A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 301–400 of 1,000
High-performance magnetic field sensor based on superconducting quantum interference filters
Caputo, P., Oppenländer, J., Häussler, C., Tomes, J., Friesch, A., Träuble, T., & Schopohl, N. (2004) · Applied Physics Letters · doi:10.1063/1.1787165 · Cited by 50
Cavity magnon polariton based precision magnetometry
Crescini, N., Braggio, C., Carugno, G., Ortolan, A., & Ruoso, G. (2020) · Applied Physics Letters · doi:10.1063/5.0024369 · Cited by 43
Harel, E., Schröder, L., & Xu, S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113018 · Cited by 44
Evaluation of realistic layouts for next generation on-scalp MEG: spatial information density maps
Riaz, B., Pfeiffer, C., & Schneiderman, J. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-07046-6 · Cited by 42
Developing Next-Generation Brain Sensing Technologies—A Review
Robinson, J. T., Xie, C., Pohlmeyer, E. A., Gather, M. C., Kemere, C. T., Kitching, J. E., Malliaras, G. G., Marblestone, A. H., Shepard, K. L., & Stieglitz, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931159 · Cited by 50
“Recent improvements in the sensitivity of atomic magnetometers [117], which are based on the precession of the spins of alkali atoms in the vapor phase, now allow these”
BackgroundWide-bandwidth atomic magnetometry via instantaneous-phase retrieval
Wilson, N., Perrella, C., Anderson, R., Luiten, A. N., & Light, P. S. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.013213 · Cited by 42
“Superconducting quantum interference devices (SQUIDs) [17, 18] and optical atomic magnetometers (OAMs) [12, 19, 20] reign as exquisitely sensitive detectors of static and slowly changing magnetic fields with fT/ √ Hz precision.”
BackgroundOptimized gas pressure of an Rb vapor cell in a single-beam SERF magnetometer
Wang, Y., Jin, G., Tang, J., Zhou, W., Han, B., Zhou, B., & Shi, T. (2021) · Optics Express · doi:10.1364/oe.447456 · Cited by 47
Kozlov, M. G., & Derevianko, A. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.063001 · Cited by 42
Atomic spin-exchange collisions in magnetic fields
Xiao, W., Wu, T., Peng, X., & Guo, H. M. (2021) · Physical Review A · doi:10.1103/physreva.103.043116 · Cited by 40
Nested Magnetic Field Compensation With Regulated Coefficients for Bio-Magnetic Field Measurement
Wei, Y., Cheng, L., Niu, Y., Chen, S., & Ye, C. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3244249 · Cited by 46
“the magnetic field sensitivity of fT level [14], [15], [16].”
BackgroundNishi, K., Ito, Y., & Kobayashi, T. (2018) · Optics Express · doi:10.1364/oe.26.001988 · Cited by 43
Suppression of Light Shift for High-Density Alkali-Metal Atomic Magnetometer
Lu, J., Quan, W., Ding, M., Qi, L., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877771 · Cited by 42
“achieved very high sensitivity especially when operating in the spin-exchange relaxation-free (SERF) regime [9]–[12].”
BackgroundHuss, A., Lammegger, R., Windholz, L., Alipieva, E. A., Gateva, S., Petrov, L., Taskova, E. T., & Todorov, G. (2006) · Journal of the Optical Society of America B · doi:10.1364/josab.23.001729 · Cited by 41
Kimball, D. F. J., Lacey, I., Valdez, J., Swiatlowski, J. L., Rios, C., Peregrinaramirez, R., Montcrieffe, C., Kremer, J., Dudley, J., & Sanchez, C. (2013) · Annalen der Physik · doi:10.1002/andp.201300036 · Cited by 41
Force‐Induced Remnant Magnetization Spectroscopy for Specific Magnetic Imaging of Molecules
Yao, L., & Xu, S. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201007297 · Cited by 38
Effects of AC magnetic field on spin-exchange relaxation of atomic magnetometer
Lu, J., Qian, Z., Fang, J., & Quan, W. (2016) · Applied Physics B · doi:10.1007/s00340-016-6336-9 · Cited by 41
Perry, A. R., Bulatowicz, M. D., Larsen, M., Walker, T. G., & Wyllie, R. (2020) · Optics Express · doi:10.1364/oe.408486 · Cited by 39
Application of VCSEL in Bio-Sensing Atomic Magnetometers
Zhou, P., Quan, W., Wei, K., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12121098 · Cited by 42
“As mentioned above, chip-scale atomic magnetometers have gradually improved in sensitivity and have reached subfemtotesla magnitude [88,89], enabling sensitivity similar to that of SQUIDs, and without the need for ultra-low temperature environments.”
BackgroundPerformance of Low-Noise Ferrite Shield in a K-Rb-21Ne Co-Magnetometer
Fan, W., Quan, W., Liu, F., Pang, H., Li, X., & Liu, G. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2952121 · Cited by 41
“Digital Object Identifier 10.1109/JSEN.2019.2952121 in different frequency domain, such as continuously pumped SERF vector AMs [11], pulsed pumped SERF scalar AMs [12] and tunable radio-frequency AMs [13].”
BackgroundInfluentialPrecision measurement and frequency metrology with ultracold atoms
Zhang, X., & Ye, J. (2016) · National Science Review · doi:10.1093/nsr/nww013 · Cited by 51
“In the field of atomic, molecular and optical physics, precision measurement has provided important tests of fundamental laws of physics, stimulated the development of new frontiers in science and technology, and seeded a wide range of revolutionary applications that bring important benefits to our society, including…”
BackgroundWall interactions of spin-polarized atoms
Wu, Z. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.035006 · Cited by 42
Magnetic fields from skeletal muscles: a valuable physiological measurement?
Garcia, M. A. C., & Baffa, O. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00228 · Cited by 41
“In the last decades, the atomic magnetometers have reached higher levels of sensitivity (subfemtotesla), more compact designs, with few cubic centimeters, and with no need of being cryogenically cooled (Kominis et al., 2003; Shah andWakai, 2013).”
BackgroundFang, J., Wang, T., Zhang, H., Li, Y., & Zou, S. (2014) · Review of Scientific Instruments · doi:10.1063/1.4902567 · Cited by 41
All optical sensor for automated magnetometry based on coherent population trapping
Belfi, J., Bevilacqua, G., Biancalana, V., Dancheva, Y. V., & Moi, L. (2007) · Journal of the Optical Society of America B · doi:10.1364/josab.24.001482 · Cited by 37
Quantum sensing using imbalanced counter-rotating Bose–Einstein condensate modes
Pelegrí, G., Mompart, J., & Ahufinger, V. (2018) · New Journal of Physics · doi:10.1088/1367-2630/aae107 · Cited by 47
Jaufenthaler, A., Schier, P. P., Middelmann, T., Liebl, M., Wiekhorst, F., & Baumgarten, D. (2020) · Sensors · doi:10.3390/s20030753 · Cited by 39
“The magnetometers operate in the spin exchange relaxation-free (SERF) regime [13,20].”
BackgroundIn-Situ Measurement of Electrical-Heating-Induced Magnetic Field for an Atomic Magnetometer
Lu, J., Wang, J., Yang, K., Zhao, J., Quan, W., Han, B., & Ding, M. (2020) · Sensors · doi:10.3390/s20071826 · Cited by 43
A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Clancy, R. J., Gerginov, V., Alem, O., Becker, S., & Knappe, S. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac18fb · Cited by 37
“To rival the sensitivities of SQUIDS,OPMsmust operate in the spin-exchange relaxation-free (SERF) regime (Allred et al 2002, Kominis et al 2003).”
MethodAmirsolaimani, B., Gangopadhyay, P., Persoons, A. P., Showghi, S. A., LaComb, L., Norwood, R. A., & Peyghambarian, N. N. (2018) · Optics Letters · doi:10.1364/ol.43.004615 · Cited by 37
RetractedSABRE and PHIP pumped RASER and the route to chaos
Appelt, S., Lehmkuhl, S., Fleischer, S., Joalland, B., Ariyasingha, N. M., Chekmenev, E. Y., & Theis, T. (2020) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2020.106815 · Cited by 37
Optically pumped magnetometers enable a new level of biomagnetic measurements
Sander, T. H., Jodko-Władzińska, A., Hartwig, S., Brühl, R., & Middelmann, T. (2019) · Advanced Optical Technologies · doi:10.1515/aot-2020-0027 · Cited by 44
Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method
Chen, Y., Zhao, L., Zhang, N., Yu, M., Ma, Y., Han, X., Zhao, M., Lin, Q., Yang, P., & Jiang, Z. (2022) · Optics Express · doi:10.1364/oe.450571 · Cited by 42
Sensitivity of condensed-matter P - and T -violation experiments
Budker, D., Lamoreaux, S. K., Sushkov, A. O., & Sushkov, O. P. (2006) · Physical Review A · doi:10.1103/physreva.73.022107 · Cited by 37
Long‐Range, High‐Resolution Magnetic Imaging of Nanoparticles
Yao, L., & Xu, S. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902114 · Cited by 37
Analysis of molecular structures by homo- and hetero-nuclear J-coupled NMR in ultra-low field
Appelt, S., Häsing, F. W., Kühn, H., Sieling, U., & Blümich, B. (2007) · Chemical Physics Letters · doi:10.1016/j.cplett.2007.03.096 · Cited by 39
Phenomena in J -coupled nuclear magnetic resonance spectroscopy in low magnetic fields
Appelt, S., Häsing, F. W., Kühn, H., & Blümich, B. (2007) · Physical Review A · doi:10.1103/physreva.76.023420 · Cited by 42
Qin, B., Wang, Z., Pang, H., Xia, H., & Lei, X. (2025) · Measurement · doi:10.1016/j.measurement.2025.117426 · Cited by 38
Self-Calibrating Vector Atomic Magnetometry through Microwave Polarization Reconstruction
Thiele, T., Lin, Y., Brown, M. O., & Regal, C. A. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.153202 · Cited by 38
Ito, S., Ito, Y., & Kobayashi, T. (2019) · Optics Express · doi:10.1364/oe.27.008037 · Cited by 36
Single-beam three-axis optically pumped magnetometers with sub-100 femtotesla sensitivity
Xiao, W., Wu, Y., Zhang, X., Feng, Y., Sun, C., Wu, T., Chen, J., Peng, X., & Guo, H. M. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac00d9 · Cited by 36
Guo, Q., Hu, T., Chen, C.-Q., Feng, X., Wu, Z., Zhang, Y., Zhang, M., Chang, Y., & Yang, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3102146 · Cited by 38
Visualization of magnetic fields with cylindrical vector beams in a warm atomic vapor
Qiu, S., Wang, J., Castellucci, F., Cao, M., Zhang, S., Clark, T. W., Franke‐Arnold, S., Gao, H., & Fu-li, L. (2021) · Photonics Research · doi:10.1364/prj.418522 · Cited by 40
Li, S., Ma, D., Lu, J., Xing, B., Wang, K., Gao, Y., & Han, B. (2022) · Measurement · doi:10.1016/j.measurement.2022.111878 · Cited by 37
Budker, D. (2003) · Nature · doi:10.1038/422574a · Cited by 36
Magnetoneurography: theory and application to peripheral nerve disorders
Mackert, B.-M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.07.028 · Cited by 36
“54 fT/Hz (Kominis et al., 2003), shielding allowing measurements in a magnetometer mode, and new sensor designs, e.”
Wang, B., Peng, T., Jiang, Z., Xu, J., Qu, J., & Dai, X. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01028 · Cited by 37
Sun, B., Zhai, Y., Bandaru, S., Cheng, T., Huang, Y., Chen, K., Zheng, S., Han, B., Li, J., Ma, D., et al. (2026) · Nano Research · doi:10.26599/nr.2026.94908875 · Cited by 46
Zhang, X., Qin, J., Wang, Y., & Chen, C. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2863519 · Cited by 36
“SERF AMs have the possibility of achieving experimental femtotesla magnitude in magnetic detection only because the remove of broadening of spin-exchange collisions becomes a reality, called SERF regime [4].”
BackgroundStudy of Shielding Ratio of Cylindrical Ferrite Enclosure With Gaps and Holes
Ma, D., Ding, M., Lu, J., Yao, H., Zhao, J., Yang, K., Cai, J., & Han, B. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2904719 · Cited by 35
“needs to pass through a shielding system [5], [27] and access holes affect the magnetic shielding effectiveness [28], [29].”
BackgroundA kilohertz bandwidth and sensitive scalar atomic magnetometer using an optical multipass cell
Li, S., Liu, J., Jin, M., Tetteh, A. K., Dai, P., Xu, Z., & Nwodom, T. E.-T. (2022) · Measurement · doi:10.1016/j.measurement.2022.110704 · Cited by 40
Three-Dimensional Magnetic Field Measurements in a Single SERF Atomic-Magnetometer Cell
Gusarov, A., Levron, D., Paperno, E., Shuker, R., & Baranga, A. B.-A. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2021404 · Cited by 37
Experimental demonstration of the sensitivity of an optically pumped quantum magnetometer
Alexandrov, E. B., Balabas, M. V., Vershovskii, A. K., & Pazgalev, A. S. (2004) · Technical Physics · doi:10.1134/1.1767891 · Cited by 35
Metasurfaces toward Optical Manipulation Technologies for Quantum Precision Measurement
Xu, Y., Su, X., Chai, Z., & Li, J. (2023) · Laser & Photonics Review · doi:10.1002/lpor.202300355 · Cited by 41
Sub-Hertz resonance by weak measurement
Qu, W., Jin, S., Sun, J., Jiang, L., Wen, J., & Xiao, Y. (2020) · Nature Communications · doi:10.1038/s41467-020-15557-6 · Cited by 39
Robust, High-speed, All-Optical Atomic Magnetometer
Higbie, J. M., Corsini, E., & Budker, D. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 34
Effects of Probe Laser Intensity on Co-Magnetometer Operated in Spin-Exchange Relaxation-Free Regime
Fu, Y., Fan, W., Ruan, J., Liu, Y., Lu, Z., & Quan, W. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3144738 · Cited by 39
Hu, Z.-K., Duan, X., Zhou, M.-K., Sun, B.-L., Zhao, J., Huang, M., & Luo, J. (2011) · Physical Review A · doi:10.1103/physreva.84.013620 · Cited by 39
Enhancement of SQUID-Detected NMR Signals with Hyperpolarized Liquid Xe129 in a 1 μT Magnetic Field
Heckman, J. J., Ledbetter, M. P., & Romalis, M. V. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.067601 · Cited by 34
Self-citationRushton, L. M., Pyragius, T., Meraki, A., Elson, L., & Jensen, K. (2022) · Review of Scientific Instruments · doi:10.1063/5.0102402 · Cited by 37
Long-baseline quantum sensor network as dark matter haloscope
Jiang, M., Hong, T., Hu, D., Chen, Y., Yang, F. W., Hu, T., Yang, X., Shu, J., Zhao, Y., Peng, X., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47566-0 · Cited by 46
“9997, which is negligible.”
Fan, W., Liu, G., Li, R., Quan, W., Jiang, L., & Duan, L. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa7888 · Cited by 33
Spatial Signature Analysis of Submarine Magnetic Anomaly at Low Altitude
Zhou, J., Chen, J., & Shan, Z. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2735940 · Cited by 33
Keaveney, J., Wrathmall, S. A., Adams, C. S., & Hughes, I. G. (2018) · Optics Letters · doi:10.1364/ol.43.004272 · Cited by 33
Detection of low-conductivity objects using eddy current measurements with an optical magnetometer
Jensen, K., Zugenmaier, M., Arnbak, J., Stærkind, H., Balabas, M. V., & Polzik, E. S. (2019) · Physical Review Research · doi:10.1103/physrevresearch.1.033087 · Cited by 40
Li, J., Quan, W., Han, B., Wang, Z., & Fang, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2950420 · Cited by 34
“ATOMIC magnetometers operating in spin exchange relaxation free (SERF) demonstrate ultra-high sensitivity on the sub-femtotesla level [1], [2].”
BackgroundJaufenthaler, A., Kornack, T. W., Lebedev, V., Limes, M. E., Körber, R., Liebl, M., & Baumgarten, D. (2021) · Sensors · doi:10.3390/s21041212 · Cited by 36
“On the large time-scale it can be observed that the MNP are saturated for excitation fields ≥10 mT, which was also observed in SQUID-MRX measurements of the same sample.”
BackgroundInfluentialSelf-citationEvolution of MEG : A first MEG ‐feasible fluxgate magnetometer
Koshev, N., Butorina, A. V., Skidchenko, E., Kuzmichev, A. N., Ossadtchi, A. E., Ostras, M., Fedorov, M. V., & Vetoshko, P. M. (2021) · Human Brain Mapping · doi:10.1002/hbm.25582 · Cited by 35
Wu, K.-Y., Chen, S. Y., Sun, G. A., Peng, S., Peng, M., & Yan, H. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.051802 · Cited by 36
Optimal buffer gas pressure in dual-beam spin-exchange relaxation-free magnetometers
Lu, J., Zhang, S., Zhou, Y., Yan, Y., Lu, F., Wang, K., Zhai, Y., & Ye, M. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113928 · Cited by 34
Parameter optimisation of miniaturised SERF magnetometer below relaxation rate saturation region
Li, R., Liu, Y., Li, C., Li, S., Li, J., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.112733 · Cited by 36
Quantum Sensing of Electric Fields Using Spin-Correlated Radical Ion Pairs
Xie, F., Mao, H., Lin, C., Feng, Y., Stoddart, J. F., Young, R. M., & Wasielewski, M. R. (2023) · Journal of the American Chemical Society · doi:10.1021/jacs.3c04212 · Cited by 36
Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer
Lu, J., Qian, Z., Fang, J., & Quan, W. (2015) · Review of Scientific Instruments · doi:10.1063/1.4927720 · Cited by 34
Superconducting Quantum Interference Filters as Absolute Magnetic Field Sensors
Caputo, P., Tomes, J., Oppenländer, J., Häussler, C., Friesch, A., Träuble, T., & Schopohl, N. (2005) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2003.850193 · Cited by 36
“field sensitivity in a reasonable bandwidth ( 30 Hz) [5]–[7].”
BackgroundMa, Y., Qiao, Z., Yu, M., Wang, Y., Chen, Y., Luo, G., Yang, P., Lin, Q., Zhao, L., Zhang, Y., et al. (2022) · Applied Physics Letters · doi:10.1063/5.0105945 · Cited by 35
Interference in Atomic Magnetometry
Jiang, M., Xu, W., Li, Q., Wu, Z., Suter, D., & Peng, X. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000078 · Cited by 31
Recent Progress on Micro-Fabricated Alkali Metal Vapor Cells
Wang, X., Ye, M., Lu, F., Mao, Y., Tian, H., & Li, J. (2022) · Biosensors · doi:10.3390/bios12030165 · Cited by 38
A low-noise multilayer mu-metal thin shell magnetic shield for ultra-highly sensitive atomic sensors
Gao, Y., Ma, D., Wang, K., Xu, X., Li, S., Dou, Y., & Li, J. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114207 · Cited by 34
Study of the operation temperature in the spin-exchange relaxation free magnetometer
Fang, J., Li, R., Duan, L., Chen, Y., & Quan, W. (2015) · Review of Scientific Instruments · doi:10.1063/1.4927460 · Cited by 32
Magnetometry via a double-pass continuous quantum measurement of atomic spin
Chase, B. A., Baragiola, B. Q., Partner, H. L., Black, B. D., & Geremia, J. M. (2009) · Physical Review A · doi:10.1103/physreva.79.062107 · Cited by 33
Application of atomic magnetometry in magnetic particle detection
Xu, S., Donaldson, M. H., Pines, A., Rochester, S., Budker, D., & Yashchuk, V. V. (2006) · Applied Physics Letters · doi:10.1063/1.2400077 · Cited by 32
Kimball, D. F. J., Jacome, L., Guttikonda, S., Bahr, E. J., & Chan, L. F. (2009) · Journal of Applied Physics · doi:10.1063/1.3225917 · Cited by 34
Atomic-Signal-Based Zero-Field Finding Technique for Unshielded Atomic Vector Magnetometer
Dong, H., Lin, H., & Tang, X. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2216951 · Cited by 34
“In recent years, atomic vector magnetometer working under spin-exchange relaxation free (SERF) regime emerged as a promising noncryogenic, low-cost alternative to SQUID magnetometer which has achieved a sensitivity of sub-fT/Hz1/2 [4]–[6].”
BackgroundThree-Axis Atomic Magnetometer Employing Longitudinal Field Modulation
Ding, Z., Yuan, J., Lu, G., Li, Y., & Long, X. (2017) · IEEE photonics journal · doi:10.1109/jphot.2017.2743013 · Cited by 32
“Compared with a superconducting quantum interference device (SQUID) [4], [5], an alkali-metal atomic magnetometer can achieve comparable and even higher sensitivity with non-cryogenic operation, so it is widely regarded as a more ideal option [6], [7].”
BackgroundOptimization of atomic Faraday filters in the presence of homogeneous line broadening
Zentile, M. A., Keaveney, J., Mathew, R. S., Whiting, D. J., Adams, C. S., & Hughes, I. G. (2015) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/48/18/185001 · Cited by 37
Long, T., Song, X., Duan, Z., Suo, Y., Wu, Z., Jia, L., & Han, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3341139 · Cited by 42
“Romalis et al. [9] initially proposed a highly sensitive alkali-metal atomic magnetometer based on the SERF regime, achieving a measurement sensitivity of 0.54 fT / Hz 1 / 2 by 2003 [10].”
BackgroundMethodInfluentialOptical Parameter Decoupling and Optimization for Elliptically Polarized Atomic Magnetometer
Yan, Y., Zhang, S., Liu, Z., Zhan, D., Liu, Z., Li, X., Zhou, Y., & Lu, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3343783 · Cited by 35
Liu, Y., Yang, J., Cao, F., Zhang, X., & Zheng, S. (2024) · Materials · doi:10.3390/ma17225469 · Cited by 37
“Spin-Exchange Relaxation-Free (SERF) atomic magnetometer [9] has surpassed Superconducting Quantum Interference Device (SQUID) [10] as the new quantum magnetic sensor, which improves the sensitivity of magnetic measurement from the order of fT to aT theoretically [11].”
Correlation function of spin noise due to atomic diffusion
Lucivero, V. G., McDonough, N. D., Dural, N., & Romalis, M. V. (2017) · Physical Review A · doi:10.1103/physreva.96.062702 · Cited by 35
Self-citationStudy of Magnetic Noise of a Multi-Annular Ferrite Shield
Lu, J., Ma, D., Yang, K., Quan, W., Zhao, J., Xing, B., Han, B., & Ding, M. (2020) · IEEE Access · doi:10.1109/access.2020.2976785 · Cited by 31
“However, the innermost layer of μ-metal shields generates magnetic noise in the range of 1–10 fT Hz−1/2 at the center of the shield attributed to Johnson noise (its electrical resistivity ρ∼10−6 m) [9]–[12].”
BackgroundPT -Symmetric Feedback Induced Linewidth Narrowing
Tang, Y., Liang, C., Wen, X., Li, W., Xu, A., & Liu, Y. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.193602 · Cited by 40
Localizing on-scalp MEG sensors using an array of magnetic dipole coils
Pfeiffer, C., Andersen, L. M., Lundqvist, D., Hämäläinen, M., Schneiderman, J. F., & Oostenveld, R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0191111 · Cited by 35
“While there have been several reports of OPMs and high-Tc SQUIDs with noise levels as low as a few fT/Hz [18, 19], such high-performance sensors have only been produced in small quantities.”
BackgroundA hybrid-systems approach to spin squeezing using a highly dissipative ancillary system
Dooley, S., Yukawa, E., Matsuzaki, Y., Knee, G. C., Munro, W. J., & Nemoto, K. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/5/053011 · Cited by 35
Guo, Y., Wan, S., Sun, X., & Qin, J. (2019) · Applied Optics · doi:10.1364/ao.58.000734 · Cited by 29
Ultrastable Optical Magnetometry
Wilson, N., Light, P. S., Luiten, A. N., & Perrella, C. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.044034 · Cited by 33
Zero- to ultralow-field nuclear magnetic resonance and its applications
Jiang, M., Bian, J., Li, Q., Wu, Z., Su, H., Xu, M., Wang, Y., Wang, X., & Peng, X. (2021) · Fundamental Research · doi:10.1016/j.fmre.2020.12.007 · Cited by 46
“In particular, atomic magnetometers based on spin-exchange relaxation-free mechanics have reached at the subfemtotesla level [27, 34].”
BackgroundInfluentialAnalysis of atomic magnetometry using metasurface optics for balanced polarimetry
Yang, X., Benelajla, M., Carpenter, S., & Choy, J. T. (2023) · Optics Express · doi:10.1364/oe.486311 · Cited by 31
Sub-Shot-Noise Magnetometry with a Correlated Spin-Relaxation Dominated Alkali-Metal Vapor
Kominis, I. K. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.073002 · Cited by 32
Self-citationSub-nanotesla sensitivity at the nanoscale with a single spin
Zhao, Z., Ye, X., Xu, S., Yu, P., Yang, Z., Kong, X., Wang, Y., Xie, T., Shi, F., & Du, J. (2023) · National Science Review · doi:10.1093/nsr/nwad100 · Cited by 38
Afach, S., Aybas, D., Bekker, H., Buchler, B. C., Budker, D., Cervantes, K., Derevianko, A., Eby, J., Figueroa, N. L., Folman, R., et al. (2023) · Annalen der Physik · doi:10.1002/andp.202300083 · Cited by 57
“In the first incarnation of the GNOME, various OAMs employed different elements (Rb and Cs) and were based on different techniques; spin-exchange-relaxation-free (SERF), [76] M x , [77] and nonlinear-magneto-optical-rotation (NMOR) [78] mag-netometers were used for the measurements.”
MethodPulsed vector atomic magnetometer using an alternating fast-rotating field
Wang, T., Lee, W., Limes, M. E., Kornack, T. W., Foley, E., & Romalis, M. V. (2025) · Nature Communications · doi:10.1038/s41467-025-56668-2 · Cited by 39
“Any slight tilt of the leading field in the transverse direction can be detected at this sensitivity level, corresponding to polar angle sensitivities of 6 nrad / √”
Self-citation
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.