A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“In our magnetometer operating at zero field, the effective γ for sensitivity estimates is γ e gµ B / p (equation (7) of ref”
BackgroundSelf-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Items 701–800 of 1,000
Differential Measurement With the Balanced Response of Optically Pumped Atomic Magnetometers
Ichihara, S., Mizutani, N., Ito, Y., & Kobayashi, T. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2547364 · Cited by 14
“Differential measurement [3] by dividing a probe beam into multiple beams and subtracting the two outputs of the photodiodes has already proved that the intrinsic noise of an OPAM is as low as 160 aT in a dedicated system [4].”
BackgroundA vector atomic magnetometer based on the spin self-sustaining Larmor method
Zhao, Q., Fan, B. L., Wang, S. G., & Wang, L. J. (2019) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2019.03.025 · Cited by 16
Tang, F., Li, A.-X., Zhang, K., Wang, Y., & Zhao, N. (2019) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ab2a99 · Cited by 15
A synthetic optically pumped gradiometer for magnetocardiography measurements*
Zhang, S., & Cao, N. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab7801 · Cited by 14
Search for plant biomagnetism with a sensitive atomic magnetometer
Corsini, E., Acosta, V. M., Baddour, N., Higbie, J., Lester, B., Licht, P., Patton, B., Prouty, M. D., & Budke, D. (2011) · Bucknell Digital Commons (Bucknell University) · Cited by 14
In-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers
Yin, K., Zhou, B., Lu, J., Lu, F., Zhang, S., Yan, Y., & Ye, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3131734 · Cited by 15
Toward portable nuclear magnetic resonance devices using atomic magnetometers
Yu, D., Garcia, N. C., & Xu, S. (2009) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.20134 · Cited by 14
SQUIDs Remain Best Tools for Measuring Brain’s Magnetic Field
Wikswo, J. P. (2004) · Physics Today · doi:10.1063/1.1688056 · Cited by 13
Perspective: Practical atom-based quantum sensors
Brown, J. M., & Walker, T. G. (2025) · Physical Review A · doi:10.1103/q6d1-594v · Cited by 20
The Space Density Distribution of Alkali Metal Atoms in a SERF Atomic Magnetometer
Guo, Q., Li, X., Zhang, N., Lu, J., Ma, D., Li, Z., & Jiang, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3146415 · Cited by 13
Lifetime estimation model of vapor cells in atomic magnetometers
Liu, Z., Zou, S., Yin, K., Zhou, B., Ning, X., & Yuan, H. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac677b · Cited by 12
Review of the Applications of Kalman Filtering in Quantum Systems
Ma, K., Kong, J., Wang, Y., & Lu, X.-M. (2022) · Symmetry · doi:10.3390/sym14122478 · Cited by 18
Temperature characteristics of Rb-N2 single-beam magnetometer with different buffer gas pressures
Zhang, S., Zhou, Y., Lu, F., Yan, Y., Wang, W., Zhou, B., Zhai, Y., Lu, J., & Ye, M. (2023) · Measurement · doi:10.1016/j.measurement.2023.112860 · Cited by 13
Ferrimagnetic Oscillator Magnetometer
Barry, J. F., Irion, R. A., Steinecker, M., Freeman, D. K., Kedziora, J., Wilcox, R. G., & Braje, D. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.044044 · Cited by 17
“For comparison, typical paramagnetic spin systems exhibit spin densities within a few orders of magnitude of 10(17)/cm(3) [29], while alkali vapor cells operate with a spin density ∼ 10(13)/cm(3) [115].”
BackgroundXun, M., Pan, G., Sun, Y., Zhou, X., Wang, Y., Liu, Y., Yang, C., & Wu, D. (2024) · Journal of Lightwave Technology · doi:10.1109/jlt.2024.3403884 · Cited by 14
Hu, J., Liang, Z., Zhou, P., Liu, L., Hu, G., & Ye, M. (2024) · Nanophotonics · doi:10.1515/nanoph-2024-0296 · Cited by 13
“For example, optically pumped magnetometers (OPMs) based on hot alkali vapor require light with specific linear polarization and collimated wavefront to implement optical probing of polarized atomic spins [10], [11].”
Magnetic field imaging with atomic Rb vapor
Mikhailov, E. E., Novikova, I. V., Havey, M. D., & Narducci, F. A. (2009) · Optics Letters · doi:10.1364/ol.34.003529 · Cited by 16
Detecting molecules and cells labeled with magnetic particles using an atomic magnetometer
Yu, D., Ruangchaithaweesuk, S., Yao, L., & Xu, S. (2012) · Journal of Nanoparticle Research · doi:10.1007/s11051-012-1135-7 · Cited by 13
“…applications: superconducting quantum interference devices (SQUIDs) (Horng et al. 2005; Fong et al. 2005; Chemla et al. 2000), giant magneto-resistive (GMR) sensors (Pannetier et al. 2004; Osterfeld et al. 2008), and atomic magnetometers (Budker et al. 2000; Kominis et al. 2003; Shah et al. 2007).”
BackgroundHigh Sensitivity Optically Pumped Quantum Magnetometer
Tiporlini, V., & Alameh, K. (2013) · The Scientific World JOURNAL · doi:10.1155/2013/858379 · Cited by 13
Quantum Biometrics with Retinal Photon Counting
Loulakis, M., Blatsios, G., Vrettou, C. S., & Kominis, I. K. (2017) · Physical Review Applied · doi:10.1103/physrevapplied.8.044012 · Cited by 13
“While modern optical magnetometers [58, 59] are about three orders of magnitude away from 10 − 9 , quantum thermometers [60–62] are many more orders of magnitude away.”
BackgroundSelf-citationPrecision measurements with cold atoms and trapped ions*
Zhang, Q., Wang, Y., Zhu, C., Wang, Y., Zhang, X., Gao, K., & Zhang, W. (2020) · Chinese Physics B · doi:10.1088/1674-1056/aba9c6 · Cited by 17
Critical dynamics and phase transition of a strongly interacting warm spin gas
Horowicz, Y., Katz, O., Raz, O., & Firstenberg, O. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2106400118 · Cited by 14
Wu, Z., Zhang, J., He, M., Ren, B., Wang, Z., Chen, W., Ou, Z., Yue, H., Zhou, X., & Liu, Y. (2023) · Optics Express · doi:10.1364/oe.484984 · Cited by 13
Dual-Species All-Optical Magnetometer Based on a Cs-K Hybrid Vapor Cell
Ding, Y., Xiao, W., Zhao, Y., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.034066 · Cited by 15
Liu, Z., Lu, J., Yan, Y., Zhan, D., Wang, W., Li, X., & Li, J. (2023) · Measurement Science and Technology · doi:10.1088/1361-6501/accdf6 · Cited by 13
Low field MRI with magnetoresistive mixed sensors
Sergeeva-Chollet, N., Dyvorne, H., Dabek, J., Herreros, Q., Polovy, H., Goff, G. L., Cannies, G., Pannetier-Lecoeur, M., & Fermon, C. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/303/1/012055 · Cited by 16
Optimization of Five-Shell Axial Magnetic Shields Having Openings in the End-Caps
Paperno, E., Romalis, M. V., & Noam, Y. (2004) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.830230 · Cited by 13
“For example in a recently developed subfemtoteslsa multichannelatomic magnetometer [1], an access to the shield’s interior should be provided for the laser beam.”
BackgroundSelf-citationFang, J., Wang, T., Zhang, H., Li, Y., & Cai, H. (2015) · Chinese Physics B · doi:10.1088/1674-1056/24/6/060702 · Cited by 15
Spin dynamics of the potassium magnetometer in spin-exchange relaxation free regime
Fu, J., Du, P., Zhou, Q., & Wang, R. (2016) · Chinese Physics B · doi:10.1088/1674-1056/25/1/010302 · Cited by 13
Faraday-Rotation Atomic Magnetometer Using Triple-Chromatic Laser Beam
Zhang, Y., Tian, Y., Li, S., Chen, J., & Gu, S. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.011004 · Cited by 12
Coherent remote control of quantum emitters embedded in polymer waveguides
Landowski, A., Gutsche, J., Guckenbiehl, S., Schönberg, M., von Freymann, G., & Widera, A. (2020) · APL Photonics · doi:10.1063/1.5124618 · Cited by 13
Quantum Magnetometer with Dual‐Coupling Optomechanics
Zhu, G., Liu, J., Wu, Y., & Lü, X. (2022) · Laser & Photonics Review · doi:10.1002/lpor.202100636 · Cited by 13
Magnetic Field Vector Detection in Frequency Domain with an Optically Pumped Atomic Magnetometer
Mizutani, N., & Kobayashi, T. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2200657 · Cited by 13
“O PTICALLY pumped atomic magnetometers (OPAMs) are attracting wide attention as high-sensitivity weak magnetic field measurement sensors [1]–[3].”
BackgroundAnalysis of parahydrogen polarized spin system in low magnetic fields
Türschmann, P., Colell, J. F. P., Theis, T., Blümich, B., & Appelt, S. (2014) · Physical Chemistry Chemical Physics · doi:10.1039/c4cp01807a · Cited by 14
Amplitude-modulated indirect pumping of spin orientation in low-density cesium vapor
Gartman, R., & Chałupczak, W. (2015) · Physical Review A · doi:10.1103/physreva.91.053419 · Cited by 13
All-Optical Magnetometric Sensor for Magnetoencephalography and Ultralow Field Tomography
Vershovskii, A. K., Pazgalev, A. S., & Petrenko, M. V. (2020) · Technical Physics Letters · doi:10.1134/s1063785020090126 · Cited by 12
Chi, H., Yuan, H., Cai, Z., Wang, X., Shang, H., Hu, Z., & Zhou, B. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac2f13 · Cited by 13
“Therefore, the SERF magnetometer has been widely investigated [6–9].”
Ma, Y., Zhang, K., Wang, Y., Yang, K., Zhai, Y., & Lu, J. (2022) · Optics Express · doi:10.1364/oe.459995 · Cited by 12
Li, S., Xing, B., Fang, X., Wang, K., Gao, Y., Wei, Q., & Han, B. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106546 · Cited by 14
Research on the anti-interference ability of optically pumped magnetometer
Li, L., Ding, Z., Tang, J., Zhao, B., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113405 · Cited by 12
Optically pumped magnetometers based on pseudo-random-bit-sequence phase modulation
Ma, N., Duan, L., Fang, X., Xing, B., Ma, D., Lu, J., & Han, B. (2023) · Applied Physics Letters · doi:10.1063/5.0164896 · Cited by 12
Synchronous recording of magnetocardiographic and electrocardiographic signals
Pȩczalski, K., Sobiech, J., Buchner, T., Kornack, T. W., Foley, E. L., Janczak, D., Jakubowska, M., Newby, D. E., Ford, N., & Zajdel, M. (2024) · Scientific Reports · doi:10.1038/s41598-024-54126-5 · Cited by 18
“Certain types of novel magnetometers include atomic 11,15,17 or quantum 18 devices.”
BackgroundSelf-citationSai, T., Wang, P., Gu, X., Xu, X., Sun, J., & Ye, J. (2024) · Materials Today Advances · doi:10.1016/j.mtadv.2024.100487 · Cited by 12
Effects of power broadening on NMOR of alkali atoms with partially resolved hyperfine structure
Lu, Z., Jiang, L., Zhao, X. H., Liu, J., Tian, M., Chai, Y., & Lei, X. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115418 · Cited by 12
Huang, B., Liu, Y., Li, R., Li, J., Tang, J., & Zhai, Y. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115523 · Cited by 12
Correcting heading errors in optically pumped magnetometers through microwave interrogation
Kiehl, C., Menon, T. S., Hewatt, D. P., Knappe, S. A., Thiele, T., & Regal, C. A. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.014005 · Cited by 13
Remote detection optical magnetometry
Akulshin, A. M., Budker, D., Bustos, F. P., Dang, T., Klinger, E., Rochester, S., Wickenbrock, A., & Zhang, R. (2024) · Physics Reports · doi:10.1016/j.physrep.2024.11.004 · Cited by 13
“Although the ultimate sensitivity with this approach is typically not as high as that of magnetometers based on direct detection of Larmor precession, as the sensitivity surpassing fT/ √ Hz level was reported in a spin-exchange-free (SERF) regime [46] and projected for magnetometry based on nonlinear Faraday effect [4…”
BackgroundApproaching the Quantum Limit of Energy Resolution in Animal Magnetoreception
Kominis, I. K., & Gkoudinakis, E. (2025) · PRX Life · doi:10.1103/prxlife.3.013004 · Cited by 18
Self-citationChai, C., Yang, X. M., Zheng, Y., Heyat, M. B. B., Li, Y., Yang, D.-B., Chen, Y.-H., & Sawan, M. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117321 · Cited by 14
A High Sensitivity Laser-Pumped Cesium Magnetometer
Huang, K., Li, N., & Lu, X. (2012) · Chinese Physics Letters · doi:10.1088/0256-307x/29/10/100701 · Cited by 12
Kasai, H., Takeuchi, Y., Hakoshima, H., Matsuzaki, Y., & 都倉, 康. (2022) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.91.074005 · Cited by 16
Frequency Response of Optically Pumped Magnetometer with Nonlinear Zeeman Effect
Zhang, R., Wu, T., Chen, J., Peng, X., & Guo, H. M. (2020) · Applied Sciences · doi:10.3390/app10207031 · Cited by 14
Compact magnetic field sensor based on plasmonic fiber-tip
Liu, Y., Liao, Q., Wang, Z., Bi, Y., Huang, L., Wang, Y., & Li, X. (2021) · Optics Express · doi:10.1364/oe.443104 · Cited by 12
Brazhnikov, D. V., Vishnyakov, V. I., Goncharov, A., Alipieva, E. A., Andreeva, C., & Taskova, E. T. (2022) · Physical Review A · doi:10.1103/physreva.106.013113 · Cited by 12
“Sensitivity of atomic magnetometers (AMs) has already reached that of superconducting quantum interference devices (SQUIDs) [1].”
BackgroundOn‐Chip Light–Atom Interactions: Physics and Applications
Wang, W., Xu, Y., & Chai, Z. (2022) · Advanced Photonics Research · doi:10.1002/adpr.202200153 · Cited by 12
Optimal Design of Planar Coils With Reverse Current Distribution for Atomic Devices
Wang, S., Lu, J., Lu, F., Lu, C., & Zhang, X. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3214619 · Cited by 15
“magnetometers [9], which have developed rapidly in recent years.”
BackgroundEveraert, K., Sander, T. H., Körber, R., Löwa, N., Waeyenberge, B. V., Leliaert, J., & Wiekhorst, F. (2023) · Nanoscale Advances · doi:10.1039/d3na00016h · Cited by 13
Interaxial time-domain interference in single-beam SERF magnetometer
Lin, S., Yuan, Z., Tang, J., Lu, J., Cao, Q., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.112890 · Cited by 11
Precision limit of atomic magnetometers in the presence of spin-destruction collisions
Liu, L., Cheng, S., Qi, B., Xi, Z., & Dong, D. (2015) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/48/3/035502 · Cited by 13
Dispersive probing of driven pseudospin dynamics in a gradient field
Deb, A. B., Sawyer, B. J., & Kjærgaard, N. (2013) · Physical Review A · doi:10.1103/physreva.88.063607 · Cited by 12
Number-unconstrained quantum sensing
Mitchell, M. W. (2017) · Quantum Science and Technology · doi:10.1088/2058-9565/aa80c0 · Cited by 16
Chang, Y., Guo, Y., & Qin, J. (2019) · Physical Review A · doi:10.1103/physreva.99.063411 · Cited by 12
Sensitive spatially resolved magnetometry using a Bose-condensed gas with a bright probe
Sekiguchi, N., Shibata, K., Torii, A., Toda, H., Kuramoto, R., Fukuda, D., & Hirano, T. (2021) · Physical Review A · doi:10.1103/physreva.104.l041306 · Cited by 12
Q-monopole-ball: a topological and nontopological soliton
Yang Bai, A., Lu, S. Q., & Orlofsky, N. (2022) · Journal of High Energy Physics · doi:10.1007/jhep01(2022)109 · Cited by 12
Nonlinear magneto-optic polarization rotation with intense laser fields
Hsu, P. S., Patnaik, A. K., & Welch, G. R. (2008) · Physical Review A · doi:10.1103/physreva.78.053817 · Cited by 12
Conversion of laser-frequency noise to optical-rotation noise in cesium vapor
Jiménez-Martínez, R., Knappe, S. A., Griffith, W. C., & Kitching, J. E. (2009) · Optics Letters · doi:10.1364/ol.34.002519 · Cited by 12
Atomic CP -violating polarizability
Ravaine, B., Kozlov, M. G., & Derevianko, A. (2005) · Physical Review A · doi:10.1103/physreva.72.012101 · Cited by 12
High contrast atomic magnetometer based on coherent population trapping
Yang, A., Yang, G., Xu, Y., & Lin, Q. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/2/027601 · Cited by 12
Hu, Y., Liu, X., Li, Y., Yao, H., Dai, L., Yang, B., & Ding, M. (2017) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aa7325 · Cited by 13
Quantum manipulation of nitrogen -vacancy centers in diamond: From basic properties to applications
Ríos, J. M. (2010) · Americanae (AECID Library) · Cited by 18
Phase-Modulated Cavity Magnon Polaritons as a Precise Magnetic Field Probe
Crescini, N., Carugno, G., & Ruoso, G. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.16.034036 · Cited by 19
“types of magnetic field detectors are essentially two: superconducting quantum interference devices (SQUIDs) [1–5] and spin-exchange relaxation-free (SERFs) [6–8] magnetometers, which reach the fT/ √ Hz sensitivity.”
BackgroundLi, S., Dai, P., Liu, J., Xu, Z., & Chida, K. (2022) · Optical Materials Express · doi:10.1364/ome.462911 · Cited by 14
Sun, Y., & Wang, Z. (2023) · Optics Express · doi:10.1364/oe.487426 · Cited by 11
Modeling of nonlinear and nonstationary stochasticity for atomic ensembles
Qin, B., Wang, Z., Wang, R., Li, F., Li, F., & Fang, C. (2023) · ISA Transactions · doi:10.1016/j.isatra.2023.09.019 · Cited by 11
Li, R., Liu, Y., Li, J., Cao, Q., Huang, B., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114781 · Cited by 11
Li, J., Liu, Y., Li, R., Cao, Q., Zhou, T., & Zhai, Y. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107231 · Cited by 11
A Magnetic Susceptibility Measurement System Based on a Single-Axis Atomic Magnetometer
Sun, Y., Lu, J., Zhou, Y., Wang, Y., & Zhou, Z. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3366312 · Cited by 11
“In recent years, a new type of high-sensitivity magnetometer has experienced rapid development [15], [16], [17], [18], [19].”
BackgroundA modular optically pumped magnetometer system
Coussens, T., Gialopsou, A., Abel, C., Bason, M. G., James, T. M., Evans, W., Woodley, M. T. M., Nightingale, D., Nicolau, D., Page, L., et al. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad4e60 · Cited by 11
“However, developments in the spin-exchange relaxation-free (SERF) regime over the past two decades have allowed optically pumped magnetometers (OPMs) to achieve similar sensitivities to SQUIDs [3], with a number of distinct advantages.”
BackgroundLi, R., Liu, Y., Li, J., Cao, Q., Huang, B., & Zhai, Y. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.111217 · Cited by 11
Cui, Z., Wang, Y., Liu, Y., Jin, M., Sun, J., Zhai, Y., Zhou, X., & Chai, Z. (2024) · Nanophotonics · doi:10.1515/nanoph-2024-0309 · Cited by 14
“In recent decades, the performance of atomic magnetome-ters (AMs) has greatly improved, attaining sensitivities in the sub-fT/Hz 1/2 range [1], [2].”
Wu, T., Zhao, X., Feng, L., Yang, S., Xing, H., Ma, Z., Yang, X., Zhang, M., Ding, M. L., He, Y., et al. (2025) · European Radiology · doi:10.1007/s00330-025-11389-4 · Cited by 12
“Consequently, it has been successfully applied in the examination of ischemic heart disease [18, 19].”
Optical Atomic Magnetometry for Ultra-Low-Field NMR Detection
Bevilacqua, G., Biancalana, V., Dancheva, Y. V., & Moi, L. (2013) · Annual reports on NMR spectroscopy · doi:10.1016/b978-0-12-404716-7.00003-1 · Cited by 13
Microfabricated Optically-Pumped Magnetometers
Knappe, S. A. (2014) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2014.am4l.4 · Cited by 12
“These magnetometers, often referred to as Spin-Exchange Relaxation-Free (SERF) magnetometers [1], have reached sensitivities below 1 fT-Hz − 1/2 [2, 3], and have been used by researchers to detect weak magnetic fi elds from a wide variety of sources, such as the human brain [6, 9, 11, 14], atomic…”
InfluentialSingle-Atom Transistor as a Precise Magnetic Field Sensor
Jachymski, K., Wasak, T., Idziaszek, Z., Julienne, P. S., Negretti, A., & Calarco, T. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.013401 · Cited by 11
A calibration method for coil constants using an atomic spin self-sustaining vector magnetometer
Zhao, Q., Fan, B. L., Wang, S. G., & Wang, L. J. (2020) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2020.166977 · Cited by 11
Parameters optimization of optical pumped Mz/Mx magnetometer based on rf-discharge lamp
Ke, H.-L., Hao, J., Han, B., Miao, P.-X., Zhang, J., Tu, J., Yang, W., Jing-zhong, C., Chen, J., & Liu, Z. (2020) · Optik · doi:10.1016/j.ijleo.2020.165510 · Cited by 11
Zero-field magnetometry based on the combination of atomic orientation and alignment
Gal, G. L., & Palacios-Laloy, A. (2022) · Physical Review A · doi:10.1103/physreva.105.043114 · Cited by 11
Yu, C., Ma, S., Ren, H., Chen, Z., Xiang, C.-C., Yan, Y., Wang, X., Jin, M., Li, H., & Zhou, T. (2022) · Optics Express · doi:10.1364/oe.459338 · Cited by 12
Chen, Y., Zhao, L., Ma, Y., Yu, M., Wang, Y., Zhang, N., Wei, K., & Jiang, Z. (2022) · Biomedical Optics Express · doi:10.1364/boe.474862 · Cited by 11
Li, R., Zhai, Y., Li, J., Cao, Q., & Liu, Y. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202300287 · Cited by 11
Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator
Hu, Y., Feng, Y. Y., Xu, C., Xue, H., & Sun, L. Q. (2014) · Applied Optics · doi:10.1364/ao.53.002158 · Cited by 11
External cavity diode laser with very-low frequency drift
Takamizawa, A., Yanagimachi, S., & Ikegami, T. (2016) · Applied Physics Express · doi:10.7567/apex.9.032704 · Cited by 11
Is light narrowing possible with dense-vapor paraffin coated cells for atomic magnetometers?
Han, R., Balabas, M. V., Hovde, C., Li, W., Masia‐Roig, H., Wang, T., Wickenbrock, A., Zhivun, E., You, Z., & Budker, D. (2017) · AIP Advances · doi:10.1063/1.4997691 · Cited by 11
Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation
Miao, P.-X., Yang, S., Jian-Xiang, W., Ji-Qing, L., Tu, J., Wei, Y., & Jing-zhong, C. (2017) · Acta Physica Sinica · doi:10.7498/aps.66.160701 · Cited by 12
Scale-invariant spin dynamics and the quantum limits of field sensing
Mitchell, M. W. (2020) · New Journal of Physics · doi:10.1088/1367-2630/ab81b8 · Cited by 14
Magneto-optical spectroscopy with arbitrarily polarized intensity-modulated light in He4 atoms
Wang, H., Wu, T., Wang, H., Peng, X., & Guo, H. M. (2020) · Physical Review A · doi:10.1103/physreva.101.063408 · Cited by 13
Adiabaticity in state preparation for spin squeezing of large atom ensembles
Jin, S., Bao, H., Duan, J., Lu, X., Wang, M., Zhao, K.-F., Shen, H., & Xiao, Y. (2021) · Photonics Research · doi:10.1364/prj.413288 · Cited by 11
The Uncertainty Quantification for Parameters Optimization in SERF Atomic Magnetomer
Zhao, W., Li, Y., Wang, Y., Yan, Q., Song, Q., Wang, C., Kang, X., & Gao, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3116312 · Cited by 11
“3116312 Princeton University developed an ultra-sensitive magnetic field measurement device based on the SERF state in 2003 [8].”
MethodJiang, X., Ye, S., Sohrabpour, A., Bagic, A. I., & He, B. (2021) · NeuroImage Clinical · doi:10.1016/j.nicl.2021.102903 · Cited by 13
“In principle, the combination of MAG and GRAD emphasizes brain signals with respect to environmental noise (Kominis et al., 2003; Baillet, 2017), but there is prior work suggesting that no significant improvement is achieved by combining MAG and GRAD sensors for the purposes of MEG source imaging (Tarkiainen et al.”
BackgroundZhou, F., Jia, F.-D., Mei, J., Liu, X., Zhang, H., Yu, Y., Liang, W.-C., Qin, J., Zhang, J., Xie, F., et al. (2022) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/ac5d8d · Cited by 11
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.