Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper describes a microfluidic chip for performing kinetic measurements with better than millisecond resolution. Rapid kinetic measurements in microfluidic systems are complicated by two problems: mixing is slow and dispersion is large. These problems also complicate biochemical assays performed in microfluidic chips. We have recently shown (Song, H.; Tice, J. D.; Ismagilov, R. F. Angew. Chem., Int. Ed. 2003, 42, 768-772) how multiphase fluid flow in microchannels can be used to address both problems by transporting the reagents inside aqueous droplets (plugs) surrounded by an immiscible fluid. Here, this droplet-based microfluidic system was used to extract kinetic parameters of an enzymatic reaction. Rapid single-turnover kinetics of ribonuclease A (RNase A) was measured with better than millisecond resolution using sub-microliter volumes of solutions. To obtain the single-turnover rate constant (k = 1100 +/- 250 s(-1)), four new features for this microfluidics platform were demonstrated: (i) rapid on-chip dilution, (ii) multiple time range access, (iii) biocompatibility with RNase A, and (iv) explicit treatment of mixing for improving time resolution of the system. These features are discussed using kinetics of RNase A. From fluorescent images integrated for 2-4 s, each kinetic profile can be obtained using less than 150 nL of solutions of reagents because this system relies on chaotic advection inside moving droplets rather than on turbulence to achieve rapid mixing. Fabrication of these devices in PDMS is straightforward and no specialized equipment, except for a standard microscope with a CCD camera, is needed to run the experiments. This microfluidic platform could serve as an inexpensive and economical complement to stopped-flow methods for a broad range of time-resolved experiments and assays in chemistry and biochemistry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Experimental conditions in the continuous DIB device promote rapid transport equilibration between droplet compartments due to the inherent recirculating flow found in droplets.28,29”
From Chiral lipid bilayers are enantioselectively permeable (2021) · doi:10.1038/s41557-021-00708-z · cites this paper as [28]
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationRaines, R. T. (1998) · Chemical Reviews · doi:10.1021/cr960427h · Cited by 937
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Leach, C. L., Greenspan, J. S., Rubenstein, S. D., Shaffer, T. H., Wolfson, M. R., Jackson, J. C., DeLemos, R., & Fuhrman, B. P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199609123351101 · Cited by 453
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citation
Research works printed but not linked: 19
- Shastry M. C. R., 1998, Biophys. J., 74, 2721
- Tice J. D., 2003, Langmuir, 19, 9133
- Chan C. K., 1997, Proc. Natl. Acad. Sci. U.S.A., 94, 1784
- Fang X. W., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 8523
- Ali J. A., 1997, Science, 275, 380
- Luo L. S., 2001, J. Am. Chem. Soc., 123, 11218
- Brazeau B. J., 2001, J. Am. Chem. Soc., 123, 11837
- Nelsen S. F., 1997, J. Am. Chem. Soc., 119, 5907
- Cherry J. P. F., 2001, J. Am. Chem. Soc., 123, 7286
- Kerby M., 2001, Electrophoresis, 22, 3923, 10.1002/1522-2683(200110)22:18<3916::AID-ELPS3916>3.0.CO;2-V · doi:10.1002/1522-2683(200110)22:18<3916::aid-elps3916>3.0.co;2-v
- Russell R., 2002, Proc. Natl. Acad. Sci. U.S.A., 99, 4271
- Jiang X. Y., 2003, J. Am. Chem. Soc., 125, 5295
- Wilson C. F., 2001, Single Molecule Spectroscopy: Nobel Symposium Lectures, 143
- Duggleby R., 1995, Enzyme Kinetics and Mechanism, Pt D, 249, 90
- Selwyn M., 1965, J. Biochim. Biophys. Acta, 105, 195
- Thompson J. E., 1994, J. Am. Chem. Soc., 116, 5468
- Witzel H., 1963, Prog. Nucleic Acid Res., 2, 258
- Haykin S., 1994, Neural Networks
- Song H., 2003, Appl. Phys. Lett.
Cited by
Items 201–300 of 692
A microfluidic reactor for rapid, low‐pressure proteolysis with on‐chip electrospray ionization
Liuni, P., Rob, T., & Wilson, D. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4391 · Cited by 73
Characterization of liquid–liquid mass transfer performance in a capillary microreactor system
Li, G., Shang, M., Song, Y., & Su, Y. (2017) · AIChE Journal · doi:10.1002/aic.15973 · Cited by 73
Microfluidic Studies of CO2 Sequestration by Frustrated Lewis Pairs
Voicu, D., Abolhasani, M., Choueiri, R. M., Lestari, G., Seiler, C., Ménard, G., Greener, J., Günther, A., Stephan, D. W., & Kumacheva, E. (2014) · Journal of the American Chemical Society · doi:10.1021/ja411601a · Cited by 72
Maged, A., Abdelbaset, R., Mahmoud, A. A. K., & ElKasabgy, N. A. (2022) · Drug Delivery · doi:10.1080/10717544.2022.2069878 · Cited by 78
“When the flow is deformed along a curved channel, the axisymmetric circulation flowing in each compartment breaks and the substances disperse making the twisting channel a significant route for better mixing (Figure 5(B)) (Song & Ismagilov, 2003; Demello, 2006).”
BackgroundSun, D., Cao, F., Cong, L., Xu, W., Chen, Q., Shi, W., & Xu, S. (2018) · Lab on a Chip · doi:10.1039/c8lc01006d · Cited by 71
Tanthapanichakoon, W., Aoki, N., Matsuyama, K., & Mae, K. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2006.01.047 · Cited by 71
Park, S.-Y., Pan, C., Wu, T., Kloss, C., Kalim, S., Callahan, C., Teitell, M. A., & Chiou, E. P. Y. (2008) · Applied Physics Letters · doi:10.1063/1.2906362 · Cited by 71
Micromixers and their applications in kinetic analysis of biochemical reactions
Liu, C., Li, Y., & Liu, B. (2019) · Talanta · doi:10.1016/j.talanta.2019.120136 · Cited by 72
Selva, B., Mirallès, V., Cantat, I., & Jullien, M.-C. (2010) · Lab on a Chip · doi:10.1039/c001900c · Cited by 70
Simultaneous measurement of reactions in microdroplets filled by concentration gradients
Damean, N., Olguin, L. F., Hollfelder, F., Abell, C., & Huck, W. T. S. (2009) · Lab on a Chip · doi:10.1039/b821021g · Cited by 69
Droplet dynamics passing through obstructions in confined microchannel flow
Chung, C., Lee, M., Char, K., Ahn, K. H., & Lee, S. J. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0636-x · Cited by 68
“Potentials of lab-on-a-chip technology have been realized with droplet manipulations in future applications, such as drug discoveries (Dittrich and Manz 2006), biochemical assays (Khnouf et al. 2009; Boedicker et al. 2008; Li et al. 2007; Taly et al. 2007; Griffiths and Tawfik 2006; Song and Ismagilov 2003), photonic…”
Chiral lipid bilayers are enantioselectively permeable
(2021) · doi:10.1038/s41557-021-00708-z · Cited by 68
Gu, H., & Ren, D. (2014) · Frontiers of Chemical Science and Engineering · doi:10.1007/s11705-014-1412-3 · Cited by 69
“[62] created an array of approximately100 fL droplets with different cell densities by introducing air bubbles over the wells made with biocompatible [69] resin SU-8 (photoresist) [70].”
MethodUltrahigh-Throughput Improvement and Discovery of Enzymes Using Droplet-Based Microfluidic Screening
Autour, A., & Ryckelynck, M. (2017) · Micromachines · doi:10.3390/mi8040128 · Cited by 70
“Finally, droplets can be incubated on-chip, either by storing them in dedicated chambers [52,53] and microarrays [54]; or by circulating them into various geometries of channels [55,56].”
BackgroundHigh‐throughput droplet‐based microfluidics for directed evolution of enzymes
Chiu, F. W. Y., & Stavrakis, S. (2019) · Electrophoresis · doi:10.1002/elps.201900222 · Cited by 66
Markey, A., Mohr, S., & Day, P. J. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.030 · Cited by 65
Passive Mixing inside Microdroplets
Chen, C., Zhao, Y., Wang, J., Zhu, P., Tian, Y., Xu, M., Wang, L., & Huang, X. (2018) · Micromachines · doi:10.3390/mi9040160 · Cited by 64
Deformation of a viscoelastic droplet passing through a microfluidic contraction
Harvie, D. J. E., Cooper-White, J. J., & Davidson, M. R. (2008) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/j.jnnfm.2008.05.002 · Cited by 63
Sharma, S., Srisa‐Art, M., Scott, S., Asthana, A., & Cass, A. E. G. (2012) · Methods in molecular biology · doi:10.1007/978-1-62703-134-9_15 · Cited by 63
Mesoscale Flow Chemistry: A Plug-Flow Approach to Reaction Optimisation
Wheeler, R. C., Benali, O., Deal, M. J., Farrant, E., Macdonald, S. J. F., & Warrington, B. H. (2007) · Organic Process Research & Development · doi:10.1021/op7000707 · Cited by 63
Wang, M., Slaney, T. R., Mabrouk, O. S., & Kennedy, R. T. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.023 · Cited by 62
“This design is a modification of previous reports, here a T-geometry channel with multiple water inlets was used or creating plugs of mixed composition (Song and Ismagilov, 2003; ang et al., 2008).”
Study on the kinetics of homogeneous enzyme reactions in a micro/nanofluidics device
Wang, C., Li, S., Wu, Z., Xu, J., Chen, H., & Xia, X. (2009) · Lab on a Chip · doi:10.1039/b915762j · Cited by 62
Wang, K., Lü, Y., Xia, Y., Shao, H., & Luo, G. S. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.02.072 · Cited by 62
Microfluidic-Based Droplets for Advanced Regenerative Medicine: Current Challenges and Future Trends
Nazari, H., Heirani‐Tabasi, A., Ghorbani, S., Eyni, H., Bazaz, S. R., Khayati, M., Gheidari, F., Moradpour, K., Kehtari, M., Tafti, S. M. A., et al. (2021) · Biosensors · doi:10.3390/bios12010020 · Cited by 63
“implementation of droplets in available high-throughput cell analysis techniques—such as polymerase chain reaction [77], DNA/RNA sequencing [78], enzyme kinetics [79] and assays [80], protein crystallization [81,82], protein expression quantification [83], protein quantification mass spectrometry (LC–MS), and GC–MS me…”
BackgroundInfluence of hydrodynamics on liquid mixing during Taylor flow in a microchannel
Su, Y., Chen, G., & Yuan, Q. (2011) · AIChE Journal · doi:10.1002/aic.12698 · Cited by 60
Liquid Tubule Formation and Stabilization Using Cellulose Nanocrystal Surfactants
Liu, X., Shi, S., Li, Y., Forth, J., Wang, D., & Russell, T. P. (2017) · Angewandte Chemie · doi:10.1002/ange.201706839 · Cited by 60
Küster, S. K., Pabst, M., Jefimovs, K., Zenobi, R., & Dittrich, P. S. (2014) · Analytical Chemistry · doi:10.1021/ac4041982 · Cited by 59
Rapid label-free DNA analysis in picoliter microfluidic droplets using FRET probes
Hsieh, A. T.-H., Pan, P. J.-H., & Lee, A. P. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0406-9 · Cited by 60
“3b), chaotic advection flow occurs within the droplet (Song and Ismagilov 2003; Liau et al. 2005; Muradoglu and Stone 2005) and allows the DNA sample and MB-BRCA1 to mix rapidly.”
BackgroundAn Approach To Extract Rate Constants from Reaction−Diffusion Dynamics in a Microchannel
Salmon, J., Dubrocq-Baritaud, C., Tabeling, P., Charier, S., Alcor, D., Jullien, L., & Ferrage, F. (2005) · Analytical Chemistry · doi:10.1021/ac0500838 · Cited by 58
Microfluidics with on-line dynamic light scattering for size measurements
Destremaut, F., Salmon, J., Qi, L., & Chapel, J. (2009) · Lab on a Chip · doi:10.1039/b906514h · Cited by 57
Jakieła, S., Korczyk, P. M., Makulska, S., Cybulski, O., & Garstecki, P. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.134501 · Cited by 57
Microfluidic Serial Dilution Circuit
Paegel, B. M., Grover, W. H., Skelley, A. M., Mathies, R. A., & Joyce, G. F. (2006) · Analytical Chemistry · doi:10.1021/ac0608265 · Cited by 57
Electrowetting-enhanced microfluidic device for drop generation
Gu, H., Malloggi, F., Vanapalli, S. A., & Mugele, F. G. (2008) · Applied Physics Letters · doi:10.1063/1.3013567 · Cited by 56
3D Droplet Microfluidic Systems for High-Throughput Biological Experimentation
Kang, D., Gong, X., Cho, S., Kim, J., Edel, J. B., Chang, S., Choo, J., & deMello, A. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02402 · Cited by 61
Singh, V. P., Jang, S., Vishwakarma, N. K., & Kim, D. (2018) · NPG Asia Materials · doi:10.1038/am.2017.209 · Cited by 55
Sarrazin, F., Salmon, J., Talaga, D., & Servant, L. (2008) · Analytical Chemistry · doi:10.1021/ac7020147 · Cited by 54
Baker, C. A., & Roper, M. G. (2012) · Analytical Chemistry · doi:10.1021/ac300100b · Cited by 54
Xie, Y., Ahmed, D., Lapsley, M. I., Lin, S. S., Nawaz, A., Wang, L., & Huang, T. J. (2012) · Analytical Chemistry · doi:10.1021/ac301590y · Cited by 54
Bioinspired Anti‐Plateau–Rayleigh‐Instability on Dual Parallel Fibers
Wang, P., Zhou, J., Xu, B., Lu, C., Meng, Q., & Liu, H. (2020) · Advanced Materials · doi:10.1002/adma.202003453 · Cited by 54
Monitoring a Reaction at Submillisecond Resolution in Picoliter Volumes
Huebner, A., Abell, C., Huck, W. T. S., Baroud, C. N., & Hollfelder, F. (2011) · Analytical Chemistry · doi:10.1021/ac103234a · Cited by 53
Automated generation of libraries of nL droplets
Kamiński, T. S., Jakieła, S., Czekalska, M. A., Postek, W., & Garstecki, P. (2012) · Lab on a Chip · doi:10.1039/c2lc40540g · Cited by 53
Ben‐Yoav, H., Dykstra, P. H., Bentley, W. E., & Reza Ghodssi, A. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.069 · Cited by 53
Acoustofluidic Chemical Waveform Generator and Switch
Ahmed, D., Muddana, H. S., Lu, M., French, J. B., Özçelik, A., Ye, F., Butler, P. J., Benkovic, S. J., Manz, A., & Huang, T. J. (2014) · Analytical Chemistry · doi:10.1021/ac5033676 · Cited by 53
Recent topics of functionalized organolithiums using flow microreactor chemistry
Nagaki, A. (2019) · Tetrahedron Letters · doi:10.1016/j.tetlet.2019.07.014 · Cited by 53
Balamurugan, S., Kim, N., Lee, W., Spivak, D. A., Nikitopoulos, D. E., McCarley, R. L., & Soper, S. A. (2011) · Langmuir · doi:10.1021/la200298n · Cited by 52
Solvas, X. C. I., Srisa‐Art, M., deMello, A. J., & Edel, J. B. (2010) · Analytical Chemistry · doi:10.1021/ac100055g · Cited by 52
Self-Assembled Peptide Monolayers as a Toxin Sensing Mechanism within Arrayed Microchannels
Frisk, M. L., Tepp, W. H., Johnson, E. A., & Beebe, D. J. (2009) · Analytical Chemistry · doi:10.1021/ac802707u · Cited by 52
Simulation of Mixing within Drops due to Surface Tension Variations
Blanchette, F. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.074501 · Cited by 52
High-Throughput Screening in Protein Engineering: Recent Advances and Future Perspectives
Wójcik, M., Telzerow, A., Quax, W. J., & Boersma, Y. L. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms161024918 · Cited by 52
“Other modules can measure reaction kinetics in microfluidic systems [63] and sort droplets [64] (Figure 7).”
BackgroundMicromixer based on viscoelastic flow instability at low Reynolds number
Lam, Y. C., Gan, H. Y., Nguyen, N., & Lie, H. (2009) · Biomicrofluidics · doi:10.1063/1.3108462 · Cited by 52
Determination of Kinetic Parameters, Km and kcat, with a Single Experiment on a Chip
Jambovane, S. R., Duin, E. C., Kim, S., & Hong, J. W. (2009) · Analytical Chemistry · doi:10.1021/ac8020938 · Cited by 51
Hess, D., Rane, A. S., deMello, A. J., & Stavrakis, S. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00766 · Cited by 50
Microfluidic droplet grating for reconfigurable optical diffraction
Yu, J. Q., Yang, Y., Liu, A. Q., Chin, L. K., & Zhang, X. (2010) · Optics Letters · doi:10.1364/ol.35.001890 · Cited by 50
Griffin, M. A., Davis, J., & Strobel, S. A. (2013) · Biochemistry · doi:10.1021/bi401325c · Cited by 53
Theberge, A. B., Whyte, G., & Huck, W. T. S. (2010) · Analytical Chemistry · doi:10.1021/ac1005316 · Cited by 50
Self-Regulated, Droplet-Based Sample Chopper for Microfluidic Absorbance Detection
Deal, K. S., & Easley, C. J. (2011) · Analytical Chemistry · doi:10.1021/ac202791d · Cited by 49
Jambovane, S., Kim, D. J., Duin, E. C., Kim, S.-K., & Hong, J. W. (2011) · Analytical Chemistry · doi:10.1021/ac103217p · Cited by 49
Tunable Droplet Manipulation and Characterization by ac-DEP
Zhao, K., & Li, D. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b14430 · Cited by 48
Continuous- versus Segmented-Flow Microfluidic Synthesis in Materials Science
Gonidec, M., & Puigmartí‐Luis, J. (2018) · Crystals · doi:10.3390/cryst9010012 · Cited by 51
“Spontaneous mixing of droplets flowing in straight channels for different (a) experimental (reprinted with permission from [14], copyright 2003 American Chemical Society), and (b) theoretical studies (reprinted from [40] with permission from Elsevier).”
BackgroundInfluentialMicro-Raman Technology to Interrogate Two-Phase Extraction on a Microfluidic Device
Nelson, G. L., Asmussen, S. E., Lines, A. M., Casella, A. J., Bottenus, D., Clark, S. B., & Bryan, S. A. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04330 · Cited by 47
Analysis of biomolecular condensates and protein phase separation with microfluidic technology
Linsenmeier, M., Kopp, M. R. G., Stavrakis, S., deMello, A. J., & Arosio, P. (2020) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2020.118823 · Cited by 48
Millisecond treatment of cells using microfluidic devices via two-step carrier-medium exchange
Yamada, M., Kobayashi, J., Yamato, M., Seki, M., & Okano, T. (2008) · Lab on a Chip · doi:10.1039/b718281c · Cited by 47
Effect of Viscosity on the Hydrodynamics of Liquid Processes in Microchannels
Su, Y., Chen, G., & Yuan, Q. (2014) · Chemical Engineering & Technology · doi:10.1002/ceat.201300468 · Cited by 46
On the hydrodynamics of liquid–liquid slug flow capillary microreactors
Kashid, M. N., Rivas, D. F., Agar, D. W., & Turek, S. (2008) · Asia-Pacific Journal of Chemical Engineering · doi:10.1002/apj.127 · Cited by 46
“Experimental results on flow regime, slug size and particle image velocimetry along with corresponding complementary start-of-the-art CFD simulations are discussed in detail.”
MethodIdentification of rare progenitor cells from human periosteal tissue using droplet microfluidics
Srisa‐Art, M., Bonzani, I. C., Williams, A., Stevens, M. M., deMello, A. J., & Edel, J. B. (2009) · The Analyst · doi:10.1039/b910472k · Cited by 45
Small-angle X-ray scattering in droplet-based microfluidics
Stehle, R., Goerigk, G., Wallacher, D., Ballauff, M., & Seiffert, S. (2013) · Lab on a Chip · doi:10.1039/c3lc41291a · Cited by 45
Droplet Microfluidic Technique: Mirodroplets Formation and Manipulation
Chen, J., & Jiang, J. (2012) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(11)60567-7 · Cited by 45
Microdroplet generation in gaseous and liquid environments
Ben‐Tzvi, P., & Rone, W. S. (2009) · Microsystem Technologies · doi:10.1007/s00542-009-0962-7 · Cited by 44
“One use of microreactors has been to experimentally measure reaction kinetics (Song and Ismagilov 2003).”
BackgroundSampling from Nanoliter Plugs via Asymmetrical Splitting of Segmented Flow
Nie, J., & Kennedy, R. T. (2010) · Analytical Chemistry · doi:10.1021/ac101723x · Cited by 44
Chang, C., & Yang, R. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/8/003 · Cited by 44
“Therefore, the rapid mixers (sub-millisecond) have also been developed and successfully integrated in microfluidic platforms, and allowed for an accurate description of fast reaction kinetics [13, 14].”
Biotransformations in Microflow Systems: Bridging the Gap between Academia and Industry
Plazl, P. Ž. (2017) · Journal of Flow Chemistry · doi:10.1556/1846.2017.00021 · Cited by 45
Fast Self-Assembly Kinetics of Quantum Dots and a Dendrimeric Peptide Ligand
Wang, J., Jiang, P., Han, Z., Qiu, L., Wang, C., Zheng, B., & Xia, J. (2012) · Langmuir · doi:10.1021/la301227r · Cited by 43
Wang, Z.-H., Yan, X.-Y., Zhou, Q.-Z., Wang, Q., Zhao, D., & Wu, H.-K. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c00335 · Cited by 42
Process intensification of H2O2 extraction using gas–liquid–liquid microdispersion system
Tan, J., Liu, Z., Lü, Y., Xu, J., & Luo, G. (2011) · Separation and Purification Technology · doi:10.1016/j.seppur.2011.04.030 · Cited by 43
Massively parallel and multiparameter titration of biochemical assays with droplet microfluidics
Baccouche, A., Okumura, S., Sieskind, R., Henry, E., Aubert-Kato, N., Bredèche, N., Bartolo, J.-F., Taly, V., Rondelez, Y., Fujii, T., et al. (2017) · Nature Protocols · doi:10.1038/nprot.2017.092 · Cited by 50
Li, X., Hu, J., & Easley, C. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00616d · Cited by 43
Droplet-based optofluidic systems for measuring enzyme kinetics
Hess, D., Yang, T., & Stavrakis, S. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02294-z · Cited by 49
“First, they are perfectly suited to highthroughput screening of a variety of reaction conditions due to their ability to create huge numbers of discrete droplets with controllable payloads, and second, rapid reactions can be probed with precision, due to ultra-fast reagent mixing via chaotic advection [62].”
BackgroundMethodInfluentialHess, D., Dockalova, V., Kokkonen, P., Bednář, D., Damborský, J., deMello, A. J., Prokop, Z., & Stavrakis, S. (2021) · Chem · doi:10.1016/j.chempr.2021.02.011 · Cited by 43
“The variation of intensity as a function of time was modeled, as described previously.(13) Specifically, we define the time at which 50% of mixing is complete as the time at which an enzymatic reaction starts (t0) and the time at which 90% mixing is complete as the time resolution of our system (Dtmix;90%).”
Fluorescence Lifetime Imaging of Mixing Dynamics in Continuous-Flow Microdroplet Reactors
Srisa‐Art, M., deMello, A. J., & Edel, J. B. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.014502 · Cited by 43
Jiang, L., Zeng, Y., Zhou, H., Qu, J. Y., & Yao, S. (2012) · Biomicrofluidics · doi:10.1063/1.3673254 · Cited by 47
Enzymatic microreactors in biocatalysis: history, features, and future perspectives
Laurenti, E., & Vianna, A. D. S. (2016) · Biocatalysis · doi:10.1515/boca-2015-0008 · Cited by 43
Xu, K., Tostado, C. P., Xu, J., Lü, Y., & Luo, G. (2014) · Lab on a Chip · doi:10.1039/c3lc51222c · Cited by 42
Droplet-based microfluidics for dose–response assay of enzyme inhibitors by electrochemical method
Gu, S., Lu, Y., Ding, Y., Li, L., Zhang, F., & Wu, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.08.016 · Cited by 42
Meier, M., Kennedy‐Darling, J., Choi, S. H., Norstrom, E. M., Sisodia, S. S., & Ismagilov, R. F. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805225 · Cited by 43
Self-citationA Barcode-Free Combinatorial Screening Platform for Matrix Metalloproteinase Screening
Rane, T. D., Zec, H. C., & Wang, T. (2014) · Analytical Chemistry · doi:10.1021/ac504330x · Cited by 41
SadAbadi, H., Packirisamy, M., & Wüthrich, R. (2013) · RSC Advances · doi:10.1039/c3ra40910d · Cited by 41
Building droplet-based microfluidic systems for biological analysis
Niu, X., & deMello, A. J. (2012) · Biochemical Society Transactions · doi:10.1042/bst20120005 · Cited by 41
Kinetics of nanocrystal synthesis in a microfluidic reactor: theory and experiment
Maceiczyk, R. M., Bezinge, L., & deMello, A. J. (2016) · Reaction Chemistry & Engineering · doi:10.1039/c6re00073h · Cited by 42
Thermodynamic perspectives on liquid–liquid droplet reactors for biochemical applications
Wei, Y., Cheng, G., Ho, H., Ho, Y., & Yong, K. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00541b · Cited by 44
Microfluidic Droplet Manipulations and Their Applications
Simon, M. G., & Lee, A. P. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3265-4_2 · Cited by 41
“The advantages of rapid mixing in droplet microfluidics systems have motivated new methods for directly observing the kinetics of reactions with millisecond resolution [43], and will allow for higher throughput testing for many different types of applications.”
MethodGielen, F., Buryska, T., Vliet, L. V., Butz, M., Damborsky, J., Prokop, Z., & Hollfelder, F. (2015) · Analytical Chemistry · doi:10.1021/ac503336g · Cited by 40
Mikrotröpfchen in Mikrofluidiksystemen: eine Technik für Entdeckungen in der Chemie und Biologie
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie · doi:10.1002/ange.200906653 · Cited by 41
A parametric study of droplet deformation through a microfluidic contraction: Shear thinning liquids
Harvie, D. J. E., Davidson, M. R., Cooper-White, J. J., & Rudman, M. J. (2006) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2006.12.002 · Cited by 40
Droplet-Based Millifluidics as a New Miniaturized Tool to Investigate Polymerization Reactions
Lorber, N., Pavageau, B., & Mignard, E. (2010) · Macromolecules · doi:10.1021/ma100233r · Cited by 40
h ν SABR: Photochemical Dose–Response Bead Screening in Droplets
Price, A. K., MacConnell, A. B., & Paegel, B. M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04811 · Cited by 39
Automated high-throughput generation of droplets
Guzowski, J., Korczyk, P. M., Jakieła, S., & Garstecki, P. (2011) · Lab on a Chip · doi:10.1039/c1lc20595a · Cited by 39
Rapid and inexpensive fabrication of polymeric microfluidic devices via toner transfer masking
Easley, C. J., Benninger, R. K. P., Shaver, J. H., Head, W. S., & Piston, D. W. (2009) · Lab on a Chip · doi:10.1039/b816575k · Cited by 41
Effects of Ultrasmall Orifices on the Electrogeneration of Femtoliter-Volume Aqueous Droplets
He, M., Kuo, J. S., & Chiu, D. T. (2006) · Langmuir · doi:10.1021/la060259g · Cited by 39
Benz, C., Retzbach, H., Nagl, S., & Belder, D. (2013) · Lab on a Chip · doi:10.1039/c3lc00057e · Cited by 38
Rojahn, P., Hessel, V., Nigam, K. D. P., & Schael, F. (2018) · Chemical Engineering Science · doi:10.1016/j.ces.2018.02.031 · Cited by 38
Metadata
- Authors
- Song, H., & Ismagilov, R. F.
- Affiliations
- University of Chicago (US)
- ORCID
- Ismagilov, Rustem F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-29
- Volume
- 125
- Issue
- 47
- Pages
- 14613-14619
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- PMC
- PMC1769313
- OpenAlex
- W2028894110
- Cited by
- 693
- References
- 45
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 14 · 2023: 16 · 2022: 18 · 2021: 29 · 2020: 17 · 2019: 26 · 2018: 30 · 2017: 22 · 2016: 28 · 2015: 29 · 2014: 38 · 2013: 48 · 2012: 55
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM08720, T32GM008720)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001903)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- droplet microfluidics, single-turnover kinetics, ribonuclease A, enzyme kinetics, chaotic advection, rapid mixing, PDMS microfluidic device, fluorescence imaging
- MeSH terms
- Biocompatible Materials, Kinetics, Microchemistry, Ribonuclease, Pancreatic, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.