A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 401–500 of 1,000
Simultaneously improving the sensitivity and absolute accuracy of CPT magnetometer
Liang, S., Yang, G., Xu, Y., Lin, Q., Liu, Z., & Chen, Z. (2014) · Optics Express · doi:10.1364/oe.22.006837 · Cited by 29
Spin-noise spectrum of hot vapor atoms in an anti-relaxation-coated cell
Tang, Y., Ya, W., Cai, L. C., & Zhao, K. (2020) · Physical Review A · doi:10.1103/physreva.101.013821 · Cited by 31
Integrable quantum many-body sensors for AC field sensing
Mishra, U., & Bayat, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-17381-y · Cited by 44
“(1) can be solved exactly using Jordan-Wigner transformation (JW), as elaborated in [1, 2].”
MethodZhang, J., Liu, K., Zhang, J., Wang, Z., & Shang, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3120375 · Cited by 33
Zhao, F., Wang, W., Zhou, W., & Zhou, X. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac74f5 · Cited by 29
Laser-written vapor cells for chip-scale atomic sensing and spectroscopy
Lucivero, V. G., Zanoni, A., Corrielli, G., Osellame, R., & Mitchell, M. W. (2022) · Optics Express · doi:10.1364/oe.469296 · Cited by 34
Integrated Polarization-Splitting Grating Coupler for Chip-Scale Atomic Magnetometer
Hu, J., Lu, J., Liang, Z., Liu, L., Wang, W., Zhou, P., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12070529 · Cited by 29
“Atomic devices based on the light–atom interaction mechanism such as atomic clocks [1,2], atomic magnetometers [3,4], nuclear magnetic resonance gyroscopes [5,6], and laser frequency stabilizers [7,8] have experienced rapid development in recent decades.”
BackgroundA novel low-noise Mu-metal magnetic shield with winding shape
Ma, D., Lu, J., Fang, X., Dou, Y., Wang, K., Gao, Y., Li, S., & Han, B. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113884 · Cited by 29
High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer
Yao, H., Maddox, B., & Renzoni, F. (2022) · Optics Express · doi:10.1364/oe.476016 · Cited by 34
“This limitation is usually overcome by operating the atomic magnetometer in a magnetically shielded environment or, in case of spatially rapidly decaying field, by the use of differential measurements with a multiple sensor set-up [2,3,9–17].”
Absolute absorption on the potassium D lines: theory and experiment
Hanley, R., Gregory, P. D., Hughes, I. G., & Cornish, S. (2015) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/48/19/195004 · Cited by 27
“These range from all optical delay lines [1], quantum atomic memories [2, 3, 4, 5], clocks [6, 7] and compact magnetometry [8, 9, 10] to name but a few.”
BackgroundUltra‐Low‐Field NMR Relaxation and Diffusion Measurements Using an Optical Magnetometer
Ganssle, P. J., Shin, H. D., Seltzer, S. J., Bajaj, V. S., Ledbetter, M. P., Budker, D., Knappe, S. A., Kitching, J. E., & Pines, A. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201403416 · Cited by 29
Remote detection of nuclear magnetic resonance with an anisotropic magnetoresistive sensor
Verpillat, F., Ledbetter, M. P., Xu, S., Michalak, D. J., Hilty, C., Bouchard, L., Antonijevic, S., Budker, D., & Pines, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712129105 · Cited by 29
Magnetometer based on the opto-electronic microwave oscillator
Matsko, A. B., Strekalov, D., & Maleki, L. (2004) · Optics Communications · doi:10.1016/j.optcom.2004.11.047 · Cited by 28
Detection and analysis of MEG signals in occipital region with double-channel OPM sensors
Zhang, X., Chen, C.-Q., Zhang, M., Ma, C., Zhang, Y., Wang, H., Guo, Q., Hu, T., Liu, Z., Chang, Y., et al. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108948 · Cited by 29
Bai, L., Wen, X., Yang, Y.-L., Zhang, L., He, J., Wang, Y., & Wang, J. (2021) · Journal of Optics · doi:10.1088/2040-8986/ac1b7c · Cited by 32
Metasurface enabled on-chip double-beam scheme for SERF atomic magnetometer
Liang, Z., Zhou, B., Lu, J., Liu, Y., Hu, J., Zhou, P., Wang, W., Liu, L., Hu, G., & Ye, M. (2022) · Optics Communications · doi:10.1016/j.optcom.2022.128850 · Cited by 28
Note: Detection of a single cobalt microparticle with a microfabricated atomic magnetometer
Maser, D. L., Pandey, S., Ring, H., Ledbetter, M. P., Knappe, S., Kitching, J., & Budker, D. (2011) · Review of Scientific Instruments · doi:10.1063/1.3626505 · Cited by 28
“The magnetometer operates in the spin-exchange relaxationfree (SERF) regime.”
BackgroundInfluentialMagnetic induction measurements using an all-optical 87Rb atomic magnetometer
Wickenbrock, A., Tricot, F., & Renzoni, F. (2013) · Applied Physics Letters · doi:10.1063/1.4848196 · Cited by 28
Nondestructive in-line sub-picomolar detection of magnetic nanoparticles in flowing complex fluids
Bougas, L., Langenegger, L. D., Mora, C. A., Zeltner, M., Stark, W. J., Wickenbrock, A., Blanchard, J. W., & Budker, D. (2018) · Scientific Reports · doi:10.1038/s41598-018-21802-2 · Cited by 32
Yang, Y., Luo, S., Wang, W., Gao, X., Yao, X., & Wu, T. (2024) · NeuroImage Clinical · doi:10.1016/j.nicl.2024.103608 · Cited by 41
“Many research teams around the world have since reported on SERF atomic magnetometers (Allred et al., 2002; Kominis et al., 2003).”
Design and Analysis of a High-Sensitivity Atomic Magnetic Gradiometer With Adjustable Baseline
Zhang, Y., Tang, J., Xu, X., Wang, Z., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3544375 · Cited by 27
“The intrinsic sensitivity of the gradiometer, which is denoted as δ B i in (8), is a crucial parameter that represents the lowest achievable noise level for a specific mag-netometer configuration, which cannot be further reduced by other technical methods [12].”
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography
Li, J., Du, P., Fu, J., Wang, X.-T., Zhou, Q., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040703 · Cited by 27
Fu, Y., Sun, J., Ruan, J., & Quan, W. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113487 · Cited by 27
Cavity enhanced atomic magnetometry
Crepaz, H., Ley, L. Y., & Dumke, R. (2015) · Scientific Reports · doi:10.1038/srep15448 · Cited by 33
Production and detection of atomic hexadecapole at Earth’s magnetic field
Acosta, V. M., Auzinsh, M. P., Gawlik, W., Grisins, P., Higbie, J. M., Kimball, D. F. J., Krzemień, L., Ledbetter, M. P., Pustelny, S., Rochester, S., et al. (2008) · Optics Express · doi:10.1364/oe.16.011423 · Cited by 27
Bogi, A., Marinelli, C., Burchianti, A., Mariotti, E., Moi, L., Gozzini, S., Marmugi, L., & Lucchesini, A. (2009) · Optics Letters · doi:10.1364/ol.34.002643 · Cited by 27
Ito, Y., Ohnishi, H., Kamada, K., & Kobayashi, T. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2199966 · Cited by 28
Microfabricated atomic magnetometers and applications
Kitching, J. E., Knappe, S. A., Shah, V., Schwindt, P. D. D., Griffith, C., Jiménez, R., Preusser, J., Liew, L., & Moreland, J. (2008) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2008.4623107 · Cited by 32
“This effect was used recently to great advantage in magnetometry: the suppression of spin-exchange broadening can lead in the case of (39)K to magnetometer sensitivities up to one hundred times better than can be achieved under spin-exchange-broadened conditions [20, 21].”
BackgroundA magnetometer suitable for measurement of the Earth's field based on transient atomic response
Lenci, L., Barreiro, S., Valente, P., Failache, H., & Lezama, A. (2012) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/45/21/215401 · Cited by 27
Nonlinear Amplification of Small Spin Precession Using Long-Range Dipolar Interactions
Ledbetter, M. P., Savukov, I., & Romalis, M. V. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.060801 · Cited by 27
Self-citationRealization of coherent optically dense media via buffer-gas cooling
Hong, T., Gorshkov, A. V., Patterson, D., Zibrov, A. S., Doyle, J. M., Lukin, M. D., & Prentiss, M. G. (2009) · Physical Review A · doi:10.1103/physreva.79.013806 · Cited by 24
Yuan, Z., Liu, Y., Lin, S., Li, C., Tang, J., Lei, G., & Zhai, Y. (2024) · Measurement · doi:10.1016/j.measurement.2024.115223 · Cited by 29
Magnetic Resonance Based Atomic Magnetometers
Weis, A., Bison, G., & Grujić, Z. D. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_13 · Cited by 28
Universal Quantum Magnetometry with Spin States at Equilibrium
Troiani, F., & Paris, M. G. A. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.260503 · Cited by 31
Hu, Q., Freier, C., Sun, Y., Leykauf, B., Schkolnik, V., Yang, J. J., Krutzik, M., & Peters, A. (2018) · Physical Review A · doi:10.1103/physreva.97.013424 · Cited by 27
Plasmonic Enhanced EIT and Velocity Selective Optical Pumping Measurements with Atomic Vapor
Talker, E., Arora, P., Barash, Y., Stern, L., & Levy, U. (2018) · ACS Photonics · doi:10.1021/acsphotonics.7b01284 · Cited by 25
Microfabricated Vapor Cells with Reflective Sidewalls for Chip Scale Atomic Sensors
Han, R., You, Z., Zhang, F., Xue, H., & Ruan, Y. (2018) · Micromachines · doi:10.3390/mi9040175 · Cited by 26
“the superconducting quantum interference device (SQUID), which is known as the state-of-the-art most sensitive magnetometer [5].”
BackgroundZhang, H., Zou, S., Quan, W., Chen, X., & Fang, J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2929283 · Cited by 28
“The output signal f (v) and the sweeping frequency v can be fitted according to a Lorentzian line shape [30]”
MethodYang, K., Lu, J., Ding, M., Zhao, J., Ma, D., Li, Y., Xing, B., Han, B., & Fang, J. (2019) · IEEE Access · doi:10.1109/access.2019.2935034 · Cited by 26
“For example, the sensitivity of some ultrahigh-sensitivity atomic magnetometers is limited by the magnetic noise generated by the innermost layer of the magnetic shield itself [3], [4].”
BackgroundLong, T., Han, B., Song, X., Suo, Y., Jia, L., & Ren, W. (2022) · Photonic Sensors · doi:10.1007/s13320-023-0684-y · Cited by 29
“16 fT/Hz has been demonstrated in Romalis’s laboratory [29, 30].”
BackgroundAll-optical magnetometry for NMR detection in a micro-Tesla field and unshielded environment
Bevilacqua, G., Biancalana, V., Dancheva, Y. V., & Moi, L. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.09.013 · Cited by 26
Optimum shell separation for closed axial cylindrical magnetic shields
Paperno, E., Peliwal, S., Romalis, M. V., & Plotkin, A. (2005) · Journal of Applied Physics · doi:10.1063/1.1854254 · Cited by 26
Self-citationHigh Frequency Atomic Magnetometer by Use of Electromagnetically Induced Transparency
Katsoprinakis, G. E., Petrosyan, D., & Kominis, I. K. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.230801 · Cited by 29
Self-citationSuppression of spin-exchange relaxation in tilted magnetic fields within the geophysical range
Scholtes, T., Pustelny, S., Fritzsche, S., Schultze, V., Stolz, R., & Meyer, H. (2016) · Physical Review A · doi:10.1103/physreva.94.013403 · Cited by 27
Nuclear Quadrupole Resonance Detection of Explosives
Miller, J. B. (2007) · Elsevier eBooks · doi:10.1016/b978-044452204-7/50026-2 · Cited by 26
Ding, Z., Long, X., Yuan, J., Fan, Z., & Luo, H. (2016) · Scientific Reports · doi:10.1038/srep32605 · Cited by 26
Quantitative study of optical pumping in the presence of spin-exchange relaxation
Shi, Y., Scholtes, T., Grujić, Z. D., Lebedev, V., Dolgovskiy, V., & Weis, A. (2018) · Physical Review A · doi:10.1103/physreva.97.013419 · Cited by 28
Magnetometry with entangled atomic samples
Petersen, V., Madsen, L. B., & Mølmer, K. (2005) · Physical Review A · doi:10.1103/physreva.71.012312 · Cited by 28
Mitra, S., Dey, S., Hossain, M. M., Ghosh, P. N., & Ray, B. (2013) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/46/7/075002 · Cited by 26
Kumar, M. A., & Singh, S. P. (2009) · Physical Review A · doi:10.1103/physreva.79.063821 · Cited by 27
Yang, J., Zhang, X., Shi, M., Yuan, S., Wang, L., & Han, B. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3314921 · Cited by 25
“I N RECENT decades, the development of increasingly sensitive magnetometers [1], [2] has contributed significantly to numerous studies and applications of extremely weak magnetic field measurements, including fundamental physics [3], biomedical science [4], and industrial applications [5].”
BackgroundFree-induction-decay 4 He magnetometer using a multipass cell
Yi, K., Liu, Y., Wang, B., Xiao, W., Sheng, D., Peng, X., & Guo, H. M. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.014084 · Cited by 27
Toward liquid cell quantum sensing: Ytterbium complexes with ultranarrow absorption
Shin, A. J., Zhao, C., Shen, Y., Dickerson, C. E., Li, B. Y., Roshandel, H., Bím, D., Atallah, T. L., Oyala, P. H., He, Y., et al. (2024) · Science · doi:10.1126/science.adf7577 · Cited by 33
Imaging Magnetic Nanoparticle Distributions by Atomic Magnetometry-Based Susceptometry
Colombo, S., Lebedev, V., Tonyushkin, A., Pengue, S., & Weis, A. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2937670 · Cited by 26
“The decoupling is most efficient with magnetic sensors that can detect DC, or low-frequency fields, such as fluxgates, SQUIDs, or, as in our case, AMs.”
InfluentialTowards the Non-Zero Field Cesium Magnetic Sensor Array for Magnetoencephalography
Petrenko, M. V., Dmitriev, S. P., Pazgalev, A. S., Ossadtchi, A. E., & Vershovskii, A. K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3089455 · Cited by 26
Zhang, G., Zeng, H., Tan, G., & Lin, Q. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3156814 · Cited by 26
Highly Sensitive Tunable Magnetometer Based on Superconducting Quantum Interference Device
Vettoliere, A., & Granata, C. (2023) · Sensors · doi:10.3390/s23073558 · Cited by 27
Shao, Q., Lei, X., Jiang, L., Zhu, J., Zou, Y., Fang, C., Liang, X., Song, X., & Quan, W. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3314810 · Cited by 26
“The hot air heating method realizes the heating of the cell through thermal convection [15], [16], [17].”
MethodLevel-crossing absorption with narrow spectral width in Rb vapor with buffer gas
Yu, Y.-J., Lee, H. J., Bae, I., Noh, H., & Moon, H. S. (2010) · Physical Review A · doi:10.1103/physreva.81.023416 · Cited by 23
Spin-noise correlations and spin-noise exchange driven by low-field spin-exchange collisions
Dellis, A. T., Loulakis, M., & Kominis, I. K. (2014) · Physical Review A · doi:10.1103/physreva.90.032705 · Cited by 29
Self-citationZero- to low-field MRI with averaging of concomitant gradient fields
Meriles, C. A., Sakellariou, D., Trabesinger, A. H., Demas, V., & Pines, A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409115102 · Cited by 25
Search for exotic spin-dependent interactions with a spin-exchange relaxation-free magnetometer
Chu, P.-H., Kim, Y. J., & Savukov, I. (2016) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.94.036002 · Cited by 25
Noise reduction in optically pumped magnetometer assemblies
Schultze, V., IJsselsteijn, R. P. J., & Meyer, H. ‐. (2010) · Applied Physics B · doi:10.1007/s00340-010-4084-9 · Cited by 24
Zhao, K., Schaden, M., & Wu, Z. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.073201 · Cited by 25
Zhao, K., & Wu, Z. (2006) · Applied Physics Letters · doi:10.1063/1.2424657 · Cited by 25
Collision-induced spin exchange of alkali-metal atoms with H3e : Anab initiostudy
Tscherbul, T. V., Zhang, P., Sadeghpour, H. R., & Dalgarno, A. (2009) · Physical Review A · doi:10.1103/physreva.79.062707 · Cited by 25
Mode analysis of spin field of thermal atomic ensembles
Wang, W., Xia, M., Quan, W., & Wei, K. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad4912 · Cited by 25
Radio-Frequency Magnetometry Based on Parametric Resonances
Xiao, W., Liu, X., Wu, T., Peng, X., & Guo, H. M. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.093201 · Cited by 26
Chip-Scale Integration of Nanophotonic-Atomic Magnetic Sensors
Sebbag, Y., Naiman, A., Talker, E., Barash, Y., & Levy, U. (2020) · ACS Photonics · doi:10.1021/acsphotonics.0c01473 · Cited by 24
Transient dynamics of atomic spin in the spin-exchange-relaxation-free regime
Tang, J., Yin, Y., Zhai, Y., Zhou, B., Han, B., Yang, H., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.418776 · Cited by 27
Liu, F., Duan, L., Fan, W., Pang, H., Liu, S., & Quan, W. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3138831 · Cited by 25
Effects of Different Head Models in Wearable OPM-MEG
Cao, F., An, N., Wang, W., Xu, W., Li, W., Wang, C., Xiang, M., Gao, Y., & Ning, X. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3192287 · Cited by 26
High-sensitivity pump–probe atomic magnetometer based on single fiber-coupled
Zhao, B., Tang, J., Yang, H., Li, L., Zhang, Y., Liu, Y., & Zhai, Y. (2022) · Optics & Laser Technology · doi:10.1016/j.optlastec.2022.109025 · Cited by 25
Gao, X., Yu, C., Zhang, S.-C., Lin, H.-B., Guo, J., Ma, M., Feng, Z., & Sun, F.-W. (2023) · Diamond and Related Materials · doi:10.1016/j.diamond.2023.110348 · Cited by 26
On-chip integrated non-magnetic heating devices for quantum sensing applications
Zhou, P., Wang, Y., Hu, Z., Hu, G., Wang, A., Liang, Z., Hu, J., Liu, L., & Ye, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.114578 · Cited by 25
Taulu, S., Simola, J., Nenonen, J., & Parkkonen, L. T. (2014) · Springer eBooks · doi:10.1007/978-3-642-33045-2_2 · Cited by 31
Push-Pull Laser-Atomic Oscillator
Jau, Y., & Happer, W. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.223001 · Cited by 24
Light-shift measurement and suppression in atomic spin gyroscope
Fang, J., Wan, S., Chen, Y., & Li, R. (2012) · Applied Optics · doi:10.1364/ao.51.007714 · Cited by 23
Scanning Imaging of Magnetic Nanoparticles for Quantitative Molecular Imaging
Yao, L., Jamison, A. C., & Xu, S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201002830 · Cited by 24
Spin-exchange relaxation-free magnetic gradiometer with dual-beam and closed-loop Faraday modulation
Fang, J., Wan, S., Qin, J., Zhang, C., & Quan, W. (2014) · Journal of the Optical Society of America B · doi:10.1364/josab.31.000512 · Cited by 24
Circular dichroism of RbHe and RbN 2 molecules
Lancor, B., Babcock, E., Wyllie, R., & Walker, T. G. (2010) · Physical Review A · doi:10.1103/physreva.82.043435 · Cited by 24
Kamada, K., Taue, S., & Kobayashi, T. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.056602 · Cited by 25
Direct Photochemical Functionalization of Si(111) with Undecenol
Zhong, Y. L., & Bernasek, S. L. (2011) · Langmuir · doi:10.1021/la104143r · Cited by 29
The development of a multichannel atomic magnetometer array for fetal magnetocardiography
Wylie, R. B. (2012) · Cited by 33
Magnetic noise calculation of mu-metal shields at extremely low frequencies for atomic devices
Ma, D., Ding, M., Lu, J., Zhao, J., Yang, K., Fang, X., Wang, K., Zhang, N., & Han, B. (2020) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/abbe4b · Cited by 23
Dual-Mode Dead-Zone-Free Double-Resonance Alignment-Based Magnetometer
Wang, H., Wu, T., Xiao, W., Wang, H., Peng, X., & Guo, H. M. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.024033 · Cited by 27
Automatic coregistration of MRI and on-scalp MEG
Gu, W., Ru, X., Li, D., He, K., Cui, Y., Sheng, J., & Gao, J. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109181 · Cited by 26
A 4He vector zero-field optically pumped magnetometer operated in the Earth-field
Bertrand, F., Jäger, T., Boness, A., Fourcault, W., Gal, G. L., Palacios-Laloy, A., Paulet, J., & Léger, J. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062791 · Cited by 26
“As mentioned in the introduction of section III, the dynamic range of the electronics is the key point to enable the operation of null-field vector magnetometer in the Earth magnetic field without degradation of its intrinsic noise.”
BackgroundMethodSingle-domain Bose condensate magnetometer achieves energy resolution per bandwidth below ℏ
Palacios, S., Gomez, P., Coop, S., Zamora-Zamora, R., Mazzinghi, C., & Mitchell, M. W. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2115339119 · Cited by 27
Triaxial Vector Operation in Near-Zero Field of Atomic Magnetometer With Femtotesla Sensitivity
Lu, F., Lu, J., Li, B., Yan, Y., Zhang, S., Yin, K., Ye, M., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162282 · Cited by 27
OMMR: Co-registration toolbox of OPM-MEG and MRI
Cao, F., An, N., Xu, W., Wang, W., Li, W., Wang, C., Yang, Y., Xiang, M., Gao, Y., & Ning, X. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.984036 · Cited by 28
“The recent emergence of optically pumped magnetometers (OPM) (Kominis et al., 2003; Borna et al., 2017) based MEG (OPM-MEG) overcomes the limitations of conventional superconducting quantum interference devices (SQUID)”
BackgroundWang, K., Ma, D., Li, S., Gao, Y., & Sun, J. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114055 · Cited by 23
Gradient phase and amplitude errors in atomic magnetic gradiometers for biomagnetic imaging systems
Yuan, Z., Lin, S., Liu, Y., Tang, J., Long, T., & Zhai, Y. (2024) · iScience · doi:10.1016/j.isci.2024.109250 · Cited by 24
“19,20 More importantly, closer spacing between channels and smaller distances from subjects make OPMs more effective in terms of their better spatial-resolution and higher signal-to-noise ratio.”
BackgroundQuantum sensing with tunable superconducting qubits: optimization and speed-up
Danilin, S., Nugent, N., & Weides, M. P. (2024) · New Journal of Physics · doi:10.1088/1367-2630/ad49c5 · Cited by 41
Flow in porous metallic materials: A magnetic resonance imaging study
Xu, S., Harel, E., Michalak, D. J., Crawford, C. W., Budker, D., & Pines, A. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21532 · Cited by 26
Stern, L., & Levy, U. (2012) · Optics Express · doi:10.1364/oe.20.028082 · Cited by 23
Basic Principles of Magnetoencephalography
Hari, R., Parkkonen, L. T., & Hämäläinen, M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-397025-1.00012-9 · Cited by 23
Universal quantum control in zero-field nuclear magnetic resonance
Bian, J., Jiang, M., Cui, J., Liu, X., Chen, B., Ji, Y., Zhang, B., Blanchard, J. W., Peng, X., & Du, J. (2017) · Physical Review A · doi:10.1103/physreva.95.052342 · Cited by 24
Symmetry-breaking inelastic wave-mixing atomic magnetometry
Zhou, F. L., Zhu, C., Hagley, E. W., & Deng, L. (2017) · Science Advances · doi:10.1126/sciadv.1700422 · Cited by 27
Chiral light–matter interactions in hot vapor-cladded waveguides
Zektzer, R., Talker, E., Barash, Y., Mazurski, N., & Levy, U. (2018) · Optica · doi:10.1364/optica.6.000015 · Cited by 24
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.