A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 601–700 of 1,000
Experimental study of the CPT magnetometer worked on atomic energy level modulation
Liu, G., & Gu, S. (2010) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/43/3/035004 · Cited by 18
Detection of a weak magnetic field via cavity-enhanced Faraday rotation
Xia, K., Zhao, N., & Twamley, J. (2015) · Physical Review A · doi:10.1103/physreva.92.043409 · Cited by 18
Optical pumping of rubidium atoms frozen in solid argon
Kanagin, A. N., Regmi, S. K., Pathak, P., & Weinstein, J. D. (2013) · Physical Review A · doi:10.1103/physreva.88.063404 · Cited by 22
Magnetic microscopic imaging with an optically pumped magnetometer and flux guides
Kim, Y. J., Savukov, I., Huang, J., & Nath, P. (2017) · Applied Physics Letters · doi:10.1063/1.4975069 · Cited by 22
Interaction-based Quantum Metrology Showing Scaling Beyond the Heisenberg Limit
Napolitano, M., Koschorreck, M., Dubost, B., Behbood, N., Sewell, R. J., & Mitchell, M. W. (2012) · Research in Optical Sciences · doi:10.1364/qim.2012.qw1b.2 · Cited by 26
Advances in quantum magnetometry for geomagnetic research
Aleksandrov, E. B. (2010) · Physics-Uspekhi · doi:10.3367/ufne.0180.201005f.0509 · Cited by 20
Zhu, R., Zhang, Y., Du, P., Xuan, Y., Yang, F., Zhou, Y., Zhang, K., Li, X., Sun, S., Cheng, T., et al. (2025) · Measurement · doi:10.1016/j.measurement.2025.117099 · Cited by 18
Rusimova, K. R., Slavov, D. G., Pradaux, F., Collins, J. T., Gordeev, S. N., Carbery, D. R., Wadsworth, W. J., Mosley, P. J., & Valev, V. K. (2019) · Nature Communications · doi:10.1038/s41467-019-10158-4 · Cited by 17
Liu, C., Dong, H., & Sang, J. (2021) · Applied Physics Letters · doi:10.1063/5.0061364 · Cited by 17
Zhao, T., Zhai, Y., Liu, C., Xie, H.-T., Cao, Q., & Fang, X. (2022) · Optics Express · doi:10.1364/oe.463651 · Cited by 17
Bandwidth Expansion of Atomic Spin Gyroscope With Transient Response
Pei, H., Yu, W., Fan, W., Du, P., & Quan, W. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3186078 · Cited by 17
Xiang, J., Yu, X., Bonnette, S., Anand, M., Riehm, C. D., Schlink, B. R., Diekfuss, J. A., Myer, G. D., & Jiang, Y. (2023) · Brain Sciences · doi:10.3390/brainsci13040663 · Cited by 17
“Building on previous reports [34,35], this study’s purpose was to evaluate the methods that support the future translation of OPM-based MEG into more dynamic settings (e.”
MethodXie, X., Zhou, X., Zhao, F., Wang, W., & Sun, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3323996 · Cited by 18
“However, the sensitivity of the SERF magnetometer is limited by the absolute magnetic field [4], [5].”
BackgroundSubpicotesla Optomechanical Magnetometry
Xu, A., Li, Y., Li, X., Liu, B., & Liu, Y. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.153601 · Cited by 19
Searches for exotic spin-dependent interactions with spin sensors
Jiang, M., Su, H., Chen, Y., Jiao, M., Huang, Y., Wang, Y., Rong, X., Peng, X., & Du, J. (2024) · Reports on Progress in Physics · doi:10.1088/1361-6633/ad99e6 · Cited by 27
“Moreover, the K OPM has demonstrated a high sensitivity of 10 fT Hz − 1 / 2 in 3 He-K system [73, 75].”
InfluentialLevitated Ferromagnetic Magnetometer with Energy Resolution Well Below ℏ
Ahrens, F., Ji, W., Budker, D., Timberlake, C., Ulbricht, H., & Vinante, A. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.110801 · Cited by 18
Sevostianov, D. I., Yakovlev, V. P., Kozlov, A. N., Vasilev, V. V., Zibrov, S. A., & Velichansky, V. L. (2013) · Quantum Electronics · doi:10.1070/qe2013v043n07abeh015175 · Cited by 17
Optimized Condition for Buffer Gas in Optical-Pumped Magnetometer Operated at Room Temperature
Kawabata, R., Fukuda, K., & Kandori, A. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.082401 · Cited by 18
Laser spectroscopy of cold molecules
Borri, S., & Santambrogio, G. (2016) · Advances in Physics X · doi:10.1080/23746149.2016.1203732 · Cited by 22
Liu, J., Jing, D.-Y., Wang, L., Li, Y., Quan, W., Fang, J., & Liu, W. (2017) · Scientific Reports · doi:10.1038/s41598-017-06434-2 · Cited by 21
“Sen B B B B B B B ( ) (10) LS psn spn mag tech other 2 2 2 2 2 2 2”
Lock-in-detection in 87 Rb– 129 Xe/ 131 Xe atom spin gyroscopes
Lee, S., Yim, S. H., Kim, T. H., Kim, Z., & Shim, K.-M. (2020) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ab56db · Cited by 17
Trapped Rydberg ions: A new platform for quantum information processing
Mokhberi, A., Hennrich, M., & Schmidt‐Kaler, F. (2020) · Advances in atomic, molecular, and optical physics · doi:10.1016/bs.aamop.2020.04.004 · Cited by 30
“hotonic elds inside a cavity quantum electrodynamics (QED) setup (Brune et al., 1996; Raimond et al., 2001). For magnetometry, high sensitivity and spatial resolution were achieved in atomic vapours (Kominis et al., 2003; Wasilewski et al., 2010), ultracold atomic gases (Koschorreck et al., 2011; Vengalattore et al.,…”
Second-order effects in parametric-resonance magnetometers based on atomic alignment
Beato, F., & Palacios-Laloy, A. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-00083-7 · Cited by 17
Li, X., Zhai, Y., Fu, Y., Song, T., Liu, F., Cai, Q., & Quan, W. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abbc8a · Cited by 17
Magnetic induction imaging with a cold-atom radio frequency magnetometer
Fregosi, A., Gabbanini, C., Gozzini, S., Lenci, L., Marinelli, C., & Fioretti, A. (2020) · Applied Physics Letters · doi:10.1063/5.0020415 · Cited by 17
Optically pumped magnetometer with dynamic common mode magnetic field compensation
Wang, Y., Niu, Y., & Ye, C. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.113195 · Cited by 18
Oida, T., Ito, Y., Kamada, K., & Kobayashi, T. (2012) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.01.015 · Cited by 17
Review of atomic MEMS: driving technologies and challenges
Dong, H., Fang, J., Zhou, B., Qin, J., & Wan, S. (2010) · Microsystem Technologies · doi:10.1007/s00542-010-1089-6 · Cited by 19
Detection and localisation of magnetic objects
Barrell, Y., & Naus, H. W. L. (2007) · IET Science Measurement & Technology · doi:10.1049/iet-smt:20060129 · Cited by 17
A two-color pump probe atomic magnetometer for magnetoencephalography
Johnson, C., & Schwindt, P. D. D. (2010) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2010.5556310 · Cited by 22
“sensitivities of less than 1 fT/ √ Hz [4].”
BackgroundDetecting the propped fracture by injection of magnetic proppant during fracturing
Liu, J., Cao, S., Wu, X., & Yao, J. P. (2019) · Geophysics · doi:10.1190/geo2018-0221.1 · Cited by 17
Femtotesla all-optical dual-axis spin-exchange relaxation-free magnetometer
Li, X., Han, B., Liu, Z., Wang, Z., Sheng, J., Xiang, M., & Lu, J. (2024) · Applied Physics Letters · doi:10.1063/5.0216850 · Cited by 16
Atom–Photon Interactions in Atomic Cladded Waveguides: Bridging Atomic and Telecom Technologies
Zektzer, R., Talker, E., Barash, Y., Mazurski, N., Stern, L., & Levy, U. (2021) · ACS Photonics · doi:10.1021/acsphotonics.0c01895 · Cited by 17
Microfabricated Optically-Pumped Magnetometers
Jiménez-Martínez, R., & Knappe, S. A. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_17 · Cited by 28
Quantum-assisted distortion-free audio signal sensing
Zhang, C., Dasari, D. B. R., Widmann, M., Meinel, J., Vorobyov, V., Kapitanova, P. V., Nenasheva, E. A., Nakamura, K. T., Sumiya, H., Onoda, S., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-32150-1 · Cited by 20
Liu, Y., Gao, H., Ma, L., Quan, J., Fan, W., Xu, X., Fu, Y., Duan, L., & Quan, W. (2022) · Materials · doi:10.3390/ma15228267 · Cited by 17
Zhang, S., Zhou, Y., Chai, Z., Liu, Q., Yin, K., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3232658 · Cited by 17
“bility of detecting extremely weak magnetic on the order of femtotesla and even subfemtotesla [1], [2], [3], [4], [5].”
BackgroundSingle-Beam Double-Pass Miniaturized Atomic Magnetometer for Biomagnetic Imaging Systems
Li, X., Guo, Z., Yang, R., & Feng, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3271201 · Cited by 17
“3271201 comparable to those of SQUIDs [7], [8].”
BackgroundBenchtop Magnetic Shielding for Benchmarking Atomic Magnetometers
Hobson, P. J., Holmes, N., Patel, P., Styles, B., Chalmers, J., Morley, C., Davis, A., Packer, M., Smith, T. X., Raudonyte, S., et al. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3293540 · Cited by 19
“cally pumped magnetometers (OPMs) [7], [8] have diverse”
BackgroundSun, B., Ma, D., Bai, G., Zeng, M., Cheng, T., Ma, Y., Xu, X., Quan, W., Han, B., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113419 · Cited by 19
Interspecies spin-noise correlations in hot atomic vapors
Mouloudakis, K., Vouzinas, F., Margaritakis, A., Koutsimpela, A., Mouloudakis, G., Koutrouli, V., Skotiniotis, M., Tsironis, G. P., Loulakis, M., Mitchell, M. W., et al. (2023) · Physical Review A · doi:10.1103/physreva.108.052822 · Cited by 19
“Comprehension of more subtle aspects of SE [54–56] led to the development of spin-exchange relaxation-free (SERF) magnetometers [57–59], SE optically pumped hyperpolarized noble gases utilized in medical applications [60–62], and hydrogen magnetometry [63–65].”
Self-citationPerspective: nanoscale electric sensing and imaging based on quantum sensors
Zhang, S., Bian, K., & Jiang, Y. X. (2023) · Quantum Frontiers · doi:10.1007/s44214-023-00045-x · Cited by 19
“Historical examples of quantum sensors include magnetometers such as SQUID [22, 23], atomic vapors [24], and atomic clocks [25].”
Garcia, N. C., Yu, D., Yao, L., & Xu, S. (2010) · Optics Letters · doi:10.1364/ol.35.000661 · Cited by 17
Multi-flux-transformer MRI detection with an atomic magnetometer
Savukov, I., & Karaulanov, T. S. (2014) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2014.10.009 · Cited by 16
“AMs have demonstrated femtotesla sensitivity [6,7], similar to SQUIDs, and low-cost radio-frequency (RF) AM sensors have been designed and tested [8].”
BackgroundA self-sustaining atomic magnetometer with τ−1 averaging property
Xu, C., Wang, S., Feng, Y. Y., Zhao, L., & Wang, L. J. (2016) · Scientific Reports · doi:10.1038/srep28169 · Cited by 16
A rubidium Mx-magnetometer for measurements on solid state spins
Arnold, D., Siegel, S., Grisanti, E., Wrachtrup, J., & Gerhardt, I. (2017) · Review of Scientific Instruments · doi:10.1063/1.4974845 · Cited by 16
Zou, S., Zhang, H., Chen, X., Wang, Z., Quan, W., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2873665 · Cited by 16
“OPTICALLY pumped alkali magnetometer that operates in non-cryogenic environment has the ultra-high sensitivity and spatial resolution rivaling the performance of superconducting quantum interference magnetometer [1]–[3].”
BackgroundHironaga, N., Takei, Y., Mitsudo, T., Kimura, T., & Hirano, Y. (2020) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2020.00863 · Cited by 20
“Drastic changes have occurred since the development of a new spin-exchange relaxation-free condition, which has led to sensitivities up to the femtotesla range (74).”
BackgroundCPT Magnetometer with Atomic Energy Level Modulation
Guo-Bin, L., Du, R., Chao-Yang, L., & Gu, S. (2008) · Chinese Physics Letters · doi:10.1088/0256-307x/25/2/033 · Cited by 16
Oida, T., Tsuchida, M., & Kobayashi, T. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2199469 · Cited by 16
Nuclear magnetic resonance gyroscopes
Donley, E. A., & Kitching, J. E. (2013) · Cambridge University Press eBooks · doi:10.1017/cbo9780511846380.020 · Cited by 16
Lindseth, B. J., Schwindt, P. D. D., Kitching, J. E., Fischer, D., & Shusterman, V. (2007) · Computers in cardiology · doi:10.1109/cic.2007.4745517 · Cited by 17
Optical spectroscopy of a microsized Rb vapor sample in magnetic fields up to 58 T
Ciampini, D., Battesti, R., Rizzo, C., & Arimondo, E. (2017) · Physical Review A · doi:10.1103/physreva.96.052504 · Cited by 15
Sjolander, T. F., Blanchard, J. W., Budker, D., & Pines, A. (2020) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2020.106781 · Cited by 16
“Spin-Exchange Relaxation-Free (SERF) regime [35], configured for use as an NMR spectrometer [4].”
MethodCollision-induced spin depolarization of alkali-metal atoms in cold He3 gas
Tscherbul, T. V., Zhang, P., Sadeghpour, H. R., Dalgarno, A., Brahms, N., Au, Y. S., & Doyle, J. M. (2008) · Physical Review A · doi:10.1103/physreva.78.060703 · Cited by 16
Differential atomic magnetometry based on a diverging laser beam
Hodby, E., Donley, E. A., & Kitching, J. E. (2007) · Applied Physics Letters · doi:10.1063/1.2753763 · Cited by 17
Atomic Magnetometry Using a Metasurface Polarizing Beamsplitter in Silicon-on-Sapphire
Yang, X., Mukherjee, P., Kim, M., Mei, H., Fang, C., Choi, S., Tong, Y., Perlowski, S., Czaplewski, D. A., Dibos, A., et al. (2024) · ACS Photonics · doi:10.1021/acsphotonics.4c00744 · Cited by 15
“In combination with advances in miniaturized atomic vapor cell fabrication [2–6], atomic magnetometers are suitable for a host of field applications including biomagnetic imaging in ambient conditions [9–11], navigation and positioning [12–14], and magnetic anomaly detection [15].”
BackgroundQuantum Sensing with Spin Defects Beyond Diamond
Roberts, H. C., Abudayyeh, H. A., Li, X., & Li, X. (2025) · ACS Nano · doi:10.1021/acsnano.5c00802 · Cited by 29
High bandwidth laser frequency locking for wideband noise suppression
Jing, M., Zhang, P., Yuan, S., Zhang, L., Xiao, L., & Jia, S. (2021) · Optics Express · doi:10.1364/oe.419832 · Cited by 16
Laser Heating Method for an Alkali Metal Atomic Cell with Heat Transfer Enhancement
Li, Y., Zhou, G., Tian, S., Liu, X., Dong, X., & Gao, X. (2023) · Photonics · doi:10.3390/photonics10060637 · Cited by 15
“There are three common heating methods: electric heating [12–16], flow hot air heating [17,18], and laser heating [19–25].”
Xu, Y., Chai, Z., Sun, J., Bai, D., Huang, K., Tian, Z., Cui, Z., & Pei, Y. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202300084 · Cited by 15
Wang, K., Ma, D., Li, S., Ma, Y., Gao, Y., Dou, Y., & Sun, J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3291361 · Cited by 15
“magnetic measurement sensitivity specifications [8], [9].”
All-Optical Nonzero-Field Vector Magnetic Sensor for Magnetoencephalography
Petrenko, M. V., Pazgalev, A. S., & Vershovskii, A. K. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024001 · Cited by 15
Ultra-high consistency multichannel SERF atomic magnetometer based on diffractive optics
Li, J., Liu, Y., Chai, Z., Cao, Q., Li, R., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114868 · Cited by 16
Xu, X., Zhao, Z., Liu, W., Ye, F., Zhu, T., & Li, X. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115431 · Cited by 15
Spin noise spectroscopy of an alignment-based atomic magnetometer
Koźbiał, M., Elson, L., Rushton, L. M., Akbar, A., Meraki, A., Jensen, K., & Kołodyński, J. (2024) · Physical Review A · doi:10.1103/physreva.110.013125 · Cited by 17
“Optically pumped magnetometers (OPMs) [1, 2] based on e.g. caesium, rubidium or potassium atomic vapour, or helium gas can have high sensitivity in the fT/ √ Hz range [3].”
BackgroundSingle‐Beam Vector Atomic Magnetometer with High Dynamic Range Based on Magnetic Field Modulation
Chen, J., Jiang, L., Zhao, X. H., Liu, J., Chai, Y., Tian, M., & Lu, Z. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202400289 · Cited by 15
Four-channel miniaturized SERF magnetometer with spatial inhomogeneous atomic polarization
Liang, Z., Zhang, Y., Long, T., Li, B., Hu, J., Zhou, P., Liu, L., Hu, G., Ye, M., & Wang, Y. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.112013 · Cited by 16
Highly responsive ac scalar atomic magnetometer with long relaxation time
Terao, A., Ban, K., Ichihara, S., Mizutani, N., & Kobayashi, T. (2013) · Physical Review A · doi:10.1103/physreva.88.063413 · Cited by 15
Pressure broadening and shift of K D1 and D2 lines in the presence of 3He and 21Ne
Li, R., Li, Y., Jiang, L., Quan, W., Ding, M., & Fang, J. (2016) · The European Physical Journal D · doi:10.1140/epjd/e2016-60734-4 · Cited by 15
Optically Pumped Magnetometers for Biomagnetic Measurements
Romalis, M. V. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_1 · Cited by 19
Self-citationAnalysis and Suppression of Thermal Magnetic Noise of Ferrite in the SERF Co-Magnetometer
Pang, H., Liu, F., Fan, W., Wu, J., Yuan, Q., Wu, Z., & Quan, W. (2022) · Materials · doi:10.3390/ma15196971 · Cited by 15
Ensemble spin fabrication and manipulation of NV centres for magnetic sensing in diamond
Mu, J., Qu, Z., Ma, Z., Zhang, S., Shi, Y., Gao, J., Zhang, X., Cao, H., Qin, L., Liu, J., et al. (2017) · Sensor Review · doi:10.1108/sr-09-2016-0163 · Cited by 15
Zhang, G., Huang, S.-J., & Lin, Q. (2018) · AIP Advances · doi:10.1063/1.5066604 · Cited by 16
Spin-exchange collisions in hot vapors creating and sustaining bipartite entanglement
Mouloudakis, K., & Kominis, I. K. (2021) · Physical Review A · doi:10.1103/physreva.103.l010401 · Cited by 16
Self-citationHatakeyama, A., Wilde, M., & Fukutani, K. (2006) · e-Journal of Surface Science and Nanotechnology · doi:10.1380/ejssnt.2006.63 · Cited by 15
Breakdown of Angular Momentum Selection Rules in High Pressure Optical Pumping Experiments
Lancor, B., Babcock, E., Wyllie, R., & Walker, T. G. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.083003 · Cited by 15
Chip Scale Atomic Magnetometers
Schwindt, P. D. D., Lindseth, B. J., Knappe, S. A., Shah, V., Liew, L., Moreland, J., Hollberg, L. W., & Kitching, J. E. (2006) · IEEE International Magnetics Conference · doi:10.1109/intmag.2006.376110 · Cited by 15
Tao, R., Zhang, S., Zhang, R., Shen, C., Ma, J., Cui, J., Chen, Y., Wang, B., Li, H., Xie, X., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-90615-x · Cited by 14
“Recent advancements, such as unshielded MCG systems 14 , high-sensitive magnetic gradiometers 15 , and room-temperature magnetic sensors 16 , have enabled the detection of extremely weak cardiac magnetic signal down to the pico-Tesla range in clinical routine.”
Zhou, Z., Zhang, H., Huang, R., He, F., Xu, D. Y., Yan, X., & Li, L. (2025) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-025-01492-4 · Cited by 14
Yan, Y., Yuan, J., Wang, L., Xiao, L., & Jia, S. (2021) · Optics Communications · doi:10.1016/j.optcom.2021.127855 · Cited by 14
Review of noble-gas spin amplification via the spin-exchange collisions
Su, H., Jiang, M., & Peng, X. (2022) · Science China Information Sciences · doi:10.1007/s11432-022-3550-1 · Cited by 16
Ultra-low noise, bi-polar, programmable current sources
Mrozowski, M. S., Chalmers, I. C., Ingleby, S. J., Griffin, P. F., & Riis, E. (2023) · Review of Scientific Instruments · doi:10.1063/5.0114760 · Cited by 20
Ding, Z., Li, L., Huang, Z., & Han, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3267356 · Cited by 15
“[7] first proposed the OPM, whose sensitivity reaches 0.”
BackgroundMethodLong, T., Song, X., Han, B., Suo, Y., & Jia, L. (2023) · Metrologia · doi:10.1088/1681-7575/accd74 · Cited by 17
Suppression of thermal coupling noise in the SERF atomic co-magnetometer
Ruan, J., Duan, L., Fu, Y., Yang, L., Fan, W., Zhou, X., & Quan, W. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107007 · Cited by 14
High-sensitivity atomic magnetometer realized by weak-value-amplification effect
Lin, S., Tang, J., Yuan, Z., Huang, B., Wang, Y., & Zhai, Y. (2023) · Applied Physics Letters · doi:10.1063/5.0168990 · Cited by 17
Dong, H., Ye, H., Hu, M., & Ma, Z. (2023) · Micromachines · doi:10.3390/mi15010059 · Cited by 15
“Using only one vapor cell has the benefit that the alkali atom density and buffer gas pressure will be kept the same all the time [41,42]. same all the time [41,42].”
BackgroundSensitivity of a vector atomic magnetometer based on electromagnetically induced transparency
Maldonado, M. A. G., Rollins, O., Toyryla, A., McKelvy, J., Matsko, A. B., Fan, I., Li, Y., Wang, Y.-J., Kitching, J. E., Novikova, I. V., et al. (2024) · Optics Express · doi:10.1364/oe.529276 · Cited by 19
Mamishin, Y., Ito, Y., & Kobayashi, T. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2659649 · Cited by 15
“Recently, optically pumped atomic magnetometers (OPAMs) [3]–[5], based on spin polarization of alkali metal atoms and Faraday rotation, have attracted a”
BackgroundAvoiding the impact of the heater-induced longitudinal field on atomic magnetometers
Jiang, Q., Luo, H., Zhan, X., Zhang, Y., Yang, K., & Wang, Z. (2018) · Journal of Applied Physics · doi:10.1063/1.5054050 · Cited by 15
Fast and robust optically pumped cesium magnetometer
Lebedev, V., Hartwig, S., & Middelmann, T. (2019) · Advanced Optical Technologies · doi:10.1515/aot-2020-0024 · Cited by 14
Comparison Between Conventional SQUID Based and Novel OPM Based Measuring Systems in MEG
Marhl, U., Jodko-Władzińska, A., Brühl, R., Sander, T. H., & Jazbinšek, V. (2020) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-64610-3_30 · Cited by 15
Single-Beam Miniaturized Atomic Magnetometer With Square-Wave Modulation for Magnetoencephalography
Ding, Z., Han, B., & Tang, J. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3043947 · Cited by 15
Brazhnikov, D. V., Vishnyakov, V. I., Ignatovich, S. M., Mesenzova, I. S., Andreeva, C., & Goncharov, A. (2021) · Applied Physics Letters · doi:10.1063/5.0059019 · Cited by 14
Ultra-sensitive all-optical comagnetometer with laser heating
Zhao, T., Liu, Y., Wei, K., Xie, H.-T., Mu, T., Fang, X., Xu, Z., & Zhai, Y. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac49b5 · Cited by 14
Evaluation of optical parameters for a microminiature Rb vapor cell in a dual-beam SERF magnetometer
Wang, Y., Shi, T., Zhou, W., Tang, J., Zhou, B., Jin, G., Han, B., & Zou, S. (2022) · Optics Express · doi:10.1364/oe.458827 · Cited by 16
Suo, Y., Song, X., Jia, L., Long, T., Ye, M., & Zhou, B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3198502 · Cited by 14
An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer
Su, S., Xu, Z.-Y., He, X., Yin, C., Kong, M., Zhang, X., Ruan, Y., Li, K., & Lin, Q. (2023) · Sensors · doi:10.3390/s23063148 · Cited by 16
“Among them, AMs operated in the condition of the spin-exchange relaxation-free (SERF) regime enable the highest sensitivity [7], comparable to SQUID magnetometers.”
BackgroundA full optically operated magnetometer array: An experimental study
IJsselsteijn, R. P. J., Kielpinski, M., Woetzel, S., Scholtes, T., Kessler, E., Stolz, R., Schultze, V., & Meyer, H. ‐. (2012) · Review of Scientific Instruments · doi:10.1063/1.4766961 · Cited by 13
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.