Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 801–900 of 1,000
Ultra-Sensitive Optical Atomic Magnetometers and Their Applications
Savukov, I. (2010) · InTech eBooks · doi:10.5772/7153 · Cited by 13
“The most sensitive SERF magnetometer (Kominis et al., 2003) was implemented on a special non-magnetic optical table with a multi-layer mu-metal shield reducing the ambient magnetic field by a factor of 1 million and due to the complexity of experimental arrangement and high price,…”
BackgroundMethodInfluentialRomalis, M. V. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.209 · Cited by 11
Self-citationHan, S., Granwehr, J., Garcia, S., McDonnell, E. E., & Pines, A. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.06.024 · Cited by 11
“It can be a magnetometer like a Superconducting Quantum Interference Device (SQUID) [3] or an atomic magnetometer [4,5] which scale favorably towards low detection fields.”
MethodTheoretical and experimental investigation of magnetic resonance on the Cs hyperfine structure
Ding, Z., Yuan, J., Wang, G., Luo, H., & Long, X. (2017) · Physics Letters A · doi:10.1016/j.physleta.2017.05.023 · Cited by 11
Atom-based quantum sensing of electromagnetic fields
Kitching, J. E., Shaffer, J. P., & Budker, D. (2025) · Optica · doi:10.1364/optica.569334 · Cited by 18
Ye, L., Pang, H., Liu, Y., Quan, J., Ma, L., Fan, W., & Quan, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3660442 · Cited by 11
“However, the high electrical conductivity of µ -metal can lead to significant intrinsic magnetic noise, with magnetic noise levels potentially exceeding the order of 50 fT / Hz 1 / 2 , becoming the main factor limiting the sensitivity and long-term stability of atomic sensors [6], [15].”
Picotesla fiberized diamond-based AC magnetometer
Zhang, S.-C., Liu, Y., Shan, L., Gao, X., Geng, J., Cui, Y., Dong, Y., Chen, X.-D., Guo, G., & Sun, F. (2024) · Photonics Research · doi:10.1364/prj.522062 · Cited by 12
Single-beam three-axis SERF atomic magnetometer based on coordinate system rotation
Zhang, J., Chen, T., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2024) · Optics Express · doi:10.1364/oe.524308 · Cited by 11
Superconducting Quantum Magnetometer Based on Flux Focusing Effect for High-Sensitivity Applications
Vettoliere, A., & Granata, C. (2024) · Sensors · doi:10.3390/s24123998 · Cited by 11
“For these studies, the most used quantum magnetic sensors are Superconducting Quantum Interference Devices (SQUIDs) [8–11], optically pumped atom magnetometers [12,13], and diamond magnetometers based on nitrogen-vacancy centers.”
MethodIn-situ magnetic fields monitoring and compensation for zero-field atomic magnetometers
Yan, Y., Zhang, K., Liu, Z., Liu, Z., Li, X., Zhou, Y., & Lu, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.115410 · Cited by 12
Qin, B., Fan, W., Wang, Z., Wang, R., Xia, H., Li, F., Liu, Z., & Quan, W. (2024) · Measurement · doi:10.1016/j.measurement.2024.115487 · Cited by 10
Femtotesla atomic magnetometer with counter-propagating optical sideband pumping
Peng, J., Xu, A., & Liu, B. (2024) · Optics Letters · doi:10.1364/ol.540032 · Cited by 10
Bandwidth compensation for ultra-high-sensitivity SERF magnetometers in magnetocardiac sensing
Jia, Y., Pei, H., Yang, Y., Jiang, L., Lu, J., Ning, X., Cui, Y., & Xiang, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.116095 · Cited by 10
Accurate vector optically pumped magnetometer with microwave-driven Rabi frequency measurements
Kiehl, C., Menon, T. S., Knappe, S. A., Thiele, T., & Regal, C. A. (2024) · Optica · doi:10.1364/optica.542502 · Cited by 12
“…I x , I y , I z ) j that corresponds to a magnetic field direction ( α , β ) j with norm B j ≈ 50 µ T. double-frequency The DC magnetic field strengths are fitted from FID measurements using a double-frequency model accounting for the different precessional frequencies in the F = 1,2 manifolds [1].”
BackgroundMethodInfluentialQuantum Thermodynamic Derivation of the Energy Resolution Limit in Magnetometry
Kominis, I. K. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.263201 · Cited by 14
Self-citationFree-induction-decay magnetometer based on synchronous optical pumping and RF pulse modulation
Xu, J., Jiang, L., Liu, J., Liu, J., Chen, Y., Zhu, J., Fang, C., Shao, Q., Zou, Y., & Bai, H. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00373-y · Cited by 12
Magnetic and optical control in thermal atomic spin ensembles: Principles and applications
Fan, S., Pei, H., Quan, W., Jia, Y., Liu, J., & Fan, W. (2025) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-025-2718-0 · Cited by 11
Navigation in the future: Review of quantum sensing in navigation
Pei, H., Fan, W., Duan, L., Liu, F., Pang, H., Li, R., Feng, Y., Liu, Y., Wang, Y. H., Yuan, H., et al. (2025) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-025-2699-1 · Cited by 12
Taue, S., Sugihara, Y., Kobayashi, T., Ishikawa, K., & Kamada, K. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.116604 · Cited by 12
Potassium spin polarization lifetime for a 30-carbon chain siloxane film
Hibberd, A. M., Bergman, S. L., Zhong, Y. L., & Bernasek, S. L. (2012) · The Journal of Chemical Physics · doi:10.1063/1.4761934 · Cited by 12
Sacrificial microchannel sealing by glass-frit reflow for Chip Scale Atomic Magnetometer
Tsujimoto, K., Hirai, Y., Sugano, K., Tsuchiya, T., & Tabata, O. (2011) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2011.5734438 · Cited by 10
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_78 · Cited by 12
Interleaved NQR detection using atomic magnetometers
Quiroz, D. R., Cooper, R. J., Foley, E. L., Kornack, T. W., Lee, G. J., & Sauer, K. L. (2022) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2022.107288 · Cited by 10
Self-citationDual-beam room-temperature atomic magnetometer with high sensitivity and large dynamic range
Liu, B., Peng, J., Wang, H., Fang, C., Wang, J., Zhao, X., & Deng, L. (2022) · Applied Physics Express · doi:10.35848/1882-0786/acaa1c · Cited by 11
Characterization of 87Rb MEMS vapor cells for miniature atomic magnetometers
Jiang, M., Zhai, H., Jiang, C., Wang, J., Chen, C., Zhang, Q., Wu, D., Zhang, B., Zeng, Z., Lin, J., et al. (2023) · Applied Physics Letters · doi:10.1063/5.0149388 · Cited by 15
On-chip fabrication of alkali-metal vapor cells utilizing an alkali-metal source tablet
Tsujimoto, K., Ban, K., Hirai, Y., Sugano, K., Tsuchiya, T., Mizutani, N., & Tabata, O. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/11/115003 · Cited by 12
Characterization of alkali-metal vapor cells fabricated with an alkali-metal source tablet
Ban, K., Hirai, Y., Tsujimoto, K., Terao, A., Mizutani, N., Kobayashi, T., & Tabata, O. (2016) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.4963108 · Cited by 11
Sensitivity of proposed search for axion-induced magnetic field using optically pumped magnetometers
Chu, P.-H., Duffy, L., Kim, Y. J., & Savukov, I. (2018) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.97.072011 · Cited by 10
Multi-objective optimization of multilayer passive magnetic shield based on genetic algorithm
Li, J., Wang, Z., & Quan, W. (2019) · AIP Advances · doi:10.1063/1.5131250 · Cited by 11
A feed-forward measurement scheme for periodic noise suppression in atomic magnetometry
O’Dwyer, C., Ingleby, S. J., Chalmers, I. C., Griffin, P. F., & Riis, E. (2020) · Review of Scientific Instruments · doi:10.1063/5.0002964 · Cited by 11
Tests of Lorentz Violation in Atomic and Optical Physics
Russell, N. (2005) · CERN Document Server (European Organization for Nuclear Research) · Cited by 10
Fiber-tip endoscope for optical and microwave control
Dix, S., Gutsche, J., Waller, E. H., von Freymann, G., & Widera, A. (2022) · Review of Scientific Instruments · doi:10.1063/5.0100330 · Cited by 10
Ma, D., Fang, X., Lu, J., Wang, K., Sun, B., Gao, Y., Xu, X., & Han, B. (2022) · Materials · doi:10.3390/ma15238704 · Cited by 10
New Atomic Magnetometer Achieves Subfemtotesla Sensitivity
Fitzgerald, R. (2003) · Physics Today · doi:10.1063/1.1603066 · Cited by 10
Bae, I., Moon, H. S., Kim, M.-K., Lee, L., & Kim, J. B. (2008) · Applied Optics · doi:10.1364/ao.47.004849 · Cited by 10
Demonstration of an optical polarization magnifier with low birefringence
Lintz, M., Guéna, J., Bouchiat, M.-A., & Chauvat, D. (2005) · Review of Scientific Instruments · doi:10.1063/1.1879292 · Cited by 10
Atomic noise spectra in nonlinear magneto-optical rotation in a rubidium vapor
Li, H., Sautenkov, V. A., Varzhapetyan, T., Rostovtsev, Y. V., & Scully, M. O. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001702 · Cited by 10
“Magnetometers based on atom-optical techniques, such as the optical pumping magnetometers [1] and the nonlinear magneto-optical rotation (NMOR) magnetometers [2, 3, 4], have achieved sensitivities of the order of 10 T Hz.”
MethodLiu, X., Yang, Y., Ding, M., Quan, W., Hu, Y., Li, Y., Jin, W., & Fang, J. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2892479 · Cited by 11
“In 2006, the atomic magnetometer was first applied to magnetoencephalography (MEG) system due to the advantage that it did not require use of helium [12].”
MethodWang, Z., Li, J., & Xiong, Z. (2020) · OSA Continuum · doi:10.1364/osac.388223 · Cited by 10
Light narrowing of cesium magnetic-resonance lines in a radio-frequency atomic magnetometer
Fu, Y., Liu, X., & Yuan, J. (2019) · AIP Advances · doi:10.1063/1.5043231 · Cited by 10
Ioannides, A. A. (2008) · Methods in molecular biology · doi:10.1007/978-1-59745-543-5_8 · Cited by 12
“In recent years, atomic magnetometry, a method of measuring magnetic fields based on the interaction of resonant light with atomic vapor, has emerged as a potentially cheaper alternative to SQUID based sensors (15).”
Tardelli, G. P., Phan, T., Strasburger, J. F., Baffa, O., & Wakai, R. T. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12093078 · Cited by 10
Coupling of Magnetic Field Noise in Multilayer Magnetic Shields for Atomic Magnetometer
Wang, Z., Zhang, M., Yang, K., Yu, T., Lv, B., Chen, Y., Zhang, N., Guo, J., Li, D., & Wang, X. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3353834 · Cited by 9
“…with ultralow magnetic noise usually provided by magnetic shielding is the foundation of precision magnetic measurement experiments, such as ultrasensitive atomic magnetometer [1], [2], [3], exotic spin-dependent force detection [4], and neutron-electric-dipole-moment (nEDM) detection [5].”
BackgroundParameter estimation from quantum-jump data using neural networks
Rinaldi, E., Lastre, M. G., Herreros, S. G., Ahmed, S., Khanahmadi, M., Nori, F., & Muñoz, C. S. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad3c68 · Cited by 18
“…measurements have been developed and studied over the years [22–35]; such parameter estimation techniques are particularly relevant for applications such as atomic magnetometry [36–38], quantum metrology with open quantum systems [28, 39–41] or estimation of classical time-dependent signals [42].”
BackgroundAnomalous noise spectra in a spin-exchange-relaxation-free alkali-metal vapor
Mouloudakis, K., Kong, J., Sierant, A., Arkin, E., Ruiz, M. H., Jiménez-Martínez, R., & Mitchell, M. W. (2024) · Physical Review A · doi:10.1103/physreva.109.l040802 · Cited by 13
Qin, B., Wang, Z., Fan, W., Wang, R., Li, F., & Quan, W. (2024) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2024.3408872 · Cited by 9
“Q UANTUM instrumentations [1] are frontier physical measurement devices founded on information technology and quantum physics, for example, atomic clock [2], optically pumped magnetometer (OPM) [3], and spin-exchange relaxation-free comagnetometer (SERFCM) [4], [5].”
BackgroundIn Situ Measurement of High-Frequency Magnetic Field Produced by Electric Heaters in Atomic Sensors
Shao, Q., Jiang, L., Zhao, X. H., Liu, J., Fang, C., Zhu, J., Zou, Y., Lei, X., & Quan, W. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3427861 · Cited by 10
“The common heating methods for atomic cells are hot air heating [9], [10], laser heating [11], [12], and electric heating [13], [14].”
BackgroundWang, J., Liu, G., Liu, Z., Wu, Z., Wang, Q., Jie, S., & Zhang, S. (2024) · Measurement · doi:10.1016/j.measurement.2024.116328 · Cited by 9
In-situ magnetic field compensation for zero-field NMOR atomic magnetometer
Zhang, C., Liu, J., Zhao, X. H., Chen, J., Yang, J., Li, J., & Jiang, L. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116385 · Cited by 9
Suppressing the Decoherence of Alkali-Metal Spins at Low Magnetic Fields
Dikopoltsev, M., Berrebi, A., Levy, U., & Katz, O. (2025) · Physical Review Letters · doi:10.1103/physrevlett.134.143201 · Cited by 11
Current Trends and Advances in Quantum Navigation for Maritime Applications: A Comprehensive Review
Sambataro, O., Costanzi, R., Alves, J., Caiti, A., Paglierani, P., Petroccia, R., & Munafò, A. (2025) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2025.3538941 · Cited by 20
“The solution that demonstrated the highest sensitivity, i.e., the ability to detect the weakest magnetic field was proposed at Princeton [83], [84] and named spin-exchange relaxation-free (SERF).”
Flow Rate Estimation Based on Magnetic Particle Detection Using a Miniatured High-Sensitivity OPM
Liu, Y., Huang, B., Li, J., Li, R., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3565069 · Cited by 15
“One of the advantages of OPM for medical applications is that the magnetic field is generated by the subjects themselves [38].”
Superconducting Quantum Magnetometers for Brain Investigations
Bonavolontà, C., Vettoliere, A., Sorrentino, P., & Granata, C. (2025) · Sensors · doi:10.3390/s25154625 · Cited by 18
“OPMs can reach a field sensitivity less than 1 fT/Hz 1/2 [13]; however, commercial OPMs operate with a sensitivity in the order of 7–10 fT/ √ Hz, while SQUIDs are the most sensitive magnetometers available, measuring magnetic fields with a sensitivity of 1–5 fT/ √ Hz in the white noise frequency…”
A bell-bloom atomic magnetic-videorecorder with global shutter and differential readout
He, X., Dong, H., Hua, Z., Ye, H., Xu, C., Li, X., Guo, H., Li, Z., Wen, H. F., Tang, J., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01282-5 · Cited by 12
New avenues for functional neuroimaging: ultra-high field MRI and OPM-MEG
Qin, L., & Gao, J. (2021) · Psychoradiology · doi:10.1093/psyrad/kkab014 · Cited by 13
Zero field optically pumped magnetometer with independent dual-mode operation
Zhang, S., Lu, J., Zhou, Y., Lu, F., Yin, K., Zhan, D., Zhai, Y., & Ye, M. (2022) · Chinese Optics Letters · doi:10.3788/col202220.081202 · Cited by 9
Bakhshi, A., Jalaly, M., & Vahedi, M. (2022) · Optical Fiber Technology · doi:10.1016/j.yofte.2022.103134 · Cited by 9
Losses of thulium atoms from optical dipole traps operating at 532 and 1064 nm
Tsyganok, V. V., Pershin, D. A., Khlebnikov, V., Kumpilov, D. A., Pyrkh, I. A., Rudnev, A. E., Fedotova, E. A., Gaifudinov, D. V., Cojocaru, I. S., Khoruzhii, K. A., et al. (2023) · Physical Review A · doi:10.1103/physreva.107.023315 · Cited by 9
Niu, Y., & Ye, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3299690 · Cited by 9
“in the spin-exchange relaxation-free (SERF) regime [7], [11].”
BackgroundThermal Atomic Compass Based on Radially Polarized Beam
Cai, G., Tian, K., & Wang, Z. (2024) · Laser & Photonics Review · doi:10.1002/lpor.202400465 · Cited by 10
Long Josephson Junction in Ultralow-Noise Magnetometer Configuration
Vettoliere, A., Granata, C., & Monaco, R. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2357473 · Cited by 9
“Among them, it is worth mentioning the optically pumped atomic magnetometers [1] and sensors based on both superconducting transformer and giant magnetoresistance [2].”
BackgroundUltra-low-noise magnetic sensing with long Josephson tunnel junctions
Monaco, R., Granata, C., Russo, R., & Vettoliere, A. (2013) · Superconductor Science and Technology · doi:10.1088/0953-2048/26/12/125005 · Cited by 10
GMR-based sensors for ultra-sensitive magnetometry
Pannetier-Lecoeur, M., Fermon, C., Polovy, H., Dyvorne, H., Sergeeva-Chollet, N., & Paul, J. (2009) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2009.5398408 · Cited by 11
Gusarov, A., Baranga, A. B.-A., Levron, D., & Shuker, R. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaa702 · Cited by 9
Yao, H., Ma, D., Zhao, J., Lu, J., & Ding, M. (2019) · Photonic Sensors · doi:10.1007/s13320-019-0530-4 · Cited by 12
Hilschenz, I., Oh, S., Lee, S.-J., Yu, K. K., Hwang, S.-M., Kim, K., & Shim, J. H. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.06.013 · Cited by 9
“Because the magnetic field used in this work for O-DNP is no higher than a few microtesla, optically-pumped atomic magnetometers[13] can be adopted in direct detection of”
BackgroundZhang, X., Jin, S., Qu, W., & Xiao, Y. (2021) · Applied Physics Letters · doi:10.1063/5.0054842 · Cited by 11
Long‐Range, High‐Resolution Magnetic Imaging of Nanoparticles
Yao, L., & Xu, S. (2009) · Angewandte Chemie · doi:10.1002/ange.200902114 · Cited by 9
Advances in quantum magnetometry for geomagnetic research
Aleksandrov, E. B. (2010) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0180.201005f.0509 · Cited by 9
Oida, T., Tsuchida, M., Takata, H., & Kobayashi, T. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2365011 · Cited by 9
Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises
Chen, X., Zhang, H., & Zou, S. (2016) · Sensors · doi:10.3390/s16060896 · Cited by 9
“After FFT, the output signals were processed by divided a normalized frequency-response function with a fit to A/( f 2 0 + B 2 bandwidth) 1/2, where A is the coefficient, f 0 is the frequency, and Bbandwidth is the bandwidth [17].”
MethodDing, Z., Yuan, J., & Long, X. (2017) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/120/43001 · Cited by 9
Bevington, P., Gartman, R., & Chałupczak, W. (2020) · Physical Review A · doi:10.1103/physreva.101.013436 · Cited by 9
Methods of Parametric Resonance Excitation in the Scheme of an Optical Magnetometric Sensor
Vershovskii, A. K., & Petrenko, M. V. (2021) · Technical Physics · doi:10.1134/s106378422105025x · Cited by 8
Fast measurement of magnetic gradient based on four-channel optically pumped atomic magnetometer
Zhang, Y., Tang, J., Li, C., Zhao, B., Li, L., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114591 · Cited by 9
Modeling and experimental studies of degaussing hysteresis in near-zero magnetic shielding systems
Wang, Z., Li, H., Yang, S., Han, B., Yu, S., & Wen, T. (2024) · Journal of Applied Physics · doi:10.1063/5.0193131 · Cited by 8
Unambiguous measurement in an unshielded microscale magnetometer with sensitivity below 1 pT / Hz
Taylor, H. A. M., Bounds, C. C., Tritt, A., & Turner, L. D. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.024047 · Cited by 11
Optical pump magnetometers parametric correction method based on three-axis coil arrays
Liang, S., Zhu, Y., He, J., Qi, J., Jia, Y., Wang, A., Zhao, T., Wei, C., Jiao, H., Feng, L., et al. (2024) · Measurement · doi:10.1016/j.measurement.2024.115909 · Cited by 10
Akbar, A., Koźbiał, M., Elson, L., Meraki, A., Kołodyński, J., & Jensen, K. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.054033 · Cited by 10
Comprehensive Analysis and Structural Optimization for Single-Ended Open Magnetic Shielding Cylinder
Yuan, L., Cui, P., Zhang, H., Zhao, F., Li, Y., Zhang, L., Zheng, Y., & Yang, Z. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3498011 · Cited by 9
Xie, X., Zhou, X., Zhao, F., Wang, W., Yin, C., & Sun, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117052 · Cited by 8
Hewatt, D. P., Ellmeier, M., Kiehl, C., Menon, T. S., Pollock, J. W., Regal, C. A., & Knappe, S. A. (2025) · Physical Review A · doi:10.1103/physreva.111.033106 · Cited by 9
“However, these hyperfine techniques exhibit limited sensitivity when compared to methods that measure Zeeman resonances.”
Yan, B., Peng, Y., Zhang, Y., Zhang, Y., Zhang, H., Cao, Y., Sun, C. K., & Ding, M. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121262 · Cited by 8
“Studies have shown that OPM sensors possess sensitivity levels comparable to those of SQUID sensors (Dang et al., 2010; Kominis et al., 2003; Shah and Wakai, 2013) and have demonstrated their feasibility for various biomagnetic applications, including MEG (Broser et al., 2021; Liang et al., 2024;…”
Evanescent wave magnetometers with ultrathin (∼100μm) cells
Zhao, K., & Wu, Z. (2008) · Applied Physics Letters · doi:10.1063/1.2966153 · Cited by 8
Experimental optimization of atomic magnetometer in nuclear magnetic resonance gyroscope
Zhang, K., Luo, Z., Tang, F., Zhao, N., & Wang, Y. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab6caf · Cited by 9
Ohkubo, M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0167372 · Cited by 9
Real-Time Localization of OPMs in a Flexible Array During MEG Recordings
Gu, W., He, K., Ma, X., Li, D., Pang, W., Sheng, J., & Gao, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3346516 · Cited by 9
“Recently, optically pumped magnetometers (OPMs) have been developed for measuring neural magnetic fields [7], [8], opening up possibilities for a new generation of MEG, which is hereinafter referred to as OPM-MEG.”
BackgroundLu, Y., Liu, J., Jiang, H., & Liao, Z. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad3f46 · Cited by 8
“For instance, reducing the linewidth of resonant systems enables to detect weak signals and achieves better measurement sensitivity for precision sensing in experiments [23–28].”
BackgroundMaximum distance estimation of far-field model for underwater magnetic field communication
Zhou, J., & Chen, J. (2017) · IEEE Annual Computing and Communication Workshop and Conference (CCWC) · doi:10.1109/ccwc.2017.7868371 · Cited by 8
“The minimum detectable signal strength min S of the atomic magnetometer can be 6 1 10 nT − × currently [16].”
BackgroundJi, Y., Gan, Q., Wu, L., & Shang, J. (2017) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2017.7863411 · Cited by 8
“6, magnetic field noise[16] at different temperatures ranging”
BackgroundSilva, M., Silva, J. F., Leitão, D. C., Cardoso, S., & Freitas, P. P. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2899808 · Cited by 8
“The portfolio of the state-of-the-art low magnetic field detection includes the well-known quantum interference devices (SQUID) [1], atomic magnetometers (AMs) [2], spin-exchange relaxation-free (SERF) AMs [3], and more recently, optical AMs (OPMs) based on magnetooptical properties of atomic samples [4], [5].”
BackgroundFu, Y.-Y., & Yuan, J. (2019) · Chinese Physics B · doi:10.1088/1674-1056/ab3442 · Cited by 8
Magnetic shielding property for cylinder with circular, square, and equilateral triangle holes*
Hao, S.-Y., Lou, X., Zhu, J., Chen, G., & Li, H. (2021) · Chinese Physics B · doi:10.1088/1674-1056/abeeee · Cited by 8
Cavity-enhanced magnetometer with a spinor Bose–Einstein condensate
Gietka, K., Mivehvar, F., & Busch, T. (2021) · New Journal of Physics · doi:10.1088/1367-2630/abedff · Cited by 10
Taulu, S., Simola, J., Nenonen, J., & Parkkonen, L. T. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_2 · Cited by 10
Ma, Y., Lu, J., Yang, K., Wang, Z., Wang, Y., Sun, B., Zhai, Y., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3207824 · Cited by 9
Yu, M., Chen, Y., Wang, Y., Ma, Y., Luo, G., Lu, S., Zhao, L., Yang, P., Lin, Q., & Jiang, Z. (2023) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2023.10.029 · Cited by 8
Lei, G., Yuan, Z., Yue, Z., Xu, S., & Zhai, Y. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202300391 · Cited by 12
Single ion as a shot-noise-limited magnetic-field-gradient probe
Walther, A., Poschinger, U., Ziesel, F., Hettrich, M., Wiens, A., Welzel, J., & Schmidt‐Kaler, F. (2011) · Physical Review A · doi:10.1103/physreva.83.062329 · Cited by 11
Sacrificial microchannel sealing by glass‐frit reflow for chip scale atomic magnetometer
Tsujimoto, K., Hirai, Y., Sugano, K., Tsuchiya, T., & Tabata, O. (2013) · Electronics and Communications in Japan · doi:10.1002/ecj.10432 · Cited by 8
“Atomic MEMS (Micro Electro Mechanical Systems) is an emerging multidisciplinary application, which includes not only chip-scale atomic clocks but also CSAMs (Chip Scale Atomic Magnetometers) [1] with high sensitivity and low cost applicable for wide range of applications such as geophysical exploration, navigation and…”
Background
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.