CoChat

Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents

Open access
Song, Helen, Ismagilov, Rustem F. · 2003 · Journal of the American Chemical Society

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.

Overview

Integrity signals

Registry

Crossref · 10.1021/ja0354566

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 46 references

Research works printed but not linked: 19

  1. Shastry M. C. R., 1998, Biophys. J., 74, 2721
  2. Tice J. D., 2003, Langmuir, 19, 9133
  3. Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
  4. Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
  5. Ali J. A., 1997, Science, 275, 380
  6. Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
  7. Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
  8. Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
  9. Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
  10. Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
  11. Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
  12. Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
  13. Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
  14. Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
  15. Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
  16. Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
  17. Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
  18. Haykin S., 1994, Neural Networks
  19. Song H., 2003, Appl. Phys. Lett.

Cited by

Items 101–200 of 692

Metadata

Authors
Song, H., & Ismagilov, R. F.
Affiliations
University of Chicago (US)
Venue
Journal of the American Chemical Society
Published
2003-10-29
Volume
125
Issue
47
Pages
14613-14619
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2028894110
Cited by
693
References
45
Citations by year
2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
FWCI
18.59
Type
journal article
Language
en
Open access
Locations
  • Journal of the American Chemical Society (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion)
Funders
  • National Institute of General Medical Sciences (GM08720, T32GM008720)
  • National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
Topics
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
Keywords
droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
MeSH terms
Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.