Neuronal ensemble control of prosthetic devices by a human with tetraplegia
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [276]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [57]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [29]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Georgopoulos, A., Kalaska, J., Caminiti, R., & Massey, J. (1982) · The Journal of Neuroscience · doi:10.1523/jneurosci.02-11-01527.1982 · Cited by 2,130
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Ditunno, J. F., Young, W., Donovan, W. H., & Creasey, G. (1994) · Spinal Cord · doi:10.1038/sc.1994.13 · Cited by 1,643
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Self-citationPlasticity and Primary Motor Cortex
Sanes, J. N., & Donoghue, J. P. (2000) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.23.1.393 · Cited by 1,202
Self-citationA brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Reshaping the Cortical Motor Map by Unmasking Latent Intracortical Connections
Jacobs, K. M., & Donoghue, J. P. (1991) · Science · doi:10.1126/science.2000496 · Cited by 1,011
Self-citationMotor control : concepts and issues
Issues, Humphrey, D. R., & Freund, H. ‐. (1991) · Wiley eBooks · Cited by 644
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Direct control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Donoghue, J. P., Sanes, J. N., Hatsopoulos, N. G., & Gaál, G. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.1.159 · Cited by 538
Self-citationEEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
Restoration of neural output from a paralyzed patient by a direct brain connection
Kennedy, P. R., & Bakay, R. A. E. (1998) · NeuroReport · doi:10.1097/00001756-199806010-00007 · Cited by 475
A demographic profile of new traumatic spinal cord injuries: Change and stability over 30 years
Jackson, A. B., Dijkers, M., DeVivo, M. J., & Poczatek, R. B. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.04.035 · Cited by 468
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
Self-citationSpatiotemporal Tuning of Motor Cortical Neurons for Hand Position and Velocity
Paninski, L., Fellows, M. R., Hatsopoulos, N. G., & Donoghue, J. P. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00587.2002 · Cited by 390 · cited 1×
“A number of factors might affect control, including: (1) the small set of randomly selected neurons recorded by this single array, compared to the very large number usually engaged; (2) the influence of spinal cord injury mechanisms or duration since injury; (3) the cortical layers recorded; (4) our approach to filter…”
BackgroundSelf-citationPredicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. D. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 370 · cited 1×
“A number of factors might affect control, including: (1) the small set of randomly selected neurons recorded by this single array, compared to the very large number usually engaged; (2) the influence of spinal cord injury mechanisms or duration since injury; (3) the cortical layers recorded; (4) our approach to filter…”
BackgroundGuest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Modeling and Decoding Motor Cortical Activity Using a Switching Kalman Filter
Wu, W., Black, M. J., Mumford, D., Gao, Y., Bienenstock, E., & Donoghue, J. P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826666 · Cited by 213
Self-citationCortical correlates of learning in monkeys adapting to a new dynamical environment
Gandolfo, F., Li, C.-S. R., Benda, B. J., Schioppa, C. P., & Bizzi, E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040567097 · Cited by 209
Operant Conditioning of Specific Patterns of Neural and Muscular Activity
Fetz, E. E., & Finocchio, D. V. (1971) · Science · doi:10.1126/science.174.4007.431 · Cited by 202
Fetz, E. E., & Baker, M. A. (1973) · Journal of Neurophysiology · doi:10.1152/jn.1973.36.2.179 · Cited by 199
A 100-channel system for real time detection and storage of extracellular spike waveforms
Guillory, K. S., & Normann, R. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00076-x · Cited by 180 · cited 1×
“A number of factors might affect control, including: (1) the small set of randomly selected neurons recorded by this single array, compared to the very large number usually engaged; (2) the influence of spinal cord injury mechanisms or duration since injury; (3) the cortical layers recorded; (4) our approach to filter…”
BackgroundExtraction algorithms for cortical control of arm prosthetics
Schwartz, A. B., Taylor, D. M., & Tillery, S. I. H. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(01)00272-0 · Cited by 148 · cited 1×
“A number of factors might affect control, including: (1) the small set of randomly selected neurons recorded by this single array, compared to the very large number usually engaged; (2) the influence of spinal cord injury mechanisms or duration since injury; (3) the cortical layers recorded; (4) our approach to filter…”
BackgroundComputer control using human intracortical local field potentials
Kennedy, P. R., Kirby, M. T., Moore, M. M., King, B., & Mallory, A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.834629 · Cited by 134
Sensors for brain-computer interfaces
Hochberg, L. R., & Donoghue, J. P. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705745 · Cited by 131
Self-citationSabbah, P., de Schonen, S., Leveque, C., Gay, S., Pfefer, F., Nioche, C., Sarrazin, J.-L., Barouti, H., Tadié, M., & Cordoliani, Y. S. (2002) · Journal of Neurotrauma · doi:10.1089/089771502753460231 · Cited by 127
Toward a Direct Brain Interface Based on Human Subdural Recordings and Wavelet-Packet Analysis
Graimann, B., Huggins, J. E., Levine, S. P., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826671 · Cited by 124
Gaze Direction Modulates Finger Movement Activation Patterns in Human Cerebral Cortex
Baker, J. T., Donoghue, J. P., & Sanes, J. N. (1999) · Journal of Neuroscience · doi:10.1523/jneurosci.19-22-10044.1999 · Cited by 117
Self-citationMotor-cortical activity in tetraplegics
Shoham, S., Halgren, E., Maynard, E. M., & Normann, R. A. (2001) · Nature · doi:10.1038/35101651 · Cited by 99
Using human extra-cortical local field potentials to control a switch
Kennedy, P., Andreasen, D. S., Ehirim, P., King, B., Kirby, T., Mao, H. Z., & Moore, M. M. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/002 · Cited by 98
Adaptation in the motor cortex following cervical spinal cord injury
Mikulis, D. J., Jurkiewicz, M. T., McIlroy, W. E., Staines, R. W., Rickards, L., Kalsi‐Ryan, S., Crawley, A. P., Fehlings, M. G., & Verrier, M. C. (2002) · Neurology · doi:10.1212/wnl.58.5.794 · Cited by 98
Lotze, M., Laubis‐Herrmann, U., Topka, H. R., Erb, M., & Grodd, W. (1999) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-1999-00078 · Cited by 75
Closed-loop cortical control of direction using support vector machines
Olson, B., Si, J., Hu, J. F., & He, J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.843174 · Cited by 57
Real-Time Control of a Video Game With a Direct Brain???Computer Interface
Mason, S. G., Bohringer, R., Borisoff, J., & Birch, G. E. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000146840.78749.79 · Cited by 48
Clinical and functional evaluation of a gaze controlled system for the severely handicapped
Thoumie, P., Charlier, J. R., Alecki, M., D'Erceville, D., Heurtin, A., Mathé, J.-F., Nadeau, G., & Wiart, L. (1998) · Spinal Cord · doi:10.1038/sj.sc.3100496 · Cited by 19 · cited 1×
“A number of factors might affect control, including: (1) the small set of randomly selected neurons recorded by this single array, compared to the very large number usually engaged; (2) the influence of spinal cord injury mechanisms or duration since injury; (3) the cortical layers recorded; (4) our approach to filter…”
Background
Cited by
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
“Core elements of the investigational BrainGate system have been described previously 6,7 .”
Self-citationBrain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“[287] implanted BrainGate sensors in the primary motor cortex of a tetraplegic patient to control a cursor.”
BackgroundEnhancing Our Lives with Immersive Virtual Reality
Slater, M., & Sanchez-Vives, M. V. (2016) · Frontiers in Robotics and AI · doi:10.3389/frobt.2016.00074 · Cited by 1,993
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Metadata
- Authors
- Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P.
- Affiliations
- Brigham and Women's Hospital (US)
- Brown University (US)
- Cyberkinetics (United States) (US)
- Shirley Ryan AbilityLab (US)
- University of Chicago (US)
- Corresponding author
- Donoghue, John P.
- Venue
- Nature
- Published
- 2006-07
- Volume
- 442
- Issue
- 7099
- Pages
- 164-171
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2114004602
- Cited by
- 3,295
- References
- 47
- Citations by year
- 2026: 63 · 2025: 131 · 2024: 113 · 2023: 117 · 2022: 119 · 2021: 158 · 2020: 129 · 2019: 150 · 2018: 150 · 2017: 143 · 2016: 186 · 2015: 169 · 2014: 226 · 2013: 231 · 2012: 199
- FWCI
- 93.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- tetraplegia, spinal cord injury, brain-computer interface, neuronal ensembles, primary motor cortex, intracortical microelectrode arrays, prosthetic hand control, robotic arm control, movement intention decoding, cervical spinal cord injury, upper limb paralysis
- MeSH terms
- Adult, Bionics, Electrodes, Humans, Male, Middle Aged, Movement, Quadriplegia, Robotics, User-Computer Interface, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.