Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Experimental conditions in the continuous DIB device promote rapid transport equilibration between droplet compartments due to the inherent recirculating flow found in droplets.28,29”
From Chiral lipid bilayers are enantioselectively permeable (2021) · doi:10.1038/s41557-021-00708-z · cites this paper as [28]
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationRaines, R. T. (1998) · Chemical Reviews · doi:10.1021/cr960427h · Cited by 937
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Leach, C. L., Greenspan, J. S., Rubenstein, S. D., Shaffer, T. H., Wolfson, M. R., Jackson, J. C., DeLemos, R., & Fuhrman, B. P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609123351101 · Cited by 453
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citation
Research works printed but not linked: 19
- Shastry M. C. R., 1998, Biophys. J., 74, 2721
- Tice J. D., 2003, Langmuir, 19, 9133
- Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
- Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
- Ali J. A., 1997, Science, 275, 380
- Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
- Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
- Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
- Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
- Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
- Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
- Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
- Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
- Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
- Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
- Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
- Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
- Haykin S., 1994, Neural Networks
- Song H., 2003, Appl. Phys. Lett.
Cited by
Items 401–500 of 692
Thermolysis of 1,3-dioxin-4-ones: fast generation of kinetic data using in-line analysis under flow
Durand, T., Henry, C., Bolien, D., Harrowven, D. C., Bloodworth, S., Franck, X., & Whitby, R. J. (2015) · Reaction Chemistry & Engineering · doi:10.1039/c5re00007f · Cited by 21
Wang, X., Ma, X., An, L., Kong, X.-S., Xu, Z., & Wang, J.-H. (2013) · Science China Chemistry · doi:10.1007/s11426-012-4808-2 · Cited by 16
Chemical Mechanism Identification from Frequency Response to Small Temperature Modulation
Lemarchand, A., Berthoumieux, H., Jullien, L., & Gosse, C. (2012) · The Journal of Physical Chemistry A · doi:10.1021/jp305737e · Cited by 21
Lu, S., & Wang, K. (2019) · Reaction Chemistry & Engineering · doi:10.1039/c9re00046a · Cited by 22
Wang, S., Wannasarit, S., Figueiredo, P., Li, J., Correia, A., Xia, B., Wiwattanapatapee, R., Hirvonen, J. J., Liu, D., Li, W., et al. (2020) · Materials Horizons · doi:10.1039/d0mh00014k · Cited by 23
Microfluidic droplet trapping array as nanoliter reactors for gas–liquid chemical reaction
Zhang, Q., Zeng, S., Qin, J., & Lin, B. (2009) · Electrophoresis · doi:10.1002/elps.200900331 · Cited by 21
High-Performance Binary Protein Interaction Screening in a Microfluidic Format
Meier, M., Sit, R. V., Pan, W., & Quake, S. R. (2012) · Analytical Chemistry · doi:10.1021/ac302436y · Cited by 20
Batabyal, S., Rakshit, S., Kar, S., & Pal, S. K. (2012) · Review of Scientific Instruments · doi:10.1063/1.4704839 · Cited by 20
Modulating molecular and nanoparticle transport in flexible polydimethylsiloxane membranes
Jiao, K., Graham, C. L., Wolff, J., Iyer, R. G., & Kohli, P. (2012) · Journal of Membrane Science · doi:10.1016/j.memsci.2012.01.015 · Cited by 20
“[27] PDMS is the material of choice for use in microfluidic devices, microcontact printing etc.[28,29] If one were able to produce pores in PDMS, the high flexibility and mechanical strength of PDMS would accord adjustable pore sizes simply through mechanical stretching.”
BackgroundInvestigating Acrylic Acid Polymerization by Using a Droplet‐Based Millifluidics Approach
Lorber, N., Pavageau, B., & Mignard, E. (2010) · Macromolecular Symposia · doi:10.1002/masy.201051030 · Cited by 20
Nuñez, V., Upadhyayula, S., Millare, B., Larsen, J. M., Hadian, A., Shin, S., Vandrangi, P., Gupta, S., Xu, H. X., Lin, A., et al. (2013) · Analytical Chemistry · doi:10.1021/ac400200x · Cited by 20
Stagnation of a droplet on a conical substrate determined by the critical curvature ratio
Li, Y., Wu, H., & Wang, F. (2016) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/49/8/085304 · Cited by 20
Okano, T., Matsuura, T., Suzuki, H., & Yomo, T. (2013) · ACS Synthetic Biology · doi:10.1021/sb400087e · Cited by 20
Scalable production of double emulsion drops with thin shells
Vian, A., Reuse, B., & Amstad, E. (2018) · Lab on a Chip · doi:10.1039/c8lc00282g · Cited by 20
Zhao, S., Wang, W., Shao, T., Zhang, M., Jin, Y., & Cheng, Y. (2013) · Chemical Engineering Science · doi:10.1016/j.ces.2013.02.013 · Cited by 20
Neun, S., van Vliet, L., Hollfelder, F., & Gielen, F. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03164 · Cited by 20
Emerging platforms for high-throughput enzymatic bioassays
Shao, F., Lee, P., Li, H., Hsieh, K., & Wang, T. (2022) · Trends in biotechnology · doi:10.1016/j.tibtech.2022.06.006 · Cited by 20
Hafermann, L., & Köhler, J. M. (2015) · Journal of Nanoparticle Research · doi:10.1007/s11051-015-2914-8 · Cited by 19
“The very efficient mixing inside droplets is caused by flow-driven segment-internal convection (Malsch et al. 2008; Song and Ismagilov 2003).”
Tunable visual color filter using microfluidic grating
Li, Z. G., Yang, Y., Zhang, X., Liu, A. Q., Zhang, J. B., Cheng, L., & Li, Z. H. (2010) · Biomicrofluidics · doi:10.1063/1.3491469 · Cited by 19
Measuring enthalpy of fast exothermal reaction with micro‐reactor‐based capillary calorimeter
Wang, K., Lü, Y., Shao, H., & Luo, G. S. (2009) · AIChE Journal · doi:10.1002/aic.11792 · Cited by 19
Piezoelectric-driven droplet impact printing with an interchangeable microfluidic cartridge
Li, B., Fan, J., Li, J., Chu, J., & Pan, T. (2015) · Biomicrofluidics · doi:10.1063/1.4928298 · Cited by 19
Novel regimes of calcium carbonate dissolution in micron-scale confined spaces
Xu, J., & Balhoff, M. T. (2022) · Advances in Water Resources · doi:10.1016/j.advwatres.2022.104200 · Cited by 18
Tröpfchen‐Mikrofluidik für die Einzelzellanalyse
Joensson, H. N., & Svahn, H. A. (2012) · Angewandte Chemie · doi:10.1002/ange.201200460 · Cited by 18
High-sensitivity online detection for microfluidics via cavity ringdown spectroscopy
James, D., Oag, B., Rushworth, C. M., Lee, J. W. L., Davies, J., Cabral, J. T., & Vallance, C. (2012) · RSC Advances · doi:10.1039/c2ra20349a · Cited by 18
Kumacheva, E., & Garstecki, P. (2011) · Wiley eBooks · doi:10.1002/9780470979228.ch3 · Cited by 18
Chen, X., Hou, L., Zhang, Z., Lin, R., Lin, R., Yan, C. C., & Bao, F. (2022) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2022.130227 · Cited by 17
Chemistry with spatial control using particles and streams
Kalinin, Y. V., Murali, A., & Gracias, D. H. (2012) · RSC Advances · doi:10.1039/c2ra20337e · Cited by 19
Golynskiy, M. V., Haugner, J., Morelli, A., Morrone, D. J., & Seelig, B. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-293-3_6 · Cited by 23
Fundamentals of Microfluidics Devices
Addae‐Mensah, K. A., Wang, Z., Parsa, H., Chin, S. Y., Laksanasopin, T., & Sia, S. K. (2010) · Wiley eBooks · doi:10.1002/9780470622636.ch1 · Cited by 20
Electrocoalescence based serial dilution of microfluidic droplets
Bhattacharjee, B., & Vanapalli, S. A. (2014) · Biomicrofluidics · doi:10.1063/1.4891775 · Cited by 16
Dasmeh, P., Searles, D. J., Ajloo, D., Evans, D. J., & Williams, S. R. (2009) · The Journal of Chemical Physics · doi:10.1063/1.3261849 · Cited by 16
Wu, Y., Hu, B., Ma, X., Zhang, H., Li, W., Wang, Y., & Wang, S. (2021) · Lab on a Chip · doi:10.1039/d1lc00983d · Cited by 16
Li, C., Xu, J., & Ma, B. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-014-1497-5 · Cited by 16
“2013), microfluidic droplet systems enable the integration of various functional units and the accomplishment of a variety of complex biological and chemical assays such as enzyme kinetics (Bui et al. 2011; Song and Ismagilov 2003), cell culture and screening (Brouzes et al.”
BackgroundMechanics of liquid–liquid interfaces and mixing enhancement in microscale flows
Verguet, S., Duan, C., Liau, A., Berk, V., Cate, J. H. D., Majumdar, A., & Szeri, A. J. (2010) · Journal of Fluid Mechanics · doi:10.1017/s0022112009994113 · Cited by 16
“…asymmetric counter circulating flow patterns within the plug, as the plug progresses each half-cycle of the serpentine channel (Song et al. 2003; Song & Ismagilov 2003; Bringer et al. 2004), induces chaotic mixing (Ottino 1989; Ottino & Wiggins 2004; Wiggins & Ottino 2004; Sturman, Ottino &…”
BackgroundMicrofluidic Platforms for Lab-On-A-Chip Applications
Haeberle, S., Mark, D., von Stetten, F., & Zengerle, R. (2012) · Springer eBooks · doi:10.1007/978-3-642-18293-8_22 · Cited by 16
3D Ceramic Microfluidic Device Manufacturing
Natarajan, G., & Humenik, J. N. (2006) · Journal of Physics Conference Series · doi:10.1088/1742-6596/34/1/088 · Cited by 16
Droplet collision mixing diagnostics using single fluorophore LIF
Carroll, B., & HIDROVO, C. H. (2012) · Experiments in Fluids · doi:10.1007/s00348-012-1361-x · Cited by 16
“However, the microsecond mixing times that have been achieved for continuous flow systems (Knight et al. 1998; Hertzog et al. 2004, 2006) are two orders of magnitude smaller than the state of the art for droplet-based systems (Song et al. 2003, 2006; Song and Ismagilov 2003).”
BackgroundOperation of microfluidic liquid slug formation and slug design for kinetics measurement
Matsuyama, K., Tanthapanichakoon, W., Aoki, N., & Mae, K. (2007) · Chemical Engineering Science · doi:10.1016/j.ces.2007.02.004 · Cited by 16
Space- and time-resolved spectrophotometry in microsystems
Damean, N. A., Sia, S. K., Linder, V., Narovlyansky, M., & Whitesides, G. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504712102 · Cited by 16
Chung, C. H. Y., Lau, C. M. L., Sin, D. T., Chung, J. T., Zhang, Y., Chau, Y., & Yao, S. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.1c00509 · Cited by 15
Sarkar, K., & Singh, R. K. (2013) · Physics of Fluids · doi:10.1063/1.4805082 · Cited by 15
Emerging optofluidic technologies for biodiagnostic applications
Wu, J., Dai, B., Li, Z., Pan, T., Zhang, D., & Lin, F. (2021) · View · doi:10.1002/viw.20200035 · Cited by 15
Baret, J., Taly, V., Ryckelynck, M., Merten, C. A., & Griffiths, A. D. (2009) · médecine/sciences · doi:10.1051/medsci/2009256-7627 · Cited by 22
Direct current dielectrophoretic manipulation of the ionic liquid droplets in water
Zhao, K., & Li, D. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.05.020 · Cited by 16
Gerdts, C. J., Tereshko, V. A., Yadav, M. K., Dementieva, I., Collart, F., Joachimiak, A., Stevens, R. C., Kühn, P., Kossiakoff, A. A., & Ismagilov, R. F. (2006) · Angewandte Chemie · doi:10.1002/ange.200602946 · Cited by 15
Self-citationHeleg-Shabtai, V., Gratziany, N., & Liron, Z. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.087 · Cited by 15
Single echo acquisition MRI using RF encoding
Wright, S. M., & McDougall, M. P. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1399 · Cited by 15
Tanthapanichakoon, W., Matsuyama, K., Aoki, N., & Mae, K. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2006.08.049 · Cited by 15
Optimization of Multi-Target Sample Preparation On-Demand With Digital Microfluidic Biochips
Poddar, S., Bhattacharjee, S., Nandy, S. C., Chakrabarty, K., & Bhattacharya, B. B. (2018) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/tcad.2018.2808234 · Cited by 14
“of a sample) is also required in the study of molecular kinematics [45], which are needed for understanding protein (RNA) folding, enzymatic and chemical”
Scaling up the Throughput of Synthesis and Extraction in Droplet Microfluidic Reactors
Korczyk, P. M., Dolega, M. E., Jakieła, S., Jankowski, P., Makulska, S., & Garstecki, P. (2015) · Journal of Flow Chemistry · doi:10.1556/jfc-d-14-00038 · Cited by 14
Zhang, Y., Li, K., Zhao, Y., Shi, W., Iyer, H. T., Kim, S., Brenden, C. K., Sweedler, J. V., & Vlasov, Y. A. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02323 · Cited by 13
Soft matter principles of microfluidics
Colin, A., Squires, T. M., & Bocquet, L. (2012) · Soft Matter · doi:10.1039/c2sm90116a · Cited by 13
Design of a flow-controlled asymmetric droplet splitter using computational fluid dynamics
Verbruggen, B., Tóth, T., Atalay, Y. T., Ceyssens, F., Verboven, P., Puers, R., Nicolaï, B. M., & Lammertyn, J. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1139-3 · Cited by 13
Liu, J., Lin, J., & Knopp, D. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/9/095014 · Cited by 13
“Nanoliter droplets formed during this process are widely used as microreactors for many chemical and biological applications [7], such as protein crystallizations [8, 9], nanoparticle synthesis [10–12], polymerization reactions [13–17] and kinetic measurements [18, 19].”
MethodMaillot, S., Carvalho, A., Vola, J.-P., Boudier, C., Mély, Y., Haacke, S., & Léonard, J. (2014) · Lab on a Chip · doi:10.1039/c3lc51283e · Cited by 13
Cao, X. S., & Chen, Y. (2023) · Science China Technological Sciences · doi:10.1007/s11431-022-2284-9 · Cited by 14
Negou, J. T., Hu, J., Li, X., & Easley, C. J. (2018) · Analytical Methods · doi:10.1039/c8ay00947c · Cited by 13
A review on the development and application of microfluidic concentration gradient generators
Wu, Z., Yang, H., Xu, H., Dai, W., Xu, L., Du, H., & Zhang, D. (2024) · Physics of Fluids · doi:10.1063/5.0219368 · Cited by 12
Jia, N., Daignault-Bouchard, A., Deng, T., Mayerhöfer, T. G., Bégin‐Drolet, A., & Greener, J. (2023) · Lab on a Chip · doi:10.1039/d3lc00388d · Cited by 13
Droplet Microfluidic Technique for the Study of Fermentation
Churski, K., Ruszczak, A., Jakieła, S., & Garstecki, P. (2015) · Micromachines · doi:10.3390/mi6101435 · Cited by 12
Cui, M., Feng, H., Guo, D., Wang, D., & Zheng, B. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.009 · Cited by 12
Yang, H., Qiao, X., Bhattacharyya, M. K., & Dong, L. (2011) · Biomicrofluidics · doi:10.1063/1.3651620 · Cited by 12
Rapid serial diluting biomicrofluidic provides EC50 in minutes
Ortiz, R., Chen, J. L., Stuckey, D. C., & Steele, T. W. J. (2019) · Micro and Nano Engineering · doi:10.1016/j.mne.2019.02.002 · Cited by 12
Microfluidic synthesis of quantum dots: Design, mechanism, properties and applications
Zhang, S., Li, J., Liu, J., Abolhasani, M., & Hou, L. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.173612 · Cited by 11
Nuhiji, E., Amar, F. G., Wang, H., Byrne, N., Nguyen, T., & Lin, T. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm10531k · Cited by 11
The microfluidic laboratory at Synchrotron SOLEIL
Chaussavoine, I., Beauvois, A., Mateo, T., Vasireddi, R., Douri, N., Priam, J., Liatimi, Y., Lefrançois, S., Tabuteau, H., Davranche, M., et al. (2019) · Journal of Synchrotron Radiation · doi:10.1107/s1600577519015042 · Cited by 11
“…of microfluidic systems to explore physical phenomena that can only be accessed under specific physical conditions: interfacial physics (Hemmerle et al., 2016), emulsions (Zarzar et al., 2015) and droplets (Joanicot & Ajdari, 2005) formation or (bio)chemical kinetics (Song & Ismagilov, 2003).”
BackgroundSun, W. Y., Liu, J., Hao, Q., Lu, K., Wu, Z., & Chen, H. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb01968f · Cited by 11
Monitoring microfluidic interfacial flows using impedance spectroscopy
Mavrogiannis, N., Fu, X., Desmond, M., Robert, M., & Gagnon, Z. R. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.07.123 · Cited by 11
Stimuli-Responsive Nanomaterials for Drug Delivery
López‐Saucedo, F., Flores‐Rojas, G. G., Melendez‐Ortiz, H. I., Morfín-Gutiérrez, A., Luna-Straffon, M. A., & Bucio, E. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-814031-4.00014-3 · Cited by 13
Takahashi, K., Mawatari, K., Sugii, Y., Hibara, A., & Kitamori, T. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0622-3 · Cited by 11
“In the previous articles ( Song and Ismagilov 2003, 2003b ), rapid (* 2 ms) mixing has already been achieved by inducing chaotic flow inside droplets moving through the winding part of the channel.”
BackgroundGeneration of sub-femtoliter droplet by T-junction splitting on microfluidic chips
Yang, Y., Feng, X., Xu, N., Pang, D., & Zhang, Z. (2013) · Applied Physics Letters · doi:10.1063/1.4798510 · Cited by 11
Lee, H.-J., Yoon, T.-H., Park, J.-H., Perumal, J., & Kim, D. (2007) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2007.06.002 · Cited by 11
Hou, Y., Xing, Y., Feng, S.-L., Gao, C., Zhou, H., & Zheng, Y. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201901183 · Cited by 9
Hejazian, M., Balaur, E., & Abbey, B. (2021) · Applied Sciences · doi:10.3390/app11083404 · Cited by 11
“Another study of chaotic mixing in serpentine channels was carried out by Song and Ismagilov [29], who examined the millisecond kinetics of an enzymatic reaction by measuring the fluorescence intensities using nanolitre droplets.”
MethodOrganic Chemistry in Microreactors
Fukuyama, T., Rahman, M. T., Ryu, I., Baxendale, I. R., Hayward, J. J., Lanners, S., Ley, S. V., Smith, C. D., Ahmed‐Omer, B., Wirth, T., et al. (2008) · Wiley eBooks · doi:10.1002/9783527622856.ch4 · Cited by 11
Chan, E. M. (2025) · Nano Letters · doi:10.1021/acs.nanolett.5c05228 · Cited by 13
Kashid, M. N., Detraz, O., Moya, M. S., Yuranov, I. A., Prechtl, P., Membrez, J., Renken, A., & Kiwi‐Minsker, L. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.10.019 · Cited by 10
Luo, R., Dong, J., Li, X., & Luo, Y. (2020) · Colloid & Polymer Science · doi:10.1007/s00396-020-04631-6 · Cited by 10
Pre-programmed microdroplet generator to control wide-ranging chemical concentrations
Ahamed, M. A., Kim, G., Li, Z., & Kim, S. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340587 · Cited by 10
Phenomenology and kinetics of sessile droplet evaporation on convex contours
Paul, A., Dash, R. K., & Dhar, P. (2023) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2023.108194 · Cited by 10
Programmable microfluidic platform for spatiotemporal control over nanoliter droplets
Thakur, R., Zhang, Y., Amin, A., & Wereley, S. T. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-014-1507-7 · Cited by 11
“A few devices have demonstrated methodologies for studying enzyme-inhibition reaction kinetics (Sjostrom et al. 2013; Song and Ismagilov 2003).”
BackgroundA New Concentration Jump Strategy Reveals the Lifetime of i‑Motif at Physiological pH without Force
Jonchhe, S., Shrestha, P., Ascencio, K., & Mao, H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04661 · Cited by 10
Efficient Generation of Dilution Gradients With Digital Microfluidic Biochips
Bhattacharjee, S., Banerjee, A., Ho, T.-Y., Chakrabarty, K., & Bhattacharya, B. B. (2018) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/tcad.2018.2834413 · Cited by 10
“Additionally, molecular-concentration gradients are required for in-vitro toxicity analysis [19], [20], studies in enzymatic kinetics [21], and protein-expressions [22].”
BackgroundHydrodynamic focusing controlled microfluidic laser emission
Lei, L., Zhou, Y., & Chen, Y. (2009) · Microelectronic Engineering · doi:10.1016/j.mee.2009.01.016 · Cited by 10
Integration of a Droplet-Based Microfluidic System and Silicon Nanoribbon FET Sensor
Afrasiabi, R., Söderberg, L., Joensson, H. N., Björk, P., Svahn, H. A., & Linnros, J. (2016) · Micromachines · doi:10.3390/mi7080134 · Cited by 10
“Droplet microfluidics has proven advantages in the miniaturization of reactions by compartmentalization to achieve higher reaction rates and resolution [2], as well as in applications such as cell screening [3].”
BackgroundFundamental Concepts and Physics in Microfluidics
Song, Y., Zhao, X., Tian, Q., & Liang, H. (2018) · Wiley eBooks · doi:10.1002/9783527800643.ch2 · Cited by 11
Damir, S. S., Probst, J., deMello, A. J., & Stavrakis, S. (2025) · Chemistry - Methods · doi:10.1002/cmtd.202500069 · Cited by 12
Chen, W., Vashistha, P., Yen, A. T., Joshi, N. Y., Kapoor, Y., & Hartman, R. L. (2018) · Energy & Fuels · doi:10.1021/acs.energyfuels.8b02854 · Cited by 9
Stroock, A. D. (2008) · Elsevier eBooks · doi:10.1016/b978-044453125-4.50019-x · Cited by 11
Method for Passive Droplet Sorting after Photo-Tagging
Dobson, C. D., Zielke, C., Pan, C. W., Feit, C., & Abbyad, P. (2020) · Micromachines · doi:10.3390/mi11110964 · Cited by 10
“Kinetic measurements in droplets, such as fast kinetics [23] and Michaelis-Menton kinetic measurements [24], are also difficult to integrate with current active droplet sorting technology.”
MethodFocusing of Particles in a Microchannel with Laser Engraved Groove Arrays
Zhang, T., Shen, Y., Kiya, R., Anggraini, D., Tang, T., Uno, H., Okano, K., Tanaka, Y., Hosokawa, Y., Li, M., et al. (2021) · Biosensors · doi:10.3390/bios11080263 · Cited by 9
“Features such as small size [3], low reagent consumption [4], fast analysis [5], and low cost [6] make it suitable for various applications in different fields, such as drug delivery [7], point-of-care diagnosis [8], single cell virology [9], cell separation [10] and polymer synthesis [11].”
BackgroundA fast, non-iterative ray-intersection approach for three-dimensional microscale particle tracking
Liu, H., & Chamorro, L. P. (2022) · Lab on a Chip · doi:10.1039/d1lc01042e · Cited by 9
Multi-helical micro-channels for rapid generation of drops of water in oil
Ganneboyina, S. R., & Ghatak, A. K. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1178-9 · Cited by 9
“In essence, we have here a helical micro-channel, which renders the flow field inherently three-dimensional because of combined effect of the primary axial flow and the secondary circumferential flow (Song and Ismagilov 2003; Song et al. 2006; Srinivasan et al. 2004).”
MethodMa, H., Li, Y., Cao, F., Gao, Y., Gong, J., & Deng, Y. (2010) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.24140 · Cited by 9
Modeling of droplet traffic in interconnected microfluidic ladder devices
Song, K., Zhang, L., & Hu, G. (2012) · Electrophoresis · doi:10.1002/elps.201100320 · Cited by 9
Path selection rules for droplet trains in single-lane microfluidic networks
Amon, A., Schmit, A., Salkin, L., Courbin, L., & Panizza, P. (2013) · Physical Review E · doi:10.1103/physreve.88.013012 · Cited by 9
Hallmark, B., Parmar, C., Walker, D., Hornung, C., Mackley, M. R., & Davidson, J. F. (2009) · Chemical Engineering Science · doi:10.1016/j.ces.2009.04.027 · Cited by 9
“…phase (Burns and Ramshaw, 2001; Song and Ismagilov, 2003; Song et al., 2003), coupled with the nanolitre volume of fluid required for droplet formation, allow for highly accurate measurement of reaction kinetics in chemical and biochemical systems (Song and Ismagilov, 2003; Song et al., 2003).”
BackgroundMethodInfluentialHeterogeneous Multiphase Reactions
Kashid, M. N., Agar, D. W., Renken, A., & Kiwi‐Minsker, L. (2009) · Wiley eBooks · doi:10.1002/9783527631445.ch15 · Cited by 9
Belder, D. (2005) · Angewandte Chemie · doi:10.1002/ange.200500620 · Cited by 9
pH Oscillator Stretched in Space but Frozen in Time
Hermans, T. M., Stewart, P. S., & Grzybowski, B. A. (2015) · The Journal of Physical Chemistry Letters · doi:10.1021/jz502711c · Cited by 8
Metadata
- Authors
- Song, H., & Ismagilov, R. F.
- Affiliations
- University of Chicago (US)
- ORCID
- Ismagilov, Rustem F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-29
- Volume
- 125
- Issue
- 47
- Pages
- 14613-14619
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- PMC
- PMC1769313
- OpenAlex
- W2028894110
- Cited by
- 693
- References
- 45
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM08720, T32GM008720)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
- MeSH terms
- Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.