A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 201–300 of 1,000
Microfabricated atomic clocks and magnetometers
Knappe, S. A., Schwindt, P. D. D., Gerginov, V. P., Shah, V., Liew, L., Moreland, J., Robinson, H. G., Hollberg, L. W., & Kitching, J. E. (2006) · Journal of Optics A Pure and Applied Optics · doi:10.1088/1464-4258/8/7/s04 · Cited by 69
High-Resolution Zero-Field NMR J-Spectroscopy of Aromatic Compounds
Blanchard, J. W., Ledbetter, M. P., Theis, T., Butler, M. C., Budker, D., & Pines, A. (2013) · Journal of the American Chemical Society · doi:10.1021/ja312239v · Cited by 76
Jäger, J. V., Scherbakov, A. V., Glavin, B. A., Salasyuk, A. S., Campion, R. P., Rushforth, A. W., Yakovlev, D. R., Akimov, A. V., & Bayer, M. (2015) · Physical Review B · doi:10.1103/physrevb.92.020404 · Cited by 69
“The continual miniaturization of magnetic devices down to the nanometer scale has opened new horizons in data storage [1], computing [2,3], sensing [4,5], and medical technologies [6].”
BackgroundAn Optically Pumped Magnetometer Working in the Light-Shift Dispersed Mz Mode
Schultze, V., Schillig, B., IJsselsteijn, R. P. J., Scholtes, T., Woetzel, S., & Stolz, R. (2017) · Sensors · doi:10.3390/s17030561 · Cited by 76
“[28], is the SERF magnetometer (SERF = spin-exchange relaxation-free), where very high atomic density n is combined with very low ambient magnetic field magnitude B0.”
BackgroundMagnetic relaxometry with an atomic magnetometer and SQUID sensors on targeted cancer cells
Johnson, C., Adolphi, N. L., Butler, K. S., Lovato, D. M., Larson, R., Schwindt, P. D. D., & Flynn, E. R. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2012.03.015 · Cited by 79
“Most notable are giant magnetoresistive (GMR) [13], vibrating sample magnetometers [14], SQUID sensors [15], and atomic magnetometers (AM) [16, 17].”
InfluentialZhao, J., Ding, M., Lu, J., Yang, K., Ma, D., Yao, H., Han, B., & Liu, G. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2905308 · Cited by 70
“Typically, an SERF magnetometer operates at nearly zero-magnetic field below 10 nT and high density of alkali atoms with a number density of 1013 cm−3–1014 cm−3 [14], [15], which causes a large optical depth of the vapor cell.”
Suppression of the Bias Error Induced by Magnetic Noise in a Spin-Exchange Relaxation-Free Gyroscope
Fan, W., Quan, W., Liu, F., Li, X., & Liu, G. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2929505 · Cited by 67
“Quantum sensors with high sensitivity have found a wide range of important applications, such as magnetic and electric fields [2], [3], time and frequency [4]–[6], rotations [7]–[9], temperature [10], and so on.”
BackgroundJia, F.-D., Liu, X., Mei, J., Yu, Y., Zhang, H., Lin, Z.-Q., Dong, H.-Y., Zhang, J., Xie, F., & Zhong, Z.-P. (2021) · Physical Review A · doi:10.1103/physreva.103.063113 · Cited by 70
Detection of radio-frequency magnetic fields using nonlinear magneto-optical rotation
Ledbetter, M. P., Acosta, V. M., Rochester, S., Budker, D., Pustelny, S., & Yashchuk, V. V. (2007) · Physical Review A · doi:10.1103/physreva.75.023405 · Cited by 67
Kinetic inductance magnetometer
Luomahaara, J., Vesterinen, V., Grönberg, L., & Hassel, J. (2014) · Nature Communications · doi:10.1038/ncomms5872 · Cited by 74
Fourcault, W., Romain, R., Le Gal, G., Bertrand, F., Josselin, V., Le Prado, M., Labyt, E., & Palacios-Laloy, A. (2021) · Optics Express · doi:10.1364/oe.420031 · Cited by 65
MEMS Components for NMR Atomic Sensors
Noor, R. M., & Shkel, A. M. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2874451 · Cited by 68
“For example, in table-top setups, an atomic magnetometer can measure magnetic fields with a sensitivity of 1 f T/ √ H z [3], and an atomic gyroscope can measure rotation with an Angle Random Walk (ARW) of 0.”
MethodSuperconducting sensors and methods in geophysical applications
Stolz, R., Schmelz, M., Zakosarenko, V., Foley, C., Tanabe, K., Xie, X., & Fagaly, R. L. (2021) · Superconductor Science and Technology · doi:10.1088/1361-6668/abd7ce · Cited by 82
Widefield microwave imaging in alkali vapor cells with sub-100μm resolution
Horsley, A., Du, G.-X., & Treutlein, P. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/11/112002 · Cited by 77
“Atomic vapor cells are one of the most versatile systems for measuring electromagnetic fields [1–3], and are at the heart of the most sensitive dc [4, 5] and rf [6, 7] magnetometers.”
BackgroundJensen, K., Budvytyte, R., Thomas, R. A., Wang, T., Fuchs, A. M., Balabas, M. V., Vasilakis, G., Mosgaard, L. D., Stærkind, H. C., Müller, J. H., et al. (2016) · Scientific Reports · doi:10.1038/srep29638 · Cited by 64
“For example, femtoTesla sensitivity has been achieved with magnetometers operating at a temperature of several hundred of ◦C in the so-called SERF regime [3] used also for medical applications [4–6].”
Para-hydrogen perspectives in hyperpolarized NMR
Glöggler, S., Colell, J. F. P., & Appelt, S. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.07.010 · Cited by 65
He, K., Wan, S., Sheng, J., Liu, D., Wang, C., Li, D., Qin, L., Luo, S., Qin, J., & Gao, J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5066250 · Cited by 71
Castagna, N., Bison, G., Domenico, G. D., Hofer, A., Knowles, P., Macchione, C., Saudan, H., & Weis, A. (2009) · reroDoc Digital Library · Cited by 64
Transforming and comparing data between standard SQUID and OPM-MEG systems
Marhl, U., Jodko-Władzińska, A., Brühl, R., Sander, T. H., & Jazbinšek, V. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262669 · Cited by 70
“Following miniaturization [5, 6], a new type of magnetometer, the optically-pumped magnetometer (OPM), was introduced to MEG [7, 8].”
MethodInfluentialSeltzer, S. J., Michalak, D. J., Donaldson, M. H., Balabas, M. V., Barber, S., Bernasek, S. L., Bouchiat, M.-A., Hexemer, A., Hibberd, A. M., Kimball, D. F. J., et al. (2010) · The Journal of Chemical Physics · doi:10.1063/1.3489922 · Cited by 76
Chemical analysis using J-coupling multiplets in zero-field NMR
Theis, T., Blanchard, J. W., Butler, M. C., Ledbetter, M. P., Budker, D., & Pines, A. (2013) · Chemical Physics Letters · doi:10.1016/j.cplett.2013.06.042 · Cited by 62
Long, T., Song, X., Han, B., Suo, Y., & Jia, L. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3331425 · Cited by 84
“Allred et al. [16] and Kominis et al. [17] first proposed highly sensitive optically pumped magnetometers (OPMs) in the SERF regime and achieved a measurement sensitivity of 0.54 fT/Hz 1 / 2 .”
BackgroundInfluentialSingle-Beam Atomic Magnetometer Based on the Transverse Magnetic-Modulation or DC-Offset
Liu, G., Tang, J., Yin, Y., Wang, Y., Zhou, B., & Han, B. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2973201 · Cited by 64
“Among this, the socalled SERF magnetometer exhibited the highest sensitivity (theoretically, 10 aT/Hz1/2), and it has the potential for a further improvement by one order of magnitude [3], [6].”
BackgroundSuppression of Spin Projection Noise in Broadband Atomic Magnetometry
Geremia, J. M., Stockton, J. K., & Mabuchi, H. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.203002 · Cited by 62
Fang, X., Wei, K., Zhai, Y., Zhao, T., Chen, X., Zhou, M., Liu, Y., Ma, D., & Xiao, Z. (2022) · Optics Express · doi:10.1364/oe.447041 · Cited by 64
Precisely mapping the magnetic field gradient in vacuum with an atom interferometer
Zhou, M.-K., Hu, Z.-K., Duan, X., Sun, B.-L., Zhao, J., & Luo, J. (2010) · Physical Review A · doi:10.1103/physreva.82.061602 · Cited by 61
Limits on Anomalous Spin-Spin Couplings between Neutrons
Glenday, A. G., Cramer, C. E., Phillips, D. F., & Walsworth, R. L. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.261801 · Cited by 70
Ultra-sensitive Magnetic Microscopy with an Optically Pumped Magnetometer
Kim, Y. J., & Savukov, I. (2016) · Scientific Reports · doi:10.1038/srep24773 · Cited by 67
Low helium permeation cells for atomic microsystems technology
Dellis, A. T., Shah, V., Donley, E. A., Knappe, S. A., & Kitching, J. E. (2016) · Optics Letters · doi:10.1364/ol.41.002775 · Cited by 60
Signal Tracking Beyond the Time Resolution of an Atomic Sensor by Kalman Filtering
Jiménez-Martínez, R., Kołodyński, J., Troullinou, C., Lucivero, V. G., Kong, J., & Mitchell, M. W. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.040503 · Cited by 64
Comparison of discharge lamp and laser pumped cesium magnetometers
Groeger, S., Pazgalev, A. S., & Weis, A. (2005) · Applied Physics B · doi:10.1007/s00340-005-1773-x · Cited by 60
Ru, X., He, K., Lyu, B., Li, D., Xu, W., Gu, W., Ma, X., Liu, J., Li, C., Li, T., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119420 · Cited by 59
Katsoprinakis, G. E., Dellis, A. T., & Kominis, I. K. (2007) · Physical Review A · doi:10.1103/physreva.75.042502 · Cited by 61
Self-citationExternal high-quality-factor resonator tunes up nuclear magnetic resonance
Suefke, M., Liebisch, A., Blümich, B., & Appelt, S. (2015) · Nature Physics · doi:10.1038/nphys3382 · Cited by 57
Proposed Robust Entanglement-Based Magnetic Field Sensor Beyond the Standard Quantum Limit
Tanaka, T., Knott, P. A., Matsuzaki, Y., Dooley, S., Yamaguchi, H., Munro, W. J., & Saito, S. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.170801 · Cited by 70
Testing the effect of surface coatings on alkali atom polarization lifetimes
Seltzer, S. J., Rampulla, D. M., Rivillon, S., Chabal, Y. J., Bernasek, S. L., & Romalis, M. V. (2008) · Journal of Applied Physics · doi:10.1063/1.2985913 · Cited by 63
Self-citationRobust, high-speed, all-optical atomic magnetometer
Higbie, J. M., Corsini, E., & Budker, D. (2006) · Review of Scientific Instruments · doi:10.1063/1.2370597 · Cited by 67
Zhang, C., Yuan, H., Tang, Z., Quan, W., & Fang, J. (2016) · Applied Physics Reviews · doi:10.1063/1.4972187 · Cited by 60
Jeske, J., Cole, J. H., & Greentree, A. D. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/1/013015 · Cited by 73
Recent Progress of Atomic Magnetometers for Geomagnetic Applications
Lu, Y., Zhao, T., Zhu, W., Liu, L., Zhuang, X., Fang, G., & Zhang, X. (2023) · Sensors · doi:10.3390/s23115318 · Cited by 71
“Due to the interaction of the external magnetic field, pumping light, and various relaxation mechanisms in the cell, the equation of evolution for the atomic ground-state can be described by the Bloch equation [57]:”
BackgroundXu, S., Crawford, C. W., Rochester, S., Yashchuk, V. V., Budker, D., & Pines, A. (2008) · Physical Review A · doi:10.1103/physreva.78.013404 · Cited by 56
Nonlinear magneto-optical rotation with modulated light in tilted magnetic fields
Pustelny, S., Gawlik, W., Rochester, S., Kimball, D. F. J., Yashchuk, V. V., & Budker, D. (2006) · Physical Review A · doi:10.1103/physreva.74.063420 · Cited by 56
Requirements for Coregistration Accuracy in On-Scalp MEG
Zetter, R., Iivanainen, J., Stenroos, M., & Parkkonen, L. (2018) · Brain Topography · doi:10.1007/s10548-018-0656-5 · Cited by 56
“SERF OPMs with sensitivities better than have been demonstrated (Kominis et al., 2003; Griffith et al., 2010; Colombo et al., 2016; Knappe et al., 2016).”
Flux-Gate Magnetometers Design Peculiarities
Korepanov, V. E., & Marusenkov, A. (2012) · Surveys in Geophysics · doi:10.1007/s10712-012-9197-8 · Cited by 55
“While the first measurements of the Earth’s magnetic field were made with devices having a sensitivity threshold of about several tens of nanoTesla, the designers of magnetometers today have refined their resolution to the attoTesla level (Kominis et al. 2003).”
BackgroundBlanchard, J. W., Sjolander, T. F., King, J. P., Ledbetter, M. P., Levine, E. H., Bajaj, V. S., Budker, D., & Pines, A. (2015) · Physical Review B · doi:10.1103/physrevb.92.220202 · Cited by 61
Spin-exchange relaxation-free magnetometer with nearly parallel pump and probe beams
Karaulanov, T. S., Savukov, I., & Kim, Y. J. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/5/055002 · Cited by 62
Human MCG measurements with a high-sensitivity potassium atomic magnetometer
Kamada, K., Ito, Y., & Kobayashi, T. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/6/1063 · Cited by 57
Magnetic Gradiometer for the Detection of Zero- to Ultralow-Field Nuclear Magnetic Resonance
Jiang, M., Picazo‐Frutos, R., Wu, T., Blanchard, J. W., Peng, X., & Budker, D. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.024005 · Cited by 53
Mikhailov, E. E., Horrom, T., Belcher, N., & Novikova, I. V. (2010) · Journal of the Optical Society of America B · doi:10.1364/josab.27.000417 · Cited by 55
Ito, Y., Ohnishi, H., Kamada, K., & Kobayashi, T. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2148191 · Cited by 54
“The value was not good compared to that reported by the Romalis group with the SERF magnetometer [2] using potassium, which has lower spin-destruction cross section than rubidium, as the probe atoms.”
ResultZhang, C., Yuan, H., Zhang, N., Xu, L., Zhang, J., Li, B., & Fang, J. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aab2d0 · Cited by 58
Voltage-driven, local, and efficient excitation of nitrogen-vacancy centers in diamond.
Labanowski, D., Bhallamudi, V. P., Guo, Q., Purser, C. M., McCullian, B., Hammel, P. C., & Salahuddin, S. (2018) · eScholarship (California Digital Library) · Cited by 52
Xu, S., Rochester, S., Yashchuk, V. V., Donaldson, M. H., & Budker, D. (2006) · Review of Scientific Instruments · doi:10.1063/1.2336087 · Cited by 53
Gangopadhyay, P., Voorakaranam, R., Lopez-Santiago, A., Foerier, S., Thomas, J., Norwood, R. A., Persoons, A. P., & Peyghambarian, N. N. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp800829h · Cited by 52
Jeske, J., Cole, J. H., & Greentree, A. D. (2022) · Figshare · Cited by 52
Optimal Operating Temperature of Miniaturized Optically Pumped Magnetometers
Zhang, S., Lu, J., Ye, M., Zhou, Y., Yin, K., Lu, F., Yan, Y., & Zhai, Y. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3147901 · Cited by 58
Schultze, V., IJsselsteijn, R. P. J., Scholtes, T., Woetzel, S., & Meyer, H. (2012) · Optics Express · doi:10.1364/oe.20.014201 · Cited by 55
An optically modulated zero-field atomic magnetometer with suppressed spin-exchange broadening
Jiménez-Martínez, R., Knappe, S. A., & Kitching, J. E. (2014) · Review of Scientific Instruments · doi:10.1063/1.4872075 · Cited by 49
Fang, J., Chen, Y., Zou, S., Liu, X., Hu, Z., Quan, W., Yuan, H., & Ding, M. (2016) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/49/6/065006 · Cited by 49
Magneto-optic Properties of Regioregular Polyalkylthiophenes
Gangopadhyay, P., Koeckelberghs, G., & Persoons, A. P. (2010) · Chemistry of Materials · doi:10.1021/cm102215a · Cited by 51
Magnetic Source Imaging Using a Pulsed Optically Pumped Magnetometer Array
Borna, A., Carter, T. R., DeRego, P., James, C. D., & Schwindt, P. D. D. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2851458 · Cited by 54
“Recently, OPMs operating in the spin-exchange-relaxationfree (SERF) regime have shown sub-fT sensitivity [19], and have been used to localize neuronal current sources within the human brain [20], [21].”
Zou, S., Zhang, H., Chen, X.-Y., & Fang, J. (2021) · Measurement · doi:10.1016/j.measurement.2021.110338 · Cited by 52
Ito, Y., Ohnishi, H., Kamada, K., & Kobayashi, T. (2012) · AIP Advances · doi:10.1063/1.4742847 · Cited by 53
Kim, Y. J., Chu, P.-H., & Savukov, I. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.091802 · Cited by 67
Sources of heading errors in optically pumped magnetometers operated in the Earth's magnetic field
Oelsner, G., Schultze, V., IJsselsteijn, R. P. J., Wittkämper, F., & Stolz, R. (2019) · Physical Review A · doi:10.1103/physreva.99.013420 · Cited by 54
Femtotesla Nearly-Quantum-Noise-Limited Pulsed Gradiometer at Earth-Scale Fields
Lucivero, V. G., Lee, W., Limes, M. E., Foley, E. L., Kornack, T. W., & Romalis, M. V. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.l021001 · Cited by 60
Self-citationProbing fundamental physics with spin-based quantum sensors
Kimball, D. F. J., Budker, D., Chupp, T. E., Geraci, A. A., Kolkowitz, S., Singh, J. T., & Sushkov, A. O. (2023) · Physical Review A · doi:10.1103/physreva.108.010101 · Cited by 57
Shot-noise-limited magnetometer with sub-picotesla sensitivity at room temperature
Lucivero, V. G., Anielski, P., Gawlik, W., & Mitchell, M. W. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901588 · Cited by 55
Suppression of Spin-Exchange Relaxation Using Pulsed Parametric Resonance
Korver, A., Wyllie, R., Lancor, B., & Walker, T. G. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.043002 · Cited by 50
Roadmap on quantum optical systems
Dumke, R., Lu, Z. H., Close, J. D., Robins, N. P., Weis, A., Mukherjee, M., Birkl, G., Hufnagel, C., Amico, L., Boshier, M. G., et al. (2016) · Journal of Optics · doi:10.1088/2040-8978/18/9/093001 · Cited by 58
From LASER physics to the para-hydrogen pumped RASER
Appelt, S., Kentner, A., Lehmkuhl, S., & Blümich, B. (2019) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2019.05.003 · Cited by 50
Zhao, J., Liu, G., Lu, J., Ding, M., Ma, Y., Ji, J., Yang, K., Ma, D., Xing, B., Zhang, N., et al. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abc89c · Cited by 49
“Optically pumped high-density alkali metal vapor is of significant interest because of its widespread applications in many areas, including in fundamental physics research [1], nuclear magnetic resonance gyroscopes [2], atomic comagnetometers [3] and scalar and vector atomic magnetometers [4, 5].”
BackgroundSpin-echo-based magnetometry with spinor Bose-Einstein condensates
Eto, Y., Ikeda, H., Suzuki, H., Hasegawa, S., 富山, 泰., Sekine, S., Sadgrove, M., & Hirano, T. (2013) · Physical Review A · doi:10.1103/physreva.88.031602 · Cited by 49
Non-invasive current density imaging of lithium-ion batteries
Bason, M. G., Coussens, T., Withers, M., Abel, C., Kendall, G. D., & Krüger, P. (2022) · Journal of Power Sources · doi:10.1016/j.jpowsour.2022.231312 · Cited by 54
Xiao, W., Liu, M., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.143201 · Cited by 53
“As one of the most sensitive cryo-gen-free sensors for measuring magnetic fields, atomic magnetometers can achieve a sensitivity of sub-fT = Hz 1 = 2 [20 – 22], and they have been adopted to search for various exotic physics, such as spin-gravity interactions [23 – 25] and dark matter [26].”
BackgroundQuantum magnetic gradiometer with entangled twin light beams
Wu, S., Bao, G., Guo, J., Chen, J., Du, W., Shi, M., Yang, P., Chen, L. Q., & Zhang, W. (2023) · Science Advances · doi:10.1126/sciadv.adg1760 · Cited by 60
Atomic magnetometers and their application in industry
Bai, X., Wen, K., Peng, D., Liu, S., & Luo, L. (2023) · Frontiers in Physics · doi:10.3389/fphy.2023.1212368 · Cited by 59
“54 fT/Hz, and the expected theoretical sensitivity could reach 1 aT/Hz, surpassing the superconductor’s highest sensitivity ever [42].”
BackgroundDiamond quantum sensors: from physics to applications on condensed matter research
Ho, K. O., Shen, Y., Pang, Y. Y., Leung, W. K., Zhao, N., & Yang, S. (2021) · Functional Diamond · doi:10.1080/26941112.2021.1964926 · Cited by 58
“For example, neutral atoms like cold atoms [1] and atomic vapours [2] as magnetometer; trapped ions [3] and Rydberg atoms [4] for electric fields; superconducting quantum interference device (SQUID) as the most sensitive magnetometer; atomic-scale defects in crystals like nitrogen vacancy (NV) colour centres and so on.”
BackgroundCui, Y., Jia, F.-D., Hao, J., Wang, Y., Zhou, F., Liu, X., Yu, Y., Mei, J., Bai, J.-H., Bao, Y.-Y., et al. (2023) · Physical Review A · doi:10.1103/physreva.107.043102 · Cited by 48
Taue, S., Sugihara, Y., Kobayashi, T., Ichihara, S., Ishikawa, K., & Mizutani, N. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2048576 · Cited by 51
“In recent years, several optically pumped atomic magnetometers operating under spin-exchange relaxation-free (SERF) conditions have reached sensitivities in the femtotesla range [2]–[5].”
BackgroundMethodHybrid GMR Sensor Detecting 950 pT/sqrt(Hz) at 1 Hz and Room Temperature
Guedes, A. F. S., Macedo, R. J., Jaramillo, G., Cardoso, S., Freitas, P. P., & Horsley, D. A. (2018) · Sensors · doi:10.3390/s18030790 · Cited by 47
“54 fT/Hz1/2 (in the range of 28–45 Hz) was demonstrated [6].”
BackgroundAbsolute Magnetometry with He3
Farooq, M., Chupp, T. E., Grange, J., Tewsley-Booth, A. E., Flay, D., Kawall, D., Sachdeva, N., & WINTER, P. M. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.223001 · Cited by 54
Fang, X., Wei, K., Zhao, T., Zhai, Y., Ma, D., Xing, B., Liu, Y., & Xiao, Z. (2020) · Optics Express · doi:10.1364/oe.398540 · Cited by 49
Cobalt ferrite nanoparticles polymer composites based all-optical magnetometer
Lopez-Santiago, A., Grant, H. R., Gangopadhyay, P., Voorakaranam, R., Norwood, R. A., & Peyghambarian, N. N. (2012) · Optical Materials Express · doi:10.1364/ome.2.000978 · Cited by 46
An unshielded radio-frequency atomic magnetometer with sub-femtoTesla sensitivity
Keder, D. A., Prescott, D. W., Conovaloff, A., & Sauer, K. L. (2014) · AIP Advances · doi:10.1063/1.4905449 · Cited by 52
Single-quadrature quantum magnetometry in cavity electromagnonics
Ebrahimi, M. S., Motazedifard, A., & Harouni, M. B. (2021) · Physical Review A · doi:10.1103/physreva.103.062605 · Cited by 50
Colloquium: Coherent diffusion of polaritons in atomic media
Firstenberg, O., Shuker, M., Ron, A., & Davidson, N. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.941 · Cited by 53
“This field of research is largely motivated by applications, namely, high-precision measurements, especially with spatial multi-pixel resolution (Kominis et al., 2003); multi-mode quantum memories (Vasilyev et al., 2010); and spatial information processing, either classical or quantum (Marino et…”
MethodCooper, R. J., Prescott, D. W., Matz, P., Sauer, K. L., Dural, N., Romalis, M. V., Foley, E. L., Kornack, T. W., Monti, M. C., & Okamitsu, J. (2016) · Physical Review Applied · doi:10.1103/physrevapplied.6.064014 · Cited by 47
“devices (SQUIDs) [18] and atomic magnetometers rival one another for better sensitivity [11,17,19].”
BackgroundSelf-citationDemonstration of high-performance compact magnetic shields for chip-scale atomic devices
Donley, E. A., Hodby, E., Hollberg, L. W., & Kitching, J. E. (2007) · Review of Scientific Instruments · doi:10.1063/1.2767533 · Cited by 45
Zhang, R., Mhaskar, R., Smith, K., & Prouty, M. (2020) · Applied Physics Letters · doi:10.1063/5.0004746 · Cited by 48
“Sensitivities comparable with [2] or even outperforming [3] those of superconducting quantum interference devices (SQUIDs) have been reported with SERF magnetometers.”
BackgroundMagnetic-field-dependent stimulated emission from nitrogen-vacancy centers in diamond
Hahl, F. A., Lindner, L., Vidal, X., Luo, T., Ohshima, T., Onoda, S., Ishii, S., Zaitsev, A. M., Capelli, M., Gibson, B. C., et al. (2022) · Science Advances · doi:10.1126/sciadv.abn7192 · Cited by 50
Compact multi-channel optically pumped magnetometer for bio-magnetic field imaging
Yuan, Z., Liu, Y., Xiang, M., Gao, Y., Suo, Y., Ye, M., & Zhai, Y. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.109534 · Cited by 45
Collective uncertainty in partially polarized and partially decohered spin- 12 systems
Baragiola, B. Q., Chase, B. A., & Geremia, J. M. (2010) · Physical Review A · doi:10.1103/physreva.81.032104 · Cited by 44
High-sensitivity magnetometry with a single atom in a superposition of two circular Rydberg states
Dietsche, E.-K., Larrouy, A., Haroche, S., Raimond, J. M., Brune, M., & Gleyzes, S. (2019) · Nature Physics · doi:10.1038/s41567-018-0405-4 · Cited by 60
Pratt, E. J., Ledbetter, M. P., Jiménez-Martínez, R., Shapiro, B., Solon, A. J., Iwata, G. Z., Garber, S., Gormley, J., Decker, D., Delgadillo, D., et al. (2021) · Optical and Quantum Sensing and Precision Metrology · doi:10.1117/12.2581794 · Cited by 51
Zektzer, R., Mazurski, N., Barash, Y., & Levy, U. (2021) · Nature Photonics · doi:10.1038/s41566-021-00853-4 · Cited by 46
Liu, X., Jia, F.-D., Zhang, H., Mei, J., Yu, Y., Liang, W.-C., Zhang, J., Xie, F., & Zhong, Z.-P. (2021) · AIP Advances · doi:10.1063/5.0054027 · Cited by 45
Modern radio-optical methods in quantum magnetometry
Aleksandrov, E. B., & Vershovskii, A. K. (2009) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0179.200906f.0605 · Cited by 44
High resolution magnetic vector-field imaging with cold atomic ensembles
Koschorreck, M., Napolitano, M., Dubost, B., & Mitchell, M. W. (2011) · Applied Physics Letters · doi:10.1063/1.3555459 · Cited by 43
Kamada, K., Ito, Y., Ichihara, S., Mizutani, N., & Kobayashi, T. (2015) · Optics Express · doi:10.1364/oe.23.006976 · Cited by 43
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.