A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 501–600 of 1,000
Yang, H., Zhang, K., Wang, Y., & Zhao, N. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab541a · Cited by 23
Appelt, S., Glöggler, S., Häsing, F. W., Sieling, U., Gordji-Nejad, A., & Blümich, B. (2009) · Chemical Physics Letters · doi:10.1016/j.cplett.2009.11.066 · Cited by 23
Yu, M., Chen, Y., Wang, Y., Han, X., Luo, G., Zhao, L., Wang, Y., Ma, Y., Lu, S., Yang, P., et al. (2023) · Engineering · doi:10.1016/j.eng.2023.08.016 · Cited by 24
New Classes of Magnetic Noise Self-Compensation Effects in Atomic Comagnetometer
Qin, Y., Shao, Z., Hong, T., Wang, Y., Jiang, M., & Peng, X. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023202 · Cited by 25
Shukla, R. K., Chotorlishvili, L., Mishra, S. K., & Iemini, F. (2025) · Physical review. B./Physical review. B · doi:10.1103/physrevb.111.024315 · Cited by 32
High-voltage current sensing with nitrogen-vacancy centers in diamond
Zhang, S.-C., Zhao, L., Qiu, R.-J., Geng, J., Tian, T., Zhao, B., Liu, Y., Shan, L., Chen, X.-D., Guo, G., et al. (2025) · APL Photonics · doi:10.1063/5.0256419 · Cited by 27
Intrinsic relaxation rates of polarized Cs vapor in miniaturized cells
Scholtes, T., Woetzel, S., IJsselsteijn, R. P. J., Schultze, V., & Meyer, H. (2014) · Applied Physics B · doi:10.1007/s00340-014-5824-z · Cited by 25
A magnetic source imaging camera
Dolgovskiy, V., Fescenko, I., Sekiguchi, N., Colombo, S., Lebedev, V., Zhang, J., & Weis, A. (2016) · Applied Physics Letters · doi:10.1063/1.4958700 · Cited by 22
Effect of gaps on magnetic noise of cylindrical ferrite shield
Lu, J., Sun, C., Ma, D., Yang, K., Zhao, J., Han, B., Quan, W., Zhang, N., & Ding, M. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/abf169 · Cited by 22
Improved spatio-temporal measurements of visually evoked fields using optically-pumped magnetometers
Gialopsou, A., Abel, C., James, T. M., Coussens, T., Bason, M. G., Puddy, R. K., Lorenzo, F. D., Rolfs, K., Voigt, J., Sander, T. H., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-01854-7 · Cited by 24
Quantum Sensing of Thermoelectric Power in Low‐Dimensional Materials
Zhao, M., Kim, D., Lee, Y. H., Yang, H., & Cho, S. (2022) · Advanced Materials · doi:10.1002/adma.202106871 · Cited by 26
Li, L., Tang, J., Zhao, B., Li, C., Zhou, B., & Zhai, Y. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac9cea · Cited by 23
Search for exotic parity-violation interactions with quantum spin amplifiers
Wang, Y., Huang, Y., Guo, C., Jiang, M., Kang, X., Su, H., Qin, Y., Ji, W., Hu, D., Peng, X., et al. (2023) · Science Advances · doi:10.1126/sciadv.ade0353 · Cited by 26
“Moreover, the use of gradient detection can further eliminate the magnetic noise by nearly two orders of magnitude without suppressing the exponential distance – dependent POSS interaction ( 34 ).”
Optical pumping enhancement of a free-induction-decay magnetometer
Hunter, D., Mrozowski, M. S., McWilliam, A., Ingleby, S. J., Dyer, T., Griffin, P. F., & Riis, E. (2023) · Journal of the Optical Society of America B · doi:10.1364/josab.501086 · Cited by 27
“There have been non-electrical heating methods adopted in the past such as optical heating [30] and hot air systems [31], although these techniques require a great deal of power and are often restricted to a laboratory setting.”
BackgroundWang, L., Shi, M., Le, Y., Zhang, X., Yang, J., Yuan, S., & Ma, Y. (2024) · Measurement · doi:10.1016/j.measurement.2024.114276 · Cited by 22
Magnetic tensor gradiometry using Ramsey interferometry of spinor condensates
Wood, A. A., Bennie, L. M., Duong, A., Jasperse, M., Turner, L. D., & Anderson, R. P. (2015) · Physical Review A · doi:10.1103/physreva.92.053604 · Cited by 23
A Highly Sensitive Magnetometer Based on the Villari Effect
Wang, H. B., & Feng, Z. H. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2220559 · Cited by 22
“The biggest breakthrough came in 2003 with the invention of the spin-exchange relaxation-free atomic magnetometer [8], which achieved a sensitivity of 0.”
BackgroundIto, Y., Sato, D., Kamada, K., & Kobayashi, T. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2329856 · Cited by 25
Spin Exchange Relaxation Free (SERF) Magnetometers
Savukov, I. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_15 · Cited by 35
Quan, W., Wei, K., & Li, H. (2017) · Optics Express · doi:10.1364/oe.25.008470 · Cited by 20
Estimating a fluctuating magnetic field with a continuously monitored atomic ensemble
Zhang, C., & Mølmer, K. (2020) · Physical Review A · doi:10.1103/physreva.102.063716 · Cited by 24
100 pT/cm single-point MEMS magnetic gradiometer from a commercial accelerometer
Javor, J., Stange, A., Pollock, C., Fuhr, N. E., & Bishop, D. J. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0173-z · Cited by 28
Hafiz, M. A., Maurice, V. N., Chutani, R., Passilly, N., Gorecki, C., Guérandel, S., de Clercq, E., & Boudot, R. (2015) · Journal of Applied Physics · doi:10.1063/1.4919841 · Cited by 22
Estimation of fluctuating magnetic fields by an atomic magnetometer
Petersen, V., & Mølmer, K. (2006) · Physical Review A · doi:10.1103/physreva.74.043802 · Cited by 24
Noh, H., & Moon, H. S. (2010) · Physical Review A · doi:10.1103/physreva.82.033407 · Cited by 21
Detection of magnetic nanomaterials in molecular imaging and diagnosis applications
Li, Y., & Xu, S. (2014) · Nanotechnology Reviews · doi:10.1515/ntrev-2013-0044 · Cited by 25
Gao, Y., Ma, D., Li, M., Zhang, M., Chen, Y., Han, C., Wang, Y., Fang, X., Dou, Y., & Wang, K. (2024) · Measurement · doi:10.1016/j.measurement.2024.115971 · Cited by 21
Optically pumped vector magnetometer using a strong bias magnetic field
Schönau, T., Scholtes, T., Wittkämper, F., Sekels, A., Hiebel, S., Oelsner, G., & Stolz, R. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.024006 · Cited by 27
Optically pumped rubidium atomic magnetometer with elliptically polarized light
Ding, Z., Yuan, J., Wang, Z., Lu, G., & Luo, H. (2016) · Optik · doi:10.1016/j.ijleo.2016.02.071 · Cited by 21
Ji, Y., Shang, J., Gan, Q., Wu, L., & Wong, C. (2018) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2018.2868313 · Cited by 23
“Chip-scale SERF atomic magnetometers using a single laser beam were investigated for the characterization of polarization lifetime and sensitivity [18], [19], as shown in Fig.”
MethodSuppression Method of AC-Stark Shift in SERF Atomic Magnetometer
Li, Y., Ding, M., Liu, X., Cai, H., Zhao, J., & Fang, J. (2018) · IEEE photonics journal · doi:10.1109/jphot.2018.2872026 · Cited by 27
“The polarization of the probe light is probed using Faraday modulation technique [14] with 3.”
MethodOvercoming synthesizer phase noise in quantum sensing
Long, G., Feng, G., & Sprenger, P. (2019) · Quantum Engineering · doi:10.1002/que2.27 · Cited by 20
Indium Tin Oxide Non-Magnetic Heating Film for Miniaturized SERF Gradient Magnetometer
Liu, Z., Zhang, C., Yuan, H., Yin, K., Yang, Y., Yan, Y., Wang, Y., Zhou, B., Ning, X., & Han, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3076133 · Cited by 22
Lee, D. Y., Lee, S., Kim, M. M., & Yim, S. H. (2021) · Physical Review A · doi:10.1103/physreva.104.042819 · Cited by 21
Lu, F., Li, B., Lu, J., Ye, M., Ning, X., & Han, B. (2022) · Optics Letters · doi:10.1364/ol.465832 · Cited by 21
Femtotesla 4 He magnetometer with a multipass cell
Liu, Y., Peng, X., Wang, H., Wang, B., Yi, K., Sheng, D., & Guo, H. M. (2022) · Optics Letters · doi:10.1364/ol.471557 · Cited by 24
Correlating the microstructure of Mn–Zn ferrite with magnetic noise for magnetic shield applications
Sun, B., Ma, D., Bai, G., Lu, J., Yang, K., Wang, K., Xu, X., Zhai, Y., Quan, W., & Han, B. (2022) · Ceramics International · doi:10.1016/j.ceramint.2022.12.045 · Cited by 23
Frequency Matching in Light-Storage Spectroscopy of Atomic Raman Transitions
Karpa, L., Nikoghosyan, G., Vewinger, F., Fleischhauer, M., & Weitz, M. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.093601 · Cited by 22
Three axis vector atomic magnetometer utilizing polarimetric technique
Pradhan, S. (2016) · Review of Scientific Instruments · doi:10.1063/1.4962021 · Cited by 21
Entanglement-Enhanced Phase Estimation without Prior Phase Information
Colangelo, G., Ciurana, F. M., Puentes, G., Mitchell, M. W., & Sewell, R. J. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.233603 · Cited by 26
“Such states are attractive for high-bandwidth and high-sensitivity optical magnetometers [8,50] and other atomic sensing applications employing nondestructive spin detection [16,26,51].”
BackgroundJia, F.-D., Yu, Y., Liu, X., Zhang, X., Zhang, L., Wang, F., Mei, J., Zhang, J., Xie, F., & Zhong, Z. (2020) · Applied Optics · doi:10.1364/ao.401945 · Cited by 22
A nanowaveguide platform for collective atom-light interaction
Meng, Y., Lee, J., Dagenais, M., & Rolston, S. L. (2015) · Applied Physics Letters · doi:10.1063/1.4929947 · Cited by 21
Moon, H. S., & Noh, H. (2011) · Physical Review A · doi:10.1103/physreva.84.033821 · Cited by 21
Magnetocardiography with GMR-based sensors
Pannetier-Lecoeur, M., Polovy, H., Sergeeva-Chollet, N., Cannies, G., Fermon, C., & Parkkonen, L. T. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/303/1/012054 · Cited by 21
Improving the sensitivity of optically pumped magnetometers by hyperfine repumping
Schultze, V., Scholtes, T., IJsselsteijn, R. P. J., & Meyer, H. ‐. (2015) · Journal of the Optical Society of America B · doi:10.1364/josab.32.000730 · Cited by 20
Kim, K., Lee, W., Kim, I.-S., & Moon, H. S. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.890610 · Cited by 23
“metal vapor were reported to have a comparable sensitivity with SQUID sensors [4].”
BackgroundQuan, J., Pang, H., Ma, L., Xia, H., Xu, Y., Fan, W., Wu, Z., & Quan, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3657545 · Cited by 20
Progress and applications of quantum precision measurement based on SERF effect
Zhai, Y., Yue, Z., Li, L., & Liu, Y. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.969129 · Cited by 23
“SERF magnetometer, which made it possible to study the cerebral cortex module non-invasively [22].”
BackgroundMethodMa, N., Duan, L., Ma, D., Lu, J., Xing, B., Li, J., & Han, B. (2022) · Optics Express · doi:10.1364/oe.474777 · Cited by 20
Markov Noise in Atomic Spin Gyroscopes: Analysis and Suppression Based on Allan Deviation
Pei, H., Fan, W., Du, P., Zhang, K., Yuan, L., & Quan, W. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3246473 · Cited by 20
“of magnetic measurement sensitivity [5].”
Li, L., Tang, J., Zhao, B., Cao, L., Zhang, Y., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113161 · Cited by 22
Atomic Comagnetometer Gyroscopes for Inertial Navigation Systems: A Review
Karabinaoğlu, M. S., Çakır, B., & Başoğlu, M. E. (2024) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.55730/1300-0632.4070 · Cited by 22
“Recent advances in quantum sensing and quantum sensors are quite remarkable [11] such as in time-frequency [22], magnetic and electric fields [23] rotation [13, 24], and temperature [25] sensing.”
BackgroundA High-Sensitivity Tunable Two-Beam Fiber-Coupled High-Density Magnetometer with Laser Heating
Savukov, I., & Boshier, M. G. (2016) · Sensors · doi:10.3390/s16101691 · Cited by 22
“Atomic magnetometers (AMs) operating in the spin-exchange-relaxation-free (SERF) regime have demonstrated similar sensitivity to SQUIDs [1,2] and are a promising cryogen-free alternative to SQUIDs for many applications, such as MEG [3–7], magneto-cardiography (MCG) [8,9], ultra-low-field NMR [10–12], and MRI [13,14].”
MethodInfluentialSensitive and stable vector magnetometer for operation in zero and finite fields
Bison, G., Бондар, В. М., Schmidt-Wellenburg, P., Schnabel, A., & Voigt, J. (2018) · Optics Express · doi:10.1364/oe.26.017350 · Cited by 20
Zhao, J., Liu, G., Lu, J., Yang, K., Ma, D., Xing, B., Han, B., & Ding, M. (2019) · IEEE Access · doi:10.1109/access.2019.2954103 · Cited by 22
“To achieve a very weak magnetic field environment, passive magnetic shield is adopted to reduce the spatial magnetic field to the order of 1 nT [9], [10].”
MethodSignal-enhanced real-time magnetic resonance of enzymatic reactions at millitesla fields
Korchak, S. E., Jagtap, A. P., & Glöggler, S. (2020) · Chemical Science · doi:10.1039/d0sc04884d · Cited by 21
Zhao, W., Tao, X., Ye, C., & Tao, Y. (2022) · Sensors · doi:10.3390/s22031021 · Cited by 21
“The quantum state of the atoms is very sensitive to the external magnetic field, which can be probed to infer the external magnetic field [5,6].”
BackgroundSearch for plant biomagnetism with a sensitive atomic magnetometer
Corsini, E., Acosta, V., Baddour, N., Higbie, J., Lester, B., Licht, P., Patton, B., Prouty, M., & Budker, D. (2011) · Journal of Applied Physics · doi:10.1063/1.3560920 · Cited by 23
Gusarov, A., Levron, D., Baranga, A. B.-A., Paperno, E., & Shuker, R. (2011) · Journal of Applied Physics · doi:10.1063/1.3536673 · Cited by 20
Magnetic Field Sensors in Medical Diagnostics
Ichkitidze, L. P., Bazaev, N. A., Telyshev, D. V., Preobrazhensky, R. Y., & Ml, G. (2015) · Biomedical Engineering · doi:10.1007/s10527-015-9475-0 · Cited by 20
Spin Hyperpolarization in Modern Magnetic ResonancePreprint
Eills, J., Budker, D., Cavagnero, S., Chekmenev, E. Y., Elliott, S. J., Jannin, S., Lesage, A., Matysik, J., Meersmann, T., Prisner, T. F., et al. (2022) · ChemRxiv · doi:10.26434/chemrxiv-2022-p7c9r · Cited by 20
Li, J., Sun, S., Li, X., Feng, Y., Zhang, Y., Huang, X., Du, P., Zhang, J., Chen, L., Sanz, Á. S., et al. (2024) · ACS Photonics · doi:10.1021/acsphotonics.4c01694 · Cited by 19
Liao, S.-H., Chen, M.-J., Yang, H.-C., Lee, S.-Y., Chen, H.-H., Horng, H. E., & Yang, S. (2010) · Review of Scientific Instruments · doi:10.1063/1.3498895 · Cited by 19
Optimization of the alkali-metal density ratio in a hybrid optical pumping atomic magnetometer
Li, Y., Liu, X.-J., Cai, H., Ding, M., & Fang, J.-C. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaefe2 · Cited by 18
Chip-Scale Ultra-Low Field Atomic Magnetometer Based on Coherent Population Trapping
Hong, H.-G., Park, S. E., Lee, S.-B., Heo, M.-S., Park, J., Kim, T. H., Kim, H. Y., & Kwon, T. Y. (2021) · Sensors · doi:10.3390/s21041517 · Cited by 19
“The sensitivity surpassing fT/Hz1/2 level has been reported in a spin-exchange-free regime (SERF) [2], and the absence of cryogenic cooling makes it favorable for a wide range of applications, such as tracking of magnetic objects [3,4], space exploration [5], and medical signal detection [6–8].”
BackgroundQuantum sensing of the electron electric dipole moment using ultracold entangled Fr atoms
Aoki, T., Sreekantham, R., Sahoo, B. K., Arora, B., Kastberg, A., Sato, T., Ikeda, H., Okamoto, N., Torii, Y., Hayamizu, T., et al. (2021) · Quantum Science and Technology · doi:10.1088/2058-9565/ac1b6a · Cited by 22
Liu, Y., Fan, W., Fu, Y., Pang, H., Pei, H., & Quan, W. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3169541 · Cited by 25
Triaxial closed-loop measurement based on a single-beam zero-field optically pumped magnetometer
Wang, K., Zhang, K., Zhou, B., Lu, F., Zhang, S., Yan, Y., Wang, W., & Lu, J. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.1059487 · Cited by 20
“For zero-field OPMs, the frequency response of the inputoutput relationship could be described as [1, 9].”
BackgroundMethodUltrasensitive Optical Rotation Detection With Closed-Loop Suppression of Spin Polarization Error
Heng, X., Wei, K., Zhao, T., Xu, Z., Cao, Q., Huang, X., Zhai, Y., Ye, M., & Quan, W. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3237208 · Cited by 19
“Operating the K-Rb-21 Ne comagnetometer system in SERF regime, the calibration factor is obtained by matching the response of the magnetometer in occasions of different calibrating fields with normalized frequency-response function [42].”
MethodSignal-enhanced spin-exchange relaxation-free atomic magnetometer
Li, C., Tang, J., Zhang, Y., Yuan, Z., Li, J., Zhai, Y., & Liu, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114247 · Cited by 22
Zero-field optical magnetometer based on spin alignment
Meraki, A., Elson, L., Ho, N. J., Akbar, A., Koźbiał, M., Kołodyński, J., & Jensen, K. (2023) · Physical Review A · doi:10.1103/physreva.108.062610 · Cited by 20
Spin-exchange narrowing of the atomic ground-state resonances
Chałupczak, W., Josephs-Franks, P., Patton, B., & Pustelny, S. (2014) · Physical Review A · doi:10.1103/physreva.90.042509 · Cited by 19
Magnetometry using fluorescence of sodium vapor
Fan, T., Zhang, L., Yang, X., Cui, S., Zhou, T., & Feng, Y. (2017) · Optics Letters · doi:10.1364/ol.43.000001 · Cited by 19
Characterization of polarimetric based three axis atomic magnetometer
Pradhan, S., & Behera, R. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.03.004 · Cited by 20
Electromagnetic fields induced by an electric charge near a Weyl semimetal
Martín-Ruiz, A., Cambiaso, M., & Urrutia, L. F. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.99.155142 · Cited by 26
Harada, S., Sasada, I., & Feng, H. (2015) · Electronics and Communications in Japan · doi:10.1002/ecj.11645 · Cited by 19
Intrinsic Impurities in Glass Alkali-Vapor Cells
Patton, B., Ishikawa, K., Jau, Y., & Happer, W. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.027601 · Cited by 19
Non-classical states of atomic ensembles: fundamentals and applications in quantum metrologyPreprint
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2016) · arXiv (Cornell University) · Cited by 19
Magnetometry using fluorescence of sodium vapor
Fan, T., Zhang, L., Yang, X., Cui, S., Zhou, T., & Feng, Y. (n.d.) · Shanghai Institute of Optics and Fine Mechanics, CAS Institutional Repository · Cited by 19
Four-channel optically pumped magnetometer for a magnetoencephalography sensor array
Iivanainen, J., Carter, T. R., Dhombridge, J. E., Read, T. S., Campbell, K., Abate, Q., Ridley, D. M., Borna, A., & Schwindt, P. D. D. (2024) · Optics Express · doi:10.1364/oe.517961 · Cited by 18
“[1]) operating in the spin-exchange-relaxation-free (SERF) regime [2] are among the most sensitive magnetic-field sensors, achieving sensitivity levels as low as 0.16 fT/rt-Hz [3] and 0.54 fT/rt-Hz [4].”
InfluentialAn optically pumped magnetic gradiometer for the detection of human biomagnetism
Cook, H., Bezsudnova, Y., Koponen, L. M., Jensen, O. B., Barontini, G., & Kowalczyk, A. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad3d81 · Cited by 25
“Optically pumped magnetometers (OPMs) based on thermal atoms are able to achieve subfemtotesla sensitivities [14] and do not require cryogenics, so that they are compact, portable and inexpensive.”
BackgroundCompact high-bandwidth single-beam optically-pumped magnetometer for biomagnetic measurement
Wu, T., Xiao, W., Peng, X., Wu, T., & Guo, H. M. (2024) · Biomedical Optics Express · doi:10.1364/boe.545624 · Cited by 19
Optically Pumped Semiconductor Lasers for Precision Spectroscopic Applications
Alford, W. J., Fetzer, G. J., Epstein, R. J., Sandalphon, Lieu, N. V., Ranta, S., Tavast, M., Leinonen, T., & Guina, M. D. (2013) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.2013.2270912 · Cited by 21
“This could result in practical quantum optical sensors such as atomic magnetometers [2], [3], atom interferometer gyroscopes [4], and atomic clocks [5].”
BackgroundSimultaneous measurement of magnetic field and inertia based on hybrid optical pumping
Quan, W., Li, Y., & Liu, B. (2015) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/110/60002 · Cited by 18
Null polarimetry near shot noise limit at 1 Hz
He, D., Xie, B., & Feng, S. (2016) · Review of Scientific Instruments · doi:10.1063/1.4945310 · Cited by 18
Wang, K., Lu, J., Yan, Y., Tang, J., Ye, M., Yin, K., Chai, Z., Zhou, B., Ning, X., & Han, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3136213 · Cited by 18
In Situ Compensation of Triaxial Magnetic Field Gradient for Atomic Magnetometers
Yang, K., Lu, J., Ma, Y., Wang, Z., Sun, B., Wang, Y., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162607 · Cited by 29
Pang, H., Fan, W., Liu, F., Wu, Z., Yuan, Q., Du, P., Zhou, X., & Quan, W. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114005 · Cited by 19
Alignment-Based Optically Pumped Magnetometer Using a Buffer-Gas Cell
Rushton, L. M., Elson, L., Meraki, A., & Jensen, K. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064047 · Cited by 18
Atomic Spin Detection Method Based on Spin‐Selective Beam‐Splitting Metasurface
Xu, Y., Xu, Y., Sun, J., Mao, Y., Chai, Z., & Li, J. (2023) · Advanced Optical Materials · doi:10.1002/adom.202301353 · Cited by 18
Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell
Qi, Y., Li, B., Wang, S., Xu, N., Qian, Y., & Lu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3460884 · Cited by 19
“To compare the theoretical model (6) with the actual experimental values, we choose a certain frequency as a reference point [39].”
BackgroundPolarization rotation under two-photon Raman resonance for magnetometry
Pradhan, S., Behera, R., & Das, A. K. (2012) · Applied Physics Letters · doi:10.1063/1.4705424 · Cited by 18
Tests of Lorentz Violation in Atomic and Optical Physics
Russell, N. (2005) · Physica Scripta · doi:10.1088/0031-8949/72/6/n04 · Cited by 24
Zhu, Y., Chen, C.-H., Wilson, Z., Savukov, I., & Hilty, C. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.06.014 · Cited by 18
Yao, H., Li, Y., Ma, D., Cai, J., Zhao, J., & Ding, M. (2018) · Optics Express · doi:10.1364/oe.26.028682 · Cited by 18
Spatially-selective in situ magnetometry of ultracold atomic clouds
Elíasson, O., Heck, R., Laustsen, J. S., Napolitano, M., Müller, R., Bason, M. G., Arlt, J. J., & Sherson, J. F. (2019) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ab0bd6 · Cited by 22
Jiang, L., Duan, L., Liu, J., Liang, Y., Quan, W., & Fang, J. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3033933 · Cited by 20
Talker, E., Arora, P., Zektzer, R., Sebbag, Y., Dikopoltsev, M., & Levy, U. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.l051001 · Cited by 18
Zhang, H., Zou, S., Chen, X., & Quan, W. (2015) · Journal of Sensors · doi:10.1155/2015/491746 · Cited by 20
A proposal for a gradient magnetometer atom interferometer
Davis, J. P., & Narducci, F. A. (2008) · Journal of Modern Optics · doi:10.1080/09500340802468633 · Cited by 18
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.