Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Experimental conditions in the continuous DIB device promote rapid transport equilibration between droplet compartments due to the inherent recirculating flow found in droplets.28,29”
From Chiral lipid bilayers are enantioselectively permeable (2021) · doi:10.1038/s41557-021-00708-z · cites this paper as [28]
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationRaines, R. T. (1998) · Chemical Reviews · doi:10.1021/cr960427h · Cited by 937
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Leach, C. L., Greenspan, J. S., Rubenstein, S. D., Shaffer, T. H., Wolfson, M. R., Jackson, J. C., DeLemos, R., & Fuhrman, B. P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609123351101 · Cited by 453
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citation
Research works printed but not linked: 19
- Shastry M. C. R., 1998, Biophys. J., 74, 2721
- Tice J. D., 2003, Langmuir, 19, 9133
- Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
- Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
- Ali J. A., 1997, Science, 275, 380
- Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
- Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
- Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
- Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
- Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
- Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
- Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
- Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
- Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
- Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
- Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
- Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
- Haykin S., 1994, Neural Networks
- Song H., 2003, Appl. Phys. Lett.
Cited by
Items 501–600 of 692
Flow lines and mixing within drops in microcapillaries
Blanchette, F. (2009) · Physical Review E · doi:10.1103/physreve.80.066316 · Cited by 10
Micro segmented-flow in biochemical and cell-based assays
Merten, C. A. (2012) · Frontiers in Bioscience-Elite · doi:10.2741/e497 · Cited by 8
Ultra-microscale Chemistry Experiment on Microfluidic Devices: A New Trend in Chemical Education
Xu, C., Cai, L., & Huang, Z. (2024) · Journal of Chemical Education · doi:10.1021/acs.jchemed.3c01036 · Cited by 8
Internal circulation and mixing within tight-squeezing deformable droplets
Gissinger, J. R., Zinchenko, A. Z., & Davis, R. H. (2021) · Physical review. E · doi:10.1103/physreve.103.043106 · Cited by 9
Yang, T., Villois, A., Kunka, A., Grigolato, F., Arosio, P., Prokop, Z., deMello, A. J., & Stavrakis, S. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03009 · Cited by 8
A pneumatic valve controlled microdevice for bioanalysis
Zhou, X., Zhou, X., & Zheng, B. (2013) · Biomicrofluidics · doi:10.1063/1.4826158 · Cited by 8
De, A., & Mishra, S. K. (2013) · Computers & Fluids · doi:10.1016/j.compfluid.2013.10.041 · Cited by 8
Microfabrication and microfluidic devices for drug delivery
Kimura, N., Maeki, M., & Tokeshi, M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812659-2.00005-3 · Cited by 13
Nagaki, A., Jiang, Y., Yamashita, H., Takabayashi, N., Takahashi, Y., & Yoshida, J.-I. (2019) · Chemical Engineering & Technology · doi:10.1002/ceat.201900057 · Cited by 8
Leroy, A., Teixidor, J., Bertsch, A., & Renaud, P. (2021) · Lab on a Chip · doi:10.1039/d1lc00116g · Cited by 9
Hwang, J. W., Choi, J.-H., Choi, B., Lee, G., Lee, S. W., Koo, Y., & Chang, W.-J. (2015) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-015-0037-7 · Cited by 8
Microfluidic for Lab-on-a-Chip
Haeberle, S., & Zengerle, R. (2008) · Elsevier eBooks · doi:10.1016/b978-044452190-3.00038-0 · Cited by 8
Towards microfluidic technology-based MALDI-MS platforms for drug discovery: a review
Winkle, R. F., Nagy, J. M., Cass, A. E. G., & Sharma, S. (2008) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.3.11.1281 · Cited by 8
Remote Radio‐Frequency Controlled Nanoliter Chemistry and Chemical Delivery on Substrates
Ye, H., Randall, C. L., Leong, T. G., Slanac, D. A., Call, E. K., & Gracias, D. H. (2007) · Angewandte Chemie · doi:10.1002/ange.200604414 · Cited by 8
Phase compensation in single echo acquisition imaging
McDougall, M. P., & Wright, S. M. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1549725 · Cited by 9
“Simultaneously, the interest in imaging faster with MRI is escalating as dynamic and real-time applications become intertwined with the move towards molecular imaging [2]–[4].”
BackgroundAnagnostidis, V., Tiwari, A., & Gielen, F. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1364553 · Cited by 7
Dynamic behavior of floating ferrofluid droplet through an orifice with a magnetic field
Zhou, J., Yang, L., Wang, Y., Niu, X., Wu, J., Han, L., & Khan, A. (2024) · Computers & Fluids · doi:10.1016/j.compfluid.2024.106341 · Cited by 7
Electrowetting-Induced Coalescence of Sessile Droplets in Viscous Medium
Quintero, J. S. M., Majhy, B., Caesar, M., & Waghmare, P. R. (2023) · Langmuir · doi:10.1021/acs.langmuir.2c03194 · Cited by 7
Droplet-based Microfluidic Device for High-throughput Screening
Jeong, H., Noh, Y.-M., Jang, S., & Lee, C. (2014) · Korean Chemical Engineering Research · doi:10.9713/kcer.2014.52.2.141 · Cited by 7
ON-CHIP STORAGE OF DROPLETS IN PARYLENE-AF4 COATED PDMS CHANNELS
Akhtar, M., van den Driesche, S., & Vellekoop, M. J. (2014) · Cited by 7
Hsieh, K., Zec, H. C., Ma, P., Rane, T. D., & Wang, T. (2015) · Micromachines · doi:10.3390/mi6101434 · Cited by 7
“Recent years have seen the emergence of microfluidic droplet technology in a variety of chemical and biochemical applications [1,2], ranging from single-cell analysis [3–6] to enzyme kinetics measurements [7,8] and even nanoparticle synthesis [9–11].”
BackgroundMeasurement and enhancement of gas–liquid mass transfer in milliliter-scale slurry reactors
Fan, Y., & Herz, R. K. (2007) · Chemical Engineering Science · doi:10.1016/j.ces.2007.06.032 · Cited by 7
Fractal-shaped microchannel design for a kinetic analysis of biochemical reaction in a delay line
Hirata, K., Ichii, T., Suzuki, H., Matsuura, T., Hosoda, K., & Yomo, T. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0958-y · Cited by 7
Progress in Visualizing Turbulent Flow using Single-Echo Acquisition Imaging
Wright, S. M., McDougall, M. P., & Bosshard, J. C. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260797 · Cited by 7
“An extremely fast imaging technique could allow MRI of turbulent flow in stenotic vessels [4] and in microfluidic lab-on-a-chip devices where chaotic flow is desired for mixing [5, 6], or to follow millisecond kinetics in chemical reactions [ 7 ], or even to enable imaging of destructive events or single-shot imaging…”
BackgroundOn-demand light-driven release of droplets stabilized via a photoresponsive fluorosurfactant
Cheng, G., Xiao, Q., Kuan, C. Y., & Ho, Y. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00567-3 · Cited by 7
Elastomer Application in Microsystem and Microfluidics
Jake, S., & Jiang, K. (2012) · InTech eBooks · doi:10.5772/48121 · Cited by 7
Jankowski, P., Samborski, A., Ostaszewski, R., & Garstecki, P. (2019) · Preparative Biochemistry & Biotechnology · doi:10.1080/10826068.2019.1605527 · Cited by 7
“8mm) for rapid mixing.([18,26,27]) Before the mixer, the syringe filled with perfluorodecaline (placed on the syringe pump) was connected to the system.”
BackgroundMethodDroplet microfluidic chip for precise monitoring of dynamic solution changes
Ma, C., Gao, Z., Zhao, J., & Feng, S. (2023) · Nanotechnology and Precision Engineering · doi:10.1063/10.0019677 · Cited by 6
Ma, H., Ramanujam, A., Linnes, J. C., & Kinzer‐Ursem, T. L. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c04840 · Cited by 6
Development of Integrated Microfluidic Magnetic Bioprocessor for Multi-biomarker Detection
Jie, L. I. A. N., Wen-Wen, Z. H. O. U., Shi, X., & Gao, Y. (2013) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(13)60681-7 · Cited by 6
Rendl, M., Brandstëtter, T., & Rühe, J. (2013) · Analytical Chemistry · doi:10.1021/ac401752j · Cited by 6
Fitzgerald, S., & O’Shea, D. F. (2022) · Chemistry - A European Journal · doi:10.1002/chem.202104111 · Cited by 7
Kayirangwa, Y., Mohibullah, M., & Easley, C. J. (2023) · The Analyst · doi:10.1039/d3an01149f · Cited by 6
Microchannel edge refractometry
Marin, A., Joanicot, M., & Tabeling, P. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.04.028 · Cited by 6
Farka, Z., Mickert, M. J., Pastucha, M., Mikušová, Z., Skládal, P., & Gorris, H. H. (2019) · Angewandte Chemie · doi:10.1002/ange.201913924 · Cited by 6
Mixing Performance of Micromixers with Fractal Obstacles Based on Murray's Law
Hou, C., Li, L., Lv, R., Tian, Z., & Chen, X. (2021) · Chemical Engineering & Technology · doi:10.1002/ceat.202100047 · Cited by 6
Whole Cell Quenched Flow Analysis
Chiang, Y.-Y., Haeri, S., Gizewski, C., Stewart, J. D., Ehrhard, P., Shrimpton, J. S., Janasek, D., & West, J. J. (2013) · Analytical Chemistry · doi:10.1021/ac402881h · Cited by 6
Solid-Phase Extraction in Segmented Flow
Rendl, M., Brandstëtter, T., & Rühe, J. (2014) · Langmuir · doi:10.1021/la502645z · Cited by 6
Measurement of Protein–Protein Interaction Dynamics Using Microfluidics and Particle Diffusometry
Ma, H., Wereley, S. T., Linnes, J. C., & Kinzer‐Ursem, T. L. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02570 · Cited by 6
Weber, E., Puchberger-Enengl, D., & Vellekoop, M. J. (2012) · ASME 2012 10th International Conference on Nanochannels, Microchannels, and Minichannels collocated with the ASME 2012 Heat Transfer Summer Conference and the ASME 2012 Fluids Engineering Division Summer Meeting · doi:10.1115/icnmm2012-73155 · Cited by 5
Yu, J., Matthews, S. M., Yunus, K., Shapter, J. G., & Fisher, A. C. (2013) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)14270-2 · Cited by 5
Plateau–Rayleigh Instability in Soft-Lattice Inorganic Solids
Shao, Z., Jiang, X., Zhang, C., Wang, T., Wang, Y., Liu, G., Huang, Z., Zhang, Y.-Z., Wu, L., Hou, Z., et al. (2024) · Journal of the American Chemical Society · doi:10.1021/jacs.4c11866 · Cited by 5
Cavity Ringdown Spectroscopy for the Analysis of Small Liquid Volumes
Vallance, C., & Rushworth, C. M. (2013) · Springer series in optical sciences/SPringer series in optical sciences · doi:10.1007/978-3-642-40003-2_11 · Cited by 5
On-chip dilution in nanoliter droplets
Thakur, R., Amin, A. M., & Wereley, S. T. (2015) · The Analyst · doi:10.1039/c4an01829j · Cited by 5
A Microfluidic Chip for ICPMS Sample Introduction
Verboket, P. E., Borovinskaya, O., Meyer, N., Günther, D., & Dittrich, P. S. (2015) · Journal of Visualized Experiments · doi:10.3791/52525 · Cited by 5
Wang, P., Zhang, J., Wang, K., Luo, G., & Xie, P. (2016) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.6b00506 · Cited by 5
Strong rotating flow in stationary droplets in low power budget using wire electrode configuration
Kunti, G., Bhattacharya, A., & Chakraborty, S. K. (2019) · Electrophoresis · doi:10.1002/elps.201900272 · Cited by 5
Exploring early time points of vimentin assembly in flow by fluorescence fluctuation spectroscopy
Perego, E., & Köster, S. (2021) · Lab on a Chip · doi:10.1039/d0lc00985g · Cited by 5
Meier, M., Kennedy‐Darling, J., Choi, S. H., Norstrom, E. M., Sisodia, S. S., & Ismagilov, R. F. (2009) · Angewandte Chemie · doi:10.1002/ange.200805225 · Cited by 5
Self-citationDroplet evaporation on curved surfaces: transients of internal and external transport phenomena
Paul, A., Mondal, S., & Dhar, P. (2024) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2023.0613 · Cited by 5
Implications of variable fluid resistance caused by start-up flow in microfluidic networks
Zeitoun, R. I., Langelier, S. M., & Gill, R. T. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1241-6 · Cited by 5
“…of complex microfluidic channel networks are investigated in two-standard microfluidic systems: T-junctions are commonly used to split flow, mix, or converge flows, and serpentine channels are used to increase fluid resistance and residence time (Cho et al. 2003; Song and Ismagilov 2003).”
BackgroundElectrowetting Induced Droplet Generation in T-Junctions
Merdasi, A., & Moosavi, A. (2021) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.4049962 · Cited by 5
Takao, J., Endo, T., Hisamoto, H., & Sueyoshi, K. (2021) · Analytical Sciences · doi:10.2116/analsci.21p067 · Cited by 5
Zhang, D., Fu, L., Xu, G., & Zhang, Y. (2021) · Chemical Engineering Science · doi:10.1016/j.ces.2021.117037 · Cited by 5
Demand-Driven Multi-Target Sample Preparation on Resource-Constrained Digital Microfluidic Biochips
Poddar, S., Bhattacharjee, S., Fang, S., Ho, T.-Y., & Bhattacharya, B. B. (2021) · ACM Transactions on Design Automation of Electronic Systems · doi:10.1145/3474392 · Cited by 5
Tan, S. H. (2010) · doi:10.32657/10356/42313 · Cited by 5
Radivoyevitch, T. (2009) · Biology Direct · doi:10.1186/1745-6150-4-50 · Cited by 5
“Microfluidic chip technology [28-31] will eventually enable 5-dimensional RNR studies where [ATP] and Figure 11 The 13 single-edge spur models of Fig.”
MethodSingle Drop Electroanalysis and Interfacial Interactions: Sensitivity versus Limit of Detection†
Walgama, C. T., Matthew, G., & Krishnan, S. (2016) · Electroanalysis · doi:10.1002/elan.201600271 · Cited by 4
4.9 Myosin Motors: Kinetics of Myosin
Goldman, Y. E., & Ostap, E. M. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-374920-8.00411-2 · Cited by 7
A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Ben‐Yoav, H., Dykstra, P. H., Tschirhart, T., Bentley, W. E., & Reza Ghodssi, A. (2014) · Journal of Visualized Experiments · doi:10.3791/51797 · Cited by 4
Quantifying phenotypes in single cells using droplet microfluidics
Lyu, F., Blauch, L. R., & Tang, S. K. Y. (2018) · Methods in cell biology · doi:10.1016/bs.mcb.2018.09.006 · Cited by 4
Droplet-Based Microfluidics: Formation, Detection and Analytical Characterization
Hassan, S.-U. (2019) · Research & Development in Material Science · doi:10.31031/rdms.2019.11.000774 · Cited by 4
“In a study from Ismagilov’s group [62], chemical kinetics of ribonuclease A (RNase A) were measured in milliseconds within the droplet-based system.”
MethodKashani, M. N., Kriel, F. H., Binder, C., & Priest, C. (2020) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-2320-0 · Cited by 4
“2008), biology (Song and Ismagilov 2003; Dhouib et al.”
BackgroundMeissner, M., Seddon, A. M., & Royall, C. P. (2019) · Frontiers of nanoscience · doi:10.1016/b978-0-08-102302-0.00006-7 · Cited by 4
Hsieh, A. T.-H., Pan, P. J.-H., & Lee, A. P. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7721-z · Cited by 4
“” In addition, droplet microfluidic system offers rapid mixing of reagents in droplets through chaotic advection [36–39].”
BackgroundHollow hemisphere and microcapsules of nonionic copolymer
Manna, U., & Patil, S. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm01106a · Cited by 4
Measuring reaction rates on single particles in a microfluidic device
Caulum, M. M., & Henry, C. S. (2008) · Lab on a Chip · doi:10.1039/b714822d · Cited by 4
On-chip microfluidic generation of monodisperse bubbles for liquid interfacial tension measurement
Wang, C., Cao, J., Zhou, Y., & Xia, X. (2017) · Talanta · doi:10.1016/j.talanta.2017.08.084 · Cited by 4
Sandwiched droplet actuated by Marangoni force in a Hele-Shaw cell
Ng, V.-V., Sellier, M., & Nock, V. (2017) · Acta Mechanica · doi:10.1007/s00707-017-1986-1 · Cited by 4
Role of Interfacial Force on Multiphase Microflow—An Important Meso-Scientific Issue
Wang, K., Xu, J., Liu, G., & Luo, G. (2015) · Advances in chemical engineering · doi:10.1016/bs.ache.2015.10.003 · Cited by 4
Polymerization in Microfluidic Reactors
Kumacheva, E., Zhang, H., & Nie, Z. (2009) · Wiley eBooks · doi:10.1002/9780470431870.ch16 · Cited by 4
Kinetic aspects of analytical chemistry: progress and emerging trends
Crouch, S. R. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-3048-5 · Cited by 4
Günther, A., & Kreutzer, M. T. (2009) · Wiley eBooks · doi:10.1002/9783527631445.ch1 · Cited by 4
Milinović, J., Lunn, J., Attia, S., & Slavik, G. J. (2025) · Environments · doi:10.3390/environments12110434 · Cited by 4
Droplet-based fluorescence anisotropy insulin immunoassay
Adeoye, D. I., Masitas, R. A., Thornham, J., Meng, X., Steyer, D. J., & Roper, M. G. (2024) · Analytical Methods · doi:10.1039/d4ay01511h · Cited by 3
Microfluidics: Fabrication, Droplets, Bubbles and Nanofluids Synthesis
Zhang, Y., & Wang, L. (2011) · Advances in transport phenomena · doi:10.1007/978-3-642-19466-5_3 · Cited by 4
Mechanisms of mass transport during coalescence-induced microfluidic drop dilution
Wang, W. S., & Vanapalli, S. A. (2016) · Physical Review Fluids · doi:10.1103/physrevfluids.1.064001 · Cited by 3
Spectrophotometry in modular microfluidic architectures
Thompson, B., Bhargava, K. C., Czaja, A. T., Pan, B., Samuelsen, B. T., & Malmstadt, N. (2019) · Biomicrofluidics · doi:10.1063/1.5124303 · Cited by 3
In-line characterization and identification of micro-droplets on-chip
Weber, E., Puchberger-Enengl, D., Keplinger, F., & Vellekoop, M. J. (2013) · Optofluidics Microfluidics and Nanofluidics · doi:10.2478/optof-2013-0002 · Cited by 3
Intracavity microfluidic dye laser droplet absorption
Aubry, G., Méance, S., Couraud, L., Haghiri‐Gosnet, A., & Kou, Q. (2009) · Microelectronic Engineering · doi:10.1016/j.mee.2009.01.055 · Cited by 3
Zeitoun, R. I., Goudie, M. J., Zwier, J., Mahawilli, D., & Burns, M. A. (2011) · Lab on a Chip · doi:10.1039/c1lc20576e · Cited by 3
Microchip Technology in Metabolomics
Sikanen, T. M. (2013) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737272-00138 · Cited by 3
Cell Capture and Lysis on a Chip
Gac, S. L., & van den Berg, A. (2010) · Royal Society of Chemistry eBooks · doi:10.1039/9781849732284-00150 · Cited by 3
A random-access microarray for programmable droplet storage, retrieval and manipulation
Tseng, Y.-M., Wang, J.-J., & Su, Y.-C. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/4/045005 · Cited by 3
“In addition to the control over stoichiometry, which is achieved by the ability to form droplets with diverse volumes and compositions, the ability to parallelly manipulate a large number of droplets over certain periods of time could further realize the controllability desired for continuous tracking and multistep pr…”
BackgroundVitor, M. T., Sípoli, C. C., & de la Torre, L. G. (2015) · Research and reviews : journal of pharmacy and pharmaceutical sciences · Cited by 3
Formation of Droplets in Microfluidic Systems
Kumacheva, E., & Garstecki, P. (2011) · Wiley eBooks · doi:10.1002/9780470979228.ch5 · Cited by 5
Sun, M. Z., Maryu, G., Wang, S., Yang, Q., & Bailey, R. C. (2021) · Biomicrofluidics · doi:10.1063/5.0047924 · Cited by 2
Thermally Mediated Droplet Breakup Dynamics Within a Symmetric T-Junction
Nath, A. J., Deka, D. K., & Pati, S. (2025) · Journal of Fluids Engineering · doi:10.1115/1.4067961 · Cited by 2
Liu, C., Chen, X., Li, S., Zhu, H., Wei, Y., Wang, S., & Xie, L. (2025) · Chinese Journal of Chemistry · doi:10.1002/cjoc.70045 · Cited by 2
Droplet manipulation using a triboelectric gripper for lab-on-a-chip devices
Park, J., Kim, W., Kim, Y.-H., Chung, S. K., & Lee, K. Y. (2025) · Engineering Research Express · doi:10.1088/2631-8695/ae28b9 · Cited by 2
Energy-efficient scientific computing using chemical reservoirs
Johnson, C., Agostini, N. B., Cannon, W. R., & Tumeo, A. (2026) · npj Unconventional Computing · doi:10.1038/s44335-026-00053-9 · Cited by 2
Advances in microfluidic mixers for time-resolved structural biology with X-rays
Zielinski, K. A., & Pollack, L. (2025) · Biophysical Reviews · doi:10.1007/s12551-025-01321-x · Cited by 2
“Droplet mixers are well-established in microfluidics (Song and Ismagilov 2003; Bringer et al. 2004), but have only recently been employed for time-resolved structural biology.”
Grytsyk, N., Cianfarani, D., Crégut, O., Richert, L., Boudier, C., Humbert, N., Didier, P., Mély, Y., & Léonard, J. (2021) · Nucleic Acids Research · doi:10.1093/nar/gkab687 · Cited by 2
Droplet Microfluidics—A Tool for Biosensing and Bioengineering Applications
Banerjee, U., Iqbal, R., Hazra, S., Satpathi, N. S., & Sen, A. K. (2021) · Materials horizons · doi:10.1007/978-981-16-3645-5_7 · Cited by 2
Hammerschmid, D., Sýs, J., Bailey, A. G., Lane, S. I. R., Saito, M., Hornsey, T., Hanrahan, N., van Hateren, A., Broughton, H. B., Espada, A., et al. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c02766 · Cited by 2
Novel method of generating water-in-oil(W/O) droplets in a microchannel with grooved walls
Kim, J., Byun, D., & Hong, J. (2011) · Biomicrofluidics · doi:10.1063/1.3567102 · Cited by 2
Detection of Novel Enzyme Intermediates
Furdui, C. M., & Anderson, K. S. (2010) · Elsevier eBooks · doi:10.1016/b978-008045382-8.00158-1 · Cited by 2
Li, G., Huang, J., Zheng, Z., Cao, Q., Tian, Y., Huang, G., Li, L., & Ruotolo, B. T. (2021) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2021.116687 · Cited by 2
Walker, G. M. (2011) · Nature Chemistry · doi:10.1038/nchem.1060 · Cited by 2
Malmstadt, N., Jeon, T. J., Nash, M. A., Purnell, R. F., & Schmidt, J. J. (2006) · Advances in science and technology · doi:10.4028/3-908158-09-5.22 · Cited by 2
Metadata
- Authors
- Song, H., & Ismagilov, R. F.
- Affiliations
- University of Chicago (US)
- ORCID
- Ismagilov, Rustem F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-29
- Volume
- 125
- Issue
- 47
- Pages
- 14613-14619
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- PMC
- PMC1769313
- OpenAlex
- W2028894110
- Cited by
- 693
- References
- 45
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM08720, T32GM008720)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
- MeSH terms
- Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.