The DOI matches its Crossref record; 39 of the 41 references it cites were found in a registry or an index.
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Open accessAbstract
Paralysis following spinal cord injury, brainstem stroke, amyotrophic lateral sclerosis and other disorders can disconnect the brain from the body, eliminating the ability to perform volitional movements. A neural interface system could restore mobility and independence for people with paralysis by translating neuronal activity directly into control signals for assistive devices. We have previously shown that people with long-standing tetraplegia can use a neural interface system to move and click a computer cursor and to control physical devices. Able-bodied monkeys have used a neural interface system to control a robotic arm, but it is unknown whether people with profound upper extremity paralysis or limb loss could use cortical neuronal ensemble signals to direct useful arm actions. Here we demonstrate the ability of two people with long-standing tetraplegia to use neural interface system-based control of a robotic arm to perform three-dimensional reach and grasp movements. Participants controlled the arm and hand over a broad space without explicit training, using signals decoded from a small, local population of motor cortex (MI) neurons recorded from a 96-channel microelectrode array. One of the study participants, implanted with the sensor 5 years earlier, also used a robotic arm to drink coffee from a bottle. Although robotic reach and grasp actions were not as fast or accurate as those of an able-bodied person, our results demonstrate the feasibility for people with tetraplegia, years after injury to the central nervous system, to recreate useful multidimensional control of complex devices directly from a small sample of neural signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [39]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The flexibility of ConvNets might also be a limitation in some brain‐signal decoding scenarios. For example if the user of a brain–computer interface should learn to adapt her or his brain signals to the decoding model, a simpler feature‐based model might yield better results.”
From Deep learning with convolutional neural networks for EEG decoding and visualization (2017) · cites this paper as Hochberg et al., 2012
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [275]
The cited source says what the claim attributes to it.
In the citing paper
“Prior BCI studies have shown that the motor intention for gross motor skills, such as reaching, grasping or moving a computer cursor, remains neurally encoded in motor cortex after paralysis1–7.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [1]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [58]
In the citing paper
“The results presented here demonstrate that CP control provides a unique opportunity for the complex control of a virtual cursor and robotic device (14, 39), without requiring discretized, prolonged task sequences (46) that can make even simple task completion long and frustrating.”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [39]
In the citing paper
“Highcount microelectrode arrays have proven useful in basic physiology research [8], and for clinical applications such as the restoration of function in people with nervous system injury [9] or stroke [10].”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [10]
In the citing paper
“Recent penetrating neural interface applications are requiring a greater number of electrodes (>60) to achieve complex neuromodulation [9,10,16] or neurophysiological [8] goals.”
From A new high-density (25 electrodes/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,542
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
The DLR lightweight robot: design and control concepts for robots in human environments
Albu‐Schäffer, A., Haddadin, S., Ott, C., Stemmer, A., Wimböck, T., & Hirzinger, G. (2007) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439910710774386 · Cited by 624
Self-citationDirect control of paralysed muscles by cortical neurons
Moritz, C. T., Perlmutter, S. I., & Fetz, E. E. (2008) · Nature · doi:10.1038/nature07418 · Cited by 610
Albu‐Schäffer, A., Eiberger, O., Grebenstein, M., Haddadin, S., Ott, C., Wimböck, T., Wolf, S., & Hirzinger, G. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927979 · Cited by 509
Self-citationSimeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Self-citation
Research works printed but not linked: 1
- Burrow, M., Dugger, J., Humphrey, D. R., Reed, D. J. & Hochberg, L. R. in Proc. ICORR ’97: Int. Conf. Rehabilitation Robotics 83–86 (Bath Institute of Medical Engineering, 1997)
Cited by
Sorted by citations
Items 101–200 of 1,013
Conscious Brain-to-Brain Communication in Humans Using Non-Invasive Technologies
Grau, C., Ginhoux, R., Riera, A., Nguyen, T. L., Chauvat, H., Berg, M., Amengual, J. L., Pascual-Leone, A., & Ruffini, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105225 · Cited by 211
Alivisatos, A. P., Chun, M., Church, G. M., Deisseroth, K. A., Donoghue, J. P., Greenspan, R. J., McEuen, P. L., Roukes, M. L., B, T. J. S. A., Weiss, P. S., et al. (2013) · Science · doi:10.1126/science.1236939 · Cited by 209
Self-citationDetecting awareness after severe brain injury
Fernández‐Espejo, D., & Owen, A. M. (2013) · Nature reviews. Neuroscience · doi:10.1038/nrn3608 · Cited by 208
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
A motion-classification strategy based on sEMG-EEG signal combination for upper-limb amputees
Li, X., Samuel, O. W., Zhang, X., Wang, H., Fang, P., & Li, G. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0212-z · Cited by 202
Hotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201
Decoding spectrotemporal features of overt and covert speech from the human cortex
Martin, S., Brunner, P., Holdgraf, C., Heinze, H.-J., Crone, N. E., Rieger, J., Schalk, G., Knight, R. T., & Pasley, B. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00014 · Cited by 200
Mitchell, P. J., Lee, S. C. M., Yoo, P. E., Morokoff, A. P., Sharma, R. P., Williams, D. L., MacIsaac, C., Howard, M. E., Irving, L., Vrljic, I., et al. (2023) · JAMA Neurology · doi:10.1001/jamaneurol.2022.4847 · Cited by 205
Representation of Muscle Synergies in the Primate Brain
Overduin, S. A., d’Avella, A., Roh, J., Carmena, J. M., & Bizzi, E. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.4302-14.2015 · Cited by 203
High accuracy decoding of user intentions using EEG to control a lower-body exoskeleton
Kilicarslan, A., Prasad, S., Grossman, R. G., & Contreras-Vidal, J. L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610821 · Cited by 196
Mobile cognition: imaging the human brain in the ‘real world’
Stangl, M., Maoz, S. L., & Suthana, N. (2023) · Nature reviews. Neuroscience · doi:10.1038/s41583-023-00692-y · Cited by 206
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
Chronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings
Kozai, T. D. Y., Catt, K. A., Du, Z. J., Na, K., Srivannavit, O., Haque, R., Seymour, J. P., Wise, K. D., Yoon, E., & Cui, X. T. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2445713 · Cited by 195
McMullen, D. P., Hotson, G., Katyal, K. D., Wester, B. A., Fifer, M. S., McGee, T. G., Harris, A., Johannes, M. S., Vogelstein, R. J., Ravitz, A., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2294685 · Cited by 191
Neuromodulation in the restoration of function after spinal cord injury
James, N. D., McMahon, S. B., Field-Fote, E. C., & Bradbury, E. J. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30287-4 · Cited by 192
Krucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00584 · Cited by 196
Neural signal analysis with memristor arrays towards high-efficiency brain–machine interfaces
Liu, Z., Tang, J., Gao, B., Yao, P., Li, X., Liu, D., Zhou, Y., Qian, H., Hong, B., & Wu, H. (2020) · Nature Communications · doi:10.1038/s41467-020-18105-4 · Cited by 199
Non-Invasive Brain-Computer Interfaces: State of the Art and Trends
Edelman, B. J., Zhang, S., Schalk, G., Brunner, P., Müller-Putz, G., Guan, C., & He, B. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3449790 · Cited by 212
A Self‐Powered Sensor Mimicking Slow‐ and Fast‐Adapting Cutaneous Mechanoreceptors
Chun, K., Son, Y. J., Jeon, E., Lee, S.-H., & Han, C. (2018) · Advanced Materials · doi:10.1002/adma.201706299 · Cited by 186
Single-trial dynamics of motor cortex and their applications to brain-machine interfaces
Kao, J. C., Nuyujukian, P., Ryu, S. I., Churchland, M. M., Cunningham, J. P., & Shenoy, K. V. (2015) · Nature Communications · doi:10.1038/ncomms8759 · Cited by 187
Michaels, J. A., Dann, B., & Scherberger, H. (2016) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1005175 · Cited by 184
Brain-Computer Interfacing: An Introduction
Rao, R. P. N. (2019) · Cited by 181
Flint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 184
Takmakov, P. A., Ruda, K., Phillips, K. S., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 183
A Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys
Ifft, P. J., Shokur, S., Li, Z., Lebedev, M., & Nicolelis, M. A. L. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006159 · Cited by 187
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
Page, D. M., George, J. A., Kluger, D. T., Duncan, C. C., Wendelken, S., Davis, T. S., Hutchinson, D. T., & Clark, G. A. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00352 · Cited by 189
Wireless Neurosensor for Full-Spectrum Electrophysiology Recordings during Free Behavior
Yin, M., Borton, D. A., Komar, J., Agha, N. S., Lu, Y., Li, H., Laurens, J., Lang, Y., Li, Q., Bull, C. W., et al. (2014) · Neuron · doi:10.1016/j.neuron.2014.11.010 · Cited by 185
Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques
Engdahl, S. M., Christie, B. P., Kelly, B. M., Davis, A. J., Chestek, C. A., & Gates, D. H. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0044-2 · Cited by 177
Highly Stretchable Gold Nanobelts with Sinusoidal Structures for Recording Electrocorticograms
Qi, D., Liu, Z., Yu, M., Liu, Y., Tang, Y., Lv, J., Li, Y., Wei, J., Liedberg, B., Yu, Z., et al. (2015) · Advanced Materials · doi:10.1002/adma.201405807 · Cited by 177
Piccinini, G. (2020) · doi:10.1093/oso/9780198866282.001.0001 · Cited by 181
Kaya, M., Binli, M. K., Özbay, E., Yanar, H., & Mishchenko, Y. (2018) · Scientific Data · doi:10.1038/sdata.2018.211 · Cited by 186
Combining Decoder Design and Neural Adaptation in Brain-Machine Interfaces
Shenoy, K. V., & Carmena, J. M. (2014) · Neuron · doi:10.1016/j.neuron.2014.08.038 · Cited by 181
Multi-Modal Sensing Techniques for Interfacing Hand Prostheses: A Review
Fang, Y., Hettiarachchi, N., Zhou, D., & Liu, H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2450211 · Cited by 177
Hand Knob Area of Premotor Cortex Represents the Whole Body in a Compositional Way
Willett, F. R., Deo, D. R., Avansino, D. T., Rezaii, P., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2020) · Cell · doi:10.1016/j.cell.2020.02.043 · Cited by 171
Self-citationBorton, D., Micera, S., Millán, J. D. R., & Courtine, G. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005968 · Cited by 171
Cortical control of a tablet computer by people with paralysis
Nuyujukian, P., Albites Sanabria, J., Saab, J., Pandarinath, C., Jarosiewicz, B., Blabe, C. H., Franco, B., Mernoff, S. T., Eskandar, E. N., Simeral, J. D., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0204566 · Cited by 170
Self-citationPolymer-based flexible capacitive sensor for three-axial force measurements
Dobrzynska, J., & Gijs, M. A. M. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/1/015009 · Cited by 170
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 183
Volitional modulation of optically recorded calcium signals during neuroprosthetic learning
Clancy, K. B., Koralek, A. C., Costa, R. M., Feldman, D. E., & Carmena, J. M. (2014) · Nature Neuroscience · doi:10.1038/nn.3712 · Cited by 171
A Compliant Ionic Adhesive Electrode with Ultralow Bioelectronic Impedance
Pan, L., Cai, P., Mei, L., Cheng, Y., Zeng, Y., Wang, M., Wang, T., Jiang, Y., Ji, B., Li, D., et al. (2020) · Advanced Materials · doi:10.1002/adma.202003723 · Cited by 171
Schwemmer, M. A., Skomrock, N. D., Sederberg, P. B., Ting, J. E., Sharma, G., Bockbrader, M. A., & Friedenberg, D. A. (2018) · Nature Medicine · doi:10.1038/s41591-018-0171-y · Cited by 173
Kwon, K. Y., Sirowatka, B., Weber, A., & Li, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282318 · Cited by 166
Soft Fiber Electronics Based on Semiconducting Polymer
Sun, F., Jiang, H., Wang, H., Zhong, Y., Xu, Y., Xing, Y., Yu, M., Feng, L., Tang, Z., Liu, J., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00720 · Cited by 167
Self-citationBioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 168
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
Self-citationCommanding a Brain-Controlled Wheelchair Using Steady-State Somatosensory Evoked Potentials
Kim, K.-T., Suk, H., & Lee, S. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2597854 · Cited by 166
Ofner, P., Schwarz, A., Pereira, J., Wyss, D., Wildburger, R., & Müller-Putz, G. (2019) · Scientific Reports · doi:10.1038/s41598-019-43594-9 · Cited by 167
Feature learning from incomplete EEG with denoising autoencoder
Li, J., Struzik, Z. R., Zhang, L., & Cichocki, A. S. (2015) · Neurocomputing · doi:10.1016/j.neucom.2014.08.092 · Cited by 165
Samal, P., & Hashmi, M. F. (2024) · Artificial Intelligence Review · doi:10.1007/s10462-023-10690-2 · Cited by 170
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
Self-citationA 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications
Yin, M., Borton, D. A., Aceros, J. C., Patterson, W. R., & Nurmikko, A. V. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2255874 · Cited by 161
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
Control of a 7-DOF Robotic Arm System With an SSVEP-Based BCI
Chen, X., Zhao, B., Wang, Y., Xu, S., & Gao, X. (2018) · International Journal of Neural Systems · doi:10.1142/s0129065718500181 · Cited by 158
Flexible Electrodes for In Vivo and In Vitro Electrophysiological Signal Recording
Zhu, M., Wang, H., Li, S., Liang, X., Zhang, M., Dai, X., & Zhang, Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100646 · Cited by 163
Invasive vs. Non-Invasive Neuronal Signals for Brain-Machine Interfaces: Will One Prevail?
Waldert, S. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00295 · Cited by 162
Current Researches and Future Development Trend of Intelligent Robot: A Review
Wang, T., Tao, Y., & Liu, H. (2018) · Machine Intelligence Research · doi:10.1007/s11633-018-1115-1 · Cited by 162
Restoring the Sense of Touch Using a Sensorimotor Demultiplexing Neural Interface
Ganzer, P. D., Colachis, S. C., Schwemmer, M. A., Friedenberg, D. A., Dunlap, C. F., Swiftney, C. E., Jacobowitz, A. F., Weber, D. J., Bockbrader, M. A., & Sharma, G. (2020) · Cell · doi:10.1016/j.cell.2020.03.054 · Cited by 156
A bioinspired analogous nerve towards artificial intelligence
Liao, X., Song, W., Zhang, X., Yan, C., Li, T., Ren, H., Liu, C., Wang, Y., & Zheng, Y. (2020) · Nature Communications · doi:10.1038/s41467-019-14214-x · Cited by 153
Rapid calibration of an intracortical brain–computer interface for people with tetraplegia
Brandman, D. M., Hosman, T., Saab, J., Burkhart, M. C., Shanahan, B. E., Ciancibello, J. G., Sarma, A. A., Milstein, D., Vargas-Irwin, C. E., Franco, B., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9ee7 · Cited by 157
Self-citationBrain-controlled modulation of spinal circuits improves recovery from spinal cord injury
Bonizzato, M., Pidpruzhnykova, G., DiGiovanna, J., Shkorbatova, P., Pavlova, N., Micera, S., & Courtine, G. (2018) · Nature Communications · doi:10.1038/s41467-018-05282-6 · Cited by 149
Teaching brain-machine interfaces as an alternative paradigm to neuroprosthetics control
Iturrate, I., Chavarriaga, R., Montesano, L., Minguez, J., & Millán, J. D. R. (2015) · Scientific Reports · doi:10.1038/srep13893 · Cited by 149
Wark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148
Mattioli, F., Porcaro, C., & Baldassarre, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac4430 · Cited by 148
RetractedAbibullaev, B., Keutayeva, A., & Zollanvari, A. (2023) · IEEE Access · doi:10.1109/access.2023.3329678 · Cited by 164
New Evidence for Therapies in Stroke Rehabilitation
Dobkin, B. H., & Dorsch, A. (2013) · Current Atherosclerosis Reports · doi:10.1007/s11883-013-0331-y · Cited by 146
Encoding and Decoding Models in Cognitive Electrophysiology
Holdgraf, C., Rieger, J. W., Micheli, C., Martin, S., Knight, R. T., & Theunissen, F. E. (2017) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2017.00061 · Cited by 154
Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording
Wei, X., Luan, L., Zhao, Z., Li, X., Zhu, H., Potnis, O., & Xie, C. (2018) · Advanced Science · doi:10.1002/advs.201700625 · Cited by 149
Printing Flexible and Hybrid Electronics for Human Skin and Eye‐Interfaced Health Monitoring Systems
Kim, K., Kim, B., & Lee, C. H. (2019) · Advanced Materials · doi:10.1002/adma.201902051 · Cited by 148
Game changers in science and technology - now and beyond
Betz, U. A. K., Arora, L., Assal, R. A., de Azevedo, H. F. Z., Baldwin, J., Becker, M. S., Bostock, S., Cheng, V. W. T., Egle, T., Ferrari, N., et al. (2023) · Technological Forecasting and Social Change · doi:10.1016/j.techfore.2023.122588 · Cited by 153
Rauschecker, J. P. (2017) · Cortex · doi:10.1016/j.cortex.2017.10.020 · Cited by 159
A CSP\AM-BA-SVM Approach for Motor Imagery BCI System
Selim, S., Tantawi, M. M., Shedeed, H. A., & Badr, A. A. (2018) · IEEE Access · doi:10.1109/access.2018.2868178 · Cited by 145
Li, Z., Yuan, Y., Luo, L., Su, W., Zhao, K., Xu, C., Huang, J., & Pi, M. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2949865 · Cited by 147
Stable long-term BCI-enabled communication in ALS and locked-in syndrome using LFP signals
Milekovic, T., Sarma, A. A., Bacher, D., Simeral, J. D., Saab, J., Pandarinath, C., Sorice, B. L., Blabe, C. H., Oakley, E. M., Tringale, K. R., et al. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00493.2017 · Cited by 148
Self-citationTranslational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 150
Kim, J.-H., Bießmann, F., & Lee, S. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2375879 · Cited by 138
Flexible Electrodes for Brain–Computer Interface System
Wang, J., Wang, T., Liu, H., Wang, K., Kumi, M., Feng, Z., Li, P., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211012 · Cited by 142
A generic non-invasive neuromotor interface for human-computer interaction
Kaifosh, P., Reardon, T. R., Labs, C.-L. A. R., Allen, B. D., Anderson, C., Arnoud, S., Arora, R., Atray, M., Awad, L., Ayerbe, F., et al. (2025) · Nature · doi:10.1038/s41586-025-09255-w · Cited by 158
Zhang, X., Ma, Z., Zheng, H., Li, T., Chen, K., Wang, X., Liu, C., Xu, L., Wu, X., Lin, D., et al. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2019.11.109 · Cited by 142
Kozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Stavisky, S. D., Kao, J. C., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036009 · Cited by 139
Li, Z., Li, J., Zhao, S., Yuan, Y., Kang, Y., & Chen, C. L. P. (2018) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2018.2872595 · Cited by 136
Human brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Tchoe, Y., Bourhis, A. M., Cleary, D. R., Stedelin, B., Lee, J., Tonsfeldt, K. J., Brown, E. C., Siler, D. A., Paulk, A. C., Yang, J. C., et al. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abj1441 · Cited by 135
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Kozai, T. D. Y., Du, Z. J., Gugel, Z. V., Smith, M. A., Chase, S. M., Bodily, L., Caparosa, E. M., Friedlander, R. M., & Cui, X. T. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.12.010 · Cited by 137
From sensing to control of lower limb exoskeleton: a systematic review
Sun, Y., Tang, Y., Jia, Z., Dong, D., Chen, X., & Bai, L. (2022) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2022.04.003 · Cited by 144
3D-nanostructured boron-doped diamond for microelectrode array neural interfacing
Piret, G., Hébert, C., Mazellier, J.-P., Rousseau, L., Scorsone, E., Cottance, M., Lissorgues, G., Heuschkel, M. O., Picaud, S. A., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.021 · Cited by 142
Flexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G. Z. J., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 135
A Review on Human-Computer Interaction and Intelligent Robots
Ren, F., & Bao, Y. (2019) · International Journal of Information Technology & Decision Making · doi:10.1142/s0219622019300052 · Cited by 140
A Review of Human–Machine Cooperation in the Robotics Domain
Yang, C., Zhu, Y., & Chen, Y. (2021) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2021.3131684 · Cited by 141
Affective Brain–Computer Interfaces (aBCIs): A Tutorial
Wu, D., Lu, B., Hu, B., & Zeng, Z. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3277471 · Cited by 135
Brain-machine interfaces for rehabilitation in stroke: A review
López‐Larraz, E., Sarasola-Sanz, A., Irastorza-Landa, N., Birbaumer, N., & Ramos‐Murguialday, A. (2018) · Neurorehabilitation · doi:10.3233/nre-172394 · Cited by 138
Brain–Computer Interface after Nervous System Injury
Burns, A., Adeli, H., & Buford, J. A. (2014) · The Neuroscientist · doi:10.1177/1073858414549015 · Cited by 132
The state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Edlow, B. L., Sanz, L. R. D., Polizzotto, L., Pouratian, N., Rolston, J. D., Snider, S. B., Thibaut, A., Stevens, R. D., Gosseries, O., members, T. C. C. C. A. I. C., et al. (2021) · Neurocritical Care · doi:10.1007/s12028-021-01227-y · Cited by 132
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Strategies and prospects of effective neural circuits reconstruction after spinal cord injury
Yang, B., Zhang, F., Cheng, F., Ying, L., Wang, C., Shi, K., Wang, J., Xia, K., Gong, Z., Huang, X., et al. (2020) · Cell Death & Disease · doi:10.1038/s41419-020-2620-z · Cited by 128
Lee, J. L., Ozden, I., Song, Y., & Nurmikko, A. V. (2015) · Nature Methods · doi:10.1038/nmeth.3620 · Cited by 128
Neural Substrate Expansion for the Restoration of Brain Function
Chen, H.-C. I., Jgamadze, D., Serruya, M. D., Cullen, D. K., Wolf, J. A., & Smith, D. H. (2016) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2016.00001 · Cited by 127
Staying in the Loop: Relational Agency and Identity in Next-Generation DBS for Psychiatry
Goering, S., Klein, E. P., Dougherty, D. D., & Widge, A. S. (2017) · AJOB Neuroscience · doi:10.1080/21507740.2017.1320320 · Cited by 130
Metadata
- Authors
- Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., & Donoghue, J. P.
- Affiliations
- Brown University (US)
- Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE)
- Harvard University (US)
- Corresponding author
- Hochberg, Leigh R.
- Donoghue, John P.
- ORCID
- Venue
- Nature
- Published
- 2012-05
- Volume
- 485
- Issue
- 7398
- Pages
- 372-375
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC3640850
- OpenAlex
- W2087704839
- Cited by
- 2,719
- References
- 41
- Citations by year
- 2026: 123 · 2025: 170 · 2024: 176 · 2023: 196 · 2022: 166 · 2021: 199 · 2020: 227 · 2019: 206 · 2018: 201 · 2017: 185 · 2016: 203 · 2015: 189 · 2014: 240 · 2013: 184 · 2012: 50
- FWCI
- 107.19
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- elib (German Aerospace Center) (acceptedVersion)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- mediaTUM (Technical University of Munich) (submittedVersion, other-oa)
- Funders
- U.S. Department of Veterans Affairs (A6779-I, B6453-R, B6310N)
- Doris Duke Charitable Foundation
- Craig H. Neilsen Foundation
- Office of Research and Development (A6779I, B6453R)
- European Commission (248587)
- National Institutes of Health (N01-HD-5-3403, n01hd53403-6-0-1, N01HD10018)
- Defense Advanced Research Projects Agency
- Rehabilitation Research and Development Service (B6453R, A6779I)
- Advanced Research Projects Agency
- National Institute on Deafness and Other Communication Disorders (R01DC009899)
- National Institute of Neurological Disorders and Stroke (NS-25074, R37NS025074, R01NS025074, R56 NS025074)
- National Institute of Biomedical Imaging and Bioengineering (R01EB007401)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (RC1HD063931, HHSN275201100018C, N01HD10018, N01 HD053403)
- National Center for Medical Rehabilitation Research (N01HD53403, N01HD10018)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- tetraplegia, brain-computer interface, robot manipulators, neural interfaces, motor cortex, reach and grasp, upper limb paralysis, microelectrode arrays, long-term implantation, assistive devices, neural decoding, stroke, spinal cord injury, amyotrophic lateral sclerosis
- MeSH terms
- Aged, Arm, Calibration, Drinking, Female, Hand, Humans, Male, Man-Machine Systems, Microelectrodes, Middle Aged, Motor Cortex, Movement, Psychomotor Performance, Quadriplegia, Robotics, Time Factors, Hand Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review