A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 901–1,000 of 1,000
A laser pump-re-pump atomic magnetometer
Yang, A., Yang, G., Cai, X., Xu, Y., & Lin, Q. (2013) · Chinese Physics B · doi:10.1088/1674-1056/22/12/120702 · Cited by 8
Mironov, A. E., Hewitt, J. D., & Eden, J. G. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.113201 · Cited by 8
Chałupczak, W., Godun, R. M., & Pustelny, S. (2018) · Advances in atomic, molecular, and optical physics · doi:10.1016/bs.aamop.2018.03.001 · Cited by 8
In situ determination of alkali metal density using phase-frequency analysis on atomic magnetometers
Yao, H., Zhang, H., Ma, D., Zhao, J., & Ding, M. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aad1e0 · Cited by 8
Precision measurement of the light shift of Mg+25 ions
Yuan, W. H., Deng, K., Ma, Z. Y., Che, H., Xu, Z., Liu, H.-X., Zhang, J., & Lu, Z. H. (2018) · Physical Review A · doi:10.1103/physreva.98.052507 · Cited by 8
Hämäläinen, M., & Lundqvist, D. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_81 · Cited by 11
Static weak magnetic field measurements based on low-field nuclear magnetic resonance
Wang, X., Zhu, M., Xiao, K., Guo, J., & Wang, L. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106580 · Cited by 8
Measuring magnetic field vector by stimulated Raman transitions
Wang, W., Dong, R., Wei, R., Lin, J., Zou, F., Chen, T., & Wang, Y. (2016) · Applied Physics Letters · doi:10.1063/1.4944700 · Cited by 8
Electromagnetic characteristics of ENSO
Petereit, J., Saynisch‐Wagner, J., Irrgang, C., Weber, T., & Thomas, M. (2018) · Ocean science · doi:10.5194/os-14-515-2018 · Cited by 8
Cold, optically dense gases of atomic rubidium
Magkiriadou, S., Patterson, D., Nicolas, T., & Doyle, J. M. (2011) · New Journal of Physics · doi:10.1088/1367-2630/13/2/023012 · Cited by 7
MICROFABRICATED ATOMIC CLOCKS AND MAGNETOMETERS
Knappe, S. A., Schwindt, P. D. D., Gerginov, V. P., Shah, V., Robinson, H. G., Hollberg, L. W., & Kitching, J. E. (2005) · Laser Spectroscopy · doi:10.1142/9789812701473_0035 · Cited by 8
Low-frequency characterization of MEMS-based portable atomic magnetometer
Mhaskar, R. R., Knappe, S. A., & Kitching, J. E. (2010) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2010.5556307 · Cited by 8
All-optical self-oscillating 4He atomic mangnetometer with optical phase shift
Wang, H., Wu, T., Wang, H., Liu, Y., Mao, X., Peng, X., & Guo, H. (2020) · Optics Express · doi:10.1364/oe.390375 · Cited by 7
Wang, H., Wang, S., Li, B., Qian, Y., & Lu, J. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107070 · Cited by 8
Wall-collision effect on optically polarized atoms in small and hot vapor cells
Chang, Y., & Qin, J. (2024) · Physical Review A · doi:10.1103/physreva.109.023113 · Cited by 8
Removal mechanism of double-diamond-abrasive-grinding GaN single crystals under graphene lubrication
Xu, M., Gao, T., Li, L., Wang, B., Chen, Q., Huang, J. G., & Xiao, Q. (2024) · Diamond and Related Materials · doi:10.1016/j.diamond.2024.111381 · Cited by 7
Zheng, F., Li, C., Li, D., Xu, W., Ru, X., Cheng, H., Liu, Z., Na, S., Qin, L., Lyu, B., et al. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3435882 · Cited by 8
“Spin-exchange relaxation-free (SERF) magnetometers, a type of OPM, have shown unparalleled sensitivity [15], [16], [17].”
BackgroundShao, Q., Jiang, L., Zou, Y., Zhao, X. H., Zhu, J., Fang, C., Xiang, M., Lei, X., & Quan, W. (2024) · Measurement · doi:10.1016/j.measurement.2024.115734 · Cited by 7
Effect of Optical Nonorthogonality on Dynamic Response in Dual-Beam Atomic Magnetometer
Xing, B., Li, S., Fang, X., Lu, H., & Ma, D. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3502819 · Cited by 7
“In the SERF magnetometer, the dynamic responses are used to calculate the sensitivity [18], determine polarization [19], [20], and measure relaxation rate [21], [22].”
Compact and High-Sensitivity Bismuth-Doped Silica Optical Fiber Weak Magnetic Sensor
Huang, C., Dong, Y., Huang, Y., Wang, W., Wang, W., Chen, M., Wen, J., Zhang, X., Luo, Y., & Wang, T. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3520606 · Cited by 7
“D UE to the application of advanced magnetic sensing technologies in various fields such as medical diagnostics [1], industrial monitoring [2], and environmental sensing [3], [4], the demand for these technologies has significantly increased.”
High-Sensitivity, Microfabricated Quantum Magnetometers With an Intelligent Solar Heating System
Ma, Y., Chen, Y., Yu, M., Yanbin, W., Guo, J., Zhao, M., Yang, P., Lin, Q., & Zhao, L. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3519377 · Cited by 10
“E MERGING quantum sensors based on thermal atomic ensembles, such as atomic magnetometers [1], [2], atomic clocks [3], [4], atomic co-magnetometers [5], [6], etc., have attracted widespread interest owing to the unprecedented measurement accuracy and sensitivity.”
Enhancing Quantum Metrology by Quantum Resonance Dynamics
Zou, Z., Gong, J., & Chen, W. (2025) · Physical Review Letters · doi:10.1103/lkrt-lvng · Cited by 16
Trapped-ion based nanoscale quantum sensing
Yoo, J., Kim, H., Kim, H., Kim, Y. J., & Choi, T. (2025) · Nano Convergence · doi:10.1186/s40580-025-00479-0 · Cited by 12
Magnetic-field-independent spin-exchange relaxation-free magnetometer
Dikopoltsev, M., Levy, U., & Katz, O. (2025) · Physical Review A · doi:10.1103/physreva.111.032602 · Cited by 9
Preliminary study on the conceptual design and development of diagnostics for the CFEDR
Liu, H., Li, G., 杨, Y. 曜. Y., Zhang, T., 兰, T. 婷. L., Lian, H., 洪, B. 博. H., & Ding, R. (2025) · Plasma Science and Technology · doi:10.1088/2058-6272/ade659 · Cited by 7
Heterodyne Detection of Low-Frequency Fields via Rydberg EIT with Phase Demodulation
Jin, S., Fan, X., Wang, X., Song, Y., & Sun, Y. (2025) · Chinese Physics Letters · doi:10.1088/0256-307x/42/11/110304 · Cited by 16
Wang, F., Fang, X., Xing, B., Wang, Y., Li, J., Liu, J., Zhai, Y., & Ma, D. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3619263 · Cited by 8
“The magnetic fields generated by the brain (approximately 0.1 fT / Hz 1 / 2 ) are far weaker than ambient magnetic fields [13].”
InfluentialWafer‐scale integration of photonic integrated circuits and atomic vapor cells
Grosman, A., Zektzer, R., Mazurski, N., Stern, L., & Levy, U. (2025) · Nanophotonics · doi:10.1515/nanoph-2025-0500 · Cited by 8
Thermally Polarized Solid-State Spin Sensor
Wilcox, R. G., Eisenach, E. R., Barry, J. F., Steinecker, M., O’Keeffe, M. F., Englund, D. R., & Braje, D. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.044004 · Cited by 8
Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer
Lu, F., Wang, S., Xu, N., Li, B., Lu, J., & Han, B. (2022) · Photonics · doi:10.3390/photonics9110792 · Cited by 8
Liu, X., Zhu, J., Wang, S., & Zhu, L. (2023) · Sensors International · doi:10.1016/j.sintl.2023.100233 · Cited by 7
Yong, 刘. L., Haobin, 林. L., Shaochun, 张. Z., Yang, 董. D., Xiangdong, 陈. C., & Fangwen, 孙. S. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop230704 · Cited by 7
Zhang, G., Zeng, H., Guo, R., Zhang, Q., Yu, W., & Lin, Q. (2023) · Optics Letters · doi:10.1364/ol.496076 · Cited by 9
Barmpatza, A. C., Baklezos, A. T., Vardiambasis, I. O., & Nikolopoulos, C. D. (2024) · Applied Sciences · doi:10.3390/app14125134 · Cited by 7
Analysis and suppression of cross-axis modulation coupling errors in optically pumped magnetometers
Long, T., Song, X., Duan, Z., Dai, Y., Suo, Y., Jia, L., & Han, B. (2024) · Measurement · doi:10.1016/j.measurement.2024.115824 · Cited by 8
Femtotesla atomic magnetometer for zero- and ultralow-field nuclear magnetic resonance
Hong, T., Wang, Y., Shao, Z., Li, Q., Jiang, M., & Peng, X. (2024) · Magnetic Resonance Letters · doi:10.1016/j.mrl.2024.200170 · Cited by 11
“The sensitivity of state-of-the-art SERF magnetometers is primarily limited by magnetic-fi eld noise due to Johnson noise of the m -metal shields [22,35].”
High-Shielding Coefficient and Low-Noise of Cobalt-Based Metallic Glass Magnetic Shielding Cylinder
Shen, P., Zhang, S., Ma, D., Xing, B., Chen, H., Zhang, M., Wei, H., Li, B., Miao, X., Xie, M., et al. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3545841 · Cited by 7
“The spin-exchange relaxation-free (SERF) magnetometer competes with the SQUID detector as the ultrahigh-sensitive magnetic field sensor [7], which optically detects polarization change of alkali metal vapor under an external magnetic field [8], [9].”
Space-Variant Polarization Distribution Mitigates AC-Stark Shifts in a SERF Atomic Magnetometer
Liang, Z., Long, T., Liu, L., Hu, J., Zhou, P., Hu, G., Wang, Y., & Ye, M. (2025) · ACS Photonics · doi:10.1021/acsphotonics.4c02535 · Cited by 7
An atomic magnetometer with autonomous frequency stabilization and large dynamic range
Pradhan, S., Mishra, S., Behera, R., Poornima, & Dasgupta, K. (2015) · Review of Scientific Instruments · doi:10.1063/1.4921901 · Cited by 10
Superconducting film magnetic flux transformer with micro- and nanosized branches
Ichkitidze, L. P. (2013) · AIP Advances · doi:10.1063/1.4812700 · Cited by 7
Highly sensitive multi-channel atomic magnetometer
Kim, Y. J., & Savukov, I. (2018) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2018.8336715 · Cited by 8
“1(a)) while it is generally used for normalization by subtracting the signals from two beams after a beam splitter [7].”
MethodInfluentialEnhanced fully optically pumped magnetic resonance with optical sideband auxiliary pumping
Jiang, Z., Liu, X., Lin, P., Qu, J., & Liu, H. (2019) · Optics Letters · doi:10.1364/ol.45.000105 · Cited by 6
Design and realization of a weak magnetic fast electric heating chip
Guo, Q., Li, Z., Zhao, R., Wen, H., Guo, H., Tang, J., & Liu, J. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/abfc32 · Cited by 7
Zero-field spin-noise spectrum of an alkali vapor with strong spin-exchange coupling
Ya, W., Li, X., Zhang, G., & Zhao, K. (2021) · Physical Review A · doi:10.1103/physreva.104.063708 · Cited by 8
“This effect lies at the heart of many applications of quantum metrology, such as the spin-exchange relaxation free (SERF) magnetometer [16,17], rotation sensors [18,19], searching new forces [20–22], and spin entanglement and squeezing in ultracold alkali gases [23–27].”
BackgroundZhu, M., Wang, L., Guo, J., Zhao, X., Sun, X., Ye, C., & Zhou, X. H. (2021) · Optics Express · doi:10.1364/oe.435841 · Cited by 7
Cavity-enhanced polarization rotation measurements for low-disturbance probing of atoms
Mazzinghi, C., Orenes, D. B., Gomez, P., Lucivero, V. G., Aybar, E., Gugnani, S., & Mitchell, M. W. (2021) · Optics Express · doi:10.1364/oe.438675 · Cited by 7
Force‐Induced Remnant Magnetization Spectroscopy for Specific Magnetic Imaging of Molecules
Yao, L., & Xu, S. (2011) · Angewandte Chemie · doi:10.1002/ange.201007297 · Cited by 7
In situ measurement of magneto-optical non-orthogonality in miniaturized atomic magnetometer
Li, R., Liu, Y., Cao, Q., Li, J., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114509 · Cited by 7
Liu, S., Wei, Y., Liu, F., Wang, R., Yuan, L., Zhai, Y., & Wang, Z. (2023) · Photonics · doi:10.3390/photonics10101091 · Cited by 7
Femtotesla 87Rb magnetometer based on a coaxial pump-probe beam delivery system
Zhao, B., Tang, J., Li, L., Zhang, Y., Liu, Y., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114856 · Cited by 8
Analysis of the electrons-nuclei coupled atomic gyroscope
Dong, H., Fang, J., Qin, J., & Yao, C. (2011) · Optics Communications · doi:10.1016/j.optcom.2011.02.053 · Cited by 9
Reimer, J. A. (2003) · Nature · doi:10.1038/426508a · Cited by 7
Simultaneous stabilization of frequency and magnetic field with the tilted 0-0 state
Jau, Y., & Happer, W. (2005) · Applied Physics Letters · doi:10.1063/1.2131180 · Cited by 7
Mapping the Cardiomagnetic Field with 19 Room Temperature Second-Order Gradiometers
Weis, A., Bison, G., Castagna, N., Cook, S., Hofer, A., Kasprzak, M., Knowles, P., & Schenker, J.-L. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12197-5_9 · Cited by 9
Liu, X.-J., Ding, M., Li, Y., Hu, Y., Jin, W., & Fang, J. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/7/073201 · Cited by 9
Ji, Z., Ding, M., Hu, Y., Yao, H., Ma, D., Cai, J., Lu, J., & Han, B. (2019) · IEEE Access · doi:10.1109/access.2019.2917894 · Cited by 7
Enhanced Coupling of Electron and Nuclear Spins by Quantum Tunneling Resonances
Tsinovoy, A., Katz, O., Landau, A., & Moiseyev, N. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.013401 · Cited by 7
Quantum optical magnetic field sensor for neurodiagnostic systems of a new generation
Petrenko, M. V., Pazgalev, A. S., & Vershovskii, A. K. (2022) · Quantum Electronics · doi:10.1070/qel17978 · Cited by 8
Gevorgyan, A. H., Harutyunyan, M. Z., Oganesyan, K. B., & Rafayelyan, M. S. (2012) · Optik · doi:10.1016/j.ijleo.2011.10.003 · Cited by 7
MolecularCP-violating magnetic moment
Derevianko, A., & Kozlov, M. G. (2005) · Physical Review A · doi:10.1103/physreva.72.040101 · Cited by 7
Petrenko, M., & Vershovskii, A. (2022) · Sensors · doi:10.3390/s22249862 · Cited by 6
Magnetic-resonance linewidth of alkali-metal vapor in the unresolved Zeeman-resonance regime
Tang, F., & Zhao, N. (2025) · Physical Review A · doi:10.1103/physreva.111.013103 · Cited by 9
Improving the Sensitivity of a Dark-Resonance Atomic Magnetometer
Zhai, H., Li, W., & Jin, G. F. (2025) · Sensors · doi:10.3390/s25041229 · Cited by 7
“We used the least squares method to fi t the experimental data.”
Pei, Y., Wang, C., Qin, J., Tong, Y., Wei, R., Weng, Y., Liu, F., Quan, W., Chai, Z., & Zhang, Y. (2025) · ACS Photonics · doi:10.1021/acsphotonics.4c02361 · Cited by 6
All-Optical Broadband Atomic Magnetometer Utilizing Raman-Driven Spin Noise Spectroscopy
Majumder, S., & Chaudhuri, S. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3554278 · Cited by 7
“Sensitivity is one of the crucial parameters to characterize any magnetometer [13], [39], [40], [41], [42].”
Ultra-stable and high-performance squeezed vacuum source enabled via artificial intelligence control
Zhao, J., Yu, Z., Chen, X., Wu, Y., Liang, X., Huang, W., Zhang, K., Yuan, C.-H., & Chen, L. Q. (2025) · Science Advances · doi:10.1126/sciadv.adu4888 · Cited by 10
Magnetic field compensation method of dual-beam SERF atomic magnetometer under probing-axis bias
Song, X., Wu, D., Long, T., Wu, Z., & Jia, L. (2025) · Measurement · doi:10.1016/j.measurement.2025.118102 · Cited by 8
Design of a Photonic Crystal Fiber Optic Magnetic Field Sensor Based on Surface Plasmon Resonance
Yi, Y., Yang, H., Sun, T., Yi, Z., Zhou, Z., Liu, C., & Yi, Y. (2025) · Sensors · doi:10.3390/s25133931 · Cited by 6
“These limitations restrict electrical sensors to harsh conditions, such as superconducting quantum interferometers needing liquid nitrogen cooling [13] and spin-exchange relaxation-free atomic magnetometers functioning only near zero magnetic fields [14,15].”
Xu, X., Zhai, Y., Zhao, B., Zhang, Y., Yue, Z., & Tang, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3612562 · Cited by 7
“Most notably, OPMs operated in the spin-exchange relaxation-free (SERF) regime have achieved remarkable sensitivity on the order of sub-fT / Hz 1 / 2 [9], [10], surpassing the performance of traditional superconducting quantum interference devices (SQUIDs) [11], [12], [13].”
Liu, Y., Xu, F., Li, S., Chen, Y., Fang, X., Ma, D., & Han, B. (2026) · Measurement · doi:10.1016/j.measurement.2026.121266 · Cited by 6
Experimental system to detect the electromagnetic response of high-frequency gravitational waves
Zheng, H., & Wei, L. F. (2022) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.106.104003 · Cited by 6
Xu, K., Ren, X., Xiang, Y., Zhang, M., Zhao, X., Ma, K., Tian, Y., Wu, D., Zeng, Z., & Wang, G. (2023) · Sensors · doi:10.3390/s23218919 · Cited by 6
“In particular, the sensitivity of SERF all-optical electron precession magnetometers can reach the fT or even aT level in near-zero magnetic fields [12–15].”
BackgroundLong, T., Song, X., Wu, Z., Suo, Y., Jia, L., Qi, S., Duan, Z., & Han, B. (2024) · Measurement · doi:10.1016/j.measurement.2024.114711 · Cited by 9
Yang, S., Yang, K., Zhang, L., Ren, Y., Liu, L., Zhang, H., Feng, L., Ma, Z., Zhou, S., He, Y., et al. (2024) · Cardiovascular Innovations and Applications · doi:10.15212/cvia.2024.0031 · Cited by 8
Observation of spin precession resonance in a stirred quantum fluid of light
Gnusov, I., Baryshev, S., Sigurðsson, H., Sitnik, K., Töpfer, J. D., Alyatkin, S., & Lagoudakis, P. G. (2024) · Optica · doi:10.1364/optica.527868 · Cited by 11
Zhang, H. L., Zou, S., Quan, W., & Chen, X. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115900 · Cited by 6
Superadaptive magnetic-field profile design based on stream-function active random selection
Wang, S., Lu, J., Gao, X., Zhao, L., Qi, Y., Li, X., & Fang, J. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.064055 · Cited by 6
Sun, J., Chai, Z., Yang, Y., Cui, Z., Xu, Y., Xu, Y., Fu, Y., & Yuan, H. (2025) · Nanoscale · doi:10.1039/d4nr04794j · Cited by 6
Enhancement of Electron-Spin Polarization Using Magneto-Optical Synchronous Modulation
Fang, C., Jiang, L., Liu, J., Chen, Y., Zhu, J., Shao, Q., Zou, Y., & Quan, W. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3541674 · Cited by 8
“O PTICALLY pumped magnetometers (OPMs) are widely used in magnetic field sensing and have made great progress in recent years [1], [2], [3].”
Circular Dichroism Analysis and Ellipticity Measurement in SERF Atom Ensemble
Lv, H., Xing, B., Fang, X., Ma, D., & Lu, H. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3545202 · Cited by 8
“SERF magnetometer is of great significance for biomedicine [9], [10], [11], [12], fundamental physics [13], [14], [15], [16], magnetic source imaging (MSI) [17], magnetoencephalography (MEG) [18], [19], and magnetocardiography (MCG) [20].”
Pulsed dual-axis alkali-metal–noble-gas comagnetometer
Wang, J., Lee, J., Loughlin, H. A., Hedges, M. P., & Romalis, M. V. (2025) · Physical Review A · doi:10.1103/physreva.111.053103 · Cited by 10
Self-citationMeasurement of129Xe frequency shift due to Cs—129Xe collisions
Fang, J., Wan, S., & Chen, Y. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/6/063401 · Cited by 8
Talker, E., Stern, L., Naiman, A., Barash, Y., & Levy, U. (2017) · Journal of Physics Communications · doi:10.1088/2399-6528/aa9396 · Cited by 6
Modeling and Reduction of the Initial Orientation Error of a Coil Vector Magnetometer
Ge, J., Huo, Z., Dong, H., Liu, H., Qian, J., Wang, R., Luo, W., Zheng, Q., Yuan, Z., Zhang, H., et al. (2020) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2020.3035727 · Cited by 6
“Although the SERF three-component magnetometer can reach several aT/(Hz)1/2, its small dynamic range (only tens of nT) makes it difficult to measure the geomagnetic field directly, necessitating the geomagnetic background field to be offset [2], [24], [25].”
BackgroundLi, X., Wang, Z., Chen, W., Ning, X., Quan, W., & Zhai, Y. (2020) · Applied Optics · doi:10.1364/ao.409600 · Cited by 6
Design of coaxial coils using hybrid machine learning
Chen, J., Wu, Z., Bao, G., Chen, L. Q., & Zhang, W. (2021) · Review of Scientific Instruments · doi:10.1063/5.0040650 · Cited by 6
Scanning Imaging of Magnetic Nanoparticles for Quantitative Molecular Imaging
Yao, L., Jamison, A. C., & Xu, S. (2010) · Angewandte Chemie · doi:10.1002/ange.201002830 · Cited by 6
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Rabi oscillation of spin-polarized rubidium in the spin-exchange relaxation-free regime
Wang, Y., Tang, J., Zhou, B., Jin, G., Shi, T., Zou, S., & Han, B. (2022) · Optics Express · doi:10.1364/oe.471475 · Cited by 7
Li, L., Tang, J., Zhao, B., & Zhai, Y. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106728 · Cited by 7
Neural network-aided optimisation of a radio-frequency atomic magnetometer
Yao, H., Maddox, B., & Renzoni, F. (2023) · Optics Express · doi:10.1364/oe.498163 · Cited by 8
“√ Sub-fT/ Hz sensitivities were reported for atomic magnetometers in shielded environment [3,10,11].”
BackgroundSERF-like magnetometry in room-temperature environment
Bao, G., Chen, J., Wang, R., Chen, L. Q., & Zhang, W. (2023) · Optics Express · doi:10.1364/oe.500875 · Cited by 6
Xu, T., Jia, L., Wang, Z., Song, X., Long, T., Wu, Z., & Duan, Z. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114753 · Cited by 6
A low noise, nonmagnetic fluorescence detector for precision measurements
Zhu, K., Solmeyer, N., & Weiss, D. S. (2012) · Review of Scientific Instruments · doi:10.1063/1.4765745 · Cited by 6
Magnetic Resonance at or below the Earth's Magnetic Field
Thiele, C. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700730 · Cited by 8
Nanoscale magnetic sensing using spin qubits in diamond
Maze, J. R., Cappellaro, P., Childress, L., Dutt, M. V. G., Hodges, J. S., Hong, S., Jiang, L., Stanwix, P. L., Taylor, J. M., Togan, E., et al. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.813802 · Cited by 7
Chen, Y.-T., Jamison, A. C., Lee, T. R., & Xu, S. (2016) · ACS Central Science · doi:10.1021/acscentsci.5b00325 · Cited by 6
Magnetoviscoelastic Ferrofluid-Based Magnetometer
Hatipoglu, G., & Tadigadapa, S. A. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2501819 · Cited by 6
“quantum interference devices (SQUID) [7]–[9].”
Li, X., Quan, W., Fan, W., Li, R., Jiang, L., & Fang, J. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaaefc · Cited by 6
Transverse optical pumping of spin states
Katz, O., & Firstenberg, O. (2019) · Communications Physics · doi:10.1038/s42005-019-0170-4 · Cited by 6
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.