Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Experimental conditions in the continuous DIB device promote rapid transport equilibration between droplet compartments due to the inherent recirculating flow found in droplets.28,29”
From Chiral lipid bilayers are enantioselectively permeable (2021) · doi:10.1038/s41557-021-00708-z · cites this paper as [28]
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationRaines, R. T. (1998) · Chemical Reviews · doi:10.1021/cr960427h · Cited by 937
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Leach, C. L., Greenspan, J. S., Rubenstein, S. D., Shaffer, T. H., Wolfson, M. R., Jackson, J. C., DeLemos, R., & Fuhrman, B. P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609123351101 · Cited by 453
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citation
Research works printed but not linked: 19
- Shastry M. C. R., 1998, Biophys. J., 74, 2721
- Tice J. D., 2003, Langmuir, 19, 9133
- Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
- Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
- Ali J. A., 1997, Science, 275, 380
- Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
- Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
- Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
- Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
- Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
- Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
- Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
- Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
- Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
- Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
- Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
- Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
- Haykin S., 1994, Neural Networks
- Song H., 2003, Appl. Phys. Lett.
Cited by
Items 601–692 of 692
Kim, D.-Y., Jin, S. H., & Lee, C. (2016) · Journal of Dispersion Science and Technology · doi:10.1080/01932691.2016.1154862 · Cited by 2
High-precision microfluidic pressure control through modulation of dual fluidic resistances
Toth, M. J., Kawahara, T., & Kim, Y. (2017) · International Journal of Dynamics and Control · doi:10.1007/s40435-017-0378-7 · Cited by 2
Mercadal, P. A., Motrich, R. D., & Coronado, E. A. (2019) · Scientific Reports · doi:10.1038/s41598-019-49583-2 · Cited by 2
Effects of Microfluidics on Preparative Chemistry Processes
Kashid, M. N., Renken, A., & Kiwi‐Minsker, L. (2013) · Wiley eBooks · doi:10.1002/9783527652891.ch02 · Cited by 2
Stimulus‐Responsive Polymers at Nanointerfaces
Vasani, R. B., Cole, M. A., Ellis, A. V., & Voelcker, N. H. (2011) · Wiley eBooks · doi:10.1002/9783527610419.ntls0247 · Cited by 2
Synthesis of Nanomaterials Using Continuous‐Flow Microreactors
Chang, C. (2013) · Wiley eBooks · doi:10.1002/9783527652891.ch07 · Cited by 2
Microfluidic Relief for Transport Limitations
Stroock, A. D., Wheeler, T. D., & Kirtland, J. D. (2005) · BioTechniques · doi:10.2144/05392te01 · Cited by 2
A Study on the Flow Behavior of Microbubbles in Capillary Tubes
Shams, M. M. (2014) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/25048 · Cited by 2
Mixing time of homogeneous/heterogeneous solutions in a micro-mixer with free impinging jets
Endo, T., & Itakura, R. (2023) · Bulletin of the Chemical Society of Japan · doi:10.1093/bulcsj/uoad021 · Cited by 1
Moniruzzaman, M., Bezerra, A. B., Mohibullah, M., Judd, R. L., Granneman, J. G., & Easley, C. J. (2024) · Lab on a Chip · doi:10.1039/d4lc00664j · Cited by 1
Iron‐Catalyzed Cross‐Coupling Reactions of Alkyl Grignard Reagents with Alkenyl Carbonate
Qin, H., Yang, X., Bonku, E. M., Zhu, F., Abduahadi, S., Yang, P., Shen, J., & Aisa, H. A. (2024) · Advanced Synthesis & Catalysis · doi:10.1002/adsc.202400979 · Cited by 1
Enhanced fluid mixing in a T-shaped microchannel using oscillatory pressure modulation
Sas, S. E., Roshchin, D. E., & Патлажан, С. А. (2025) · International Journal of Heat and Fluid Flow · doi:10.1016/j.ijheatfluidflow.2025.110102 · Cited by 1
Wang, M. (2011) · Deep Blue (University of Michigan) · Cited by 1
Écoulement de gouttes dans des microcanaux : simulations numériques et expériences
Colin, A., Cristobal, G., Galusinski, C., Khadra, K., & Vigneaux, P. (2007) · DSpace (Centre National De La Recherche Scientifique) · Cited by 1
Braddick, L., Garland, P., Praeger, M. F., Butement, J. T., Friedrich, D., Morgan, D. J., & Melvin, T. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.02.020 · Cited by 1
“Lab-on-a-chip formats are advantageous with respect to reduced sample consumption [1] and processing time [2] as well as sometimes providing improved sensitivity [3].”
BackgroundAutomated Droplet Microfluidic Chips for Biochemical Assays
Kamiński, T. S., Churski, K., & Garstecki, P. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3265-4_5 · Cited by 1
Micro and nanotechnological tools for study of RNA
Yoshizawa, S. (2012) · Biochimie · doi:10.1016/j.biochi.2012.03.018 · Cited by 1
Droplet generation and mixing in confined gaseous microflows
Carroll, B. (2012) · Texas ScholarWorks (Texas Digital Library) · Cited by 1
Microfluidic Micro/Nano Droplets
Kamalakshakurup, G., Vallejo, D., & Lee, A. P. (2017) · Springer handbooks · doi:10.1007/978-3-662-54357-3_17 · Cited by 1
Transport of Droplets in Microfluidic Systems
Garstecki, P. (2010) · NATO science for peace and security series. A, Chemistry and biology · doi:10.1007/978-90-481-9029-4_10 · Cited by 1
“droplet systems – via the simple correspondance between the time and position of the droplet flowing in a microchannel – offer for convenient temporal resolution and for control of the kinetic conditions of reactions [ 28 ].”
BackgroundTissue Engineering and Analysis in Droplet Microfluidics
Shi, N., Moniruzzaman, M., & Easley, C. J. (2020) · Royal Society of Chemistry eBooks · doi:10.1039/9781839162855-00223 · Cited by 4
Microfluidics technology: past, present, and future prospects for biomarker diagnostics
Bahrani, S., Ghalamfarsa, F., Nekoi, S., Ghaedi, M., Hashemi, S. A., & Mousavi, S. M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822859-3.00018-3 · Cited by 1
Real-Time Tracking of Individual Droplets in Multiphase Microfluidics
Ibarlucea, B., Schütt, J., Baraban, L., Makarov, D., Medina‐Sánchez, M., & Cuniberti, G. (2022) · Biomedical engineering · doi:10.5772/intechopen.106796 · Cited by 1
Real-Time Measurement Technique for Slug Flow Characterisation
Zadeh, S. S. S., Egan, V. M., & Walsh, P. A. (2022) · Journal of Fluid Flow Heat and Mass Transfer · doi:10.11159/jffhmt.2022.023 · Cited by 1
Capillary Flow-MRI: Quantifying Micron-Scale Cooperativity in Complex Dispersions
Milc, K. W., Oerther, T., Dijksman, J. A., van Duynhoven, J., & Terenzi, C. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c01108 · Cited by 1
Javed, A., & Jakkam, L. K. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15416-4.00004-9 · Cited by 3
Active Control of Droplet Formation Process in Microfluidics
Nguyen, N., & Tan, S. H. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3265-4_3 · Cited by 1
Manipulating Fluids: Advances in Micro-Fluidics, Opto-Fluidics and Fluidic Self-Assembly
Vyawahare, S. (2006) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/04xy-c430 · Cited by 1
Microfluidic Devices for Studying Kinetics
Wilson, D. J. (2010) · Wiley eBooks · doi:10.1002/9780470622636.ch3 · Cited by 1
Potential of Microfluidics and Single Cell Analysis in Metabolomics (Micrometabolomics)
Mensack, M. M., Holcomb, R. E., & Henry, C. S. (2013) · Wiley eBooks · doi:10.1002/9783527655861.ch10 · Cited by 1
Kim, J., Byun, D., Hong, J., & deMello, A. J. (2009) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2009.4805434 · Cited by 1
“Highly reproducible monodisperse droplets have been prepared using a variety of methods, including geometry-dominated break-up [5,6], cross-flow rupturing through microchannel arrays [7], capillary instability-mediated drop formation (in a flow focusing configuration) [8] and pressure-drop induced break-up (at a micro…”
MethodYang, J. (2014) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 1
Laboratoire Physico-chimie Curie
Vi, P., & Chabert, M. (2009) · Cited by 1
Gardeniers, H. J. G. E. (2009) · Wiley eBooks · doi:10.1002/9780470431870.ch20 · Cited by 1
Thermodynamics and Kinetics of Advanced Separations Systems ? FY 2010 Summary Report
Martin, L. R., & Zalupski, P. R. (2010) · doi:10.2172/1009159 · Cited by 1
Polymerization in Microfluidic Reactors
Greener, J., & Kumacheva, E. (2013) · Wiley eBooks · doi:10.1002/9783527652891.ch08 · Cited by 1
MICROFLUIDIQUE DE GOUTTES POUR LES ANALYSES BIOLOGIQUES
Chabert, M. (2007) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 1
Microfluidic emulsion characterization for the development of armored droplet arrays
Maltas, S. K. (2006) · DSpace@MIT (Massachusetts Institute of Technology)
Droplet-based Microfluidic Systems Coupled to Mass Spectrometry for Enzyme Kinetics
Nichols, K. P. (2009) · University of Twente Research Information · doi:10.3990/1.9789090239316
Brisure de gouttes dans une jonction en T à faible nombre \n capillaire
Jullien, M.-C., Ching, M.-J. T. M., Cohen, C., Ménétrier, L., & Tabeling, P. (2009) · DSpace (Centre National De La Recherche Scientifique)
Precision Optical Measurements of DNA Structure and Synthesis
Ma, Z. (2008) · PhDT · doi:10.7907/vknw-bs41
Towards biological experimentation in microfludic microdroplets
Courtois, F., Huebner, A., Stein, V., Olguín, L. F., & Hollfelder, F. (2009) · La Houille Blanche · doi:10.1051/lhb/2009065 · Cited by 1
“droplets where either the average fluorescence of a droplet stream was measured [10] or the fluorescence of one statio-”
BackgroundMethodInfluentialMicro-mixing of microbeads utilizing vortex generation near a micro-nano interface
Lee, S., & Kim, D. (2011) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2011.6181366
Microfluidics with near infrared fluid handling
Kotz, K. T., Gu, Y., & Paris, G. W. (2005) · Conference on Lasers and Electro-Optics · doi:10.1109/cleo.2005.202401
Research on mixing mechanism of micromixer based on segmented gas-liquid flow
Wang, Y., Wang, R., & Wang, L.-N. (2009) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2009.5068727
“literature data for passive micromixers consisting of patterned or three-dimensional microchannel networks, and with the droplet-based technique of Song et al.[3,5, 9 ,12].”
BackgroundMethodMiniaturizing the miniature: Liquid droplets as miniscule reactors
Patnaik, P. R. (2013) · Journal Of Biochemical Technology
Li, C., Xu, J., & Ma, B. (2014) · The Analyst · doi:10.1039/c4an01852d
Live Single Cell Imaging and Analysis Using Microfluidic Devices
Khorshidi, M. A. (2013) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Criblage à très haut débit en biologie
Baret, J., Taly, V., Ryckelynck, M., Merten, C. A., & Griffiths, A. D. (2009)
Microfluidics for Time‐resolved Mass Spectrometry
(2016) · Wiley eBooks · doi:10.1002/9781118887332.ch7
ON-DEMAND SERIAL DILUTION USING QUANTIZED NANO/PICOLITER-SCALE DROPLETS
Jambovane, S. R., & Kelly, R. (2014)
Preparation of micro water droplets in micro-channel by digital jetting
Zhou, Z., Xu, G., Liu, C., & Zhang, J. (2016) · doi:10.2991/icseee-15.2016.154
“the protein crystallization, to synthesize the nanoliter-size droplets or reagents in micro-channels [2, 3].”
BackgroundDynamic Micro PIV Measurement of Transient Flow in Microfluidic Device
Shinohara, K., Sugii, Y., Aota, A., Hibara, A., Kitamori, T., & Okamoto, K. (2004) · Journal of the Visualization Society of Japan · doi:10.3154/jvs.24.supplement1_39
Shishido, M., Abe, H., & Matsuda, K. (2011) · KAGAKU KOGAKU RONBUNSHU · doi:10.1252/kakoronbunshu.37.96
DNA Analysis in Microfluidic Devices and their Application to Single Cell Analysis
Marcy, Y., & Bras, A. L. (2010) · Royal Society of Chemistry eBooks · doi:10.1039/9781849732284-00185
Microfluidics: Basic Concepts and Microchip Fabrication
Vollrath, C., & Dittrich, P. S. (2010) · Royal Society of Chemistry eBooks · doi:10.1039/9781849732284-00111 · Cited by 1
Applications of Time‐resolved Mass Spectrometry in Biochemical Analysis
Urban, P. L., Chen, Y., & Wang, Y. (2016) · Wiley eBooks · doi:10.1002/9781118887332.ch13
Droplet microfluidics for single cell and nucleic acid analysis
Rajeswari, P. K. P., & Kumar, P. (2016)
Development of a two-phase microfluidic platform for drug screening
Clausell-Tormos, J. (2009) · OpenGrey (Institut de l'Information Scientifique et Technique)
Simple Chip-based Interfaces for On-line Nanospray Mass Spectrometry
Brivio, M., Verboom, W., & Reinhoudt, D. N. (2008) · Royal Society of Chemistry eBooks · doi:10.1039/bk9780854041299-00201
Self-propulsion and mixing of microdroplets through surface tension gradient
Ng, V.-V. (2017) · UC Research Repository (University of Canterbury) · doi:10.26021/2791
OPTICAL IMAGE-BASED DYNAMIC MANIPULATION OF AQUEOUS DROPLETS IMMERSED IN OIL MEDIUM
Park, S.-Y., Wu, T., Wei, K., Kalim, S., Callahan, C. L., Teitell, M. A., & Chiou, E. P. Y. (2008) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2008.72
Record the Single Cell Signal Pathway
Chiang, Y.-Y. (2020) · Springer eBooks · doi:10.1007/978-981-10-4857-9_37-1
Automated, computational approaches to kinetic model and parameter determination
Taylor, C. J. (2020) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Outils microfluidiques pour l'ingénierie d'enzymes d'intérêt thérapeutique
Vigne, A. (2018) · theses.fr (ABES) · doi:10.70675/5b16c5b5z3df3z49c4zb0eeze6a68df3de41
Harnessing Acoustic Streaming for Bioanalysis in Microfluidics
Li, X. (2021) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.8253
Record the Single Cell Signal Pathway
Chiang, Y.-Y. (2021) · Springer eBooks · doi:10.1007/978-981-10-8953-4_37
Zhang, X. (2018) · MDPI eBooks · doi:10.3390/books978-3-03897-096-5
Lii, J., Hsu, W., Lee, S. P., & Sia, S. K. (2006) · Wiley eBooks · doi:10.1002/0471238961.micrsia.a01
Overview of Micro Reaction Engineering
Kashid, M. N., Renken, A., & Kiwi‐Minsker, L. (2014) · Wiley eBooks · doi:10.1002/9783527685226.ch1
Hu, J., Li, X., Judd, R. L., & Easley, C. J. (2019) · ChemRxiv · doi:10.26434/chemrxiv.9927065
Beck‐Sickinger, A. G., Braunschweig, H., Holthausen, M. C., Schroeder, S. L. M., Spatz, J. P., Terfort, A., Wille, U., Beck‐Sickinger, A. G., Hammar, F., Spatz, J. P., et al. (2004) · Nachrichten aus der Chemie · doi:10.1002/nadc.20040520205
A Pipette for High-Resolution Sampling and Delivery of pL Bio-Samples
Han, Z., Gong, P., Su, H., Gao, Z., Feng, S., & Zhao, J. (2025) · Micromachines · doi:10.3390/mi16060630
Maillot, S. (2013) · theses.fr (ABES) · doi:10.70675/1d2c55b5zc463z4d61zb0b4z260b5c5411e2
“Des gouttelettes de quelques 100 picolitres peuvent être créées et dans lesquelles des réactifs sont mélangés en un temps pouvant être inférieur à la milliseconde [34, 35, 36].”
Real-time optical spectroscopy for in situ single-droplet analysis
Pandillapally, R., Pillanagrovi, J., Dutta‐Gupta, S., & Duraiswamy, S. (2026) · Nanoscale Advances · doi:10.1039/d5na01087j
Balanced Cascade: Free-Flowing Microfluidic Lab-On-Chip for Generating Serial Dilutions
Banerjee, T., Poddar, S., & Bhattacharya, B. B. (2026) · International Conference on VLSI Design · doi:10.1109/vlsid68508.2026.00041
Lorber, N. (2011) · theses.fr (ABES) · doi:10.70675/0b2d1530z7186z4b9fz98aazd0a3443881b6 · Cited by 3
Roberto Company (2014) · theses.fr (ABES) · doi:10.70675/b2f8d8a6z4307z48f4zb46az8a6a86fa6ebc
Screening and improving light-up RNA aptamer properties using droplet-based microfluidics
Autour, A. (2018) · theses.fr (ABES) · doi:10.70675/575c94f4ze9f5z4420z8a10z5a3d243d0c1f
Élaboration et caractérisation d’émulsions millimétriques obtenues par microfluidique
Pujol, A. (2015) · theses.fr (ABES) · doi:10.70675/56439b2az75eaz4ed4z91b2zc44fdbf878bd
Combinatorial antibiotic screening using droplet microfluidics
Perima, A. (2017) · theses.fr (ABES) · doi:10.70675/229a00dfz3606z4f5fzab24zb27f9789499a
Gao, Z., Zhang, Y., Tan, A., Chen, P., Liu, S., Qiu, M., Wang, Z. B., Ma, Y., Qian, G., Schuurmans, J. H. A., et al. (2026) · Communications Chemistry · doi:10.1038/s42004-026-02026-2
Mixing Inside Coalesced Droplets after Head-On Collisions in Microchannels
Lian, H., Zhou, T., Zhu, D., & Liu, D. (2026) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.6c00366
Urashima, S., Murai, Y., & Kusaka, R. (2026) · The Analyst · doi:10.1039/d6an00653a
Llobet, M., & Felpin, F. (2026) · Reaction Chemistry & Engineering · doi:10.1039/d6re00342g
EDTA-based self-assembly of gold nanorods in droplet microfluidics
Rama, P., Tripathi, D., Gupta, S. D., & Duraiswamy, S. (2026) · Chemical Engineering Science · doi:10.1016/j.ces.2026.125439
Organization of the Cytoskeleton: Studies in Microfluidic Drops
Dammann, C. (2014) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-4511
Metadata
- Authors
- Song, H., & Ismagilov, R. F.
- Affiliations
- University of Chicago (US)
- ORCID
- Ismagilov, Rustem F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-29
- Volume
- 125
- Issue
- 47
- Pages
- 14613-14619
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- PMC
- PMC1769313
- OpenAlex
- W2028894110
- Cited by
- 693
- References
- 45
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM08720, T32GM008720)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
- MeSH terms
- Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.