmented flow using asymmetric splitting regimes
Verbruggen, B., Tóth, T., Cornaglia, M., Puers, R., Gijs, M. A. M., & Lammertyn, J. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-014-1409-8 · Cited by 26
“Most current assays use either on-chip detection with optical techniques or off-chip detection with traditional analytical methods (Song and Ismagilov 2003; Teh et al. 2008).”
MethodSelective DNA extraction with microparticles in segmented flow
Verbruggen, B., Leirs, K., Puers, R., & Lammertyn, J. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-014-1433-8 · Cited by 26
“Many discrete repetitions allow for statistical information at an unseen short timescale (Song and Ismagilov 2003).”
BackgroundA large-scale on-chip droplet incubation chamber enables equal microbial culture time
Dai, J. H., Kim, H. S., Guzman, A. R., Shim, W., & Han, A. (2016) · RSC Advances · doi:10.1039/c5ra26505c · Cited by 26
Tan, J., Dong, C., Lü, Y., Xu, J., & Luo, G. (2011) · Industrial & Engineering Chemistry Research · doi:10.1021/ie2010302 · Cited by 26
Zha, L., Shang, M., Qiu, M., Zhang, H., & Su, Y. (2018) · Chemical Engineering Science · doi:10.1016/j.ces.2018.11.043 · Cited by 26
Jagadeesan, D., Mansoori, U., Mandal, P., Sundaresan, A., & Eswaramoorthy, M. (2008) · Angewandte Chemie · doi:10.1002/ange.200802626 · Cited by 26
Broad-Band Spectrum, High-Sensitivity Absorbance Spectroscopy in Picoliter Volumes
Probst, J., Howes, P. D., Arosio, P., Stavrakis, S., & deMello, A. J. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00587 · Cited by 25
Droplets and jets in microfluidic devices
Guillot, P., Ajdari, A., Goyon, J., Joanicot, M., & Colin, A. (2008) · Comptes Rendus Chimie · doi:10.1016/j.crci.2008.07.005 · Cited by 25
Chen, Z., Sang, F., Xu, J., Luo, G., & Wang, Y. (2018) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2018.03.004 · Cited by 25
Harnessing elastic instabilities for enhanced mixing and reaction kinetics in porous media
Browne, C. A., & Datta, S. (2023) · Proceedings of the National Academy of Sciences of the United States of America · doi:10.1073/pnas.2320962121 · Cited by 28
“Thus, integrating over all well-mixed parcels of fluid gives the macro-scale conversion [70, 87]: , where 𝐻 is the Heaviside function, which ultimately yields Eq.”
BackgroundInternal flow in droplets within a concentrated emulsion flowing in a microchannel
Leong, C. M., Gai, Y., & Tang, S. K. Y. (2016) · Physics of Fluids · doi:10.1063/1.4968526 · Cited by 27
Echelmeier, A., Kim, D., Villarreal, J. C., Coe, J. D., Quintana, S., Brehm, G., Egatz-Gómez, A., Nazari, R., Sierra, R. G., Koglin, J. E., et al. (2019) · Journal of Applied Crystallography · doi:10.1107/s1600576719010343 · Cited by 24
“…geometry because of its simplicity and well characterized droplet formation physical parameters (Thorsen et al., 2001; Nisisako et al., 2002; Zheng et al., 2003; Song & Ismagilov, 2003; Song et al., 2003; Li & Ismagilov, 2010; Garstecki et al., 2006; Husny & Cooper-White, 2006; Zhu & Wang, 2016).”
BackgroundUV-ablation nanochannels in micro/nanofluidics devices for biochemical analysis
Wang, C., Ouyang, J., Gao, H., Chen, H., Xu, J., Xia, X., & Chen, H. (2011) · Talanta · doi:10.1016/j.talanta.2011.03.057 · Cited by 23
Statistics of droplet sizes generated by a microfluidic device
Prileszky, T. A., Ogunnaike, B. A., & Furst, E. M. (2016) · AIChE Journal · doi:10.1002/aic.15246 · Cited by 23
Scaling of mixing time for droplets of different sizes traveling through a serpentine microchannel
Harshe, Y. M., van Eijk, M. J., Kleijn, C. R., Kreutzer, M. T., & Boukany, P. E. (2016) · RSC Advances · doi:10.1039/c6ra17728j · Cited by 23
Hu, J., Li, X., Judd, R. L., & Easley, C. J. (2020) · Lab on a Chip · doi:10.1039/d0lc00103a · Cited by 23
Electrical Control of Individual Droplet Breaking and Droplet Contents Extraction
Zeng, S., Pan, X., Zhang, Q., Lin, B., & Qin, J. (2011) · Analytical Chemistry · doi:10.1021/ac1028775 · Cited by 23
Microvalves for integrated selective droplet generation, splitting and merging on a chip
Agnihotri, S. N., Raveshi, M. R., Bhardwaj, R., & Neild, A. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02487-y · Cited by 22
Imaging of Chemical Kinetics at the Water–Water Interface in a Free-Flowing Liquid Flat-Jet
Schewe, H. C., Credidio, B., Ghrist, A. M., Malerz, S., Ozga, C., Knie, A., Haak, H., Meijer, G., Winter, B. J., & Osterwalder, A. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c01232 · Cited by 23
Cheng, Z., Du, M., Lai, H., Du, Y., Zhang, N., & Sun, K. (2013) · Chemistry - An Asian Journal · doi:10.1002/asia.201300941 · Cited by 22
Highly reproducible chronoamperometric analysis in microdroplets
Liu, H., & Crooks, R. M. (2013) · Lab on a Chip · doi:10.1039/c3lc41263f · Cited by 22
Microfluidic protein crystallisation controlled using spontaneous emulsification
Fukuyama, M., Akiyama, A., Harada, M., Okada, T., & Hibara, A. (2015) · Analytical Methods · doi:10.1039/c5ay00578g · Cited by 22
Integrated pneumatic micro-pumps for high-throughput droplet-based microfluidics
Choi, J.-W., Lee, S., Lee, D. H., Kim, J., deMello, A. J., & Chang, S. (2014) · RSC Advances · doi:10.1039/c4ra02033b · Cited by 22
Ke, X. U., Zhu, P., Colon, T., Huh, C., & Balhoff, M. (2016) · SPE Improved Oil Recovery Conference · doi:10.2118/179691-ms · Cited by 22
Hou, L., Ren, Y., Jia, Y., Deng, X., Tang, Z., Tao, Y., & Jiang, H. (2017) · Analytical Methods · doi:10.1039/c7ay00544j · Cited by 22
Predictive model for the scale-out of small channel two-phase flow contactors
Ortega, E. G., Tsaoulidis, D. A., & Angeli, P. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.06.020 · Cited by 22
“Over the last few years there have been many studies on small-scale units aiming at the intensification of multiphase processes, including (bio)chemical syntheses [1,2], absorptions [3], extractions [4,5], and (nano)crystallisations [6].”
BackgroundOSTE+ for in situ SAXS analysis with droplet microfluidic devices
Lange, T., Charton, S., Bizien, T., Testard, F., & Malloggi, F. (2020) · Lab on a Chip · doi:10.1039/d0lc00454e · Cited by 22
Polydopamine Microfluidic System toward a Two‐Dimensional, Gravity‐Driven Mixing Device
You, I., Kang, S. M., Lee, S., Cho, Y. O., Kim, J. B., Lee, S. B., Nam, Y. S., & Lee, H. (2012) · Angewandte Chemie · doi:10.1002/ange.201200329 · Cited by 21
Kurdadze, T., Lamadie, F., Nehme, K. A., Teychené, S., Biscans, B., & Rodríguez-Ruiz, I. (2024) · Sensors · doi:10.3390/s24051529 · Cited by 21
“For instance, Ismagilov and co-workers systematically investigated the mixing phenomena in droplets in both straight [46] and winding microchannels [47].”
BackgroundDroplet microfluidics for time-resolved serial crystallography
Stubbs, J., Hornsey, T., Hanrahan, N., Esteban, L. B., Bolton, R., Malý, M., Basu, S., Orlans, J., de Sanctis, D., Shim, J.-U., et al. (2024) · IUCrJ · doi:10.1107/s2052252524001799 · Cited by 24
Locally enhanced concentration and detection of oligonucleotides in a plug-based microfluidic device
Fang, W.-F., Ting, S.-C., Hsu, C.-W., Chen, Y.-T., & Yang, J. (2012) · Lab on a Chip · doi:10.1039/c2lc20917a · Cited by 22
Log-Scale Dose Response of Inhibitors on a Chip
Yun, J. Y., Jambovane, S. R., Kim, S., Cho, S.-H., Duin, E. C., & Hong, J. W. (2011) · Analytical Chemistry · doi:10.1021/ac201177g · Cited by 21
Photochemical Micro Continuous‐Flow Synthesis of Noble Metal Nanoparticles of the Platinum Group
Hafermann, L., & Köhler, J. M. (2015) · Chemical Engineering & Technology · doi:10.1002/ceat.201500029 · Cited by 21
Metadata
- Authors
- Song, H., & Ismagilov, R. F.
- Affiliations
- University of Chicago (US)
- ORCID
- Ismagilov, Rustem F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-29
- Volume
- 125
- Issue
- 47
- Pages
- 14613-14619
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- PMC
- PMC1769313
- OpenAlex
- W2028894110
- Cited by
- 693
- References
- 45
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM08720, T32GM008720)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
- MeSH terms
- Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.